Source: Marine Accident Investigation Branch (GOV.UK). Contains public sector information licensed under the Open Government Licence v3.0. — PDF 에서 글을 뽑아 줄을 잇고 호칭 뒤의 인명을 가린 것으로, 원문과 다를 수 있습니다.
용어 밑줄은 영어 사전으로 붙입니다. 조문 연결·대목 나누기·원인 키워드는 국내 재결용 규칙이라 이 자료에는 적용되지 않습니다.
해양사고 조사 보고서로, 사고의 경과, 안전 교훈 및 권고 사항을 담고 있다.Investigation report into marine accident including what happened, safety lessons and recommendations made:
MAIB 조사 보고서 2-2015: ArnistonMAIB investigation report 2-2015: Arniston
MAIB 조사 보고서 2-2015 부록Annexes to MAIB investigation report 2-2015
요약Summary
2013년 4월 1일 컴브리아(Cumbria) 윈더미어 호수(Lake Windermere)에서 모터 크루저 Arniston호에 타고 있던 어머니와 딸이 일산화탄소 중독으로 사망하였다. 이들은 기관실 공간에 설치되어 배기관을 추가하는 방식으로 개조된 휴대용 발전기에서 나온 가스에 중독되었는데, 이 배기관이 이후 파손되어 좁은 취침 공간에 치명적인 일산화탄소가 가득 찼다.On 1 April 2013 a mother and daughter on board the motor cruiser Arniston suffered fatal carbon monoxide poisoning on Lake Windermere, Cumbria. They were overcome by fumes from a portable generator which had been installed in the engine bay and modified by the addition of an exhaust which subsequently failed allowing the small sleeping area to fill with lethal carbon monoxide.
안전 교훈Safety lessons
밀폐된 기관실 공간에 휴대용 공랭식 휘발유 발전기를 설치한 것은 제조사가 제공한 조언에 어긋나는 것이었다the installation of the portable air-cooled petrol generator in the enclosed engine bay was against the advice provided by the manufacturer
발전기에 장착된 임시변통 배기 장치는 목적에 맞지 않았다the improvised exhaust system fitted to the generator was not fit for purpose
보트에서 안전에 중요한 모든 작업은 유능한 선박 기관사가 올바른 자재를 사용하여 수행해야 한다all safety critical work on boats should be undertaken by a competent marine engineer using the correct materials
점선 상자는 있었지만 쓰이지 않았거나 쓰였는지 모르는 것, 점선 화살표는 보고서가 추정한 관계입니다.
③ 원인 사슬
왼쪽에서 오른쪽으로, 무엇이 무엇으로 이어졌는지입니다. 상자(원인)는 보고서 근거 대목에서 가져왔고, 상자 사이 화살표는 보고서가 직접 적지 않은 경우 모델이 판단해 이은 것입니다.
보고서가 밝히지 못한 것
권고·조치
2015/102 기업혁신기술부: RCD 체계로 신조 선박 거주 구역에 CO 감지·경보 수단 갖추는 방안 모색
M2015/103 BSS·MCA·RYA·영국 해양산업연맹·CoGDEM·AINA: CO 위험과 경보기 설치 인식 캠페인
2015/104 BSS: 보트 검사 때 CO 위험 설명·경보기 사용 장려
2015/105 레이크 디스트릭트 국립공원관리청: 관할 내수면에 BSS 도입
MAIB 는 2013년 5월 안전 회보 2/2013 발행. 영국표준협회의 ISO 제안은 받아들여지지 않음. 경보기 '오경보' 오해, BSS 검사·인식 부족도 결론에 포함.
선내에 설치된 경보기가 작동하지 않아 보트 탑승자들은 CO의 존재를 경고받지 못하였다the boat’s occupants were not alerted to the presence of CO because the alarms fitted on board were not working
권고Recommendations
신규 레저 선박에 일산화탄소 경보기가 설치되도록 하는 것을 목적으로, 영국 기업혁신기술부(Department for Business Innovation & Skills)에 권고(2015/102)가 이루어졌다.A recommendation (2015/102) has been made to the Department for Business Innovation & Skills, which is intended to ensure that new recreational craft are fitted with carbon monoxide alarms.
일산화탄소의 위험에 대한 레저 보트 이용자의 인식을 높이고 협력적이고 일치된 캠페인을 통해 일산화탄소 경보기 사용을 촉진하는 것을 목적으로, 영국 내수면 보트안전제도(BSS), 영국 해사연안경비청, 영국 왕립요트협회, 영국 해양산업연맹, 가스 감지 및 환경 모니터링 협의회(Council of Gas Detection and Environmental Monitoring), 내수로 관리당국협회(Association of Inland Navigation Authorities)에도 권고(M2015/103)가 이루어졌다.A recommendation (M2015/103) has also been made to the Boat Safety Scheme, Maritime and Coastguard Agency, Royal Yachting Association, British Marine Federation, Council of Gas Detection and Environmental Monitoring and the Association of Inland Navigation Authorities, aimed at raising the awareness of recreational boaters to the dangers of carbon monoxide and promoting the use of carbon monoxide alarms through a co-ordinated and concerted campaign.
보트 검사 중 일산화탄소 중독의 위험을 파악하고 부각시키는 것을 목적으로, 영국 내수면 보트안전제도에 또 다른 권고(2015/104)가 이루어졌다.A further recommendation (2015/104) has been made to the Boat Safety Scheme, which is aimed at identifying and highlighting the risks of carbon monoxide poisoning during boat examinations.
레이크 디스트릭트 국립공원 관리청(Lake District National Park Authority)에는 관할 수역의 안전을 개선하라는 권고(2015/105)가 이루어졌다.A recommendation (2015/105) has also been made to the Lake District National Park Authority to improve safety on its waters.
한국어는 모델 번역(검수 전)입니다. 표의 값은 흔한 말만 옮기고 나머지는 원문 그대로 둡니다.
본문
PDF 에서 뽑은 글 — 쪽 나눔·단 배치 때문에 줄 순서가 어긋난 곳이 있을 수 있습니다
목차 약어 및 두문자어 용어집 개요 1 1절 사실 정보 2 1.1 Arniston호 및 사고의 개요 2 1.2 경과 4 1.3 병원 이송 및 부검 7 1.4 보트의 이력 및 배치 7 1.5 Arniston호의 소유주 9 1.6 개조 9 1.6.1 발전기 9 1.6.2 배기 계통 11 1.6.3 배선 12 1.6.4 팬 계통 16 1.7 사고 후 검사 및 기술 조사 17 1.7.1 사고 후 검사 17 1.7.2 시험소 검사 21 1.7.3 사고 재현 21 1.7.4 기계 검사 22 1.8 일산화탄소 중독 23 1.9 CO 경보기 24 1.10 윈더미어 26 1.11 보트 안전제도 27 1.11.1 설명 27 1.11.2 보트 검사 27 1.12 EU 레저보트 지침 27 1.13 주거 시설 및 캐러밴의 CO 경보기 규정 28 1.14 현행 CO 인식 제고 활동 28 1.15 과거의 유사 사고 29 1.15.1 MAIB 자료 29 1.15.2 BSS 자료 30 2절 분석 31 2.1 목적 31 2.2 CO 중독 31 2.3 발전기 설치 31 2.4 배기관의 파손 32 2.4.1 개요 32 2.4.2 땜납의 사용 32 2.4.3 지지의 부족 32 2.4.4 압축 이음 33 2.4.5 소음기의 사용 33 2.5 CO의 이동 34 2.5.1 경로와 농도 34 2.5.2 팬의 영향 35 2.6 CO 경보기 35 2.6.1 Arniston호 35 2.6.2 오해 36 2.6.3 설치 요건 37
2.7 '직접 하기(DIY)'의 위험 37 2.8 보트 검사 38 2.9 CO에 대한 인식 38 3절 결론 40 3.1 사고에 직접 기여한 안전 쟁점으로서 해결되었거나 권고로 이어진 것 40 4절 조치 사항 42 4.1 MAIB의 조치 42 4.2 다른 기관이 취한 조치 42 5절 권고 43
그림 그림 1 - 윈더미어 - 북부 구간 그림 2 - Hyundai 발전기 그림 3 - Arniston호의 배치 그림 4 - Arniston호의 거주 구역 그림 5 - CO 경고 그림 6 - 개조 금지 경고 그림 7 - Webasto 소음기 그림 8 - 발전기, 소음기 및 배관의 전체 배치 그림 9 - 배기관에 연결된 직선형 구리 피팅 그림 10 - 파손된 땜납 이음 그림 11 - 소음기에서 선체 관통 피팅까지 그림 12 - 전기 배전반 그림 13 - 전선 이음 그림 14 - 격벽 관통부 그림 15 - 분리된 배기 소음기의 대략적인 위치 표시 그림 16 - 기관실 격벽의 그을린 자국 그림 17 - 기관실 격벽의 땜납 튄 자국 그림 18 - CO 경보기 그림 19 - 연결이 끊어진 CO 경보기 그림 20 - 거주 구역 출입문의 CO 위험 경고 그림 21 - 과거의 부분 파손 그림 22 - 가스의 이동 경로 그림 23 - 천장 내장재 - 가스로 인한 얼룩 그림 24 - 배터리 충전기/팬 스위치 위치 표 표 1 - Hyundai HY 3000SEi 발전기 세트의 사양 표 2 - CO 중독의 증상 표 3 - BSS 자료 - CO 사망자 표 4 - EN 50291-1 경보 조건 부속서 부속서 A - 실험실 보고서 - 레저보트 Arniston호의 Hyundai 발전기 및 관련 배기 계통 검사 부속서 B - 사고 보고서 - 윈더미어. Corgi Technical services Ltd의 재현 결과 보고서(부록 2 생략) 부속서 C - Arniston호에서 사용된 Hyundai HY 3000SEi 발전기 세트의 일산화탄소 배출에 관한 조사 보고서 부속서 D - 보트에서의 일산화탄소 안전 - 보트 안전제도 및 CoGDEM 부속서 E - MAIB 안전 회보(2/2013) 부속서 F - MAIB 안전 회보(1/2014)
약어·용어집GLOSSARY OF ABBREVIATIONS AND ACRONYMS ABYC
- American Boat & Yacht Council AINA - Association of Inland Authorities APPCOG - All Party Parliamentary Group BIS - Department for Business, Innovation and Skills - British Standards Institution - Boat Safety Scheme - Closed-Circuit Television CE - CO - Carbon Monoxide CoGDEM - Council of Gas Detection and Environmental Monitoring COHb - Carboxyhaemoglobin CORGI - Council for Registered Gas Installers - Cardio-Pulmonary Resuscitation EA - Environment Agency EEA - European Economic Area EU - European Union g/kWh - Grams per kilowatt hour - Glass Reinforced Plastic hp - horsepower - International Organisation for Standardisation kg - kilogram kW - kilowatt LDNPA - Lake District National Park Authority
개요SYNOPSIS
On Monday 1 April 2013, the emergency services attended the motor cruiser Arniston on Windermere, Cumbria, where a mother and her daughter had been found unconscious. The two females were taken by air ambulance to Lancaster Royal Infirmary where they were pronounced deceased. A postmortem concluded that the cause of death was poisoning. The subsequent investigation identified that: • The carbon monoxide poisoning had resulted from the inhalation of fumes emitted from a portable generator installed in the boat’s bay. • The external exhaust system fitted to the portable generator had been modified to incorporate a silencer that had become detached from both the generator and the outlet pipe to the vessel’s side. • The portable generator’s engine exhaust fumes filled the engine bay and spread through gaps in an internal into the aft where the mother and daughter were asleep. • The portable generator was not intended by its manufacturer to be installed into an , nor was it intended to be modified in any way. • The improvised exhaust system attached to the generator was constructed from materials and using methods that were not appropriate for this application. • The boat’s occupants were not alerted to the danger because two carbon monoxide sensors fitted to the boat at build were out of date and had been disconnected from the power supply. A recommendation has been made to the Department for Business Innovation & Skills, which is intended to ensure that new recreational craft are fitted with
사실SECTION 1 - FACTUAL INFORMATION
1.1 OF ARNISTON AND ACCIDENT SHIP PARTICULARS Vessel’s name Arniston Flag N/A Type Motor cruiser Registered owner Privately owned 8.70m Build 2002 Weight 3654kg power and type 300hp – 350 MAG Mercruiser petrol drive INFORMATION Date and time 1 April 2013 between 1400 and 1600 Type of marine casualty or incident Very serious marine casualty Location of incident Ferry Nab public - Windermere Place on board Fatalities 2 Persons on board 3 Environment Light wind. Temperature high 5°C, low -1°C
Arniston
1.2 NARRATIVE During the morning of Sunday 31 March 2013, the motor cruiser Arniston was collected from Windermere Aquatics (Figure 1), a Bayliner dealer and service agent in Bowness, Windermere, by its owner. The owner was accompanied by his partner Kelly Webster and Kelly’s 10 year old daughter, Lauren Thornton. He then navigated the boat on Windermere to the Ferry Nab public
분석SECTION 2 - ANALYSIS
2.1 AIM The purpose of the analysis is to determine the contributory causes and circumstances of the accident as a basis for making recommendations to prevent similar accidents occurring in the future. 2.2 CO POISONING The postmortem examinations of Kelly and Lauren identified that they died from CO poisoning. It is evident from the reconstruction of the events leading to their deaths (Paragraph 1.7.3 and Annex B) that the source of the CO was the portable generator fitted in Arniston’s bay. It is also clear that the external exhaust fitted to the portable generator had failed catastrophically (Figure 14), causing the generator’s exhaust to vent directly into the engine bay. The exhaust fumes, which contained high levels of CO, then spread from the engine bay into the boat’s through gaps in the engine bay’s . The only other potential source of CO on board Arniston was the boat’s , which had been operated for only very short periods on 31 March and 1 April 2014. Examination of the external exhaust system (Annex A) showed that it was not gas tight due to the varying quality of its connections (Figure 7). Consequently, even before its failure, the external exhaust system would have been leaking fumes into the engine bay and possibly beyond whenever the generator was . The headaches and physical sickness experienced by Arniston’s owner and Lauren during the morning of 1 April were possibly the early symptoms of CO poisoning (Table 2), but these went unrecognised. 2.3 GENERATOR INSTALLATION Portable “suitcase type” generators, such as the Hyundai HY3000sei, are reasonably quiet, affordable and small in size. They are becoming widely used in a number of applications. Internal combustion engines should not be installed such that their exhausts vent into
결론SECTION 3 - CONCLUSIONS
3.1 SAFETY ISSUES DIRECTLY CONTRIBUTING TO THE ACCIDENT THAT HAVE BEEN ADDRESSED OR RESULTED IN RECOMMENDATIONS 1. The deceased were poisoned by the CO contained in the exhaust fumes from the portable generator installed in the bay. [2.2, 2.3] 2. The generator’s external exhaust system had failed catastrophically, causing the generator to vent directly into the engine bay instead of out of the boat’s side. [2.2, 2.4] 3. The exhaust fumes contained high levels of CO and spread from the engine bay into the boat’s through gaps in a common . [2.2, 2.5] 4. The ‘rich’ air/fuel mixture used by the generator caused the CO concentration in the generator’s exhaust gases to be relatively high. This made the generator even more hazardous if used in an enclosed or unventilated space. [2.3] 5. The portable Hyundai generators were usually supplied with warnings that they should not be used in or be modified. The installation of the portable generator into the engine bay on board Arniston, and the extension and of its exhaust system indicate that these warnings, if supplied in this case, were not heeded by the boat's owner. [2.3] 6. The materials and methods used to construct the external exhaust system were unsuitable and the testing of the generator without an electrical load was unrealistic and misleading. [2.4] 7. The external exhaust system fitted to the portable generator was not fit for purpose. It was not gas-tight and was likely to fail in a number of places because of the use of soft solder, unsuitable compression joints and because the system was unsupported. [2.4] 8. The CO concentration in the aft
조치 사항SECTION 4 - ACTION TAKEN
4.1 ACTIONS The Marine Accident Investigation Branch, in May 2013, issued Safety Bulletin 2/2013 to inform leisure boaters of: • the hazards of using generators in • the dangers of ‘DIY’ • the hazards of . 4.2 ACTIONS TAKEN BY OTHER ORGANISATIONS The British Standards Institution has: Proposed to the International Organisation for Standardisation technical committee 188 working group 12, that a means of detection to alert craft occupants to the outbreak of and the consequential presence of carbon monoxide (CO) is required for craft with more than one habitable space. The proposal was not accepted.
한국어 번역 · 모델 · 검수 전
4절 조치 사항
4.1MAIB의 조치 영국 해양사고조사국(MAIB)은 2013년 5월에 안전 회보 2/2013을 발행하여 레저 보트 이용자에게 다음을 알렸다. • 밀폐된 공간에서 발전기를 사용할 때의 위험 • 'DIY'의 위험 • 일산화탄소의 위험.
4.2다른 기관이 취한 조치 영국표준협회(British Standards Institution)는 다음과 같이 하였다. 거주 가능한 공간이 둘 이상인 선박에는 선박 탑승자에게 화재의 발생과 그에 따른 일산화탄소(CO)의 존재를 알리는 감지 수단이 필요하다고 국제표준화기구(International Organisation for Standardisation) 기술위원회 188 작업반 12에 제안하였다. 이 제안은 받아들여지지 않았다.
권고SECTION 5 - RECOMMENDATIONS
The Department for Business, Innovation and Skills is recommended to: 2015/102 Explore, through the framework, ways of ensuring that new vessels have a means of detecting toxic gases, particularly , in habitable spaces, and alerting occupants to their presence. The , , , , Council of Gas Detection and Environmental Monitoring and the Association of Inland Authorities, are recommended to: M2015/103 Build on current initiatives by engaging with other relevant organisations to conduct a co-ordinated and focused campaign designed to raise the awareness of the leisure boating community of the dangers of CO and the importance of fitting carbon monoxide alarms. Efforts should be focused on, inter alia: • Raising awareness of the likely sources of carbon monoxide. • The dangers of using inappropriate or poorly installed fossil-fuel burning equipment. • The early symptoms of carbon monoxide poisoning. The Boat Safety Scheme is recommended to: 2015/104 Encourage its boat examiners, during the
첨부 문서 2 Annexes to MAIB investigation report 2-2015
[Annexes to investigation report 2-2015]
Annex A Laboratory report - Examination of a Hyundai generator and associated exhaust system from the recreational craft Arniston
Page 4 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 7: Detail of figure 6, showing generator labelling.
Figure 8: Generator as received and viewed from the electrical panel end.
Page 5 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 9: Generator as received and viewed from the exhaust end, and showing the short stub of t he owners supplement exhaust pipework still attached to the exhaust.
Figure 10: Straight copper fitting to integral engine end, showing a ttachment by screws.
Page 6 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 11: As figure 10, viewed from a different camera angle.
Figure 12: As figure 10, viewed from a different camera angle.
Page 7 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 13: As figure 10, viewed from a different camera angle.
Figure 14: Straight copper fitting to engine exhaust joint, showing TTH joint match marking p rior to disassembly.
Page 8 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 15: Integral generator exhaust pipe end, showing three fully penetrating holes through w hich the fixings had fitted.
Figure 16: Screw fixings from the copper pipe to engineexhaust pipe connection (approximate joint cl ock positions shown in brackets) and showing sooting at the tip ends.
Page 9 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 17: End casing of the generator after removal of the copper pipe and showing l ocal condensate corrosion.
Figure 18: Lower, as installed side of the copper fitting, showing condensate rust staining at this si de of the copper fitting.
Page 11 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 21: Copper fitting and 45º copper elbow to short copper pipe piece joints, viewed from the si de of the joints.
Figure 22: Copper fitting and 45º copper elbow to short copper pipe piece joints, viewed from the u nderside of the joints.
Page 16 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
outlet
end
inlet end
Figure 31: As figure 30, viewed from the opposite face of the silencer box.
Figure 32: detail of the screw in the silencer box drain .
Page 17 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 33: Parted joint and migrated copper pipe piece to 45º elbow joint, showing evidence of su itable prior wetting.
Figure 34: As figure 33.
Page 19 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 37: Copper elbow to silencer joint, showing screw and joint sealant.
Figure 38: Copper elbow to silencer joint, showing joint sealant.
Page 20 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 39: Silencer side of the parted joint, showing sooting in the tube bore.
Figure 40: Outlet from the silencer, showing mild sooting of the bore.
Page 25 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 49: As figure 48.
Figure 50: Detail of the untightened jubilee pipe clip at the silencer box end of the flexible hose.
Page 27 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 53: Vessel hull piercing end of the flexible hose, showing a loose untightened j ubilee pipe clip.
Figure 54: Vessel hull piercing end of the flexible hose, showing a loose untightened jubilee clip a nd silver foil insulation over the “worm” part of the clip.
Page 28 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 55: Vessel hull piercing end of the flexible hose, showing silver foil insulation over the “ worm” part of the clip.
Figure 56: As figure 55.
Page 29 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 57: Vessel hull piercing end of the flexible hose, showing only traces of exhaust sooting o f the bore.
Figure 58: Removal location of laboratory specimen M1 from the parted soldered joint.
Page 36 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 71: Micrograph (original image captured at X100), specimen unetched. Detail of figure 70, sh owing the fillet region.
Figure 72: Micrograph (original image captured at X200), specimen unetched. Detail of figure 70, sh owing the intact capillary region.
Page 37 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 73: Micrograph (original image captured at X200), specimen unetched. Specimen M1, sh owing a good solder bond to the copper fitting in the parted region of the joint.
Figure 74: Micrograph (original image captured at X25), specimen unetched. Specimen M2 sh owing an intact solder fillet and well run capillary region.
Page 38 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 75: Micrograph (original image captured at X100), specimen unetched. Detail of figure 74, sh owing the fillet region.
Figure 76: Micrograph (original image captured at X200), specimen unetched. Detail of figure 74, sh owing small volumes of intruded copper and porosity in the capillary region of the joint.
Page 39 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 77: Micrograph (original image captured at X12.5), specimen unetched. Specimen M2 sh owing second side of the joint and melted out fillet.
Figure 78: Micrograph (original image captured at X200), specimen unetched. Detail of figure 77, sh owing well wetted second capillary region of the joint.
Page 40 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 79: Micrograph (original image captured at X500), specimen unetched. Detail of de-wetted r egion in specimen M2 and showing a continuous lead-tin-copper intermetallic layer at the solder to copper interface, consistent with suitable wetting having been achieved.
Figure 80: FTIR Spectrum characterising the elbow to silencer box joint sealant.
Page 41 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 81: FTIR Spectrum for the joint sealant (top of field) and library spectrum for silicone r esin ( of field).
Figure 82: SEM Back scattered electron image, showing EDX analysis fields EDX 1 and EDX 2 in a sample of sealant removed from the copper elbow to silencer box joint – EDX spectra shown in figures 83 and 84.
Page 42 of 42 Client: MAIB, Southampton SO15 2JU & Cumbria Constabulary, Cumbria LA14 2LE Job reference: T31033 ARNISTON
Figure 83: SEM-EDX Spectrum from field EDX 1 shown earlier in figure 82.
Figure 84: SEM-EDX Spectrum from field EDX 2 shown earlier in figure 82.
T31033:
한국어 번역 · 모델 · 검수 전
부속서 A 실험실 보고서 - 레저 선박 Arniston호의 현대(Hyundai) 발전기 및 관련 배기 계통 검사 42쪽 중 4쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 7: 그림 6의 상세, 발전기 표지를 보여 줌.원본 PDF 136쪽그림 8: 입수 당시 상태의 발전기, 전기 패널 쪽 끝에서 본 모습.원본 PDF 91쪽
42쪽 중 5쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 9: 입수 당시 상태의 발전기, 배기 쪽 끝에서 본 모습이며, 소유자가 추가한 배기관의 짧은 토막이 엔진 배기구에 여전히 부착되어 있음을 보여 줌.원본 PDF 138쪽그림 10: 엔진 일체형 배기관 끝에 연결된 직선 구리 이음쇠, 나사로 부착된 모습을 보여 줌.원본 PDF 139쪽
42쪽 중 6쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
NMMA - National Marine Manufacturers Association
ppm - parts per million
-
Recreational Craft Directive
-
Royal Yachting Association
SLDC - South Lakeland District Council UKAS - United Kingdom Accreditation Service UKLPG - United Kingdom
USA - United States of America TIMES: All times used in this report are
+1 unless otherwise stated
한국어 번역 · 모델 · 검수 전
약어 및 두문자어 용어집 ABYC - 미국 보트·요트협의회(American Boat & Yacht Council) AINA - 내수면 항행당국협회(Association of Inland Navigation Authorities) APPCOG - 일산화탄소 초당파 의원 그룹(All Party Parliamentary Carbon Monoxide Group) BIS - 영국 기업혁신기술부(Department for Business, Innovation and Skills) BSI - 영국표준협회(British Standards Institution) BSS - 영국 내수면 보트안전제도(Boat Safety Scheme) CCTV - 폐쇄회로 텔레비전(Closed-Circuit Television) CE - CE 마크(유럽 적합성 표시, Conformité Européenne) CO - 일산화탄소(Carbon Monoxide) CoGDEM - 가스감지 및 환경감시 협의회(Council of Gas Detection and Environmental Monitoring) COHb - 카르복시헤모글로빈(Carboxyhaemoglobin) CORGI - 등록 가스설치업자 협의회(Council for Registered Gas Installers) CPR - 심폐소생술(Cardio-Pulmonary Resuscitation) EA - 환경청(Environment Agency) EEA - 유럽 경제지역(European Economic Area) EU - 유럽연합(European Union) g/kWh - 킬로와트시당 그램(Grams per kilowatt hour) GRP - 유리섬유강화플라스틱(Glass Reinforced Plastic) hp - 마력(horsepower) ISO - 국제표준화기구(International Organisation for Standardisation) kg - 킬로그램(kilogram) kW - 킬로와트(kilowatt) LDNPA - 레이크 디스트릭트 국립공원관리청(Lake District National Park Authority) LOA - 전장(Length overall) MGN - 해사지침 고시(Marine Guidance Note) NMMA - 미국 해양제조업협회(National Marine Manufacturers Association)
ppm - 백만분율(parts per million) RCD - EU 레저보트 지침(Recreational Craft Directive) RYA - 영국 왕립요트협회(Royal Yachting Association) SLDC - 사우스 레이클랜드 지방의회(South Lakeland District Council) UKAS - 영국 인정기구(United Kingdom Accreditation Service) UKLPG - 영국 액화석유가스협회(United Kingdom Liquefied Petroleum Gas) USA - 미합중국(United States of America) 시각: 달리 명시하지 않는 한 이 보고서에 사용된 모든 시각은 UTC+1이다.
carbon monoxide
alarms. A recommendation has also been made to the
,
,
,
, Council of Gas Detection and Environmental Monitoring and the Association of Inland
Authorities, aimed at raising the awareness of recreational boaters to the dangers of
carbon monoxide
and promoting the use of
carbon monoxide
alarms through a co-ordinated and concerted campaign. A further recommendation has been made to the
Boat Safety Scheme
, which is aimed at identifying and highlighting the risks of
carbon monoxide
poisoning during boat examinations. A recommendation has also been made to the Lake District National Park Authority to improve safety on its waters.
한국어 번역 · 모델 · 검수 전
개요 2013년 4월 1일 월요일, 컴브리아(Cumbria)의 윈더미어에 있던 모터 크루저 Arniston호에 응급 구조대가 출동하였는데, 그곳에서 어머니와 딸이 의식을 잃은 채 발견되었다. 두 여성은 구급 헬기로 랭커스터 왕립병원(Lancaster Royal Infirmary)에 이송되었으나 그곳에서 사망 판정을 받았다. 부검 결과 사망 원인은 일산화탄소 중독으로 결론지어졌다. 이후 MAIB 조사에서 다음 사항이 확인되었다. • 일산화탄소 중독은 보트의 기관실에 설치된 휴대용 발전기에서 배출된 가스를 흡입하여 일어났다. • 휴대용 발전기에 장착된 외부 배기 계통은 소음기를 포함하도록 개조되어 있었는데, 그 소음기가 발전기와 선측으로 나가는 배출관 양쪽에서 모두 분리되었다. • 휴대용 발전기 기관의 배기가스가 기관실을 채웠고, 내부 격벽의 틈새를 통해 어머니와 딸이 자고 있던 선미 선실로 퍼졌다. • 휴대용 발전기는 제조사가 밀폐된 공간에 설치하도록 의도한 것이 아니었으며 어떠한 형태로든 개조하도록 의도한 것도 아니었다. • 발전기에 부착된 임시 배기 계통은 이 용도에 적절하지 않은 재료와 방법으로 제작되었다. • 보트 건조 시 설치된 일산화탄소 감지기 2개가 유효 기간이 지났고 전원 공급이 차단되어 있었기 때문에 보트의 탑승자들은 위험을 경고받지 못하였다. 신규 레저보트에 일산화탄소 경보기를 설치하도록 하기 위한 권고가 영국 기업혁신기술부(Department for Business Innovation & Skills)에 제시되었다. 또한 조율되고 일관된 캠페인을 통해 레저 보트 이용자의 일산화탄소 위험에 대한 인식을 높이고 일산화탄소 경보기 사용을 장려하는 것을 목적으로 하는 권고가 영국 내수면 보트안전제도(Boat Safety Scheme), 영국 해사연안경비청, 영국 왕립요트협회, 영국 해양산업연맹, 가스감지 및 환경감시 협의회(Council of Gas Detection and Environmental Monitoring), 내수면 항행당국협회(Association of Inland Navigation Authorities)에 제시되었다. 보트 검사 시 일산화탄소 중독의 위험을 파악하고 부각하는 것을 목적으로 하는 추가 권고가 영국 내수면 보트안전제도에 제시되었다. 또한 레이크 디스트릭트 국립공원관리청(Lake District National Park Authority)이 관할 수역의 안전을 개선하도록 하는 권고도 제시되었다.
jetty
(Figure 1), where his work van was parked. The group’s intention was to spend the remainder of the bank holiday weekend on board Arniston. This was their first trip and overnight stay on the boat in 2013. After Arniston had been secured alongside the public
jetty
, its owner removed a small “suitcase” type generator (Figure 2) from his work van and installed it into Arniston’s
engine
bay (Figure 3). The owner had extended and modified the generator’s exhaust, which he connected to an outlet in the boat’s hull. Figure 1: Windermere - Northern section Windermere Aquatics Ferry Nab Public Jetties Glebe Road
Jetty
Image courtesy of South Lakeland District Council
Figure 2: Hyundai generator Image courtesy of The Test House
Engine
bay Aft
Dinette table Forward
Figure 3: Layout of Arniston Image courtesy of Brunswick Boat Group
During the evening, the group met up with other boat owners and friends at the Ferry Nab
jetty
to celebrate a birthday. The portable generator on board Arniston was
, and the exhaust was seen to be working as intended. The weather was very cold for the time of year so the owner and a friend warmed their hands with warm air flowing from Arniston’s side vents produced by fans in the boat’s
engine
bay. At about 2330, Arniston’s owner returned on board his boat, accompanied by Kelly and Lauren. He had consumed more alcohol than usual but he was not drunk. Once on board, the generator was turned off, and the owner, Kelly and Lauren went to their beds. The following morning, on 1 April, Arniston’s owner, Kelly and Lauren woke up feeling sick and suffering with headaches. Both the owner and Lauren were physically sick; the owner attributed his illness to the over-consumption of alcohol. At about 1130, Arniston’s owner moved his boat 0.75 mile to the Glebe Road public jetties (Figure 1), which had a number of commercial outlets, including fast-food shops, nearby. At about 1300, the owner walked to a fish and chip shop and bought lunch for the group. Kelly and Lauren stayed on the boat. The weather was fine with clear skies and light winds, but the temperature was only about 5°C. Kelly and Lauren were cold when the owner returned from the chip shop. To heat the boat’s
accommodation
the portable generator was started remotely using a fob, in order to power a fan heater (Figure 4). The fan heater had recently been purchased and could be set to either 1kW or 2kW. On this occasion it was on the 1kW setting. Figure 4: Arniston
accommodation
Dinette table Fan heater Image courtesy of Cumbria Constabulary
The group ate their lunch at the dinette table (Figure 4). Shortly after lunch, the owner fell asleep at the table. When he awoke, he felt very unwell; his fingers were numb and he had pains in his chest. The owner was extremely disorientated and was not fully conscious. He struggled onto the
and laid down on the seating area to recover. After an unknown period of time the owner started to feel better and he made his way back down below. The door to the aft
cabin
was ajar, Kelly and Lauren were both inside and appeared to be unconscious. Neither Kelly nor her daughter responded to the owner’s attempts to
them. At 1558, the owner called 999 on his mobile telephone to raise the alarm. He then made his way onto the
jetty
to direct the emergency services to Arniston as soon as they arrived. Between waking and leaving Arniston, the owner also stopped the generator, again using the remote fob. A paramedic in a rapid response vehicle and a police constable were stationed close to the Glebe Road
jetty
and were on scene within minutes. Other emergency service assets and two Windermere lake wardens arrived shortly afterwards. Kelly and Lauren were taken onto the
jetty
, where cardio-pulmonary resuscitation (
) was commenced.
CPR
was continued while they were transferred to Lancaster Royal Infirmary in separate air ambulances. The owner was given oxygen on the
jetty
before he was also taken to hospital. 1.3 HOSPITAL ADMISSION AND POSTMORTEM The levels of carboxyhaemoglobin (COHb) in Kelly and Lauren’s blood on admission to Lancaster Royal Infirmary were 48.5% and 53.6% respectively. The level of COHb in the owner’s blood was 16%. Despite the extensive efforts by paramedics and hospital staff, both Lauren and Kelly were pronounced life extinct by 1755. Postmortem examination confirmed that the cause of Kelly and Lauren’s deaths was
(CO) poisoning. The owner was treated for CO poisoning. 1.4 BOAT HISTORY AND LAYOUT Arniston was a Bayliner 285 motor cruiser that was built in 2002 in the United States of America (USA) by the Brunswick Boat Group, the largest manufacturer of leisure boats in the world. The company builds up to 45 brands of boat including SeaRay, Bayliner and Maxum. The motor cruiser Arniston was 8.7m
length overall
(
LOA
) and was driven by a Mercury Mercruiser 350 MAG, 8
V8 inboard
engine
supplying up to 300hp through a steerable outdrive. The
incorporated a “wet” exhaust system that vented exhaust gases and
through the outdrive. Arniston was divided into four underdeck compartments (Figure 3) comprising an
engine
bay, an aft
cabin
, heads, and a
/dinette area that
led
to a sleeping
berth
in the
. The
engine
bay and aft
cabin
shared a common
, which was not gas tight (see 1.6.4). 1 Carboxyhaemoglobin (COHb) describes the combination of
carbon monoxide
(CO) and haemoglobin that forms in red blood cells when
carbon monoxide
is inhaled or produced in normal metabolism.
When built, Arniston, in common with all Bayliner boats, was certified by the National Marine Manufacturers Association (NMMA). The NMMA website2 provides the following information on industry standards in the USA: “Many — but not all — boats are required to meet a set of minimum manufacturing regulations established by the U.S.
Guard. In the U.S., NMMA Certification goes beyond the minimum
standards to ensure adherence to the American Boat & Yacht Council (ABYC) Standards. Manufacturers of NMMA Certified boats benefit from: • Assurance their boats meet the industry standards for the United States (ABYC Standards) • A detailed inspection and verification process • Improved Consumer Confidence • Increased brand respect • Liability protection and product liability insurance discounts”. [sic] The NMMA certification required that CO alarms and stickers to warn of the dangers of CO were fitted when a boat was built. Arniston was first registered in the USA in March 2003. It was used in the USA for 4 years before being imported into the UK in March 2007. The importation process involved a post-
construction
assessment and a
(CE) marking to comply with the
(
RCD
) . This work was conducted by Human Performance Improvements verification services, a notified body based in Oxford. After arrival into the UK, Arniston was used for 2 years in the Solent before being sold in June 2008. The vessel was then kept in the Poole area but was used infrequently. In May 2012, the current owner purchased Arniston through a broker based in Poole. He then had the boat transported by road to Windermere, where it was launched in June 2012. The owner, Kelly and Lauren used the boat most weekends on the lake during the summer of 2012. In late August 2012, Arniston was stolen from its swinging
on Windermere and was vandalised. Seat covers and canopies were slashed and unsecured items were thrown out of the boat into the lake. The boat was partially repaired at Windermere Aquatics over the winter. 2 ‘Benefits of NMMA certification’ - NMMA website 3 A European Union directive which sets out minimum technical, safety and environmental standards for boats between 2.5m and 24m being traded in Europe. (See paragraph 1.10.3)
1.5 ARNISTON’S OWNER Arniston’s owner was 39 years old. After leaving school he completed a heating and ventilation apprenticeship, during which he gained City and Guilds qualifications in pipe-fitting and welding. He was also on the ‘Gas Safe Register’ , which is the official gas registration for the United Kingdom. In 2007, the owner started a business installing and servicing heating and ventilation systems in commercial premises. The owner had a long association with Windermere. He had enjoyed boating activities on the lake from early childhood on a variety of craft including sailing yachts, small speedboats and larger cruisers. The owner did not
any formal boating qualifications. 1.6 MODIFICATIONS 1.6.1 Generator Arniston’s owner purchased the “suitcase” type Hyundai HY3000sei generator (Figure 2) from an online tool supplier in June 2012. The generator was a 4-stroke, petrol-driven, air-cooled
engine
which was capable of producing 230V power with a maximum output of 2.8kW. It could be started and stopped remotely using a fob and it was fitted with an integral fuel tank. The technical specification of the Hyundai HY3000sei is shown at Table 1. Watts: 2800W Peak Power, 2600W
Running
Power Outlets: 2 x 230V UK 3-pin plug Type: OHV/Forced-Air Cooling, Single
Cylinder
, 4 stroke
: 5.3hp 5500rpm 149CC Hyundai Motor Start: Electric Start or Manual Recoil Fuel Capacity: 4.5 Litres Fuel type: Unleaded Gasoline Dimensions: 550x310x500 millimetres Weight: 35kg Table 1: Specification of Hyundai HY 3000SEi generator set The Hyundai generators were usually supplied with a number of warnings about the dangers of CO if the units were used in unventilated spaces. The warnings (Figure 5) were attached to the units and detailed in the user manuals and other information supplied by the manufacturer. The user manuals also warned that the generator should not be modified (Figure 6). 4 The Gas Safe Register replaced the Council for Registered Gas Installers (CORGI) as the gas registration body in Great Britain and Isle of Man on 1 April 2009 and Northern Ireland and Guernsey on 1 April 2010.
Figure 5: CO warnings
When the generator was bought and first fitted into Arniston’s
engine
bay in 2012, the owner connected a piece of flexible stainless
pipe from the generator’s internal exhaust to a through-hull fitting using a ‘jubilee clip’ at each end. The generator was used on board Arniston during the summer of 2012 without incident, but was removed during the winter. On 31 March 2013, the owner re-installed the generator on the
side of the boat in the enclosed
engine
bay; it was placed on an anti-vibration mat but was not secured to the
engine
bay
. The owner had removed the integral fuel tank from the generator and, in its place, he had fitted a rubber fuel pipe through Arniston’s aft
bulkhead
in order to supply petrol from a portable tank sited in a locker above the swim platform. Due to light-hearted comments from other lake users regarding the noise created by the generator during 2012, the owner modified the system for the 2013 boating season by adding a silencer into the exhaust line. 1.6.2 Exhaust system The owner purchased a Webasto 86450C silencer (Figure 7), which was specifically designed for use with Webasto 5kW diesel heaters and was not approved for any other application. The exhaust line incorporating the silencer was then assembled by the owner and fitted to the generator at his home prior to the trip to Windermere on 31 March. He had tested the combined generator/exhaust system by
running
the
engine
in fresh air. No electrical load was applied. Figure 6: Warning against
The external exhaust system (Figure 8) was constructed as follows: • A 22mm diameter straight copper fitting was secured to the generator’s
engine
with three screws (Figure 9). No sealant was used. • The straight copper fitting attached to the
engine
exhaust was connected to a 45° copper elbow using soft soldered joints and a short section of copper pipe (Figure 9). • A further length of straight copper pipe and another 45° elbow joint were then used to connect to the silencer. The elbow joint was attached to the silencer by a single
and jointing compound (Figure 10). • The silencer was connected to the through-hull fitting by a 24mm flexible
steel
hose, which had ‘jubilee clips’ at each end (Figure 11). On 31 March, when installing the generator, the owner coupled the end of the modified silencer onto the flexible
steel
hose positioning the jubilee clips where the hose overlapped the silencer's outlet. 1.6.3 Wiring Arniston was designed and constructed to use a 120V
shore
power supply, which is used throughout North America. The boat’s distribution panel (Figure 12) housed the breaker switches for the electrical appliances and lights and was located in the aft
cabin
. To enable the Hyundai generator to supply electrical power, the owner had modified the as-built wiring system by cutting the two cables supplying the distribution panel. In effect this disabled the USA
shore
power connections. The Figure 7: Webasto silencer
Image courtesy of The Test House Figure 8:
of the generator, silencer and pipework
Figure 9: Straight copper fitting to
exhaust pipe
Image courtesy of Cumbria Constabulary Figure 10: Failed soldered joint Image courtesy of Cumbria Constabulary
Figure 11: Silencer to through hull fitting Image courtesy of Cumbria Constabulary Jubilee clip Figure 12: Electrical distribution panel Image courtesy of Cumbria Constabulary
owner then connected two wires, each fitted with a standard UK 3-pin plug, to the cables supplying the distribution panel. The wires were connected using plastic terminal blocks that were wrapped in insulating tape (Figure 13). The 3-pin plugs were then connected to the generator to enable 240V power to be supplied to the boat’s appliances via the distribution panel. 1.6.4 Fan system When Arniston’s owner installed the generator in 2012, he also fitted two 240V electrically powered fans that were intended to circulate fresh air around the
engine
bay in the area of the generator. A 23W supply fan was installed, which drew air from vents on the
port
side of the boat through a 4” flexible hose to the area of the generator. An 85W extraction fan was also fitted to draw air from above the generator and expel it via a similar flexible hose and vents, also sited on the
port
side of the hull. The fan system was wired into a breaker switch on the distribution panel in the aft
cabin
. The same switch also controlled the boat’s battery charger. The supply and extraction hoses associated with the fan system, and the 240V electrical supply cables, were routed from the
engine
bay through a large
(Figure 14) in the top corner of the common
bulkhead
between the
engine
bay and the
port
side of the aft
cabin
. Figure 13: Electrical wire joints
1.7 POST-ACCIDENT EXAMINATION AND TECHNICAL INVESTIGATIONS 1.7.1 Post-accident examination On 2 April 2013, the day following the accident,
inspectors and police
examined Arniston, its fittings and associated equipment. Findings included: • The silencer fitted to the generator’s modified exhaust system had completely detached at both ends and was lying on the
engine
bay
deck
(Figure 15). • ‘Scorch’ marks (Figure 16) and evidence of solder ‘splash’ (Figure 17) were found on the heat resistant
bulkhead
lining adjacent to the exhaust outlet pipe on the generator. • The breaker switch on the electrical distribution panel, controlling the
engine
bay fans and the battery charger, was in the ‘off’
. • Arniston was fitted with two SAFE-T-ALERT CO alarms, model number 60-541 (Figure 18). One located on the
deck
head in the aft
cabin
and the other fixed on the
deck
head above the dinette table. Information shown on both alarms indicated that they had been due for
in 2005 and had been date-stamped as being manufactured or fitted on October 8 2002 (Figure 19). • Both CO alarms had been disconnected from the power supply (Figure 19) and were not fitted with internal batteries. • Arniston was also fitted with several stickers (Figure 20) that warned of the hazards of CO. The stickers were required in order for the boat to comply with the NMMA build standard in the USA. Figure 14:
Bulkhead
penetration
Figure 15: Showing
of detached exhaust silencer Image courtesy of Cumbria Constabulary Figure 16: “Scorch” marks
engine
bay on
bulkhead
Image courtesy of Cumbria Constabulary Scorching Exhaust silencer
Figure 17: Solder splash on
engine
bay
bulkhead
Image courtesy of Cumbria Constabulary Scorching Solder Figure 18: CO alarm
Figure 19: Disconnected CO alarm Figure 20: Warning of CO hazard on
accommodation
door
1.7.2 Test House examination The Test House, a United Kingdom Accreditation Service (UKAS) accredited independent commercial testing laboratory, was contracted in June 2013 to perform a laboratory examination and analysis of the mechanical
construction
of the components that made up the exhaust system fitted to the generator. The aims of the tests included: 1. To establish the method of fixing each of the joints. 2. To establish the type and characteristics of the solder used. 3. To establish the effect of the
engine
running
temperature on the joints. Accordingly, each joint was examined and the method and quality of fixing was evaluated. It was established that the gas tight properties of each joint varied considerably. Of note, the flexible hose joints secured by the ‘jubilee clips’ were never able to be gas tight. The Test House report (Annex A) noted: “The bore of the hose at the vessel piercing end exhibited significantly less evidence of sooting, which served to confirm that most, if not all the exhaust, had leaked out of the silencer and flexible hose joint before getting to the outlet end of the hose”. The quality of the soldering on the soldered joints that survived was assessed as adequate for a plumbing application. However, the joints showed signs of having started to melt and open up due to the temperature of the exhaust gases. The solder was analysed and was found to have a high lead content (71.7%). The lead content indicated that the solder would reach a semi-molten pasty state at a temperature of between 183°C and 259°C. Its melting point was 259°C. 1.7.3 Accident reconstruction Between 23 and 25 September 2013, a reconstruction of the failure of the generator exhaust was conducted on board Arniston. The external exhaust used in the reconstruction was fabricated by the Council for Registered Gas Installers (CORGI) Technical Services. CORGI used similar components and materials to those used by Arniston’s owner. The reconstruction aimed to: • Establish the failure mechanism of the external exhaust. • Monitor and record the levels of CO throughout the internal spaces of the boat using calibrated CO sensors placed in the
engine
bay, aft
cabin
and
galley
areas of the boat. For the reconstruction: • The original generator with the identical external exhaust system attached was placed back into Arniston’s
engine
bay.
• The main
accommodation
door was open, the aft
cabin
door and
were ajar, and the awning was down but not secured. • The generator was started remotely using the fob. • The generator was subjected to a 1kW electrical load. • The
engine
bay circulation fans were on. • The generator was observed and recorded via
(
CCTV
). Key findings of the reconstruction were: • The soldered section of the external exhaust adjacent to the silencer was observed to fail after 4 minutes 54 seconds. • The generator exhaust fumes then began to
directly into the enclosed
engine
bay. • CO levels in the aft
cabin
reached 743 parts per million (ppm) after 120 minutes. • After the generator was stopped, the concentration of CO in the aft
cabin
was seen to ‘spike’ and reach 1,239ppm after a further 20 minutes. • Another set of measurements was taken with the doors closed. A CO concentration in the aft
cabin
, of 1,458ppm, was noted after 45 minutes. • It was noted that the CO emissions from the generator appeared to be high. The reconstruction replicated the physical aspects of the accident as closely as possible with the exception of the ambient temperature which was 5°C on the day of the accident and 17°C on the day of the reconstruction. For this reason, readings from the reconstruction must be taken as very close approximations. The CORGI Technical Services report on the reconstruction is at Annex B. 1.7.4 Mechanical examination Following the discovery during the reconstruction of events (1.7.3) that the generator appeared to be emitting high levels of CO, the generator was examined in January 2014 by an expert in combustion, emissions and fuels. A generator of the same model was also examined for comparative purposes. The examination established that both of the generators were set up with a rich air/ fuel mixture that resulted in a CO concentration of over 3% in the exhaust gases, but the emissions still met the type approval requirements for use in Europe. The European standard for the issue of type approval for this class of
engine
requires that the CO emissions should not exceed 610 grams per kilowatt hour (g/kWh). The CO emissions from the Hyundai generator were 248.3 g/kWh. 5 The concentration of
carbon monoxide
in the exhaust gas will depend on the air fuel ratio. If the ratio is greater than 14.7:1 the mixture is said to be lean. The concentration of
carbon monoxide
will be low. If the air fuel ratio is less than 14.7:1 the mixture is said to be rich. There will be only a small amount of oxygen but potentially high concentrations of
carbon monoxide
.
The examination also determined that on both generators the choke to assist cold start was unable to open fully. The main jet of the carburettor fitted on Arniston’s generator was also 0.05mm oversize. Both of these factors would have made the fuel mixture richer and would have resulted in higher concentrations of CO in the exhaust gases. The problem with the choke and the oversize carburettor jet were assessed to have been present at the point of sale as there was no evidence of tool marks. There was also no evidence to suggest that Arniston’s owner had made any modifications that had had an adverse effect on CO emissions from the generator. The report into the condition of the Hyundai generator and its emissions is at Annex C. 1.8
CARBON MONOXIDE
POISONING CO is a poisonous gas with almost the same density as air. It is a by-product of combustion appliances fuelled by oils, solid fuel or gas. Fossil fuelled cookers, heaters, combustion engines and even barbeques all have the potential to cause CO poisoning, particularly if they are incorrectly installed, poorly maintained or used inappropriately. CO poisoning occurs by inhalation. The gas has no smell or taste and for this reason it is sometimes referred to as the ‘silent killer’. Once inside the respiratory system CO binds tightly to haemoglobin to form COHb, and reduces the body’s ability to transport oxygen in the bloodstream. CO binds to haemoglobin approximately 240 times more effectively than oxygen. While a person continues to inhale CO, the levels of COHb in the blood will continue to rise. Only once exposure ends will the body begin to rid itself of CO by exhaling. COHb will then revert back to oxyhaemoglobin, which is the form of haemoglobin that can carry oxygen. It can take approximately 5 hours to remove half of the CO in the blood, although breathing pure oxygen or the use of a hyperbaric chamber can quicken the process. In high concentrations, the effect of CO poisoning is death. However, in lower concentrations, CO poisoning causes illness. The effects of CO poisoning on adults is shown at Table 2 . The most recognisable symptoms are: • headaches • vomiting • tiredness and confusion • stomach pain • shortness of breath and difficulty breathing. 6 Haemoglobin in the blood carries oxygen from the lungs to the rest of the body.
Table 2: Symptoms of
carbon monoxide
poisoning7 It is estimated that 40 people in the UK are killed by CO poisoning each year. At least a further 4,000 people are treated for CO poisoning in hospital. However, the number of people poisoned by CO is likely to be much higher than these figures indicate, as CO poisoning is very difficult to diagnose because symptoms are often similar to common illnesses like flu and food poisoning. 1.9 CO ALARMS CO detectors are designed to trigger an alarm based on an accumulation of CO over time or a sudden rise in CO. Historically, detectors operated by a chemical reaction causing a colour change, an electrochemical reaction that produced current to trigger an alarm, or a semiconductor sensor that changed its electrical resistance in the presence of CO. To meet the requirements of the EN 50291-1 standard for CO alarms, only electrochemical sensors are used today. All compliant CO alarms require a continuous power supply so if the power cuts off, or the batteries fail or are removed, then the alarm becomes ineffective. 7 Essential Gas Safety Manual-Domestic. Sixth Edition: Published March 2012 8 BS EN 50291-1:2010+A1:2012 – Electrical apparatus for the detection of
carbon monoxide
in domestic premises. Part 1: Test methods and performance requirements.
A leaflet produced by the
(
BSS
) and the Council of Gas Detection and Environmental Monitoring (CoGDEM) – ‘
Carbon monoxide
safety on boats’ (Annex D) is aimed at raising the awareness of the dangers and symptoms of CO. It also gives advice on CO alarm placement, including: All cabins with a fuel burning appliance should have a CO alarm fitted. If fuel burning appliances, generators or engines are used whilst people sleep, all sleeping quarters will need their own alarms. If the boat has a single multi-use
cabin
, one alarm is OK. For the best protection, follow the alarm manufacturer’s installation instructions as far as the space and nature of the boat allow. But if the placement directions are difficult to meet on your boat, these are the ‘best practice’ points. Try to place the alarm: • in living quarters between 1m and 3m (on plan view) from the appliance • in living quarters fix alarms high up on a wall, but at least 150mm from the ceiling and where the indicator lights can be seen • in sleeping quarters have the alarm in the “breathing zone”, i.e. near the bed head • before fixing, test that you can hear an alarm from any
position
in the boat (or buy an additional alarm). Although some people may be aware of the early symptoms of CO poisoning, the time when the occupants of a boat are particularly at risk from CO poisoning is while sleeping. For this reason the ‘black spot’ CO indicators that change colour when CO is present are not suitable for boats that are to be used for overnight sleeping. As CO exposure can cause drowsiness, ‘black spot’ CO indicators may also be ineffective if people in non-sleeping compartments are overcome by increasing concentrations of CO. The set points at which alarm indicators and audible alarms must operate simultaneously to comply with the safety standard EN 50291-1 are at Table 2 . Once activated the alarm should continue to operate at
carbon monoxide
concentrations above 50ppm. 9 See paragraph 1.11
CO concentration Without alarm before With alarm before 30 ppm 120
min
- 50 ppm 60
min
90
min
100 ppm 10
min
40
min
300 ppm - 3
min
10 11Table 4: EN 50291-1 alarm conditions CO detectors intended for use in a
are tested to the more rigorous safety standard EN 50291-2 . 1.10 WINDERMERE Windermere is 10.5 miles long and is the largest natural lake in England. There are over 4500 powered boats registered on the lake, which is managed by three organisations: • The Lake District National Park Authority (LDNPA) is responsible for: • Byelaw enforcement relating to
, lights, sailing, steering,
mooring
and alcohol use. • Registration of powered vessels • Lake patrol. • The South Lakeland District Council (SLDC) is responsible for: • Applications for the registration of powered vessels made in person • Administration of public jetties and moorings •
out facilities. • The Environment Agency (EA) is responsible for: • Pollution • Water quality. There are no mandatory safety inspections for boats registered on Windermere and the lake authorities do not participate in the
BSS
. 10 Alarm must not activate before 11 Alarm must activate before 12 BS EN 50291-2:2010 - Electrical apparatus for the detection of
carbon monoxide
in domestic premises. Part 2: Electrical apparatus for continuous operation in fixed installations in recreational vehicles and similar premises including recreational craft – Additional test methods and performance requirements.
1.11
BOAT SAFETY SCHEME
1.11.1 Description The
BSS
is a public safety initiative owned by the Canal & River Trust and the EA. Its purpose is to help minimise the risk of boat fires, explosions, or pollution harming visitors to the inland waterways, the waterways’ workforce and any other users. The remit of the
BSS
is limited to the condition and use of boats and their equipment. The majority of the UK’s inland
navigation
authorities (including Canal & River Trust, EA, Broads Authority, Avon
Navigation
Trust and National Trust) use the
BSS
to ensure that boats meet reasonable standards of safety. Approximately 70,000 boats on the UK’s inland waterways have been certified under the scheme. The authorities that have adopted the
BSS
require
BSS
certificates to have been issued to boats over 4 years old before they can be registered for use on their waters. A
BSS
certificate is valid for 4 years. A number of inland waterways
navigation
authorities do not currently participate in the
BSS
. These include the authorities responsible for
navigation
in the Lake District, Loch Lomond and the Trossachs, and Waterways Ireland. As a result over 7000 leisure boats on the UK’s inland waterways are not certified under the
BSS
. 1.11.2 Boat examination
BSS
boat examinations are conducted only by authorised examiners. Should a boat fail an examination, deficiencies must be rectified before an inland waterways licensing authority will grant a licence to navigate. Deficiencies that are deemed to put people or property in immediate danger or risk are reported to owners. In addition, a warning notice is issued to alert: those responsible for a craft’s condition that a hazardous defect has been identified; anyone stepping on board that they could be at risk. With regard to CO related deficiencies, warnings are supported by the CO Safety on Boats leaflet (Annex D). In cases where there is a risk of
or explosion, examiners will alert the relevant inland
navigation
authority and
mooring
managers to enable appropriate control measures to be implemented. Boat examiners also have the authority to disconnect
cylinders. The condition of outboard and portable combustion engines and portable fuel systems are checked during BBS boat examination. Due to its remit, the
BSS
cannot require boats to be fitted with a CO alarm. 1.12
RECREATIONAL CRAFT DIRECTIVE
In 1998, Directive 94/25/EC (
Recreational Craft Directive
) was introduced by the European Commission to ensure a uniform level of safety in the design and manufacture of recreational craft throughout the European Economic Area (EEA). The Directive established the free movement of recreational craft within the single market, and was implemented in the UK by the Recreational Craft Regulations 1996 S.I.1996/1353 . The Directive was revised in 2003 with the adoption of Directive 13 The Department for Business, Innovation and Skills (BIS) has policy responsibility for the
RCD
2003/44/EC. The
RCD
applies to all craft (with some exemptions) placed on the market or put into service and intended to be used for sporting and recreational purposes that have a hull length of between 2.5 and 24 metres. A boat must comply with the
RCD
by meeting ‘essential safety requirements’ and obtain a CE mark, either at the first point of sale, or when it is first put into service in the EEA, unless it is in transit through, or entering, European Union (EU) waters for touristic reasons. The meeting of the essential requirements is frequently demonstrated by compliance with harmonised standards . None of the
RCD
’s essential requirements include the provision of CO monitors in the build of a boat nor do they require existing CO monitors, where fitted, to be functional if a boat is imported into the EU. Instead, the
RCD
relies on other elements of design to prevent CO and other products of combustion reaching
accommodation
areas, including: 5.1 Engines and
engine
spaces 5.1.1 Inboard
engine
– All inboard mounted engines shall be placed within an enclosure separated from living quarters and installed so as to minimize the risk of fires or spread of fires as well as hazards from toxic fumes, heat, noise or vibrations in the living quarters. 5.5 Gas system – Adequate ventilation must be provided to prevent hazards from leaks and products of combustion. 1.13 CO ALARM REGULATIONS IN DWELLINGS AND CARAVANS The threat of CO poisoning is becoming more widely recognised in the UK, with stricter legislation recently being introduced for new dwellings and new caravans. Building regulations introduced in 2010 in England and Wales for new dwellings require a CO alarm to be fitted in the same room as a new or replacement fixed solid fuel heating appliance. More recently introduced Building Regulations and Building Standards in Northern Ireland and Scotland are more stringent, and require CO alarms to be fitted in rooms containing heating appliances which burn any fossil fuels (i.e. piped gas, bottled gas, oil or solid fuels). CO alarms compliant with BS EN 50291 have been required in new touring caravans and motorhomes since 1 September 2011. 1.14 CURRENT CO AWARENESS INITIATIVES In addition to CoGDEM and the
BSS
, a number of other organisations have been involved in increasing awareness of the dangers of CO in the marine and domestic environments, and promoting the use of CO alarms. The
(
RYA
) has published a safety advisory note covering the dangers of CO. The Gas Safe Register, United Kingdom
Liquefied Petroleum Gas
(UKLPG), and the Camping and Caravanning Club, among others, have promoted the dangers of CO poisoning via poster campaigns. 14 A harmonised standard is a European Standard elaborated on the basis of a request from the European Commission to a recognised European Standards Organisation to develop a European Standard that provides solutions for compliance with a legal provision.
Such initiatives have had the support of the All Party Parliamentary
Carbon Monoxide
Group (APPCOG). APPCOG is a
cross
-party forum for parliamentarians, civil servants and energy industry representatives to research, discuss and address the dangers of CO. The group aims to improve government policy on CO hazards by lobbying on behalf of the public and to work with other stakeholders to raise public awareness. 1.15 PREVIOUS SIMILAR ACCIDENTS 1.15.1
MAIB
data The
MAIB
is aware of a number of accidents and incidents since 1994 in which vessels’ crews have suffered the effects of CO poisoning resulting from the use of petrol driven pumps or generators. These include: Starlight Rays (
MAIB
Report 15/2012) In August 2011, an engineer on board the
Starlight Rays collapsed while using a portable
petrol engine
-driven
pump
inside the vessel’s
. He was evacuated from the vessel and taken to hospital by rescue helicopter; the engineer never regained consciousness. He died from CO poisoning. The
pump
was being used to remove oily water from inside the vessel’s
space. The
pump
’s
petrol engine
ran for about 1 hour in a
with no mechanical ventilation and little natural air circulation. As a result, very high levels of CO accumulated within the
fish hold
. Two other crewmen were also poisoned by CO while trying to rescue the engineer; both survived. This accident demonstrated the ability for high concentrations of CO to quickly incapacitate people in
. It also showed the difficulties posed during rescue efforts in removing an injured crewman from a
compartment
with a noxious atmosphere without risking the lives of the rescuers. Unnamed canal boat In January 2014, a portable generator was used to provide electric power for domestic equipment on board a 40ft long narrow boat being used on inland waterways as a permanent home. The generator was operated under a tonneau cover, which allowed CO to accumulate and enter the
accommodation
area through unsealed doorways. The boat’s owner was found dead on board. Postmortem examination determined that the cause of death was CO poisoning. The boat was not fitted with a CO alarm. Eshcol (
MAIB
report 14/2014) In January 2014, the
MAIB
issued Safety Bulletin 1/2014 (Annex F) after an investigation began into the death of two young fishermen in Whitby harbour. The fishermen had returned from a
trip and had slept on board the boat. Before going to bed, the grill of a butane gas cooker was lit in order to warm the
accommodation
. The following morning the two men were dead in their bunks. The gas grill was still lit and the
accommodation
was full of fumes. Eshcol was not fitted with a CO alarm.
1.15.2
BSS
data The
BSS
records data of CO related incidents concerning boats on inland waterways and also on coastal boats having similar characteristics to inland craft. Table 3 shows data for a 20 year period, up to February 2014, in which 30 boat related CO fatalities were recorded, the largest number of fatalities was caused by portable petrol generators. Source of CO Fatalities Portable petrol generator 9
1.1ARNISTON호 및 사고의 개요 선박 제원 선박명 Arniston 선적국 해당 없음 종류 모터 크루저 등록 소유주 개인 소유 구조 GRP 전장 8.70m 건조 2002년 중량 3654kg 기관 출력 및 종류 300hp - 350 MAG Mercruiser 가솔린 스턴 드라이브 해양사고 정보 일시 2013년 4월 1일 1400에서 1600 사이 해양사고 또는 준해양사고의 종류 초대형 해양사고 사고 위치 윈더미어 페리 냅(Ferry Nab) 공공 잔교 선내 장소 거주 구역 사망자 2 탑승 인원 3 환경 약한 바람. 기온 최고 5°C, 최저 -1°C
Arniston호
1.2경과 2013년 3월 31일 일요일 오전, 모터 크루저 Arniston호는 윈더미어 보네스(Bowness)에 있는 Bayliner 판매·정비 대리점 윈더미어 아쿠아틱스(Windermere Aquatics)(그림 1)에서 소유주가 인수하였다. 소유주는 동거인 Kelly Webster와 Kelly의 10세 딸 Lauren Thornton과 함께였다. 이어 소유주는 보트를 윈더미어에서 항행시켜 자신의 업무용 밴이 주차된 페리 냅 공공 잔교(그림 1)로 갔다. 일행은 공휴일(bank holiday) 연휴 주말의 남은 시간을 Arniston호에서 보낼 생각이었다. 이는 2013년 들어 처음 이 보트를 타고 가서 하룻밤을 묵는 것이었다. Arniston호를 공공 잔교에 접안시킨 뒤 소유주는 업무용 밴에서 작은 "여행가방"형 발전기(그림 2)를 꺼내어 Arniston호의 기관실(그림 3)에 설치하였다. 소유주는 발전기의 배기관을 연장하고 개조하였으며, 이를 선체의 배출구에 연결하였다. 그림 1: 윈더미어 - 북부 구간 윈더미어 아쿠아틱스 페리 냅 공공 잔교 글리브 로드(Glebe Road) 잔교 사우스 레이클랜드 지방의회 제공 이미지
그림 2: Hyundai 발전기 The Test House 제공 이미지 기관실 선미 선실 식탁(다이네트 테이블) 선수 침대 그림 3: Arniston호의 배치 Brunswick Boat Group 제공 이미지원본 PDF 13쪽제3자 저작물 · 내부 열람용Image courtesy of The Test House
저녁에 일행은 생일을 축하하기 위해 페리 냅 잔교에서 다른 보트 소유주들 및 친구들과 만났다. Arniston호의 휴대용 발전기는 가동 중이었고 배기는 의도한 대로 작동하는 것으로 보였다. 그 시기로서는 날씨가 매우 추웠기 때문에 소유주와 한 친구는 Arniston호의 기관실 팬이 만들어 내어 보트의 측면 환기구로 나오는 따뜻한 공기에 손을 녹였다. 2330경 Arniston호의 소유주는 Kelly와 Lauren과 함께 보트에 돌아왔다. 그는 평소보다 많은 술을 마셨지만 취하지는 않았다. 승선한 뒤 발전기를 끄고, 소유주와 Kelly와 Lauren은 잠자리에 들었다. 이튿날인 4월 1일 아침, Arniston호의 소유주와 Kelly와 Lauren은 메스꺼움과 두통을 느끼며 일어났다. 소유주와 Lauren은 둘 다 구토하였고, 소유주는 자신의 증세가 과음 때문이라고 생각하였다. 1130경 Arniston호의 소유주는 보트를 0.75마일 떨어진 글리브 로드 공공 잔교(그림 1)로 옮겼는데, 그 근처에는 패스트푸드점을 비롯한 여러 상업 시설이 있었다. 1300경 소유주는 걸어서 피시앤칩스 가게에 가서 일행의 점심을 샀다. Kelly와 Lauren은 보트에 남았다. 날씨는 맑고 바람이 약하였으나 기온은 5°C 정도에 불과하였다. 소유주가 가게에서 돌아왔을 때 Kelly와 Lauren은 추위를 느끼고 있었다. 보트의 거주 구역을 데우기 위해 팬 히터(그림 4)에 전원을 공급하려고 휴대용 발전기를 리모컨 키(fob)로 원격 시동하였다. 이 팬 히터는 최근에 구입한 것으로 1kW 또는 2kW로 설정할 수 있었다. 이때에는 1kW로 설정되어 있었다. 그림 4: Arniston호의 거주 구역 식탁(다이네트 테이블) 팬 히터 컴브리아 경찰청(Cumbria Constabulary) 제공 이미지 일행은 식탁(그림 4)에서 점심을 먹었다. 점심 직후 소유주는 식탁에서 잠이 들었다. 깨어났을 때 그는 몹시 몸이 좋지 않았다. 손가락이 저리고 가슴에 통증이 있었다. 소유주는 극도로 방향 감각을 잃었고 완전히 의식이 있지는 않았다. 그는 힘겹게 상부 갑판으로 올라가 좌석 구역에 누워 회복을 시도하였다. 알 수 없는 시간이 지난 뒤 소유주는 몸이 나아지기 시작하여 다시 아래로 내려갔다. 선미 선실의 문은 조금 열려 있었고 Kelly와 Lauren은 둘 다 안에 있었는데 의식이 없는 것처럼 보였다. Kelly도 딸도 소유주가 깨우려 해도 반응하지 않았다. 1558에 소유주는 휴대전화로 999에 전화하여 경보를 발령하였다. 이어서 그는 잔교로 나가 응급 구조대가 도착하는 즉시 Arniston호로 안내하였다. 소유주는 깨어난 뒤 Arniston호를 떠나기 전에 역시 리모컨 키를 사용하여 발전기도 정지시켰다. 신속 대응 차량의 응급 구조사와 경찰관 1명이 글리브 로드 잔교 가까이에 배치되어 있었고 몇 분 만에 현장에 도착하였다. 다른 응급 구조 자산과 윈더미어 호수 감시원 2명이 곧이어 도착하였다. Kelly와 Lauren은 잔교 위로 옮겨졌고 그곳에서 심폐소생술(CPR)이 시작되었다. 두 사람이 각각 다른 구급 헬기로 랭커스터 왕립병원에 이송되는 동안에도 CPR은 계속되었다. 소유주는 잔교에서 산소를 공급받은 뒤 마찬가지로 병원으로 이송되었다.
1.3병원 이송 및 부검 랭커스터 왕립병원에 입원하였을 때 Kelly와 Lauren의 혈중 카르복시헤모글로빈(COHb) 1 수치는 각각 48.5%와 53.6%였다. 소유주의 혈중 COHb 수치는 16%였다. 응급 구조사와 병원 직원의 필사적인 노력에도 불구하고 Lauren과 Kelly 두 사람은 모두 1755까지 사망 판정을 받았다. 부검에서 Kelly와 Lauren의 사인이 일산화탄소(CO) 중독임이 확인되었다. 소유주는 CO 중독으로 치료를 받았다.
1.4보트의 이력 및 배치 Arniston호는 2002년 미합중국(USA)에서 세계 최대의 레저 보트 제조업체인 Brunswick Boat Group이 건조한 Bayliner 285 모터 크루저였다. 이 회사는 SeaRay, Bayliner, Maxum을 포함하여 최대 45개 브랜드의 보트를 만든다. 모터 크루저 Arniston호는 전장(LOA)이 8.7m였고, 조향 가능한 아웃드라이브를 통해 최대 300hp를 공급하는 Mercury Mercruiser 350 MAG 8기통 V8 선내 기관으로 구동되었다. 주기관에는 배기가스와 냉각수를 아웃드라이브를 통해 배출하는 "습식" 배기 계통이 있었다. Arniston호는 갑판 아래가 네 개의 구획(그림 3), 즉 기관실, 선미 선실, 화장실, 그리고 선수창(forepeak)의 침대로 이어지는 조리실/식탁 구역으로 나뉘어 있었다. 기관실과 선미 선실은 가스가 새지 않는 구조가 아닌 공통 격벽을 공유하였다(1.6.4 참조). 1 카르복시헤모글로빈(COHb)은 일산화탄소를 흡입하였거나 정상적인 신진대사 중에 생성되었을 때 적혈구 안에서 일산화탄소(CO)와 헤모글로빈이 결합하여 형성되는 물질을 말한다.
Arniston호는 건조될 당시 모든 Bayliner 보트와 마찬가지로 미국 해양제조업협회(NMMA)의 인증을 받았다. NMMA 웹사이트 2 는 미국의 업계 표준에 관하여 다음 정보를 제공한다. "많은 보트가 — 전부는 아니지만 — 미국 해안경비대가 정한 최소 제조 규정을 충족하여야 한다. 미국에서 NMMA 인증은 미국 해안경비대의 최소 기준을 넘어 미국 보트·요트협의회(ABYC) 표준 준수를 보장한다. NMMA 인증 보트의 제조업체는 다음과 같은 혜택을 얻는다. • 자사 보트가 미국의 업계 표준(ABYC 표준)을 충족한다는 보증 • 상세한 검사 및 검증 절차 • 소비자 신뢰 향상 • 브랜드 존중도 증대 • 책임 보호 및 제조물 책임 보험료 할인". [sic] NMMA 인증은 보트를 건조할 때 CO 경보기를 설치하고 CO의 위험을 경고하는 스티커를 부착할 것을 요구하였다. Arniston호는 2003년 3월에 미국에서 처음 등록되었다. 이 보트는 미국에서 4년간 사용된 뒤 2007년 3월 영국으로 수입되었다. 수입 절차에는 건조 후 평가와 EU 레저보트 지침(RCD) 3 에 부합하는 CE 마크(유럽 적합성 표시, Conformité Européenne) 부착이 포함되었다. 이 작업은 옥스퍼드에 본사를 둔 인증 기관(notified body)인 Human Performance Improvements verification services가 수행하였다. 영국에 도착한 뒤 Arniston호는 2년 동안 솔런트(Solent)에서 사용되다가 2008년 6월에 매각되었다. 그 뒤 선박은 풀(Poole) 지역에 보관되었으나 드물게 사용되었다. 2012년 5월 현재의 소유주가 풀에 있는 중개업자를 통해 Arniston호를 구입하였다. 이어서 그는 보트를 육로로 윈더미어에 운송하여 2012년 6월에 진수시켰다. 소유주와 Kelly와 Lauren은 2012년 여름 동안 대부분의 주말에 호수에서 이 보트를 이용하였다. 2012년 8월 말 Arniston호는 윈더미어의 스윙 계류 위치에서 도난당하여 훼손되었다. 좌석 커버와 캐노피가 찢겼고 고정되지 않은 물품은 보트 밖 호수로 던져졌다. 보트는 겨울 동안 윈더미어 아쿠아틱스에서 부분적으로 수리되었다. 2 'NMMA 인증의 이점' - NMMA 웹사이트 3 유럽에서 거래되는 2.5m에서 24m 사이의 보트에 대한 최소 기술, 안전, 환경 기준을 정하고 있는 유럽연합 지침이다. (1.10.3항 참조)
1.5ARNISTON호의 소유주 Arniston호의 소유주는 39세였다. 학교를 마친 뒤 그는 난방·환기 견습 과정을 이수하였으며 그동안 배관 및 용접에 관한 시티 앤드 길즈(City and Guilds) 자격을 취득하였다. 그는 또한 영국의 공식 가스 등록 제도인 '가스 안전 등록부(Gas Safe Register)' 4 에 등록되어 있었다. 2007년에 소유주는 상업 시설의 난방·환기 시스템을 설치하고 정비하는 사업을 시작하였다. 소유주는 윈더미어와 오랜 인연이 있었다. 어릴 때부터 호수에서 세일링 요트, 소형 스피드보트, 대형 크루저 등 다양한 선박으로 보트 활동을 즐겼다. 소유주는 정식 보트 관련 자격은 없었다.
1.6개조 1.6.1 발전기 Arniston호의 소유주는 "여행가방"형 Hyundai HY3000sei 발전기(그림 2)를 2012년 6월에 온라인 공구 판매업체에서 구입하였다. 이 발전기는 4행정 가솔린 구동 공랭식 기관으로, 최대 출력 2.8kW의 230V 전력을 생산할 수 있었다. 리모컨 키로 원격 시동 및 정지가 가능하였으며 일체형 연료 탱크가 있었다. Hyundai HY3000sei의 기술 사양은 표 1과 같다. 와트: 2800W 최대 출력, 2600W 연속 출력 콘센트: 2 x 230V 영국식 3핀 플러그 종류: OHV/강제 공랭, 단기통, 4행정 가솔린 기관: 5.3hp 5500rpm 149CC Hyundai 시동: 전기 시동 또는 수동 리코일 연료 용량: 4.5리터 연료 종류: 무연 가솔린 치수: 550x310x500밀리미터 중량: 35kg 표 1: Hyundai HY 3000SEi 발전기 세트의 사양 Hyundai 발전기는 대개 환기되지 않는 공간에서 장비를 사용할 경우의 CO 위험에 대한 여러 경고와 함께 공급되었다. 경고(그림 5)는 장비에 부착되어 있었고 제조사가 제공한 사용자 설명서와 기타 정보에도 상세히 기재되어 있었다. 사용자 설명서는 또한 발전기를 개조해서는 안 된다고 경고하였다(그림 6). 4 가스 안전 등록부는 2009년 4월 1일에 영국 본토(Great Britain)와 맨 섬(Isle of Man), 2010년 4월 1일에 북아일랜드와 건지(Guernsey)에서 등록 가스설치업자 협의회(CORGI)를 대신하여 가스 등록 기관이 되었다.
그림 5: CO 경고원본 PDF 18쪽
2012년에 발전기를 구입하여 Arniston호의 기관실에 처음 설치할 때 소유주는 유연한 스테인리스강 관 한 토막을 양 끝에 '주빌리 클립(jubilee clip)'을 사용하여 발전기의 내부 배기구에서 선체 관통 피팅까지 연결하였다. 발전기는 2012년 여름 동안 Arniston호에서 사고 없이 사용되었으나 겨울 동안 철거되었다. 2013년 3월 31일 소유주는 발전기를 보트 좌현 쪽의 밀폐된 기관실에 다시 설치하였다. 발전기는 방진 매트 위에 놓였으나 기관실 갑판에 고정되지는 않았다. 소유주는 발전기의 일체형 연료 탱크를 떼어 내고 그 자리에 고무 연료관을 Arniston호의 선미 격벽을 통과하도록 설치하여, 수영 플랫폼 위 수납함에 있는 휴대용 탱크에서 가솔린을 공급하였다. 2012년에 다른 호수 이용자들이 발전기가 내는 소음에 대해 농담조로 언급하였기 때문에, 소유주는 2013년 보트 시즌을 맞아 배기 라인에 소음기를 추가하는 방식으로 계통을 개조하였다. 1.6.2 배기 계통 소유주는 Webasto 86450C 소음기(그림 7)를 구입하였는데, 이는 Webasto 5kW 디젤 히터에 사용하도록 특별히 설계된 것이었으며 다른 용도로는 승인되지 않았다. 소음기를 포함한 배기 라인은 이후 소유주가 조립하여 3월 31일 윈더미어로 떠나기 전에 자택에서 발전기에 장착하였다. 그는 신선한 공기 속에서 기관을 가동하여 발전기/배기 결합 계통을 시험하였다. 전기 부하는 걸지 않았다. 그림 6: 개조 금지 경고 외부 배기 계통(그림 8)은 다음과 같이 구성되었다. • 직경 22mm의 직선형 구리 피팅을 나사 3개로 발전기의 기관 배기관에 고정하였다(그림 9). 실란트는 사용하지 않았다. • 기관 배기구에 부착된 직선형 구리 피팅은 연납(軟-, soft solder) 이음과 짧은 구리관 한 토막을 사용하여 45° 구리 엘보에 연결되었다(그림 9). • 이어서 직선형 구리관 한 토막과 또 하나의 45° 엘보 이음을 사용하여 소음기에 연결하였다. 엘보 이음은 나사 하나와 접합제로 소음기에 부착되었다(그림 10). • 소음기는 24mm 유연한 강철 호스로 선체 관통 피팅에 연결되었고 양 끝에는 '주빌리 클립'이 있었다(그림 11). 3월 31일 발전기를 설치할 때 소유주는 개조된 소음기의 끝을 유연한 강철 호스에 연결하면서 호스가 소음기 배출구와 겹치는 곳에 주빌리 클립을 위치시켰다. 1.6.3 배선 Arniston호는 북미 전역에서 사용되는 120V 육상 전원 공급을 사용하도록 설계 및 건조되었다. 보트의 배전반(그림 12)에는 전기 기기와 조명의 차단기 스위치가 들어 있었고 선미 선실에 위치하였다. Hyundai 발전기가 전력을 공급할 수 있도록 하기 위해, 소유주는 배전반에 전력을 공급하는 케이블 2개를 절단하여 건조 시의 배선 계통을 개조하였다. 사실상 이로 인해 미국식 육상 전원 연결은 사용할 수 없게 되었다. 그림 7: Webasto 소음기 The Test House 제공 이미지 그림 8: 발전기, 소음기 및 배관의 전체 배치
그림 9: 배기관에 연결된 직선형 구리 피팅 컴브리아 경찰청 제공 이미지 그림 10: 파손된 땜납 이음 컴브리아 경찰청 제공 이미지원본 PDF 22쪽제3자 저작물 · 내부 열람용Image courtesy of Cumbria Constabulary그림 11: 소음기에서 선체 관통 피팅까지 컴브리아 경찰청 제공 이미지 주빌리 클립 그림 12: 전기 배전반 컴브리아 경찰청 제공 이미지원본 PDF 23쪽제3자 저작물 · 내부 열람용Image courtesy of Cumbria Constabulary
이후 소유주는 각각 표준 영국식 3핀 플러그가 달린 전선 2개를 배전반에 전력을 공급하는 케이블에 연결하였다. 전선은 절연 테이프로 감싼 플라스틱 단자대를 사용하여 연결되었다(그림 13). 그런 다음 3핀 플러그를 발전기에 연결하여 배전반을 거쳐 보트의 기기에 240V 전력이 공급될 수 있게 하였다. 1.6.4 팬 계통 Arniston호의 소유주는 2012년에 발전기를 설치할 때 발전기 주위의 기관실 구역에 신선한 공기를 순환시키려는 목적으로 240V 전동 팬 2개도 설치하였다. 23W 급기 팬이 설치되었으며, 이는 보트 좌현 쪽의 환기구에서 4" 유연 호스를 통해 발전기 구역으로 공기를 끌어들였다. 85W 배기 팬도 설치되어 발전기 위쪽의 공기를 빨아들이고 선체 좌현 쪽에 있는 같은 종류의 유연 호스와 환기구를 통해 배출하였다. 팬 계통은 선미 선실의 배전반에 있는 차단기 스위치에 결선되어 있었다. 같은 스위치가 보트의 배터리 충전기도 제어하였다. 팬 계통의 급기 및 배기 호스와 240V 전원 케이블은 기관실에서 기관실과 선미 선실 좌현 쪽 사이의 공통 격벽 위쪽 모서리에 있는 큰 개구부(그림 14)를 통해 지나갔다. 그림 13: 전선 이음
1.7사고 후 검사 및 기술 조사 1.7.1 사고 후 검사 사고 다음 날인 2013년 4월 2일에 MAIB 조사관과 경찰관들이 Arniston호, 그 설비와 관련 장비를 검사하였다. 확인된 사항은 다음과 같다. • 발전기의 개조된 배기 계통에 장착된 소음기는 양 끝이 모두 완전히 분리되어 기관실 갑판에 놓여 있었다(그림 15). • 발전기의 배기 배출관에 인접한 내열 격벽 내장재에서 '그을린' 자국(그림 16)과 땜납 '튄' 흔적(그림 17)이 발견되었다. • 기관실 팬과 배터리 충전기를 제어하는 배전반의 차단기 스위치는 '꺼짐' 위치에 있었다. • Arniston호에는 모델 번호 60-541인 SAFE-T-ALERT CO 경보기 2개가 설치되어 있었다(그림 18). 하나는 선미 선실의 천장에, 다른 하나는 식탁 위 천장에 고정되어 있었다. 두 경보기에 표시된 정보는 2005년에 교체 시기가 도래하였음을 나타내며 2002년 10월 8일에 제조 또는 설치된 것으로 날짜가 찍혀 있었다(그림 19). • 두 CO 경보기 모두 전원 공급이 차단되어 있었고(그림 19) 내부 배터리도 장착되어 있지 않았다. • Arniston호에는 CO의 위험을 경고하는 스티커 여러 장도 부착되어 있었다(그림 20). 이 스티커는 보트가 미국의 NMMA 건조 기준에 부합하기 위해 필요한 것이었다. 그림 14: 격벽 관통부
그림 15: 분리된 배기 소음기의 대략적인 위치 표시 컴브리아 경찰청 제공 이미지 그림 16: 기관실 격벽의 "그을린" 자국 컴브리아 경찰청 제공 이미지 그을린 자국 배기 소음기원본 PDF 26쪽제3자 저작물 · 내부 열람용Image courtesy of Cumbria Constabulary그림 17: 기관실 격벽의 땜납 튄 자국 컴브리아 경찰청 제공 이미지 그을린 자국 땜납 그림 18: CO 경보기원본 PDF 27쪽제3자 저작물 · 내부 열람용Image courtesy of Cumbria Constabulary그림 19: 연결이 끊어진 CO 경보기 그림 20: 거주 구역 출입문의 CO 위험 경고원본 PDF 28쪽
1.7.2시험소 검사 영국 인정기구(UKAS)의 인정을 받은 독립 상업 시험소인 The Test House는 2013년 6월에 발전기에 장착된 배기 계통을 구성하는 부품들의 기계적 구조에 대한 실험실 검사 및 분석을 수행하도록 의뢰받았다. 시험의 목적에는 다음이 포함되었다. 1. 각 이음의 고정 방법을 확인하는 것. 2. 사용된 땜납의 종류와 특성을 확인하는 것. 3. 기관 운전 온도가 이음에 미치는 영향을 확인하는 것. 그에 따라 각 이음을 검사하고 고정 방법과 품질을 평가하였다. 각 이음의 기밀 성능은 상당히 다른 것으로 확인되었다. 특기할 점은 '주빌리 클립'으로 고정된 유연 호스 이음은 결코 기밀을 유지할 수 없었다는 것이다. The Test House 보고서(부속서 A)는 다음과 같이 기술하였다. "선체를 관통하는 쪽 호스 끝단의 내경에는 그을음의 흔적이 현저히 적었는데, 이는 배기가스의 전부는 아니더라도 대부분이 호스의 배출 끝에 이르기 전에 소음기와 유연 호스 이음에서 새어 나왔음을 확인해 주는 것이다". 남아 있던 납땜 이음의 땜납 품질은 배관 용도로는 적절한 수준으로 평가되었다. 그러나 이음에는 배기가스의 온도 때문에 녹아 벌어지기 시작한 흔적이 나타났다. 땜납을 분석한 결과 납 함량이 높은 것(71.7%)으로 확인되었다. 납 함량으로 볼 때 이 땜납은 183°C와 259°C 사이의 온도에서 반용융의 죽 상태에 이를 것으로 나타났다. 용융점은 259°C였다. 1.7.3 사고 재현 2013년 9월 23일부터 25일까지 Arniston호 선상에서 발전기 배기관 파손에 대한 재현이 이루어졌다. 재현에 사용된 외부 배기관은 등록 가스설치업자 협의회(CORGI) 기술 서비스(Technical Services)가 제작하였다. CORGI는 Arniston호 소유주가 사용한 것과 유사한 부품과 재료를 사용하였다. 재현의 목적은 다음과 같았다. • 외부 배기관의 파손 메커니즘을 규명하는 것. • 보트의 기관실, 선미 선실, 조리실 구역에 설치한 교정된 CO 센서를 사용하여 보트 내부 공간 전체의 CO 농도를 감시하고 기록하는 것. 재현을 위하여: • 동일한 외부 배기 계통이 부착된 원래의 발전기를 Arniston호의 기관실에 다시 넣었다.
›주 거주 구역 출입문은 열려 있었고, 선미 선실 문과 천창은 조금 열려 있었으며, 차양은 내려져 있었으나 고정되지 않았다. • 발전기는 리모컨 키로 원격 시동하였다. • 발전기에 1kW의 전기 부하를 걸었다. • 기관실 순환 팬은 켜져 있었다. • 발전기는 폐쇄회로 텔레비전(CCTV)을 통해 관찰되고 기록되었다. 재현의 주요 결과는 다음과 같았다. • 소음기에 인접한 외부 배기관의 납땜 부분이 4분 54초 후에 파손되는 것이 관찰되었다. • 이후 발전기 배기가스가 밀폐된 기관실로 직접 배출되기 시작하였다. • 선미 선실의 CO 농도는 120분 후에 743ppm(parts per million)에 이르렀다. • 발전기를 정지한 뒤 선미 선실의 CO 농도는 '급등'하여 20분 후에 1,239ppm에 이르렀다. • 문을 닫은 상태에서 다른 일련의 측정을 하였다. 45분 후에 선미 선실의 CO 농도 1,458ppm이 기록되었다. • 발전기의 CO 배출량이 높은 것으로 보인다는 점이 주목되었다. 재현은 사고의 물리적 측면을 가능한 한 가깝게 재현하였으나 주위 온도는 예외였는데, 사고 당일 5°C였던 반면 재현 당일에는 17°C였다. 이 때문에 재현에서 얻은 측정값은 매우 가까운 근삿값으로 보아야 한다. 재현에 관한 CORGI 기술 서비스 보고서는 부속서 B에 있다. 1.7.4 기계 검사 재현 과정(1.7.3)에서 발전기가 높은 농도의 CO를 배출하는 것으로 보인다는 사실이 발견된 뒤, 연소, 배출가스, 연료 분야의 전문가가 2014년 1월에 발전기를 검사하였다. 비교 목적으로 같은 모델의 발전기도 검사하였다. 검사 결과 두 발전기 모두 공기/연료 혼합비가 농후하게 설정되어 있어 배기가스의 CO 농도가 3%를 넘었으나, 배출량은 여전히 유럽에서 사용하기 위한 형식 승인 요건을 충족하였다. 이 등급의 기관에 대한 형식 승인 발급을 위한 유럽 표준은 CO 배출량이 킬로와트시당 610그램(g/kWh)을 넘지 않을 것을 요구한다. Hyundai 발전기의 CO 배출량은 248.3 g/kWh였다. 5 배기가스 중 일산화탄소의 농도는 공연비(공기 연료 비율)에 따라 달라진다. 이 비율이 14.7:1보다 크면 혼합기는 희박하다고 한다. 일산화탄소 농도는 낮을 것이다. 공연비가 14.7:1보다 작으면 혼합기는 농후하다고 한다. 산소는 소량만 있으나 잠재적으로 일산화탄소 농도는 높을 수 있다.
검사에서는 또한 두 발전기 모두 냉간 시동을 돕는 초크가 완전히 열리지 않는다는 점이 확인되었다. Arniston호의 발전기에 장착된 기화기의 메인 제트도 0.05mm 컸다. 이 두 요인은 모두 연료 혼합기를 더 농후하게 만들었을 것이며 배기가스의 CO 농도를 높였을 것이다. 초크의 문제와 기화기 제트의 치수 초과는 공구 흔적의 증거가 없었으므로 판매 시점에 이미 존재하였던 것으로 평가되었다. 또한 Arniston호의 소유주가 발전기의 CO 배출에 악영향을 미치는 개조를 하였음을 시사하는 증거도 없었다. Hyundai 발전기의 상태와 배출에 관한 보고서는 부속서 C에 있다.
1.8일산화탄소 중독 CO는 공기와 밀도가 거의 같은 유독 가스이다. 이는 기름, 고체 연료 또는 가스를 연료로 하는 연소 기기의 부산물이다. 화석 연료를 쓰는 조리기, 난방기, 내연 기관, 심지어 바비큐까지도 CO 중독을 일으킬 가능성이 있으며, 특히 잘못 설치되었거나 정비가 부실하거나 부적절하게 사용되는 경우에 그러하다. CO 중독은 흡입으로 일어난다. 이 가스는 냄새도 맛도 없기 때문에 '소리 없는 살인자'라고 불리기도 한다. 일단 호흡기에 들어가면 CO는 헤모글로빈 6 과 단단히 결합하여 COHb를 형성하며, 혈류에서 산소를 운반하는 신체 능력을 떨어뜨린다. CO는 산소보다 약 240배 더 효과적으로 헤모글로빈과 결합한다. 사람이 CO를 계속 흡입하는 동안 혈중 COHb 수치는 계속 상승한다. 노출이 끝난 뒤에야 신체는 호흡을 통해 CO를 배출하기 시작한다. 그러면 COHb는 산소를 운반할 수 있는 형태의 헤모글로빈인 산화헤모글로빈으로 되돌아간다. 혈중 CO의 절반을 제거하는 데에는 약 5시간이 걸릴 수 있으나, 순수한 산소를 호흡하거나 고압 챔버를 이용하면 이 과정을 앞당길 수 있다. 고농도에서 CO 중독의 영향은 사망이다. 그러나 저농도에서 CO 중독은 질병을 일으킨다. 성인에 대한 CO 중독의 영향은 표 2에 나와 있다. 가장 알아보기 쉬운 증상은 다음과 같다. • 두통 • 구토 • 피로와 혼란 • 복통 • 숨 가쁨과 호흡 곤란. 6 혈액 속의 헤모글로빈은 폐에서 몸의 나머지 부분으로 산소를 운반한다.
표 2: 일산화탄소 중독의 증상 7 영국에서 해마다 약 40명이 CO 중독으로 사망하는 것으로 추정된다. 이에 더하여 최소 4,000명이 CO 중독으로 병원에서 치료를 받는다. 그러나 CO 중독은 증상이 독감과 식중독 같은 흔한 질병과 비슷한 경우가 많아 진단하기가 매우 어렵기 때문에, CO에 중독된 사람의 수는 이 수치가 나타내는 것보다 훨씬 많을 가능성이 높다.
1.9CO 경보기 CO 감지기는 시간 경과에 따른 CO의 축적이나 CO의 급격한 상승에 따라 경보를 울리도록 설계되어 있다. 과거의 감지기는 색 변화를 일으키는 화학 반응, 경보를 울리기 위한 전류를 발생시키는 전기화학 반응, 또는 CO가 있을 때 전기 저항이 변하는 반도체 센서로 작동하였다. CO 경보기에 대한 EN 50291-1 8 표준의 요건을 충족하기 위해 오늘날에는 전기화학 센서만 사용된다. 요건을 충족하는 모든 CO 경보기는 전원을 지속적으로 공급받아야 하므로, 전원이 끊기거나 배터리가 고장 나거나 제거되면 경보기는 효력을 잃는다. 7 『Essential Gas Safety Manual-Domestic』, 제6판: 2012년 3월 발행 8 BS EN 50291-1:2010+A1:2012 - 가정 시설에서의 일산화탄소 감지용 전기 장치. 제1부: 시험 방법 및 성능 요건.
영국 내수면 보트안전제도(BSS) 9 와 가스감지 및 환경감시 협의회(CoGDEM)가 제작한 리플릿 '보트에서의 일산화탄소 안전'(부속서 D)은 CO의 위험과 증상에 대한 인식을 높이는 것을 목적으로 한다. 이는 또한 다음을 포함하여 CO 경보기 설치 위치에 대한 조언도 제공한다. 연료 연소 기기가 있는 모든 선실에는 CO 경보기를 설치하여야 한다. 사람들이 자는 동안 연료 연소 기기, 발전기 또는 기관을 사용한다면 모든 침실에 자체 경보기가 필요하다. 보트에 다목적 선실이 하나뿐이라면 경보기 하나로 충분하다. 최상의 보호를 위해서는 보트의 공간과 성격이 허용하는 한 경보기 제조사의 설치 지침을 따른다. 그러나 보트에서 설치 위치 지침을 충족하기 어렵다면 다음이 '모범 사례' 요점이다. 경보기를 다음에 설치하도록 한다. • 거주 구역에서는 (평면도상으로) 기기에서 1m에서 3m 사이에 • 거주 구역에서는 경보기를 벽의 높은 곳에, 그러나 천장에서 최소 150mm 떨어지고 표시등이 보이는 곳에 고정 • 침실에서는 경보기를 "호흡 영역", 즉 침대 머리맡 가까이에 • 고정하기 전에 보트 안의 어느 위치에서도 경보음이 들리는지 시험한다(또는 경보기를 추가로 구입한다). 일부 사람들은 CO 중독의 초기 증상을 알고 있을지 모르나, 보트 탑승자가 CO 중독에 특히 취약해지는 때는 잠자는 동안이다. 이러한 이유로 CO가 있을 때 색이 변하는 '블랙 스폿' CO 표시기는 밤에 잠을 자는 용도로 사용되는 보트에는 적합하지 않다. CO에 노출되면 졸음이 올 수 있으므로, 잠자지 않는 구획에 있는 사람들이 점점 높아지는 CO 농도에 압도되는 경우에는 '블랙 스폿' CO 표시기도 효과가 없을 수 있다. 안전 표준 EN 50291-1에 부합하기 위해 경보 표시기와 가청 경보기가 동시에 작동하여야 하는 설정값은 표 2 에 있다. 일단 작동하면 경보기는 50ppm이 넘는 일산화탄소 농도에서는 계속 작동하여야 한다. 9 1.11항 참조 CO 농도 경보 전에는 안 됨 경보 전에는 작동 30 ppm 120분 - 50 ppm 60분 90분 100 ppm 10분 40분 300 ppm - 3분 10 11 표 4: EN 50291-1 경보 조건 해양 환경에서 사용하기 위한 CO 감지기는 보다 엄격한 안전 표준 EN 50291-2 12 에 따라 시험된다.
1.10윈더미어 윈더미어는 길이가 10.5마일이며 잉글랜드에서 가장 큰 자연 호수이다. 이 호수에는 4500척이 넘는 동력 보트가 등록되어 있으며, 호수는 세 기관이 관리한다. • 레이크 디스트릭트 국립공원관리청(LDNPA)은 다음을 담당한다. • 항행, 등화, 세일링, 조타, 계류 및 음주 사용과 관련된 조례의 집행. • 동력 선박의 등록 • 호수 순찰. • 사우스 레이클랜드 지방의회(SLDC)는 다음을 담당한다. • 직접 방문하여 하는 동력 선박 등록 신청 • 공공 잔교와 계류시설의 관리 • 오수 배출 시설. • 환경청(EA)은 다음을 담당한다. • 오염 • 수질. 윈더미어에 등록된 보트에는 의무적인 안전 검사가 없으며 호수 관리 기관들은 BSS에 참여하지 않는다. 10 경보가 작동해서는 안 되는 시간 11 경보가 작동하여야 하는 시간 12 BS EN 50291-2:2010 - 가정 시설에서의 일산화탄소 감지용 전기 장치. 제2부: 레저 차량 및 레저 보트를 포함한 이와 유사한 시설의 고정 설치물에서 지속적으로 작동하는 전기 장치 - 추가 시험 방법 및 성능 요건.
1.11영국 내수면 보트안전제도 1.11.1 설명 BSS는 운하·하천 신탁(Canal & River Trust)과 EA가 소유한 공공 안전 활동이다. 그 목적은 보트 화재, 폭발 또는 오염이 내수면 방문객, 수로 종사자 및 기타 이용자에게 해를 끼칠 위험을 최소화하도록 돕는 것이다. BSS의 권한은 보트와 그 장비의 상태 및 사용에 한정된다. 영국 내수면 항행 당국의 대부분(운하·하천 신탁, EA, 브로즈 당국(Broads Authority), 에이번 항행 신탁(Avon Navigation Trust), 내셔널 트러스트(National Trust) 포함)은 보트가 합리적인 안전 기준을 충족하도록 하기 위해 BSS를 이용한다. 영국 내수면의 약 70,000척의 보트가 이 제도에 따라 인증을 받았다. BSS를 채택한 당국은 건조 후 4년이 넘은 보트가 자기 수역에서 사용하기 위해 등록되려면 먼저 BSS 증서를 발급받아야 한다고 요구한다. BSS 증서의 유효 기간은 4년이다. 일부 내수면 항행 당국은 현재 BSS에 참여하지 않는다. 여기에는 레이크 디스트릭트, 로몬드 호수 및 트로삭스(Loch Lomond and the Trossachs), 워터웨이스 아일랜드(Waterways Ireland)의 항행을 책임지는 당국이 포함된다. 그 결과 영국 내수면의 레저 보트 7000척이 넘게 BSS의 인증을 받지 않았다. 1.11.2 보트 검사 BSS 보트 검사는 공인된 검사관만 수행한다. 보트가 검사에 불합격하면 내수면 면허 당국이 항행 면허를 내주기 전에 결함이 시정되어야 한다. 사람이나 재산을 즉각적인 위험이나 우려에 빠뜨리는 것으로 판단되는 결함은 소유주에게 통보된다. 또한 경고 통지서가 발부되어 다음을 알린다. 선박의 상태를 책임지는 사람들에게는 위험한 결함이 확인되었다는 점, 선내에 발을 들이는 모든 사람에게는 위험에 처할 수 있다는 점. CO 관련 결함에 대해서는 경고에 '보트에서의 CO 안전' 리플릿(부속서 D)이 함께 제공된다. 화재나 폭발의 위험이 있는 경우 검사관은 적절한 통제 조치가 시행될 수 있도록 관련 내수면 항행 당국과 계류시설 관리자에게 알린다. 보트 검사관은 또한 LPG 실린더의 연결을 해제할 권한이 있다. 선외기와 휴대용 내연 기관 및 휴대용 연료 계통의 상태는 BSS 보트 검사 중에 점검된다. BSS는 그 권한의 성격상 보트에 CO 경보기를 설치하도록 요구할 수 없다.
1.12EU 레저보트 지침 1998년에 유럽 경제지역(EEA) 전역에서 레저 보트의 설계 및 제조에 균일한 수준의 안전을 보장하기 위해 유럽위원회가 지침 94/25/EC(레저보트 지침)를 도입하였다. 이 지침은 단일 시장 내 레저 보트의 자유로운 이동을 확립하였고 영국에서는 1996년 레저 보트 규칙(Recreational Craft Regulations 1996 S.I.1996/1353) 13 으로 이행되었다. 이 지침은 2003년에 지침 개정으로 13 기업혁신기술부(BIS)가 RCD에 대한 정책 책임을 진다.
2003/44/EC가 채택되면서 개정되었다. RCD는 선체 길이가 2.5미터에서 24미터 사이이며 스포츠 및 레저 목적으로 사용하기 위해 시장에 출시되거나 취역되는 모든 선박(일부 예외 있음)에 적용된다. 보트는 '필수 안전 요건'을 충족함으로써 RCD를 준수하고 CE 마크를 받아야 하며, 이는 최초 판매 시점이나 EEA에서 처음 취역할 때 이루어지는데, 관광 목적으로 유럽연합(EU) 수역을 통과하거나 진입하는 경우는 제외된다. 필수 요건의 충족은 흔히 조화 표준(harmonised standards) 14 준수로 증명된다. RCD의 필수 요건 어디에도 보트 건조 시 CO 감시기를 제공해야 한다는 내용은 없으며, 보트가 EU로 수입될 때 이미 설치된 CO 감시기가 기능을 유지하여야 한다는 요건도 없다. 그 대신 RCD는 CO 및 기타 연소 생성물이 거주 구역에 도달하는 것을 막기 위해 다음을 포함한 설계의 다른 요소에 의존한다. 5.1 기관 및 기관 구역 5.1.1 선내 기관 - 선내에 장착된 모든 기관은 거주 구역과 분리된 격실 안에 두어야 하고, 거주 구역에서 화재 또는 화재 확산의 위험과 유독 가스, 열, 소음 또는 진동으로 인한 위험을 최소화하도록 설치하여야 한다. 5.5 가스 계통 - 누출 및 연소 생성물로 인한 위험을 방지하기 위해 적절한 환기가 이루어져야 한다.
1.13주거 시설 및 캐러밴의 CO 경보기 규정 영국에서는 CO 중독의 위협이 더 널리 인식되고 있으며, 새 주거 시설과 새 캐러밴에 대해 최근 보다 엄격한 법령이 도입되었다. 2010년에 잉글랜드와 웨일스에서 새 주거 시설에 대해 도입된 건축 규정은 새 고체 연료 고정식 난방 기기나 교체되는 고정식 난방 기기와 같은 방에 CO 경보기를 설치하도록 요구한다. 북아일랜드와 스코틀랜드에서 더 최근에 도입된 건축 규정 및 건축 기준은 더 엄격하여 모든 화석 연료(즉 배관 가스, 병 가스, 기름 또는 고체 연료)를 태우는 난방 기기가 있는 방에 CO 경보기를 설치하도록 요구한다. BS EN 50291을 충족하는 CO 경보기는 2011년 9월 1일부터 새 투어링 캐러밴과 모터홈에 요구되고 있다.
1.14현행 CO 인식 제고 활동 CoGDEM과 BSS 외에도 여러 다른 기관이 해양 및 가정 환경에서 CO의 위험에 대한 인식을 높이고 CO 경보기 사용을 장려하는 데 참여하여 왔다. 영국 왕립요트협회(RYA)는 CO의 위험을 다루는 안전 권고 고시를 발행하였다. 가스 안전 등록부(Gas Safe Register), 영국 액화석유가스협회(UKLPG), 캠핑 앤드 캐러바닝 클럽(Camping and Caravanning Club) 등은 포스터 캠페인을 통해 CO 중독의 위험을 알려 왔다. 14 조화 표준이란 법적 규정을 준수하기 위한 해결책을 제공하는 유럽 표준을 개발해 달라는 유럽위원회의 요청에 따라 인정된 유럽 표준화 기구가 작성한 유럽 표준을 말한다.
이러한 활동은 일산화탄소 초당파 의원 그룹(APPCOG)의 지원을 받아 왔다. APPCOG는 의원, 공무원, 에너지 산업 대표가 CO의 위험을 조사하고 논의하며 다루기 위한 초당파 포럼이다. 이 그룹은 국민을 대신하여 로비 활동을 함으로써 CO 위험에 대한 정부 정책을 개선하고, 다른 이해관계자들과 협력하여 대중의 인식을 높이는 것을 목표로 한다.
1.15과거의 유사 사고 1.15.1 MAIB 자료 MAIB는 1994년 이후 가솔린 구동 펌프나 발전기의 사용으로 인한 CO 중독의 영향을 선박 승조원이 입은 사고 및 준해양사고를 여러 건 알고 있다. 여기에는 다음이 포함된다. Starlight Rays호(MAIB 보고서 15/2012) 2011년 8월 어선 Starlight Rays호의 기관사가 선박의 어창 안에서 휴대용 가솔린 기관 구동 펌프를 사용하다가 쓰러졌다. 그는 선박에서 이송되어 구조 헬기로 병원으로 옮겨졌으나 기관사는 끝내 의식을 회복하지 못하였다. 그는 CO 중독으로 사망하였다. 펌프는 선박의 선수 스러스터 구역 안의 기름 섞인 물을 제거하는 데 사용되고 있었다. 펌프의 가솔린 기관은 기계식 환기가 없고 자연 공기 순환도 거의 없는 구획에서 약 1시간 동안 작동하였다. 그 결과 어창 안에 매우 높은 농도의 CO가 축적되었다. 다른 승조원 2명도 기관사를 구하려다 CO에 중독되었으며 두 사람은 생존하였다. 이 사고는 높은 농도의 CO가 밀폐된 공간에서 사람을 빠르게 무력화할 수 있음을 보여 주었다. 또한 구조자의 생명을 위태롭게 하지 않으면서 유해한 대기가 있는 구획에서 다친 승조원을 꺼내는 구조 활동에 따르는 어려움도 보여 주었다. 이름 없는 운하 보트 2014년 1월 내수면에서 상시 거주지로 사용되던 길이 40피트의 내로보트(narrow boat)의 선내에서 가정용 기기에 전력을 공급하기 위해 휴대용 발전기가 사용되었다. 발전기는 토노 커버(tonneau cover) 아래에서 가동되었고 이로 인해 CO가 축적되어 밀봉되지 않은 출입구를 통해 거주 구역으로 유입되었다. 보트의 소유주는 선내에서 사망한 채 발견되었다. 부검 결과 사인은 CO 중독으로 판정되었다. 보트에는 CO 경보기가 설치되어 있지 않았다. Eshcol호(MAIB 보고서 14/2014) 2014년 1월 MAIB는 휫비(Whitby) 항에서 젊은 어민 2명이 사망한 사고에 대한 조사가 시작된 뒤 안전 회보 1/2014(부속서 F)를 발행하였다. 어민들은 낚시 출어에서 돌아와 보트에서 잠을 잤다. 자러 가기 전에 거주 구역을 데우려고 부탄가스 조리기의 그릴에 불을 붙였다. 이튿날 아침 두 사람은 침대에서 사망해 있었다. 가스 그릴은 여전히 켜져 있었고 거주 구역에는 가스가 가득하였다. Eshcol호에는 CO 경보기가 설치되어 있지 않았다.
1.15.2BSS 자료 BSS는 내수면의 보트 및 내수면 선박과 특성이 비슷한 연안 보트와 관련된 CO 관련 사고의 자료를 기록한다. 표 3은 2014년 2월까지 20년 동안의 자료를 보여 주는데, 이 기간에 보트 관련 CO 사망자 30명이 기록되었고 사망자가 가장 많이 발생한 원인은 휴대용 가솔린 발전기였다. CO의 발생원 사망자 휴대용 가솔린 발전기 9 LPG 기기 8 고체/다중 연료 기기 6 가솔린 선외기 5 기름 연소식(디젤) 난로 1 휴대용 디젤 발전기 1 표 3: BSS 자료 - CO 사망자
. As shown in the accident reconstruction (Annex B), and further confirmed by examination (Annex C), the Hyundai generators, in common with similar generators, operate with a ‘rich’ air/fuel mixture. The ‘rich’ mixture is used to enable them to respond to sudden demands for electrical power. A consequence of the ‘rich’ mixture is that the CO concentration in the generators’ exhaust is relatively high, which makes them even more hazardous if used in enclosed or unventilated spaces. The portable Hyundai generators were usually supplied with warnings that they should not be used in
enclosed spaces
(Figure 5) or be modified (Figure 6). The installation of the portable generator into the
engine
bay on board Arniston, and the extension and
of its exhaust system indicate that these warnings, if supplied in this case, were not heeded by the boat's owner. It is possible that the owner’s decision to fit the generator in this manner was influenced by the need to provide a 240V electrical supply on his boat in a cost-effective way. However, although the owner installed the generator in an
enclosed space
, and subsequently modified its exhaust, it is evident that he foresaw and tried to mitigate some of the potential adverse consequences of his actions. These included: the fitting of fans
in the
engine
bay; the testing of the generator at home with the silencer attached; and, the connection of the exhaust to a through-hull fitting to ensure that the exhaust gases were expelled into the open air. Nonetheless, several safety-critical issues were overlooked. In particular, the replacement of the integral fuel tank with a larger external tank, which required the fitting of a rubber hose routed through the aft
bulkhead
, significantly increased the possibility of
and/or explosion. More importantly, the materials and the methods used to construct the exhaust system were unsuitable, and the testing of the modified generator without an electrical load was unrealistic and misleading. 2.4 FAILURE OF EXHAUST 2.4.1 Overview The manner of the failure of the external exhaust fitted by the owner to the portable generator in Arniston’s
engine
bay shows that it was not fit for purpose. It was not gas-tight and was likely to fail in a number of places for differing reasons. 2.4.2 The use of solder Plumbers’ solder is intended to withstand the temperatures experienced during the passage of water of temperatures up to boiling point. It is not suitable for use on combustion
engine
exhaust systems in which the exhaust gases reach considerably higher temperatures. The Test House examination of the exhaust (Annex A) identified that the soft solder used in the external exhaust’s
reached a semi-molten, pasty state in the temperature range between 183°C and 259°C and that its melting point was 259°C. Therefore, given that the exhaust temperature of the portable generator under a 1KW load was between 250°C and 280°C (Annex C), it is not surprising that the soldered joints failed when the fan heater was switched on. Indeed, solder with a similar melting point failed in less than 5 minutes during the reconstruction. The failure of the external exhaust soon after the fan heater was switched on is also supported by the scorch marks on the heat-resistant cladding inside the
engine
bay (Figure 16). These marks indicate that hot gases had been exhausted in this area for a prolonged period. The Test House examination also identified that the failed soldered joint showed signs of having reached a pasty state on a previous occasion (Figure 21). The partial separation of the joint is likely to have occurred when the generator was
running
during the evening of 31 March. On that occasion, the generator was not under load and therefore its exhaust gas temperatures would have been lower. The semi-molten solder would have cooled and solidified soon after the generator was turned off. 2.4.3 Lack of support Although the Webasto silencer (Figure 7) weighed 0.35kg, the external exhaust system was unsupported throughout its entire length. Therefore, when the solder softened and the vibration increased after the generator was put under load, the
weight of the silencer would have placed a torsional force on the adjacent soldered joint. Consequently, as shown during the reconstruction (Annex B), the weight of the silencer would have contributed to the external exhaust system’s collapse. 2.4.4 Compression joints The 24mm stainless
pipe section of the external exhaust system (Figure 11) was ‘secured’ at both its ends by jubilee clips. Due to the characteristics of the
steel
pipe, it would have been impossible to compress it to effect a gas-tight seal using this method. Consequently, as shown by the evidence highlighted by The Test House examination of the pipe (Annex A) and the reconstruction (Annex B), CO was leaking into the
engine
bay even before the external exhaust system collapsed. 2.4.5 Use of a silencer The silencer was manufactured to be used only in conjunction with the Webasto 5kW diesel heater. No exhaust gas flow rates for the silencer have been found. Therefore, although it is possible that the exhaust gas flow rate from the generator
engine
’s fixed exhaust exceeded that of the Webasto silencer, which would have assisted the external exhaust system failure, this has not been verified. Figure 21: Previous partial failure Image courtesy of The Test House
2.5 THE PASSAGE OF CO 2.5.1 Route and concentration The aft
where Kelly and Lauren went to sleep shared a common
bulkhead
with the
engine
bay (Figure 3). The
bulkhead
was not gas-tight. It had large openings (Figure 14) through which electric cables and pipework were routed. These openings allowed the exhaust gases from the generator to flow from the
engine
bay into the aft
cabin
(Figure 22). The extensive staining found on the deckhead lining of the aft
cabin
(Figure 23) indicates that the atmosphere in the
engine
bay had been venting into the
accommodation
for a prolonged period. The accident reconstruction (Annex B) showed that the levels of CO in the aft
cabin
were considerably higher than those in the
area, which was consistent with the source and the likely passage of the gas. Therefore, as Kelly and Lauren slept in the aft
cabin
, they would have inhaled higher concentrations of CO for a longer period of time than Arniston’s owner, who was asleep at the table in the
galley
. Nonetheless, the condition and the disorientation of the owner when he awoke indicate that he had also been poisoned by the CO. Even though the owner had mainly been in the open air after waking and had been given oxygen by the attending paramedics and on arrival at the hospital, when tested his CO saturation level was still 16%.
Engine
bay Generator Aft
cabin
Galley
Figure 22: Passage of gas Passage of gas Image courtesy of Brunswick Boat Group
2.5.2 Effect of fans The circulation fans in the
engine
bay were reported to be on during the afternoon of 1 April. However, when
inspectors and police examined Arniston on 2 April 2013, the power supply switch to the fans, which was shared with the battery charger, was found to be in the off
(Figure 24). Therefore, there is some doubt whether the fans were operating or not. It is possible that the switch was inadvertently knocked to the ‘off’
position
by the emergency services during the rescue attempt or that the fans were not operating at the time of the accident. Although it cannot be determined for certain whether the fans were operating, it is clear from the accident reconstruction (Paragraph 1.7.3 and Annex B) that, with the fans operating and the doors open, a CO concentration of 743ppm accumulated in the aft
cabin
in 2 hours. Table 2 shows that such a concentration has the potential to be fatal within 2 to 3 hours. Other configurations of the doors and the fans would have
led
to fatal concentrations of CO being reached much sooner. The sudden rise in the CO concentration to 1,239ppm in the aft
cabin
, immediately after the generator was stopped during the reconstruction, was almost certainly due to the circulation fans stopping at the same time as the generator. 2.6 CO ALARMS 2.6.1 Arniston The CO alarms fitted on board Arniston were over 7 years past their replacement date, and after the accident it was established that they had been disconnected from the power supply (Figure 19). It has not been possible to determine when the detectors were disconnected. However, anecdotal evidence indicates that CO alarms are typically disconnected because they activate as a result of their deteriorating condition (time expired). It is also possible that the alarms were Figure 23: Deckhead lining - gas staining
disconnected because they were activating due to the periodic presence of CO in the atmosphere on board and had become an ‘annoyance’. Either way, the absence of at least one functioning CO alarm in Arniston’s
accommodation
meant that a vital barrier to protect the boat’s occupants from the dangers of CO was not in place. Had a stand-alone CO alarm been fitted to Arniston, it would have activated within 3 minutes of the hazardous concentration of CO being detected. 2.6.2 Misconceptions It is a common misconception in leisure boating circles that CO alarms are prone to ‘false alarms’ and that they are therefore not suitable for use in the
. The activating of a CO alarm is nearly always due to the presence of CO in the concentration exceeding those shown in Table 4 . There are many sources Figure 24: Battery charger/fans switch
position
of CO in and around boats, and an alarm could be set off for several reasons, including exhaust fumes from a boat’s
engine
being blown into the
accommodation
. In such circumstances, these are alarms, not false alarms; the detector is behaving as intended. As CO is invisible, and has no smell or taste, any CO alarm activation should always be treated seriously and appropriate action taken. CO alarms that are intended for use in recreational craft are now tested to a rigorous standard. Therefore, boaters should be reassured that such alarms are designed to operate effectively in the harsher environments experienced on board. 2.6.3 Fitting requirements In the UK, there is no requirement for recreational craft, including those intended for overnight sleeping, to be fitted with a CO alarm. Neither the
and its associated harmonised standards, nor the
certification process, require CO alarms to be fitted to new or existing boats. CO kills as effectively on a boat as it does in a home or a caravan. Therefore, it should be common sense that measures are introduced to protect recreational mariners on new boats from the danger of CO to the same extent as the protection already afforded occupants of new caravans and new dwellings. Although the
RCD
relies on other elements of design to prevent exhaust gases reaching
accommodation
areas, the fitting of a CO alarm is a simple and cost-effective measure that can save lives in the event of material failure or the malfunction of other equipment or fittings. Furthermore, a CO alarm has the potential to play a significant role in
fire
detection on board all boats (though the presence of a CO alarm should never be used as a reason not to fit a suitable smoke detector). Mandating the fitting of CO alarms will help to protect an increasing number of boat users over time, as new boats enter service. However, in view of the near 80000 recreational boats currently kept on the UK’s inland waterways alone, together with the incidence of CO-related fatalities on UK waterways (Paragraph 1.15.2), it is important that the owners of existing recreational craft also fit CO alarms. Moreover, the alarms fitted must meet the standard EN 50291-2 in order to withstand the
marine environment
. Many stand-alone CO alarms currently produced (and compliant with EN 50291-2) have an effective lifetime of between 7 and 10 years, some have sealed-for-life batteries and lifetime warranties. If a boat has CO alarms that rely on its integral power supply, it is good practice to also fit ‘stand-alone’ alarms as a backup. This will ensure that the occupants are protected should the boat’s power supply fail. All alarms should be regularly tested using their push-button test facility to ensure they will operate when required. 2.7 HAZARDS OF ‘DIY’ Arniston’s owner was a qualified plumber. Therefore, not surprisingly, the soldered joints on the generator exhaust system were of an adequate standard for use in a hot water system. Also, the owner had tested the exhaust system on the generator after its assembly. However, the test was not conducted with the generator under load. It did not produce the temperatures needed to identify that the use of soft
solder and plumbers’ fittings were totally inappropriate in the generator exhaust system. Consequently, the exhaust fittings did not fail during the test, which gave the owner misplaced confidence in his work. During the
of the
MAIB
investigation into this accident, it was found that a number of other boat owners on Windermere had also installed portable generators in
enclosed spaces
. Many had installed the generators themselves. Do-it-yourself (DIY) work is very popular in the marine leisure sector and is seen as an enjoyable part of boat ownership. It also helps to reduce the costs of
running
and maintaining a boat. Nonetheless, there are numerous systems on board boats that, regardless of a boat owner’s engineering and mechanical skills, should only be installed, maintained or modified by a qualified marine engineer. In such situations, marine engineers should also follow equipment manufacturers’ instructions and use the correct tools and materials. The financial cost of using marine engineers to complete safety-critical work is inevitably more expensive than the cost of ‘DIY’. However, where safety critical systems are concerned such expenditure should be factored in to the cost of boat ownership. 2.8 BOAT EXAMINATIONS The boat examinations conducted by the
BSS
are useful in identifying and highlighting potentially dangerous CO-emitting installations to enable remedial action to be taken. In this case, had the exhaust not failed so soon after installation and in the meantime Arniston had been examined under the
BSS
certification process, it is possible that: • The inappropriate use of the portable generator in the confines of the
engine
bay would have been identified. • Appropriate warnings would have been issued. • Arniston’s owner would have been advised to replace the disconnected CO alarms. • Arniston’s owner would have been given a copy of the CO Safety on Boats leaflet (Annex D). Given the circumstances of the deaths on board Arniston, together with the incidence of portable generators installed on other craft on Windermere, it is evident that the adoption of the
BSS
or similar by the lake’s controlling authority has the potential to prevent similar accidents occurring in the future. 2.9 AWARENESS OF CO CO is a killer. The gas is produced from a variety of sources, some of which are not as apparent as others. Appliances such as gas fires, cookers, water heaters and open fires that use gas, oil, coal and wood are all sources of CO. Disposable barbeques have also been known to be lethal when used in a
confined space
.
Although there are many sources of CO on board boats, many boaters are unaware of the risks of CO poisoning. Such risks are probably increased on boats equipped and used for overnight sleeping. It is likely that numerous cases of CO poisoning are not identified because of this lack of awareness and the symptoms are attributed to other, unspecified illnesses or causes because, in the absence of a CO alarm, the presence of CO is not established. The work of the
BSS
, CoGDEM and other organisations to try and raise the awareness of recreational boaters to the dangers of CO, including its sources, the symptoms of CO poisoning and the fitting of alarms, is extremely positive. Nonetheless, given the number of recreational craft and recreational boaters in the UK (the population at potential risk), together with the previous accidents and accident statistics detailed in Paragraph 1.15, it is clear that more needs to be done.
한국어 번역 · 모델 · 검수 전
2절 분석
2.1목적 분석의 목적은 향후 유사한 사고의 발생을 방지하기 위한 권고의 근거로서 사고의 기여 원인과 경위를 규명하는 것이다.
2.2CO 중독 Kelly와 Lauren에 대한 부검에서 두 사람이 CO 중독으로 사망하였음이 확인되었다. 사망에 이르게 한 사건의 재현(1.7.3항 및 부속서 B)으로부터 CO의 발생원이 Arniston호의 기관실에 설치된 휴대용 발전기였음이 분명하다. 또한 휴대용 발전기에 장착된 외부 배기관이 치명적으로 파손되어(그림 14) 발전기의 배기가 기관실로 직접 배출되었음도 분명하다. 높은 농도의 CO를 함유한 배기가스는 이후 기관실 격벽의 틈새를 통해 기관실에서 보트의 거주 구역으로 퍼졌다. Arniston호에서 CO의 유일한 다른 잠재적 발생원은 주기관이었으나, 이는 2014년 3월 31일과 4월 1일에 매우 짧은 시간 동안만 가동되었다. 외부 배기 계통에 대한 검사(부속서 A) 결과 연결부의 품질이 제각각이어서 이 계통이 기밀하지 않았음이 확인되었다(그림 7). 따라서 파손되기 전에도 발전기가 가동될 때마다 외부 배기 계통은 기관실로, 어쩌면 그 너머로도 배기가스를 누출시키고 있었을 것이다. 4월 1일 오전에 Arniston호의 소유주와 Lauren이 겪은 두통과 구토는 CO 중독의 초기 증상(표 2)이었을 가능성이 있으나 이는 알아채지 못하였다.
2.3발전기 설치 Hyundai HY3000sei와 같은 휴대용 "여행가방형" 발전기는 비교적 조용하고 가격이 적당하며 크기가 작다. 이러한 발전기는 여러 용도에 널리 쓰이게 되고 있다. 내연 기관은 배기가 밀폐된 공간으로 배출되도록 설치해서는 안 된다. 사고 재현(부속서 B)에서 나타나고 검사(부속서 C)로 한층 확인되었듯이, Hyundai 발전기는 유사한 발전기와 마찬가지로 '농후한' 공기/연료 혼합기로 작동한다. '농후한' 혼합기는 갑작스러운 전력 수요에 대응할 수 있도록 사용된다. '농후한' 혼합기의 결과로 발전기 배기가스 중의 CO 농도가 비교적 높아지며, 이 때문에 밀폐되거나 환기되지 않는 공간에서 사용될 경우 위험은 더욱 커진다. 휴대용 Hyundai 발전기는 대개 밀폐된 공간에서 사용해서는 안 된다는 경고(그림 5)와 개조해서는 안 된다는 경고(그림 6)와 함께 공급되었다. Arniston호 선내 기관실에 휴대용 발전기를 설치하고 그 배기 계통을 연장하고 개조한 것은, 이 경우에 경고가 제공되었다면 그 경고를 보트 소유주가 따르지 않았음을 나타낸다. 소유주가 발전기를 이런 식으로 설치하기로 한 결정은 보트에서 240V 전력 공급을 비용 효율적으로 확보해야 한다는 필요에 영향을 받았을 가능성이 있다. 그러나 소유주가 발전기를 밀폐된 공간에 설치하고 이후 그 배기관을 개조하기는 하였지만, 그가 자신의 행동이 낳을 수 있는 잠재적인 부정적 결과 일부를 예견하고 이를 완화하려고 노력하였음은 분명하다. 여기에는 기관실에 팬을 설치한 것,소음기를 부착한 상태로 자택에서 발전기를 시험한 것, 배기가스가 외기로 배출되도록 배기관을 선체 관통 피팅에 연결한 것이 포함된다. 그럼에도 안전상 결정적인 여러 문제가 간과되었다. 특히, 일체형 연료 탱크를 더 큰 외부 탱크로 교체하여 선미 격벽을 통과하는 고무 호스를 설치해야 했던 것은 화재 및/또는 폭발 가능성을 크게 높였다. 더 중요한 것은 배기 계통을 제작하는 데 사용된 재료와 방법이 부적절하였고, 개조한 발전기를 전기 부하 없이 시험한 것은 비현실적이고 오해의 소지가 있었다는 점이다.
2.4배기관의 파손 2.4.1 개요 소유주가 Arniston호 기관실의 휴대용 발전기에 장착한 외부 배기관의 파손 양상은 그것이 목적에 부합하지 않았음을 보여 준다. 그것은 기밀하지 않았고 서로 다른 이유로 여러 곳에서 파손될 가능성이 있었다. 2.4.2 땜납의 사용 배관공용 땜납은 끓는점까지의 온도에 이르는 물이 흐를 때 겪는 온도를 견디도록 만들어진 것이다. 배기가스가 훨씬 높은 온도에 이르는 내연 기관 배기 계통에 사용하기에는 적합하지 않다. The Test House의 배기관 검사(부속서 A)에서 외부 배기관 제작에 사용된 연납이 183°C와 259°C 사이의 온도 범위에서 반용융의 죽 상태에 이르며 그 용융점은 259°C임이 확인되었다. 따라서 1KW 부하에서 휴대용 발전기의 배기 온도가 250°C에서 280°C 사이였음(부속서 C)을 감안하면 팬 히터를 켰을 때 납땜 이음이 파손된 것은 놀라운 일이 아니다. 실제로 재현 과정에서 용융점이 비슷한 땜납은 5분도 안 되어 파손되었다. 팬 히터를 켠 직후 외부 배기관이 파손되었다는 점은 기관실 내부 내열 피복의 그을린 자국(그림 16)으로도 뒷받침된다. 이 자국은 뜨거운 가스가 이 구역으로 장시간 배출되었음을 나타낸다. The Test House의 검사에서는 파손된 납땜 이음이 이전에도 죽 상태에 이른 흔적을 보였다는 점도 확인되었다(그림 21). 이음이 부분적으로 분리된 것은 3월 31일 저녁에 발전기가 가동되고 있을 때 일어났을 가능성이 높다. 그때 발전기에는 부하가 걸려 있지 않았으므로 배기가스 온도가 더 낮았을 것이다. 반용융 상태의 땜납은 발전기를 끈 직후 식어서 굳었을 것이다. 2.4.3 지지의 부족 Webasto 소음기(그림 7)의 무게는 0.35kg이었음에도 외부 배기 계통은 전체 길이에 걸쳐 지지되어 있지 않았다. 따라서 땜납이 물러지고 발전기에 부하가 걸린 뒤 진동이 증가하였을 때,소음기의 무게는 인접한 납땜 이음에 비틀림 힘을 가하였을 것이다. 따라서 재현(부속서 B)에서 나타났듯이 소음기의 무게는 외부 배기 계통의 붕괴에 기여하였을 것이다. 2.4.4 압축 이음 외부 배기 계통의 24mm 스테인리스강 관 구간(그림 11)은 양 끝이 주빌리 클립으로 '고정'되어 있었다. 강관의 특성상 이 방법으로는 기밀 밀봉이 이루어지도록 압축하는 것이 불가능하였을 것이다. 따라서 The Test House의 관 검사(부속서 A)와 재현(부속서 B)에서 강조된 증거가 보여 주듯이, 외부 배기 계통이 붕괴하기 전에도 CO가 기관실로 새고 있었다. 2.4.5 소음기의 사용 이 소음기는 Webasto 5kW 디젤 히터와 함께만 사용하도록 제조되었다. 이 소음기에 대한 배기가스 유량 자료는 발견되지 않았다. 따라서 발전기 기관의 고정 배기구에서 나오는 배기가스 유량이 Webasto 소음기의 유량을 초과하여 외부 배기 계통의 파손을 부추겼을 가능성은 있으나 이는 확인되지 않았다. 그림 21: 과거의 부분 파손 The Test House 제공 이미지
2.5CO의 이동 2.5.1 경로와 농도 Kelly와 Lauren이 잠자리에 든 선미 선실은 기관실과 공통 격벽을 공유하였다(그림 3). 그 격벽은 기밀하지 않았다. 전기 케이블과 배관이 지나가는 큰 개구부(그림 14)가 있었다. 이 개구부를 통해 발전기의 배기가스가 기관실에서 선미 선실로 흘러들 수 있었다(그림 22). 선미 선실 천장 내장재에서 발견된 광범위한 얼룩(그림 23)은 기관실의 대기가 장시간 거주 구역으로 배출되고 있었음을 나타낸다. 사고 재현(부속서 B)에서 선미 선실의 CO 농도가 조리실 구역보다 상당히 높게 나타났는데, 이는 발생원과 가스의 예상 이동 경로에 부합하였다. 따라서 Kelly와 Lauren은 선미 선실에서 잠을 잤으므로 조리실 식탁에서 잠들어 있던 Arniston호 소유주보다 더 높은 농도의 CO를 더 오랜 시간 흡입하였을 것이다. 그럼에도 소유주가 깨어났을 때의 상태와 방향 감각 상실은 그 역시 CO에 중독되었음을 나타낸다. 소유주는 깨어난 뒤 대부분 야외에 있었고 현장의 응급 구조사와 병원 도착 시에 산소를 공급받았음에도 검사에서 그의 CO 포화 수치는 여전히 16%였다. 기관실 발전기 선미 선실 조리실 선수창 침대 그림 22: 가스의 이동 경로 가스의 이동 경로 Brunswick Boat Group 제공 이미지2.5.2 팬의 영향 기관실의 순환 팬은 4월 1일 오후에 켜져 있었던 것으로 보고되었다. 그러나 MAIB 조사관과 경찰이 2013년 4월 2일에 Arniston호를 검사하였을 때, 배터리 충전기와 공유하는 팬의 전원 스위치는 꺼짐 위치에 있는 것으로 확인되었다(그림 24). 따라서 팬이 작동하고 있었는지 여부는 다소 의문이다. 구조 시도 중에 응급 구조대가 스위치를 실수로 '꺼짐' 위치로 건드렸을 수도 있고, 사고 당시에 팬이 작동하지 않았을 수도 있다. 팬이 작동하고 있었는지는 확실히 판정할 수 없으나, 사고 재현(1.7.3항 및 부속서 B)에서 팬이 작동하고 문이 열려 있는 상태에서도 선미 선실에 2시간 만에 743ppm의 CO 농도가 축적되었음은 분명하다. 표 2는 이러한 농도가 2시간에서 3시간 안에 치명적일 가능성이 있음을 보여 준다. 문과 팬의 다른 구성에서는 치명적인 CO 농도에 훨씬 더 일찍 도달하였을 것이다. 재현 과정에서 발전기를 정지한 직후 선미 선실의 CO 농도가 1,239ppm으로 갑자기 상승한 것은 거의 틀림없이 순환 팬이 발전기와 동시에 멈추었기 때문이다.
2.6CO 경보기 2.6.1 Arniston호 Arniston호에 설치된 CO 경보기는 교체 시기를 7년 넘게 지난 것이었고, 사고 후 전원 공급이 차단되어 있었음이 확인되었다(그림 19). 감지기의 연결이 언제 끊어졌는지는 판정할 수 없었다. 그러나 정황 증거는 CO 경보기가 노후(기한 만료)로 인해 작동하기 때문에 보통 연결이 끊기는 것임을 시사한다. 경보기가 선내 대기에 주기적으로 CO가 존재하여 작동하다가 '성가신 것'이 되어 그림 23: 천장 내장재 - 가스로 인한 얼룩연결이 끊어졌을 가능성도 있다. 어느 쪽이든 Arniston호의 거주 구역에 작동하는 CO 경보기가 적어도 하나 없었다는 것은 보트 탑승자를 CO의 위험으로부터 보호하는 필수적인 방벽이 마련되어 있지 않았음을 의미하였다. Arniston호에 독립형 CO 경보기가 설치되어 있었다면 위험한 농도의 CO가 감지된 때부터 3분 안에 작동하였을 것이다. 2.6.2 오해 레저 보트 이용자들 사이에서 CO 경보기가 '오경보'를 일으키기 쉬워 해양 환경에서 사용하기에 적합하지 않다는 것은 흔한 오해이다. CO 경보기의 작동은 거의 언제나 표 4에 제시된 농도를 넘는 농도의 CO가 존재하기 때문이다. 보트 안팎에는 CO의 발생원이 많이 있다 그림 24: 배터리 충전기/팬 스위치 위치 . 경보기는 보트 기관의 배기가스가 거주 구역으로 날려 들어오는 것을 포함하여 여러 이유로 작동할 수 있다. 이런 상황에서 이것은 오경보가 아니라 경보이며, 감지기는 의도한 대로 작동하는 것이다. CO는 눈에 보이지 않고 냄새도 맛도 없으므로 CO 경보기가 작동하면 언제나 심각하게 받아들이고 적절한 조치를 취하여야 한다. 레저 보트에 사용하기 위한 CO 경보기는 이제 엄격한 기준에 따라 시험된다. 따라서 보트 이용자들은 이러한 경보기가 선내에서 겪는 더 가혹한 환경에서도 효과적으로 작동하도록 설계되었음을 안심해도 된다. 2.6.3 설치 요건 영국에서는 밤에 잠을 자는 용도의 레저 보트를 포함하여 레저 보트에 CO 경보기를 설치하여야 한다는 요건이 없다. RCD와 관련 조화 표준도, BSS 인증 절차도 신규 또는 기존 보트에 CO 경보기를 설치하도록 요구하지 않는다. CO는 가정이나 캐러밴에서와 마찬가지로 보트에서도 효과적으로 사람을 죽인다. 따라서 신규 캐러밴과 신규 주거 시설의 거주자에게 이미 제공되는 보호와 같은 수준으로 신규 보트의 레저 선원을 CO의 위험으로부터 보호하는 조치를 도입하는 것은 상식이어야 한다. RCD는 배기가스가 거주 구역에 이르는 것을 막기 위해 설계의 다른 요소에 의존하지만, CO 경보기의 설치는 재료의 파손이나 다른 장비 또는 설비의 오작동이 일어났을 때 생명을 구할 수 있는 간단하고 비용 효율적인 조치이다. 더욱이 CO 경보기는 모든 보트에서 화재 감지에 중요한 역할을 할 가능성이 있다(다만 CO 경보기가 있다는 것을 적합한 연기 감지기를 설치하지 않는 이유로 삼아서는 결코 안 된다). CO 경보기의 설치를 의무화하면 신규 보트가 취항함에 따라 시간이 지날수록 점점 더 많은 보트 이용자를 보호하는 데 도움이 될 것이다. 그러나 영국 내수면에서만도 현재 약 80000척의 레저 보트가 계류되어 있고, 영국 수로에서 CO 관련 사망이 발생하고 있음(1.15.2항)을 감안하면 기존 레저 보트의 소유주도 CO 경보기를 설치하는 것이 중요하다. 더욱이 해양 환경을 견디려면 설치하는 경보기가 EN 50291-2 표준을 충족하여야 한다. 현재 생산되는(그리고 EN 50291-2를 충족하는) 많은 독립형 CO 경보기의 유효 수명은 7년에서 10년 사이이며, 일부는 평생 밀봉된 배터리와 평생 보증이 있다. 보트에 자체 전원 공급에 의존하는 CO 경보기가 있다면 '독립형' 경보기도 예비로 함께 설치하는 것이 바람직하다. 이는 보트의 전원 공급이 끊어지더라도 탑승자가 보호되도록 보장할 것이다. 모든 경보기는 필요할 때 작동함을 보장하기 위해 누름 버튼 시험 기능으로 정기적으로 시험하여야 한다.
2.7'직접 하기(DIY)'의 위험 Arniston호의 소유주는 자격을 갖춘 배관공이었다. 따라서 발전기 배기 계통의 납땜 이음이 온수 계통에 사용하기에 적절한 수준이었던 것은 놀라운 일이 아니다. 또한 소유주는 배기 계통을 조립한 뒤 발전기에서 시험하였다. 그러나 이 시험은 발전기에 부하를 건 상태에서 이루어지지 않았다. 연납과 배관공용 피팅을 발전기 배기 계통에 사용하는 것이 전적으로 부적절하다는 점을 확인하는 데 필요한 온도가 발생하지 않았다.
따라서 시험 중에 배기 피팅은 파손되지 않았고, 이로 인해 소유주는 자신의 작업에 대해 잘못된 확신을 가지게 되었다. 이 사고에 대한 MAIB 조사 과정에서 윈더미어의 다른 보트 소유주 여럿도 밀폐된 공간에 휴대용 발전기를 설치하였음이 발견되었다. 많은 사람이 발전기를 직접 설치하였다. 직접 하는(DIY) 작업은 해양 레저 부문에서 매우 인기가 있으며 보트 소유의 즐거운 부분으로 여겨진다. 이는 보트를 운용하고 유지하는 비용을 줄이는 데에도 도움이 된다. 그럼에도 보트 소유주의 공학적·기계적 기술과 관계없이 자격을 갖춘 선박 기관 기술자만이 설치, 정비 또는 개조하여야 하는 계통이 보트에는 수없이 많다. 이러한 상황에서 선박 기관 기술자도 장비 제조사의 지침을 따르고 올바른 공구와 재료를 사용하여야 한다. 안전상 결정적인 작업을 마무리하기 위해 선박 기관 기술자를 쓰는 비용은 필연적으로 'DIY' 비용보다 많이 든다. 그러나 안전상 결정적인 계통에 관한 한 그러한 지출은 보트 소유 비용에 반영되어야 한다.
2.8보트 검사 BSS가 수행하는 보트 검사는 잠재적으로 위험한 CO 배출 설비를 찾아내고 부각하여 개선 조치를 취할 수 있게 하는 데 유용하다. 이 경우 배기관이 설치된 지 얼마 안 되어 파손되지 않았고 그동안 Arniston호가 BSS 인증 절차에 따라 검사를 받았다면 다음과 같았을 가능성이 있다. • 기관실이라는 좁은 공간에 휴대용 발전기를 부적절하게 사용한 것이 확인되었을 것이다. • 적절한 경고가 발부되었을 것이다. • Arniston호의 소유주는 연결이 끊어진 CO 경보기를 교체하라는 조언을 받았을 것이다. • Arniston호의 소유주는 '보트에서의 CO 안전' 리플릿(부속서 D)의 사본을 받았을 것이다. Arniston호 선내 사망 사고의 상황과, 윈더미어의 다른 선박에 휴대용 발전기가 설치되어 있는 정도를 함께 고려할 때, 호수의 관리 당국이 BSS나 이와 유사한 제도를 채택하면 향후 유사한 사고의 발생을 방지할 가능성이 있음이 분명하다.
2.9CO에 대한 인식 CO는 사람을 죽인다. 이 가스는 다양한 발생원에서 만들어지며 그중 일부는 다른 것들만큼 분명하지 않다. 가스, 기름, 석탄, 목재를 사용하는 가스 난로, 조리기, 온수기, 개방형 불과 같은 기기는 모두 CO의 발생원이다. 일회용 바비큐도 좁은 공간에서 사용하면 치명적일 수 있는 것으로 알려져 있다.
보트에는 CO 발생원이 많이 있음에도 많은 보트 이용자는 CO 중독의 위험을 알지 못한다. 이러한 위험은 밤에 잠을 자는 용도로 설비되고 사용되는 보트에서 아마 더 커질 것이다. CO 경보기가 없으면 CO의 존재가 확인되지 않으므로 이러한 인식 부족 때문에 CO 중독 사례가 다수 확인되지 못하고 증상이 다른 불특정한 질병이나 원인 탓으로 돌려질 가능성이 높다. CO의 발생원, CO 중독의 증상, 경보기 설치를 포함하여 CO의 위험에 대한 레저 보트 이용자들의 인식을 높이려는 BSS, CoGDEM 및 기타 기관의 활동은 매우 긍정적이다. 그럼에도 영국의 레저 보트와 레저 보트 이용자의 수(잠재적 위험에 노출된 인구)와 함께 1.15항에 상세히 기술된 과거의 사고와 사고 통계를 감안하면 더 많은 조치가 필요함이 분명하다.
, where the deceased were sleeping, reached life-threatening levels within 2 hours. [2.5] 9. The CO alarms fitted on board Arniston were over 7 years past their replacement date and they had been disconnected from the power supply. The absence of a functioning CO alarm in Arniston’s
accommodation
meant that a vital barrier to protect the boat’s occupants from the dangers of CO was missing. [2.6] 10. It is a common misconception in leisure boating circles that CO alarms are prone to ‘false alarms’ and that they are therefore not suitable for use in the
. [2.6] 11. There is no requirement for either new or existing recreational craft, including those intended for overnight sleeping, to be fitted with a CO alarm. It would be common sense for measures to be introduced to protect recreational mariners on new boats from the danger of CO to the same extent as the protection already afforded to occupants of new caravans and new dwellings. [2.6] 12. ‘DIY’ is very popular with recreational boaters, but there are numerous systems on
board boats that, regardless of a boat owner’s engineering and mechanical skills, should only be installed, maintained or modified by a qualified marine engineer following manufacturers’ instructions. [2.7] 13. Examinations under the
certification process could potentially help to prevent CO poisoning on board recreational craft operating on inland waterways. [2.8] 14. More needs to be done to raise the awareness of recreational boaters to the dangers of CO poisoning. [2.9]
한국어 번역 · 모델 · 검수 전
3절 결론
3.1사고에 직접 기여한 안전 쟁점으로서 해결되었거나 권고로 이어진 것 1. 사망자들은 기관실에 설치된 휴대용 발전기의 배기가스에 함유된 CO에 중독되었다. [2.2, 2.3] 2. 발전기의 외부 배기 계통이 치명적으로 파손되어 발전기의 배기가 보트의 측면 밖으로 나가는 대신 기관실로 직접 배출되었다. [2.2, 2.4] 3. 배기가스에는 높은 농도의 CO가 들어 있었고 공통 격벽의 틈새를 통해 기관실에서 보트의 거주 구역으로 퍼졌다. [2.2, 2.5] 4. 발전기가 사용하는 '농후한' 공기/연료 혼합기 때문에 발전기 배기가스의 CO 농도가 비교적 높았다. 이로 인해 발전기를 밀폐되거나 환기되지 않는 공간에서 사용하면 더욱 위험하였다. [2.3] 5. 휴대용 Hyundai 발전기는 대개 밀폐된 공간에서 사용해서는 안 되며 개조해서도 안 된다는 경고와 함께 공급되었다. Arniston호 선내 기관실에 휴대용 발전기를 설치하고 그 배기 계통을 연장하고 개조한 것은, 이 경우에 경고가 제공되었다면 그 경고를 보트 소유주가 따르지 않았음을 나타낸다. [2.3] 6. 외부 배기 계통을 제작하는 데 사용된 재료와 방법은 부적절하였고, 발전기를 전기 부하 없이 시험한 것은 비현실적이고 오해의 소지가 있었다. [2.4] 7. 휴대용 발전기에 장착된 외부 배기 계통은 목적에 부합하지 않았다. 그것은 기밀하지 않았고, 연납의 사용, 부적절한 압축 이음, 계통이 지지되지 않은 점 때문에 여러 곳에서 파손될 가능성이 있었다. [2.4] 8. 사망자들이 자고 있던 선미 선실의 CO 농도는 2시간 안에 생명을 위협하는 수준에 이르렀다. [2.5] 9. Arniston호에 설치된 CO 경보기는 교체 시기를 7년 넘게 지난 것이었고 전원 공급이 차단되어 있었다. Arniston호의 거주 구역에 작동하는 CO 경보기가 없었다는 것은 보트 탑승자를 CO의 위험으로부터 보호하는 필수적인 방벽이 없었음을 의미하였다. [2.6] 10. 레저 보트 이용자들 사이에서 CO 경보기가 '오경보'를 일으키기 쉬워 해양 환경에서 사용하기에 적합하지 않다는 것은 흔한 오해이다. [2.6] 11. 밤에 잠을 자는 용도의 보트를 포함하여 신규 또는 기존 레저 보트에 CO 경보기를 설치하여야 한다는 요건이 없다. 신규 캐러밴과 신규 주거 시설의 거주자에게 이미 제공되는 보호와 같은 수준으로 신규 보트의 레저 선원을 CO의 위험으로부터 보호하는 조치를 도입하는 것은 상식일 것이다. [2.6] 12. 'DIY'는 레저 보트 이용자들에게 매우 인기가 있으나, 보트 소유주의 공학적·기계적 기술과 관계없이 자격을 갖춘 선박 기관 기술자가 제조사의 지침에 따라서만 설치, 정비 또는 개조하여야 하는 계통이 보트에 수없이 많다. [2.7] 13. BSS 인증 절차에 따른 검사는 내수면에서 운항하는 레저 보트의 CO 중독을 방지하는 데 도움이 될 가능성이 있다. [2.8] 14. 레저 보트 이용자들이 CO 중독의 위험을 인식하도록 하기 위해 더 많은 조치가 필요하다. [2.9]
of periodic boat examinations, to explain to boat users, where present, the risk of
carbon monoxide
poisoning; highlight the potential sources of
carbon monoxide
; and promote the use of
carbon monoxide
alarms. The Lake District National Park Authority is recommended to: 2015/105 Adopt the
Boat Safety Scheme
as a means of improving safety on inland waterways for which the Lake District National Park Authority holds statutory responsibility. Safety recommendations shall in no case create a presumption of blame or liability
Marine Accident Report
한국어 번역 · 모델 · 검수 전
5절 권고
기업혁신기술부(Department for Business, Innovation and Skills)에 다음을 권고한다.
2015/102 EU 레저보트 지침(RCD) 체계를 통하여, 신조 선박에 거주 구역의 유독가스, 특히 일산화탄소를 감지하고 그 존재를 탑승자에게 경보하는 수단이 갖추어지도록 하는 방안을 모색할 것.
영국 내수면 보트안전제도(Boat Safety Scheme), 영국 해사연안경비청, 영국 왕립요트협회(Royal Yachting Association), 영국 해양산업연맹(British Marine Federation), 가스감지 및 환경감시위원회(Council of Gas Detection and Environmental Monitoring), 내수면 항행당국협회(Association of Inland Navigation Authorities)에 다음을 권고한다.
M2015/103 현재의 활동을 바탕으로 다른 관련 기관과 협력하여, 레저 보트 이용자 사회에 일산화탄소(CO)의 위험성과 일산화탄소 경보기 설치의 중요성에 대한 인식을 높이기 위한 조율되고 집중적인 캠페인을 수행할 것. 노력은 특히 다음 사항에 집중하여야 한다.
›일산화탄소의 발생 가능성이 높은 원인에 대한 인식 제고
›부적절하거나 잘못 설치된 화석연료 연소 장비를 사용하는 것의 위험성
›일산화탄소 중독의 초기 증상
영국 내수면 보트안전제도에 다음을 권고한다.
2015/104 소속 보트 검사관이 정기 보트 검사를 하는 동안, 보트 이용자가 현장에 있는 경우 일산화탄소 중독의 위험성을 설명하고, 일산화탄소의 잠재적 발생원을 짚어 주며, 일산화탄소 경보기의 사용을 장려하도록 독려할 것.
호수지구 국립공원관리청(Lake District National Park Authority)에 다음을 권고한다.
2015/105 호수지구 국립공원관리청이 법적 책임을 지는 내수면의 안전을 개선하는 수단으로 영국 내수면 보트안전제도를 도입할 것.
안전 권고는 어떠한 경우에도 과실이나 책임이 있다는 추정을 낳지 아니한다.
해양사고 보고서
그림 11: 그림 10과 같으며, 다른 카메라 각도에서 본 모습.원본 PDF 140쪽
그림 12: 그림 10과 같으며, 다른 카메라 각도에서 본 모습.원본 PDF 141쪽
42쪽 중 7쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 13: 그림 10과 같으며, 다른 카메라 각도에서 본 모습.원본 PDF 142쪽
그림 14: 직선 구리 이음쇠와 엔진 배기 접합부, 분해 전 TTH 접합부 맞춤 표시를 보여 줌.원본 PDF 143쪽
42쪽 중 8쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 15: 발전기 일체형 배기관 끝, 나사 고정구가 끼워져 있던 완전 관통 구멍 세 개를 보여 줌.원본 PDF 144쪽
그림 16: 구리관과 엔진 배기관 연결부의 나사 고정구(접합부 시계 방향 대략 위치를 괄호로 표시), 끝단의 그을음을 보여 줌.원본 PDF 145쪽
42쪽 중 9쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 17: 구리관 제거 후 발전기의 끝 덮개, 국부적인 응축수 부식을 보여 줌.원본 PDF 146쪽
그림 18: 구리 이음쇠의 설치 상태 기준 하부 쪽, 구리 이음쇠의 이 쪽에 응축수로 인한 녹 얼룩이 있음을 보여 줌.원본 PDF 147쪽
42쪽 중 11쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 21: 구리 이음쇠 및 45º 구리 엘보와 짧은 구리관 토막의 접합부, 접합부 측면에서 본 모습.원본 PDF 150쪽
그림 22: 구리 이음쇠 및 45º 구리 엘보와 짧은 구리관 토막의 접합부, 접합부 아래쪽에서 본 모습.원본 PDF 151쪽그림 속 글자 (3)
출구끝입구 끝
42쪽 중 16쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 31: 그림 30과 같으며, 소음기 상자의 반대쪽 면에서 본 모습.원본 PDF 160쪽
그림 32: 소음기 상자 배수 구멍에 있던 나사의 상세.원본 PDF 161쪽
42쪽 중 17쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 33: 분리된 접합부 및 45º 엘보로 이동한 구리관 토막 접합부, 사전에 적절히 젖음(wetting)이 이루어졌다는 증거를 보여 줌.원본 PDF 162쪽
그림 34: 그림 33과 같음.원본 PDF 33쪽
42쪽 중 19쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 37: 구리 엘보와 소음기의 접합부, 고정 나사와 접합부 실런트를 보여 줌.원본 PDF 35쪽
그림 38: 구리 엘보와 소음기의 접합부, 접합부 실런트를 보여 줌.원본 PDF 35쪽
42쪽 중 20쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 39: 분리된 접합부의 소음기 쪽, 관 내경의 그을음을 보여 줌.원본 PDF 36쪽
그림 40: 소음기 출구, 내경의 가벼운 그을음을 보여 줌.원본 PDF 36쪽
42쪽 중 25쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 49: 그림 48과 같음.원본 PDF 41쪽
그림 50: 가요성 호스의 소음기 상자 쪽 끝에 있는 조여지지 않은 주빌리 파이프 클립의 상세.원본 PDF 41쪽
42쪽 중 27쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 53: 가요성 호스의 선체 관통 쪽 끝, 느슨하게 조여지지 않은 주빌리 파이프 클립을 보여 줌.원본 PDF 43쪽
그림 54: 가요성 호스의 선체 관통 쪽 끝, 느슨하게 조여지지 않은 주빌리 클립과 클립의 "웜" 부분을 덮은 은색 호일 단열재를 보여 줌.원본 PDF 43쪽
42쪽 중 28쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 55: 가요성 호스의 선체 관통 쪽 끝, 클립의 "웜" 부분을 덮은 은색 호일 단열재를 보여 줌.원본 PDF 44쪽
그림 56: 그림 55와 같음.원본 PDF 44쪽
42쪽 중 29쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 57: 가요성 호스의 선체 관통 쪽 끝, 내경에 배기 그을음의 흔적만 있음을 보여 줌.원본 PDF 45쪽
그림 58: 분리된 납땜 접합부에서 실험실 시편 M1을 채취한 위치.원본 PDF 45쪽
42쪽 중 36쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 71: 현미경 사진(원본 이미지는 X100으로 촬영), 부식 처리하지 않은 시편. 그림 70의 상세, 필릿(fillet) 부위를 보여 줌.원본 PDF 52쪽
그림 72: 현미경 사진(원본 이미지는 X200으로 촬영), 부식 처리하지 않은 시편. 그림 70의 상세, 온전한 모세관 부위를 보여 줌.원본 PDF 52쪽
42쪽 중 37쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 73: 현미경 사진(원본 이미지는 X200으로 촬영), 부식 처리하지 않은 시편. 시편 M1, 접합부의 분리된 부위에서 구리 이음쇠에 대한 양호한 땜납 접합을 보여 줌.원본 PDF 53쪽
그림 74: 현미경 사진(원본 이미지는 X25로 촬영), 부식 처리하지 않은 시편. 시편 M2, 온전한 땜납 필릿과 잘 흘러든 모세관 부위를 보여 줌.원본 PDF 53쪽
42쪽 중 38쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 75: 현미경 사진(원본 이미지는 X100으로 촬영), 부식 처리하지 않은 시편. 그림 74의 상세, 필릿 부위를 보여 줌.원본 PDF 54쪽
그림 76: 현미경 사진(원본 이미지는 X200으로 촬영), 부식 처리하지 않은 시편. 그림 74의 상세, 접합부 모세관 부위에 소량의 구리 침입과 기공이 있음을 보여 줌.원본 PDF 54쪽
42쪽 중 39쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 77: 현미경 사진(원본 이미지는 X12.5로 촬영), 부식 처리하지 않은 시편. 시편 M2, 접합부의 반대쪽 면과 녹아 빠진 필릿을 보여 줌.원본 PDF 55쪽
그림 78: 현미경 사진(원본 이미지는 X200으로 촬영), 부식 처리하지 않은 시편. 그림 77의 상세, 접합부의 두 번째 모세관 부위가 잘 젖어 있음을 보여 줌.원본 PDF 55쪽
42쪽 중 40쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 79: 현미경 사진(원본 이미지는 X500으로 촬영), 부식 처리하지 않은 시편. 시편 M2의 젖음이 풀린(de-wetted) 부위의 상세이며, 땜납과 구리 경계면에 연속적인 납-주석-구리 금속간 화합물층이 있음을 보여 주어 적절한 젖음이 이루어졌음과 부합함.원본 PDF 56쪽
그림 80: 엘보와 소음기 상자 접합부 실런트를 특성 분석한 FTIR 스펙트럼.원본 PDF 56쪽
42쪽 중 41쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 81: 접합부 실런트의 FTIR 스펙트럼(위쪽)과 실리콘 수지의 라이브러리 스펙트럼(아래쪽).원본 PDF 57쪽
그림 82: 구리 엘보와 소음기 상자 접합부에서 떼어 낸 실런트 시료의 SEM 후방산란 전자 이미지, EDX 분석 영역 EDX 1과 EDX 2를 보여 줌 - EDX 스펙트럼은 그림 83과 84에 제시됨.원본 PDF 57쪽
42쪽 중 42쪽 의뢰인: MAIB, 사우샘프턴 SO15 2JU 및 컴브리아 경찰청(Cumbria Constabulary), 컴브리아 LA14 2LE 작업 참조번호: T31033 ARNISTON
그림 83: 앞서 그림 82에 제시된 영역 EDX 1의 SEM-EDX 스펙트럼.원본 PDF 58쪽
그림 84: 앞서 그림 82에 제시된 영역 EDX 2의 SEM-EDX 스펙트럼.원본 PDF 58쪽
T31033:
Cabin
Photograph 5
4. Dinette area
Photograph 6
Test Meter Location, remote testing point.
Photograph 7
Main
Cabin
Door
Photograph 8
Main
Cabin
Door Notice
Annex C Report on the investigation into
emissions from a Hyundai HY 3000SEi generator set used on board the Arniston
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
REPORT
on
INVESTIGATION INTO
CARBON MONOXIDE
EMISSIONS FROM A HYUNDAI HY 3000SEi GENERATOR SET USED ON BOARD THE ARNISTON
Dated
10 February 2014
by
Dr ○○, Fuels, Lubricants and Lubrication, Exhaust Emissions
On instructions of The
of the Department for Transport
and Cumbria Police
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Contents
Section Item Page No.
1.00 Introduction 4 1.01 Formal Details 4 1.02 Synopsis 4 1.03 Instructions 4 1.04 Disclosure of Interests 5 1.05 Appendices 5
2.00 Background to the Case and the Issues 6 2.01 The Relevant Parties 6 2.01.1 The
Marine Accident Investigation Branch
6 2.01.2 Cumbria Police 6 2.02 The Assumed Facts 6 2.03 The Issues to be Addressed 6
3.00 Technical Evaluation 8 3.01 Overview 8 3.02 Method 8
4.00 Results of Investigations 10 4.01 Background 10 4.01.01 Combustion 10 4.01.02 Lambda 11 4.01.03 Eltinge Chart 11 4.02 Ty pe Approval 11 4.03
MAIB
VOSA Emissions Tests 12 4.04 Cumbria Police VOSA Emissions Tests 12 4.05 Reconstruction 14 4.06 Modifications to Generator Set 15 4.07 As Received Condition 15 4.08 Exhaust Temperature Tests 17 4.08.01 Method 17 4.08.02 Loads 18 4.08.03 Results:
MAIB
Generator Set 18 4.08.04 Results: Arniston Generator Set 19 4.09
Engine
Examination, Arniston Generator Set 21 4.09.01 Introduction 21 4.09.02 Air intake 21 4.09.03 Choke Mechanism 21 4.09.04 Carburettor 23 4.09.05 Spark Plug 24 4.10 Exhaust System 24 4.10.01 Introduction 24 4.10.02 Good Design 25 4.10.03 Initial Installation Considerations 26 4.10.04 Exhaust Fabricated for Generator Used on the Arniston 27
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
5.00 Summary of Conclusions 29 5.01 Tampering 29 5.02 Generator Set
Carbon Monoxide
Emissions 29 5.03 Modifications to Arniston Generator Set 30
Appendices
1 Curriculum vitae consisting of qualifications, experience, appointments and specialty of the writer. 31
2 Instructions 32
3 Documents which have been considered 33
4 Figures 34
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
1.00 Introduction
1.01 Formal Details
My name is of . I am self employed as an independent consultant specialising in fuels, lubricants and lubrication and exhaust emissions.
I have been jointly instructed by the
Marine Accident Investigation Branch
of the Department for Transport (
MAIB
) and Cum bria Police to investigate the emissions of
carbon monoxide
from a Hyundai HY 3000SEi generator set.
1.02 Synopsis
On 1 April 2013 three people were aboard a motor boat, named the Arniston, overnight on Lake Windermere. Two of the people on board died from
carbon monoxide
poisoning. A Hyundai HY3000SEi petrol engined generator set had been installed in the
engine
compartment
of the Arniston.
The Hyundai HY3000SEi generator set comprises a
and generator mounted in a plastic housing. Such generator sets are free -standing and must be used outdoors. In this instance the generator set had been modified to accept fuel from an alternative supply, rather than its own built in tank, and the exhaust system had been modified to vent the exhaust outside the hull. In the event the modified exhaust system failed by falling apart. This would have resulted in exhaust gasses, including
carbon monoxide
, being emitted into the
engine
compartment
of the vessel.
Cumbria Police had the
carbon monoxide
emi ssions of the generator set measured at the VOSA test station at Milnthorpe, Cumbria, where they were found to be high compared to those of another Hyundai HY3000SEi generator set purchased and tested at the VOSA test station at Botley, Hampshire, on behalf of the
MAIB
.
The
MAIB
and Cumbria Police are investigating the circumstances surrounding the deaths of the people on the motor boat and of interest are the reasons for the observed levels of
carbon monoxide
emissions.
1.03 Instructions
I have received instructions from the
MAIB
and from Cumbria Police. The essence of the instructions is similar in that I was asked to investigate the possible reasons for the high level of
carbon monoxide
emissions emitted by the Hyundai HY3000SEi generator set installed and used on the Arniston on which two people died as a result of
carbon monoxide
poisoning.
The
MAIB
instructed me to discover if the emissions were typical of generator sets of this type, or, if they were not, what reasons there might be which would account for the high levels observed during a reconstruction and in tests carried out by VOSA on behalf of Cumbria Police.
Cumbria Police instructed me to carry out an investigation into the reasons for the observed levels of
carbon monoxide
emissions measured from the generator set. In particular I was asked to
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
determine whether or not the concentrations observed were caused by
and tear, by a malfunction, by a manufacturing factor or by interference, accidental or otherwise.
I was also asked to gi ve an opinion whether the siting of the generator in the condition it was in with the fuel and exhaust system set -up employed in the motor boat, posed an obvious risk of death to the occupants of the vessel. I was also asked to comment on the suitability of the design,
and materials used to fabricate the exhaust system
Further details of my instructions are presented in Appendix 2.
1.04 Disclosure of Interests
I have no personal interest in any party to this case other than being instructed by the
MAIB
and Cumbria Police.
1.05 Appendices
Appendix 1 contains details of my experience, qualifications, appointments and specialist field.
Appendix 2 contains my instructions from the
MAIB
and Cumbria Police,
Appendix 3 contains a
of the documents which I received from my instructing solicitors or other sources and which I have considered in forming my opinions and reaching my conclusions.
Appendix 4 contains the figures referred to in the text of my report.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
2.00 Background to Case and the Issues
2.01 The Relevant Parties
2.01.1 The
Marine Accident Investigation Branch
The
Marine Accident Investigation Branch
(
MAIB
) is part of the Department for Transport. It examines and investigates all types of marine accidents to, or onboard, UK ships worldwide, and other ships in UK territorial waters.
2.01.2 Cumbria Police
Cumbria Police are investigation the deaths of the people on the motor boat because the incident occurred on Lake Windermere which is part of Cumbria Police's area.
2.02 The Assumed Facts
In reaching my conclusions contained in this report I have assumed the following to be facts.
The generator was
with an electrical load of approximately 1 kW when the incident occurred.
During tests at the VOSA stations whe n the generators were described as being under load the applied load was 1 kW. The analysers use by the VOSA test stations were calibrated using reference gas mixtures so the results from the analysers can be relied upon.
2.03 The Issues to be Addressed
In this case there are four principal technical issues to be addressed.
The first issue is whether or not the
carbon monoxide
emissions measured from the Hyundai HY3000SEi installed in the Arniston were unusually high.
The second issue is to determine the reasons for the observed
carbon monoxide
emissions. In particular whether or not the observed emissions levels were caused by a manufacturing factor, normal
wear
and tear, lack of maintenance, or by any modifications made to the generator set. The generator set had in any case been modified to accept fuel from an alternative fuel tank and the exhaust system extended to
the exhaust gases outside the hull of the vessel. However I was asked to identify any other changes which might have been made which might have an impact on the
carbon monoxide
emissions.
The third issue to be addressed is the impact of the modifications to the fuel and exhaust systems on
carbon monoxide
emissions.
The fourth issue is the suitability of the modified exhaust system, particularly the design and materials used for fabricating it. I was asked to provide information on good practice in the design
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
and fabrication of an exhaust system and to compare those practices with the practices used to modify the exhaust system on the Hyundai HY3000SEi generator set on the Arniston.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
3.00 Technical Evaluation
3.01 Overview
I shall first give some brief background of terminology and pertinent matters relating to exhaust emissions from spark
(petrol) engines. This is intended to facilitate an understanding of the technical discussions later in my report.
Firstly I shall examine existing evidence in my possession relating to this case in order to a) understand the present state of knowledge and b) to discover any evidence which might point to possible reasons for the high
carbon monoxide
emissions reported on the generator set from the Arniston.
Following my evaluation of the evidence to date I shall run the
engine
and measure exhaust temperatures at a range of lo ads in order to generate information which might further assist in understanding the disintegration of the modified exhaust system.
The third phase of my investigation will be to progressively dismantle the generator set to seek reasons for the reported
carbon monoxide
exhaust emissions. As exhaust emissions are controlled principally by the air inlet system and the fuel system I shall concentrate my investigations on those areas. However I shall investigate any other areas of the generator set if it app ears that they might be having an impact on the exhaust emissions.
3.02 Method
I had access to two Hyundai HY 3000SEi generator sets. One was the unit from the Arniston which was involved in the incident on 1 April 2013, and the other was a new unit which had been purchased for comparative purposes by the
MAIB
. This will enable me to determine if my observations concerning the generator set from the Arniston are replicated by a similar generator set, or are essentially unique to the generator set from the Arniston. Where I have concerns regarding dismantling any part of the Arniston generator set I shall first carry out operations on the
MAIB
generator set to minimise the risk of destroying evidence.
The
carbon monoxide
emissions from the generator set from the Arniston had been measured previously during the reconstruction which took place on 23 to 25 September 2013 and by the VOSA station at Milnthorpe, Cumbria, on the instructions of Cumbria Police. I did not repeat the tests but I did assess them to form an opinion as to their reliability.
Similarly the
MAIB
had had the exhaust emissions from the generator set which it purchased measured at the VOSA test station at Botley, Hampshire. Again I did not repeat the tests but examined them to form an opinion as to their reliability.
The Arniston generator set exhaust system failed with an applied electrical load of 1 kW. However these generator sets are rated at 2.6 kW at 230 volts ac, so I shall carry out exhaust temperature tests at
and in approximately 0.5 kW intervals up to 2.5 kW. I shall do this for both the
MAIB
and Arniston generator sets with the econ switch in the `on' and in the `off' positions. I understand that the switch was in the `on'
at the time of the incident and during the reconstruction.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
In order to understand the operation of the controls of the generator set and in particular those of the
engine
I shall run the
engine
and observe the actuation of valves etc. so that I am aware of their
running
positions when I dismantle the
engine
. I shall take measurements where appropriate and where reference data is available for comparative purposes. To assist me with the latter I have obtained a copy of the Hyundai HY 3000SI/HY 3000SEi workshop manual dated November 2011 from the importer Genpower Ltd of Milford Haven.
I shall take photographs of relevant parts to record my investigation and to show my findings. These images are shown at Appendix 4.
I am not medically qualified so I am unable to make any comments on t he physiological effects of
carbon monoxide
on the body.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
4.00 Results of Investigations
4.01 Background
4.01.01 Combustion
In a
petrol engine
air and fuel are mixed in the carburettor and the mixture passes into the
engine
where it is ignited by the spark plug. It is the task of the carburettor to mix the air and fuel in the correct proportions. The chemically correct mixture of air and fuel is known as the stoichiometric air fuel ratio. For petrol it is taken as 14.7:1 (by mass) though it might vary very slightly from this depending on the exact composition of the fuel.
Ideally at the stoichiometric air fuel ratio all of the fuel is completely burnt and all the oxygen in the air is consumed. The result is, theoretically at least, only carbon di oxide and water as the exhaust products. In practice there will also be some nitrogen oxides and nitrogen from the air. (Nitrogen does not `burn' in these conditions but can combine with oxygen at the combustion temperatures (2000+ C) to form nitrogen oxides, principally nitric oxide, NO.)
In practice when fuel burns the gaseous products of combustion are a mixture of
;
carbon monoxide
and hydrocarbons from
together with nitrogen oxides from the reaction between nitrogen in the air and oxygen. There will also be nitrogen and possibly some oxygen.
As
carbon monoxide
is the emission of interest in this case further discussion will be limited to this gas.
The concentration of
carbon monoxide
in the exhaust gas will depend on the air fuel ratio. If the ratio is greater than 14.7:1 the mixture is said to be lean and oxygen will be found in the exhaust because it has not all been used by the petrol. The concentration of
carbon monoxide
will be low, of the order of parts per million, rather than percent, for good combustion.
If the air fuel ratio is less than 14.7:1 the mixture is said to be rich. There will be only a small amount of oxygen but potentially high concentrations of
carbon monoxide
. The actual concentration of
carbon monoxide
will depend on how rich the mixture is, the richer the mixture the more
carbon monoxide
is produced.
Petrol engines manufactured since 1993 for cars have been equipped with exhaust catalysts to reduce the exhaust emissions emitted to the atmosphere. These engines are fuel injected and, apart from recent stratified charge engines, operate at stoichiometric air fuel ratio. However industrial engines, such as these generator sets, are fitted with carburettors and no catalyst for reasons of cost and legislation not requiring low exhaust emissions. They are therefore inherently potentially high emitters of
carbon monoxide
.
Running
an
engine
at lean air fuel ratios improves fuel economy. However
running
at rich air fuel ratios, say about 12.5:1 to 13:1 gives maximum power output. The latter is desirable from a performance point of view when an
engine
has to respond to sudden loads. However rich mixtures invariably result in high
carbon monoxide
emissions (and high hydrocarbon emissions).
In order to start a
petrol engine
from cold some form of mixture enrichment is required. This is often referred to as the choke, as the air intake to the carburettor is literally choked by a
. In
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
some industrial engines the choke is manually operat ed, whilst in others it is automatic. In the case of these Hyundai HY 3000SEi generator sets the choke is automatically controlled by a vacuum system.
4.01.02 Lambda
A value known as lambda is often used when describing air fuel ratios. It is defined as the actual air fuel ratio divided by the stoichiometric air fuel ratio. For a stoichiometric air fuel ratio lambda equals 1. For a lean mixture lambda is greater than one and for a rich mixture it is less than one.
4.01.03 Eltinge Chart
The Eltinge Chart (Document 7 and Figure 1) is a graph which was developed to enable the air fuel ratio to be determined from the concentrations of
carbon monoxide
,
carbon dioxide
and oxygen in an exhaust sample. The Eltinge chart is valid only for raw exhaust f rom a
petrol engine
measured as it is emitted from the
engine
.
The chart is used by
engine
test laboratories to verify the result obtained during a raw exhaust emissions test. If the results for
carbon monoxide
,
carbon dioxide
and oxygen are plotted on the Eltinge Chart the results should coincide at a single point. In practice, because of experimental error, the results produce a small triangle. A laboratory will set a limit to the size of triangle formed as the cut off for acceptable results and tho se results which prompt an investigation into the performance of the exhaust gas analysers and sampling system.
The Eltinge Chart is very useful for not only verifying the reliability of exhaust emissions results from petrol engines, but if the air fuel ratio is known from another source it can be used to give an indication of the likely concentration of
carbon monoxide
in an
engine
's exhaust.
4.02 Type Approval
It is a legal requirement in the EU that engines have to be type approved before they can be sold. This means that they have to meet the appropriate parts of various ECE Regulations (European regulations based on EU Directives). If they do a certificate is issued by the appropriate national body, in the case of the UK the Vehicle Certification Agency, VCA. The certificate bears a reference number which must be shown in some specified way on the
engine
. The certificate for the 157F
engine
fitted to these Hyundai generator sets is shown at Document 1. The certificate contains critical design d etails which must be retained for the certificate to be valid and the engines legally sold.
The measurement of exhaust emissions are part of the certification process. The emissions are measured at specified
and load conditions and then `averaged' in a defined way to give a value in g/kW.hr for the test. It is not possible to convert the certification value to a concentration from a particular
engine
under any specified operating condition.
Fuel flow and, for spark
ignition
engines, air fuel ratio have to be specified. In the case of the 157F
engine
the value for the air fuel ration is given as 13.3:1 at
,
. From the Eltinge chart this air fuel ratio would indicate a
carbon monoxide
concentration in the exhaust at
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
this condition of a little over 3%. This information indicates that the
engine
is set up with a rich mixture. This is technically sensible in that maximum power is developed with rich mixtures and a generator needs to be set up to respond to sudden loads imposed by connected electrical equipment being switched on. However, as can be seen from the Eltinge chart, rich mixtures can result in very high emissions of
carbon monoxide
(and hydrocarbons).
In view of the information contained in the type approval certificate I should expect to see relatively high concentrations, 3% or more, of
carbon monoxide
from this
engine
.
4.03
MAIB
VOSA Emissions Tests
The
MAIB
had the exhaust emissions from its generator set measured at the VOSA test station at Botley, Hampshire. The emissions measured were
carbon monoxide
,
carbon dioxide
and hydrocarbons. From this data lambda was calculated. This calculation would have been carried out automatically by the measurement equipment and displayed on the printout. A copy of the printouts is shown at Document 5.
I understand from the
MAIB
that the generator was operated at
no load
and with a load of nominally 1 kW.
I noted that the values of lambda shown on the printouts ranged from 2.334 to 3.293 when the generator was loaded and fr om 6.367 to 6.757 when under
no load
. From the lambda values I calculated the air fuel ratios to be from 34:1 to 48:1 and from 93:1 to 99:1 respectively. These results are not credible. The leanest air fuel ratio at which a
petrol engine
can operate is about 20:1 (lambda = 1.3). Even then lean misfire is likely to occur and possibly stalling if a sudden load is applied.
When I examined the generator set supplied to me by
MAIB
I noted that there was a spark arrestor fitted to the outer end of the
stub. This comprised a wire
. The presence of this
mesh
would prevent the exhaust analyser set probe from entering the
exhaust pipe
. The analyser set is equipped with a
to draw the gas sample into the analysers. If the probe is not inse rted a sufficient distance into the
exhaust pipe
the sample probe will suck in ambient air. This has the effect of diluting the sample of exhaust gas to showing excessively high levels of oxygen which results in the high values of lambda. I have therefor e disregarded the exhaust emissions data obtained by the
MAIB
at the Botley VOSA test station.
The only conclusion which can be drawn from these results is that
engine
was most likely emitting a greater concentration of
carbon monoxide
than that recorded during these tests. It is not possible to quantify the actual concentration of
carbon monoxide
in the exhaust at either test condition.
4.04 Cumbria Police VOSA Emissions Tests
Document 6 shows the results of exhaust emissions tests carried out at the VOSA test station at Milnthorpe on the Arniston generator set. I understand that the tests were carried out without any load applied and with a load of nominally 1 kW.
The sequence of
no load
, with load and a repeat of the
no load
condition shows good practice to identify any
in the
engine
's emissions during the period of the test.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
The lambda for the
no load
condition varies between 1.523 and 1.639 for the initial tests and was 1.68 for the repeat test. As noted in section 4.03 of this report a
petrol engine
will not run at a lambda of greater than 1.3 (air fuel ration not greater than 20:1). These results very strongly show me that the sampling procedure was flawed in that the sample probe was not inserted far enough into the
exhaust pipe
to obtain a proper sample of exhaust gas. Instead the analysers were measuring a mixture of exhaust and diluting ambient air.
In the case of the
MAIB
generator there was a spark arrestor preventing proper insertion of the sample probe. As part of the
of the exhaust system on the Arniston generator the spark arrestor had been removed. The stub pipe on these Hyundai engines is approximately 60 mm long. With the extension pipe, left on the Arniston generator set following the reconstructi on, the total end pipe length was 85 mm. Because of the pulses of exhaust gas coming out of the exhaust system the very end of the pipe will contain a mixture of exhaust gas and air, which is why it is critical to insert the probe sufficiently to avoid th e volume where the exhaust gas is diluted. Added to this is the fact that VOSA test stations are normally long large buildings so that heavy duty vehicles can drive through during the testing process. The doors are often left open at both ends to minimise the build up of exhaust gases from the vehicles being tested. The buildings are therefore often draughty. In my opinion it is almost certain that the probe was not taking a representative sample of exhaust gases and was therefore showing carbon monoxi de levels well below the actual emissions from the
engine
.
Since the final
no load
test results were similar to the first two results it is more rather than less likely that the tester was consistent in the probe
position
.
With regards to the three tests carried out with the generator set under load the lambda values recorded were 0.965, 0.895 and 0.836. It appears that either the mixture was getting richer over the six minutes as the tests proceeded or the conditions around the probe were changing. Th e hydrocarbon emissions show the same trend as would be expected. I calculated the air fuel ratios to be 14.2, 13.2 and 12.3 respectively which area about what I should expect to see.
The tests show concentrations of
carbon monoxide
of between 7.12 and 8.19%. These results are extremely high indicating an air fuel ratio richer than 12:1. These results are not consistent with the calculated lambda values. I attempted to plot the
carbon monoxide
,
carbon dioxide
and oxygen emissions on an Eltinge chart. The results were outside plottable ranges which must raise doubts over the reliability of the results. Because the algorithm for calculating lambda is `hidden' in the analysis system I cannot comment on whether or not the concentration of one of the other measured gases was having the effect of distorting the calculated value of lambda.
When the generator is run under load the
is increased by the generator's control system. This results in more gasses
through the exhaust system. I t is therefore likely that the effects of ambient air dilution might be less at the higher load making the emissions results more reliable.
On balance it would be my opinion that the
carbon monoxide
emissions levels recorded were semiquantitatively repres entative of the actual emissions. In my opinion it is not possible to reliably quantify the actual concentration of
carbon monoxide
in the exhaust at either test condition from these test results.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
4.05 Reconstruction
A reconstruction was performed at , on 23 to 25 September 2013. As part of the reconstruction
carbon monoxide
concentrations were measured by at various locations. Most of the reconstruction involved measuring the concentration of
carbon monoxide
around the internal parts of the Arniston.
The
carbon monoxide
emissions from the generator set were measured under
no load
on 24 September 2013 and under load on 25 September 2013 (Document 12). The four results with
no load
can be summarised as the generator set emitting between 2.87 % and 4.54 %
carbon monoxide
, with an average of all four readings of 3.93 %
carbon monoxide
. I note that results of readings 2 to 4 were in the range 3.89 % to 4.54 %, the average of which would be 4.28 %
carbon monoxide
.
I watched the video of the reconstruction, taken from Exhibit BS/344176, to study the sampling method. I noted that in one instance the sample probe was held at right angles to the
exhaust pipe
outlet and in another at an oblique angle and barely inserted into the end of the
exhaust pipe
. This method risks the drawing in of ambient air thus giving spuriously low results for the
carbon monoxide
concentration. The difference in the observed readings might be accounted for by the different sampling positions.
On 25 September 2013 a test was carried out to measure the
carbon monoxide
emissions from the generator set operated under load. The three results taken over the four to five minutes of testing were unusually and remarkably consistent, all being 4.56 %. Again I examined the video of the reconstruction taken from Exhibit BS/344177. In this instance the sample probe was inserted into the end of the
exhaust pipe
to collect a sample away from the end where the pressure puls es of the exhaust gasses would tend to draw fresh air around the sample probe, thereby diluting the exhaust gas concentrations and giving spuriously low results.
It appears therefore that at the load the
engine
was tested, and under the ambient conditions, the
carbon monoxide
concentration in the exhaust was 4.56 %. To put this figure into context the MOT test has a requirement for the
carbon monoxide
emissions at idle to be below a certain limit. For current catalyst cars this limit is defined by the ve hicle manufacturer. Before the advent of catalysts there was the option for the manufacturer to provide the limit to be met. However for older vehicles whose type approval did not require the in service
carbon monoxide
level to be specified, the default limit for the concentration of
carbon monoxide
at idle is 4.5 %. At this time engines were fitted with carburettors and so were of a similar technology to this Hyundai
engine
except that carburettors were generally a little more complex in order to obtain the good drivability demanded for an
engine
in a vehicle.
When comparing the VOSA results with those obtained during the reconstruction there is a significant discrepancy, 7 -8 % versus 4.5% respectively. Without investigating the details of the analysis equipment used by VOSA and its calibration, and the effects of possible interferences of petrol derived exhaust gas components on the
carbon monoxide
analysers used during the
construction
I cannot offer a substantiated reason for the difference. However it is my opinion from this data that the
engine
was
running
rich and was probably emitting between 4 and 8 %
carbon monoxide
. These levels are extremely high.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
4.06 Modifications to Generator Set
The generator set as supplied by the importer is fitted with an integral fuel tank. In the case of the generator installed in the Arniston the integral fuel tank had been removed and an alternative fuel supply pipe, with a priming bulb and bayonet end
on the inlet end, fitted in its place. This new pipe bypassed the standard fuel cut off switch and was connected directly to the inlet side of the generator set's
. A metal clip secured it to the inlet stub of the
pump
as shown in Figure 2. The fuel pipe bore the markings 3/16" Fuel hose, SAE J30 R6 indicating that it is suitable for use with unleaded petrol.
It would have been necessary to remove the casing completely to enable the fuel tank to be removed. The two parts of the casing are secured by six
/nut assemblies. The
screw
an d nut at the
front
position
was missing Figure 3.
I was supplied with a metal fuel tank which I understand was placed in a
compartment
on the Arniston just to the rear of the
engine
compartment
. The tank bore the name Volvo Penta, the marine division of Volvo. The tank is a typical marine tank which can be removed for refilling on land. It has a bayonet type outlet, to prevent fuel spillage when disconnecting the fuel pipe, and a fuel gauge. This particular tank also had a 0.5 l
for filling with two stroke oil when the tank is to be used on a two stroke
engine
. The Hyundai
engine
is a four stroke
engine
, not a two stroke unit, so the tank was empty.
The gauge on the fuel tank showed the tank to be between ¾ and full, Figure 4. For my tests on the Arniston generator I used the fuel contained in the Volvo Penta fuel tank.
In my opinion it is unwise, for safety reasons, to bypass the fuel cut off switch. In the installation on the Arniston it would be possible to stop fuel flow to the
engine
by disconnecting the bayonet
coupling
at the fuel tank. However the
engine
and fuel tank were in different compartments so it would not have been possible to cut off the fuel within the
engine
compartment
.
The generator set as originally supplied is fitted with a blue plastic full casing to reduce noise emissions. The casing is fitted with access panels held in place by screws. Access panels exist for the battery
compartment
, one for routine maintenance such as checking the oil, cleaning the ai r filter etc and one allowing access to the spark plug. In addition there is a vented safety cover which allows cooling air to the
engine
and protects the user from contact with the hot exhaust silencer. A spark arrestor, comprising a wire
mesh
is fitted over the end of the exhaust stub pipe.
When I received the Arniston generator set the battery
compartment
and exhaust safety covers were missing, Figures 5 and 6 respectively.
4.07 As Received Condition
When I received the generator set from the Ar niston two panels were missing as noted in section 4.06. I took photographs of the generator set as a whole. The unit number was recorded on a label as HYK 311120002199
The remote switch was in the `on'
position
as was the econ switch. There was no key supplied to enable a key start. A wireless remote was provided in an exhibit bag exhibit no JAM/9. I did not test or use the remote wireless start during my investigations.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Before
running
the
engine
I checked to make sure that it was in a condition that no damage should be caused to it by its being run.
I removed the maintenance cover and noted the
engine
number which was XG11121287, the
engine
type number which was 157F and the type approval number which was e11*97/68SA*2004/26*0910*00, Figures 7 and 8 respectively. This is the same number as cited on the type approval certificate supplied to me (Document 1).
I visually examined all clips for security. I noted that the clip on the inlet side of the fuel filter had been moved from its original
position
as shown by residual marks on the rubber fuel hose, Figure 9. The clip which was supposed to retain the fuel hose on the outlet side of the fuel filter was sitting loose around the pipe downstream of the stub on the fuel filter, Figure 10. In this
position
the clip would not
the pipe in place and its retention would depend solely on the friction of the pipe on the fuel filter stub. I flexed the connection and decided that the joint was sufficient for the purposes of my tests only. During testing I checked it at frequent intervals for movement.
There was no evidence of
engine
oil in the
bottom
of the casing below the filler/level checking neck. I checked the oil level and found it to not be at the maximum level (the top of the filler neck) but part way down the filler neck. I decided that the
engine
clearly had sufficient oil for its safe
running
for the duration of the test programme, Figure 11. I did not want to add or use another oil as this might influence any subsequent results.
I check ed the battery and found that the wire terminal on the negative lead had become disconnected and was attached to the battery. There was also evidence of loose strands of wire at the positive wire terminal and the joint appeared to have been re -crimped at some stage, but not using both pairs of tags on the terminal as should be the case, Figure 12.
Neither the positive nor the negative terminals were securely tightened to the battery terminals. There was corrosion present on the negative terminal. I c leaned this to ensure good electrical connections.
There were no insulating covers protecting the battery terminals. This lack of insulators is a potential hazard as there is no protection to avoid shorting the battery terminals which can cause sparking. I compared the Arniston generator with the
MAIB
generator. The latter had protective covers fitted, Figure 13.
I re -crimped the wire terminal onto the negative supply lead, Figure 14, and refitted the supply leads to the battery and wound the exposed electrical parts with insulation tape, Figure 15.
I subsequently found the red, positive, terminal cover loose in the generator set casing. I placed it in an exhibit bag labelled Exhibit HCS/ 2.
I checked the battery voltage which was 12.7 V on open circ uit. I connected the battery to a CTek MXS 5.0 battery charger/tester. This showed that there was sufficient energy in the battery to start the
engine
. I allowed the battery to be charged to its full capacity to avoid later electrical problems or variable loads caused by the battery being charged.
When attempting to refit the battery I noted that part of the retaining strap was missing so the battery could not be properly secured in its L shaped base.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
I noted that there was an electrical box secured u sing a cable tie to the base on which the fuel tank would normally have sat, Figure 16. I believe that this is the wireless receiver/control unit for the remote wireless start. It is normally located between the back of the control panel and the fuel tank on the right hand side as viewed from the front.
I took the key supplied with the
MAIB
generator to use to key start and stop the Arniston generator. It was apparent that the internal plastic retainer in the run/stat key switch was displaced preventing key operation. There were marks on the plastic possibly indicating the use of some other device to operate the generator, Figure 17. I realigned the sleeve so that I could use the key so as to be able to control the generator from the key rather than by remote. It appears from the video of the reconstruction that stop and start were carried out using a wireless
.
I visually examined the carburettor and choke arrangement for leaks. There were none. I did notice a witness mark on the rod of the diaphragm assembly, Figure 18. This rod is connected to a stranded wire and operates the choke plate. The witness mark indicates that the rod had been rubbing on the casing or the diaphragm. I did not investigate this further at this stage to avoid changing any settings.
On checking the underside of the generator I recovered some silver adhesive tape. I retained this as exhibit HCS/1.
4.08 Exhaust Temperature Tests
4.08.01 Method
The object of this test is to measure the temperature of the exhaust gas from the Arniston generator set at a range of electrical loads including
no load
and nominally 1 kW. I carried out two series of tests, one with the econ switch in the `on'
position
and the second with the econ switch in the `off'
position
. The econ(omy) switch is intended to enable the generator set to run at a lower
speed
. This not only reduces noise but also fuel consumption.
In each case I commenced with
no load
and increased the load in steps of nominally 0.5 kW to a maximum of 2.5 kW. (The rated output of the generator set is 2.6 kW.) This sequence ensures that the temperature of the exhaust system increases in steps and avoids residual heat from previous higher load operation. I carried out the tests first with the econ switch on and then off for the same reason. Once these tests were finished I allowed the
engine
to cool until the inside face of the silencer at the inner end of the exhaust stub pipe was below 120 C, i.e. below the exhaust temperature at
no load
.
Exhaust temperature is very sensitive to location. For comparable results it is necessary to use a fixed, defined
position
. To achieve this I used a rigid K type thermocouple attached to a Robin RT 550 digital thermometer. I measured the length of the stub pipe which was 60 mm. I marked the thermocouple body at 35 mm, at 60 mm and at 85 mm, Figure 19. The 35 mm mark gave a repeatable
position
part way (35 mm) into the
exhaust pipe
whilst the 60 mm mark gave a
position
at the inner end of the stub pipe for the standard
MAIB
generator set. The 85 mm mark gave the inner end of the stub pipe having taken account of the copper extension fitted to the Arniston generator set during the reconstruction.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
I carried out the testing first using the
MAIB
generator set and th en using the generator set from the Arniston.
In addition, for the Arniston generator, set I fitted a reflective tape to the rear face of the fan located just in front of the exhaust muffler. This enabled me to use a Kent Moore infra red digital tachometer to measure the rotational
speed
of the
engine
. I was unable to obtain sensible
speed
values from the
MAIB
generator as there appeared to be some reflection from the fan disc itself thereby sometimes indicating twice rotational
speed
.
4.08.02 Loads
In order to apply loads to the generator sets I obtained heaters of nominal power consumptions of 250 W, 400 W, 500 W and 1.5 kW. I connected each to a 230 volt ac supply and measured the current consumption using a Kewtech KT71 PAT Tester. From this I c alculated the actual power consumed. The values obtained were 209 W, 370 W, 444 W and 1.444 kW respectively. I selectively connected the heaters to give loads of 0.444 kW, 1.023 kW (444+370+209), 1.444 kW 2.023 kW (1444+370+209) and 2.467 kW (all loads together). I verified the output voltages of the generators as: the Arniston generator, 225.6 V and the
MAIB
generator 233 volts. The slight variations from 230 volts introduce an error of less than 2 %. Since accuracy of the applied load was not a critical parameter I accepted this error.
4.08.03 Results:
MAIB
Generator Set
The results I obtained for the
MAIB
generator set are shown in table 1.
Econ Switch
Position
Load kW Temperature 35 mm into exhaust system C Temperature 60 mm into exhaust system C on 0 150 not measured on 0.444 196 not measured on 1.023 272 not measured on 1.444 349 not measured on 2.023 435 - 442 not measured on 2.467 (*) (*)
off 0 157 204 off 0.444 143 226 - 236 off 1.023 148 270 off 1.444 305 - 318 354 - 358 off 2.023 393 - 405 458 - 468 off 2.467 412 - 418 459 - 470
Table 1 Results of exhaust temperature tests on
MAIB
generator. Ambient temperature 4 C. Note: * see text
I found initial starting of this generator set to be difficult. I removed the mainten ance cover to examine the choke operation. I noted that the choke was pulling off almost as soon as the
engine
first fired. This would have left too weak a fuel mixture for continued
running
. I therefore
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
manually held the choke closed to start the
engine
and subsequently let the
engine
warm up for 15 minutes under
no load
prior to testing.
When applying the 2 kW load when the econ switch was in the `on'
position
the overload warning light initially illuminated, but then extinguished and the
engine
continued to run. However when the 2.5 kW load was applied the overload warning light illuminated and remained illuminated. The generator continued to run but did not supply any electrical output. It was therefore not possible to obtain a meaningful exhaust temperature reading. With the econ switch in the on
position
the exhaust temperatures increased with increasing load as would be expected.
During this testing I noted that the
engine speed
was not constant with load but the control system increased the
engine speed
to provide more load. I examined this further when
running
the generator set from the Arniston.
When testing with the econ switch in the `off'
position
I noted unexpectedly low exhaust temperatures at the 0.44 and 1 kW loads. Investigations involving screening the exhaust showed that external air currents were causing cooling of the exhaust gas at the measurement point. To overcome this I carried out a set of measurements with the temperature probe inserted 60 mm, i.e. to the inner end of the exhaust stub. Temperature readings became more stable and consistent with what would be expected. I recorded both sets of results. At higher loads it can be seen that at 35 mm deep the temperatures are still fluctuating, but, because of the higher ex haust temperatures and gas flow rates, they become less affected by the external air currents.
Using a surface thermocouple I measured the temperature of the exhaust muffler outer surface adjacent to the stub pipe and the outer surface of the stub pipe adjacent to the muffler surface at 2.5 kW load. The temperatures I recorded were 257 C and 235 C respectively.
At the end of testing I observed a strong smell of newly hot
engine
. I suspect that this was the first time that the
engine
had been run under anything but a relatively light load. That being so the
engine
was not fully run in and I should expect further testing on this
engine
to yield different exhaust temperatures until the unit was fully run in. This might also account for the
engine
's reluctance to not operate at higher loads with the econ switch on.
I note that the exhaust gas temperatures I recorded were, as I should expect, well above the melting range of the solder used when modifying the exhaust system on the generator used on the Arniston.
4.08.04 Results: Arniston Generator Set
I warmed the
engine
for 15 minutes under
no load
prior to testing. The
engine
started easily with the choke pulling off slowly to enable the
engine
to continue to run following initial firing.
As I had noted variable
engine speed
when testing the
MAIB
generator set I took
engine speed
measurements during this set of tests.
The results I obtained for the Arniston generator set are shown in table 2.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Econ Switch
Position
load kW
Engine Speed
rpm
Temperature 60 mm into exhaust system C Temperature 85 mm into exhaust system C on 0 3128 113 - 115 133 on 0.444 3280 - 3317 157 - 159 184 - 187 on 1.023 3942 - 3967 249 - 252 278 - 281 on 1.444 4332 - 4346 280 - 281 334 - 336 on 2.023 4860 - 4905 395 - 400 422 - 425 on 2.467 4930 - 4947 488 - 496 518 - 524 0 3143 - 3160
off 0 4290 - 4308 183 - 185 219 - 221 off 0.444 4260 - 4277 231 - 232 259 - 260 off 1.023 4481 - 4491 313 - 315 343 - 346 off 1.444 4750 - 4771 336 - 338 370 - 371 off 2.023 4890 - 4913 415 - 417 443 - 447 off 2.467 4930 - 4948 477 - 486 518 - 521 0 4299 - 4314
Table 2 Results of exhaust temperature tests on Arniston generator. Ambient temperature 5 C.
After testing with the economy switch in the `on'
position
I noted carbon deposits on the end of the thermocouple indicating rich
running
. I wiped the end on a Kimwipe Precision Wipe and bagged the wipe as Exhibit HCS/2. Figure 20 shows the deposit on the wipe. I had wiped the thermocouple prior to starting the test.
Using a surface thermocouple I measured the temperature of the exhaust muffler outer surface adjacent to the stub pipe and the outer surface of the copper tube extension piece on the stub pipe adjacent to the muffler surface at 2.5 kW load. The temperatures I recorded were 163 C and 231 - 236 C respectively with the econ switch in the on
position
.
I repeated the test with the econ switch in the off
position
and at 2.5 kW load and at 1 kW load. The temperatures I recorded at 2.5 kW load on the outer surface of the muffler adjacent to the stub pipe was 113 C and on the outer surface of the copper tube extension piece on the stub pipe adjacent to the muffler surface was 155 – 158 C. The temperatures I recorded at 1 kW load on the outer surface of the muffler adjacent to the stub pipe was 116 - 118 C and on the outer surface of the copper tube extension piece on the stub pipe adjacent to the muffler surface was 138 – 141 C.
It is clear from these tests that the econ switch has the effect to reducing the
engine
's
running
speed
but only at loads up to about 1.5 kW. The greatest effect of the switch on
speed
is at
no load
.
The results also show that the exhaust temperature decreases relatively quickly once it comes into contact with cooled surfaces. It s hould be noted that during these tests the ambient temperature was 5 C. On the Arniston, where the generator was being run in a
, ambient temperatures would be elevated and exhaust component surface temperatures would also be elevated compared to the results obtained during these tests.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
When listening to the
engine
running
the sound did not appear constant. During
running
I removed the maintenance cover to examine the throttle movement. On the Hyundai HY 3000SEi generator set the throttle
position
is controlled by a stepper motor linked into the generator part of the unit. The throttle was continually changing its
position
. This leads to variations in load and
engine speed
. The latter is shown in table 2. Changing the throttle
position
affects the mixture strength. Generally repeated changes result in richer average mixtures as the mixture has to be enriched to enable the
engine
to accelerate.
4.09
Engine
Examination, Arniston Generator Set
4.09.01 Introduction
Following the exhaust temperature tests I examined the
engine
in some detail. As this involved removing some parts I chose to carry out this work after all
engine
running
tests. The main components which affect mixture strength are the carburettor and air inlet systems. The condition of the spark plug can give information regarding combustion.
4.09.02 Air intake
A blocked air filter will restrict the flow of air into an
engine
which results in the mixture become richer.
I removed the air filter element by removing th e access cover and pulling out the element itself. The filter element appeared clean with no evidence of blocking. I tapped the filter on a clean sheet of white paper. No particles were deposited on the paper which would be expected for a partially blocked filter. I also shone a light through to ensure that there were no areas which were blocked whilst others were clear. There was no evidence of blocking. Figure 21 shows light clearly
passing
through the filter.
4.09.03 Choke Mechanism.
In order to enable a
petrol engine
to start from cold the mixture strength has to be increased, i.e. made richer. The reasons for this are associated with the volatility of the fuel and the design of the intake system.
On some industrial engines the choke is manually operated, but on the Hyundai HY 3000SEi generator set the choke is automatic. In essence the choke plate, which reduces the amount of air entering the carburettor, is connected via a stranded wire to a diaphragm actuator. The actuator consists of a rod, to which the stranded wire is attached at one end, and a diaphragm at the other end. The diaphragm is held in a
housing. The side of the diaphragm opposite to the rod is connected, via flexible tubes and a check
valve
, to the
engine
. A s the
engine
's
goes up and down it creates a reduced pressure in the
manifold
which causes the diaphragm to move thereby moving the choke plate and un- choking the
engine
. In this particular arrangement the choke is held in the closed (i.e. start)
position
by a spring and the
causes the choke to open.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
For the purposes of adjustment of the choke system the stranded wire is clamped by two
screw
clamps, one at each end.
I noted when I was
running
the
engine
that there were witness marks on the rod indicating that it was rubbing against the diaphragm housing, Figure 18. I therefore checked the system for free movement. There appeared to be no restriction to fee movement.
When the choke was pulled off during starting I observed that the end of the stranded wire stopped against the body of the diaphragm housing, Figure 22 which had left a mark on the housing. It is usual to allow free movement of the connection system and control the choke plate movement by means of a stop on the choke lever arm. I therefore investigated this further by removing the outer casing completely to gain better access to the mechanism.
I removed the air filter cover to gain good visual access to the choke plate. I found no evidence of the air filter housing its elf having been removed previously. There were also no marks on the air cleaner to carburettor screws which would indicate that the carburettor had not been removed, Figure 23.
There is a single post on the carburettor body which acts as a stop for the choke lever arm, on one side setting fully closed and on the other side the fully open (
running
)
position
. I observed that the wire's abutting the diaphragm casing was preventing the choke plate from
fully. I measured the gap between the lever arm and the stop using feeler gauges. The gap was 1.5 mm. Figures 24 to 28 show the effect of this on the
position
of the choke plate and the presence of the gap between the stop post and the lever arm.
The fact that the choke does not open fully would ha ve the effect of making the mixture richer than it was designed to be.
My instructions from Cumbria Police were that I should retain forensic opportunities. I therefore did not release the two adjusting screws on the stranded wire to see if there was one indentation caused by the
screw
, or two at one or other end. If there were one indentation at each end I would draw the conclusion that the adjustment was as it left the manufacturer. If more than one indentation were present at either end I would concl ude that the choke mechanism had been adjusted post manufacture, either by the importer when checking the unit before delivery, or by someone subsequently.
I examined the same parts of the generator set supplied by the
MAIB
. It showed exactly the same characteristic, apart from the witness marks, with the choke not
opening
fully. In this case I measured the gap between the stop and the lever arm to be 2.6 mm. In my opinion this evidence suggests that the choke operating mechanism may be maladjusted before it reaches the first user.
I checked the integrity of the diaphragm itself by connecting a `Mityvac' vacuum
pump
. The choke opened at a
depression
of 20 kpa and showed no signs of leakage, Figure 29. This
opening
pressure is, in my opinion, appropriate.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
4.09.04 Carburettor
The carburettor mixes fuel and air in the required proportions. Factors affecting this mixing are the main jet, emulsion tube and the level of the fuel in the float chamber. I investigated these parameters.
I could find no evidence of the carburettor having been removed. The edges of gaskets were intact and there were no tool marks on the screws holding the air cleaner housing to the carburettor. This housing would have to have been removed to remove the carburettor.
I r emoved the float chamber bowl by draining the fuel and releasing the centre bolt. Inside the bowl were traces of a gritty material, Figure 30. This is not unusual. Grit getting into the carburettor usually causes blockage of the small fuel passageways in the carburettor resulting in fuel starvation. There was no evidence from the spark plug of fuel starvation and the
engine
did give 2.467 kW output indicating adequate fuelling.
I removed the main jet to check that it was the correct one. During removal the edges of the
screw
slot became damaged due to the difficult angle to access the slot without removing the carburettor. This area of the jet is immaterial in terms of the performance of the jet.
The jet should have a diameter of 0.7 mm according to the Hyundai Maintenance Manual, (Document 3). There were no markings on the jet so I measured the jet size. I selected a thin metal wire, in this case a needle which would just slide through the jet
. I them measured the diameter of the wire usi ng a 0 -25 mm micrometer. I measured the diameter as 0.75 mm, Figure 31. I retained the needle as exhibit HCS/4.
0.75 mm is oversize and would result in the carburettor being able to deliver about 15 % more fuel than a 0.7 mm jet. This would have an influence on the maximum power output of the
engine
and mixture strength at high loads but relatively little on the mixture strength at part loads. Any effect on mixture strength would be to make the mixture richer.
I checked the condition of the emulsion tube. All the holes were clear and clean.
I refitted the emulsion tube and main jet using a special tool which I made specifically for the purpose.
The
position
of the float in the float chamber is important as it controls the level of fuel and thereby the amount of fuel mixed with the air. A higher fuel level results in a richer mixture.
The specification for the float
position
is given in the maintenance manual (Document 3) as 12 mm. The manual however fails to state where the measurement should be taken. It is normal for the float to be horizontal when the fuel level is correct. I therefore connected the fuel line used on the Arniston to the carburettor, pumped fuel through the system and manually adjusted the float
position
until no fuel flowed from the inlet
valve
. The
position
of the float at which this occurred was horizontal. I measured the distance from the shoulder on the float to the
of the carburettor float chamber using a 150 mm
steel
rule. The distance was 12 mm. In my opinion the level of fuel in the carburettor was very likely correct.
I reassembled the carburettor float chamber bowl and confirmed that there were no fuel leaks.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
The carburettor is equipped with a mixture adjusting
screw
. For some markets it is sealed by the manufacturer but for the European market this is not the case. I examined the adjuster but could find no evidence of any changes having been made to its
position
, Figure 32. The Hyundai workshop manual (Document 3) contains no instructions for the adjust ment of the mixture strength.
4.09.05 Spark Plug
I attempted to remove the spark plug using the manufacturer's tool supplied with the generator set from
MAIB
. I was unable to remove the plug as it was too tight for the tool. I used a spark plug socket and swivel handle to remove the plug. Normally once the first tightness is released the plug can be removed with the fingers. On this occasion the plug would not unscrew by hand. This indicates that either the plug was over -tightened at some point and the threads damaged or the threads were crossed and therefore damaged. Having removed the plug it was visually apparent that the threads in the
were damaged. In my opinion the sealing washer on the plug was particularly flattened and the co rresponding marks on the mating face on the
cylinder head
indicate that over-tightening was the most likely scenario.
The plug installed was an NKG brand CR7HSA. According to the maintenance manual it should have been a Torch brand A7RTC as original equipment. I telephoned Adrian Griffiths of Genpower Ltd., the importer, on 22 January 2014, to enquire what plug was originally fitted. He advised me that Genpower removes the original Torch plug and fits the NKG alternative before the generator is shipped out for first use.
I measured the gap between the electrodes. It was between 0.63 mm and 0.71 mm, the specification being 0.6 mm to 0.7 mm. I visually examined the plug tip, Figure 33. It was in good condition and showed no signs of excessive
wear
and no damage. There was some build up of carbon deposits which would indicate
running
on a rich mixture. There were no oily deposits which might indicate that the
engine
was burning oil. There were no signs of overheating which would have indicated a weak mixture. I formed the opinion that there was no abnormal combustion occurring but that the mixture was rich.
When attempting to refit the spark plug it was apparent that the threads in the
cylinder head
were seriously damaged. Rather than force the plug back into place I retained the spark plug as exhibit HCS/3.
4.10 Exhaust System.
4.10.01 Introduction
I was asked to comment on the
construction
of the exhaust system on the Hyundai generator used on the Arniston. In my opinion it was unsuitable for a number of reasons which I shall describe in the following sections. However I shall first describe the characteristics which I should expect to see in a well designed exhaust system.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
4.10.02 Good Design
The first stage is to ensure that the engin e is positively and firmly secured and will not move in use. If it does it could cause breakage of the exhaust system even if well designed.
Sizing of pipework should be undertaken to avoid unnecessary back pressures which would compromise the performance of the
engine
. Such information is usually available from the manufacturer. In the case of the Hyundai 157 F
engine
used in this generator set information is provided in the type approval certificate.
In view of the temperatures encountered in an exhaust system the materials used for pipework and mufflers should be
steel
. Either mild
steel
or stainless
steel
may be used, the latter having better corrosion resistance and hence a longer useful working life. Where it is not necessary to separate two parts tubes should be welded together. Welds should be continuous and result in a gas tight join.
For parts which need to be separated a secure mechanical joint should be made. This could be by expanding one tube so that the other slides inside to effect a gas tight seal. It is normal practice to cut two slits on opposite sides of the larger sleeve to allow it to be clamped firmly onto the smaller diameter tube. Clamps should be strong and capable of squeezing the tubes together. An example is a `U' clam p which is often used on
car exhaust systems. If there is any risk of gas leakage then a suitable exhaust system sealant should be used. Pipe joiners comprising sleeves split at both ends for joining two tubes of the same diameter are readily available off the shelf.
Another way of joining two tubes is to weld a
flange
onto each and bolt the flanges together with a
steel
gasket or high temperature composite gasket as a seal. The use of flanged joints is more suited to larger installations.
As an
engine
vibrates there must be a flexible
coupling
between the
engine
and the main part of the exhaust system. This flexible
coupling
should be the first part of the exhaust system after the immediate parts of the
engine
, such as the
, catalysts, turbochargers etc. The reason for fitting the flexible
coupling
first is to minimise the movement on the
coupling
. If the
coupling
is further down the exhaust system the magnitude of vibrations of the
engine
is amplified by the distance betwee n the
engine
and the flexible
coupling
. This increased amplitude of vibration would result in failure of the exhaust system as the flexible
coupling
may well be working outside its designed range and other parts of the system would be un-necessarily stressed.
The choice of flexible
coupling
would depend on the application. Flexible stainless
steel
bellows type couplings fitted with flanges are often used on fixed installations such as larger generator sets, pumping sets and ships engines. Other designs include the use of two sockets with a woven metal
mesh
doughnut type gasket which allows relative movement as well as gas sealing.
A readily available type of flexible
coupling
comprises two stubs with a flexible stainless
steel
bellows protected with a braided stainless
steel
outer casing. These can be clamped or welded into the exhaust system. It can be a good idea to make a pair of matching flanges and weld one onto the inlet to the flexible
coupling
and the other onto the outlet from the
engine
. This allows the exhaust system and
engine
to be separated without having to move either significantly.
The weight of the whole exhaust system must be securely supported at several points. The method of support should include flexible connections such as rubber hangers or pads. This is to minimise
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
the transmission of vibrations, and hence noise, from the exhaust system to the surrounding structure. Various types of rubber mounting are readily available. The supports should be positioned to support the flexible
coupling
and close to bends to avoid the system twisting.
Mufflers are used to reduce the noise emitted at the open end of the
exhaust pipe
. These are readily available in a range of sizes for clamping or welding to other pipes.
A complete system would therefore comprise, in essence and starting from the
engine
, a flexible connector,
steel
tubes, with or without mufflers as needed, and a tail pipe to eject the exhaust gases to atmosphere. Flexible supports would be provided close to the flexible connector, close to the end of the system and close to any muffler, possibly one at either side. If the system is long additional flexible supports should be present to support the weight of the system and to prevent its twisting as a result of the use of bends.
If the system is in an
enclosed space
, following testing to confirm the absence of leaks, a heat resistant wrapping can be applied to minimise heat
to the immediate area of the
engine
.
The system should be tested under all anticipated operating systems from idle,
no load
up to maximum
speed
and load to confirm integrity.
As a matter of good practice the system should be visually inspected at regular intervals for signs of exhaust gas leakage. This is usually shown as black marking at, or adjacent to, the site of the leak. Appropriate steps should be taken to rectify any leak, especially if it is within the confines of a building, vehicle or vessel.
Carbon monoxide
or hydrocarbon gas detectors used manually can be useful when testing for leaks.
4.10.03 Initial Installation Considerations
In considering installing a generator set in any situation consideration should be given to the most appropriate location.
In the case of the Arniston in my opinion consideration should have been given to mounting the generator on
in the open air and connecting the generator electrical output to the electrical input provided on the vessel for connection when alongside.
When installing an
engine
attention should be paid to routine maintenance. All parts needing to be accessed for routine checks and servicing should be readily accessible. Access to a clean air supply should be arranged.
The removal of heat from the
engine
must also be considered, especially in the case of an air cooled
engine
. It is a rough rule of thumb that of the chemical energy going into an
engine
as fuel one third is used to produce useful work at the
, one third goes into the
and one third passes down the exhaust system. Therefore for this gener ator set, where the
engine
is rated at 3.95 kW (Document 1), there will be potentially 3.95 kW emitted into the immediate vicinity of the generator from the
cooling system
alone when it is
running
at full power. In addition there will be heat lost from the exhaust system which will add to the heating effect of the vicinity. (The generator set is rated at 2.6 kW continuous but because of losses within the system engines used in generator sets always have to have a significantly higher power output.)
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Overheating of the fuel system should be avoided as this can cause the formation of vapour bubbles in the fuel system which interfere, and can stop or prevent and
engine
from starting. Overheating of the intake air will also reduce its density and therefore th e power output of the
engine
. It may also affect the air fuel ratio. Fuel leakages in an
enclosed space
also present a risk of
or explosion.
4.10.04 Exhaust Fabricated for Generator Used on the Arniston
As far as I can determine from the reconstr uction and other information the generator set was not securely fixed to the structure of the vessel. Instead it appears that the location where it stood could be variable from time to time. It appears that it stayed in
position
, if it did, only by friction between the rubber mounting feet of the generator and the mat beneath it, and the friction between the mat and the structure of the vessel. This is unsatisfactory on a land installation and, in my opinion, worse in a marine application where the vessel can
and roll thereby not providing a stable base.
Copper tube was used as the main tube -work material. Copper is unsuitable as a material for constructing an exhaust system. Apart from the risk of chemical attack from exhaust gases, especially if the
engine
burns some oil, the material does not have suitable physical properties.
Joining copper tubes is difficult. Copper is soft, so tight clamping results in deformation of the copper and any subsequent relaxation releases the clamping pressure. Unlike
steel
, copper cannot be `welded' by fusing copper into joints. Therefore the joints will have to have a lower melting point material fused into them. This is, as was used in the
construction
of the exhaust system for the generator on the Arniston, solder, a mixture of lead and tin. The melting point, or at least softening point, is likely to be at or below the temperature of the exhaust gases, depending on how far away the joint is from the
engine
exhaust manifold
. In my opinion solder is com pletely unsuitable because of its relatively low melting point compared to the temperature of exhaust gases.
Copper has the property of work hardening. In other words as it is repeatedly flexed it becomes hard and brittle and breaks. I have seen this pr operty frequently used by `plumbers' and electricians to break tube and wire. Since the exhaust system will flex the copper will work harden and eventually fracture. Therefore, had the system not fallen apart by the melting of the solder in a soldered joint, in my opinion it is likely that in time the copper would have fatigued and fractured.
There was no flexible
coupling
installed as the first part of the exhaust system. In this case the full
engine
vibration and movement was transferred to the whole of the exhaust system. The movement was also magnified by the lengths of the tube used.
A muffler was fitted in the system. The muffler is relatively heavy and there was no means of supporting its weight. This is incorrect. The muffler was cantilevered out from the exhaust stub on the generator. This means that a large weight was being shaken up and down with a large amplitude. This motion will strain the system as a whole and
the copper tube. In the event it can be seen from the video taken during the reconstruction that a) the amplitude of vibration of the muffler was great, to the extend that the thermocouple broke off and b) the weight of the muffler caused a torsional force on a preceding joint which caused it to twist and come apart.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
A flexible connector was fitted between the downstream end of the muffler and the outlet through the hull. Whilst there is a case for putting a flexible
coupling
to minimise
on the seal between the
exhaust pipe
and the hull it is inappropriate to have this as the main flexible
coupling
in the exhaust system as the main part of the exhaust system is not isolated from the vibrations from the
engine
.
I note that the flexible
coupling
was of the spiral wound
steel
type. Sealing these at the ends on t o a tube is very difficult because of the spiral gas escape path naturally created by the forming of the tubing used. This problem can be overcome by welding or hydraulically crimping stub pipes onto the ends. However in this case it appears that the fab ricator of the exhaust system used a worm drive clip (sometimes called a Jubilee clip). Worm drive clips are suitable for clamping elastomeric tubing materials onto metal stubs, e.g. rubber coolant hoses onto metal radiator stubs. They are not suited, and are not effective, even when tightened as much as possible, for clamping metal tubes together. I note from the Test House report (Document 9), that the worm drive clips were not tightened. In my opinion the joints at each end of this flexible tube were bound to leak exhaust gases into the
engine
compartment
even without any catastrophic failure occurring.
The first copper fitting with was fitted to the stub on the generator's exhaust stub pipe was held by three self tapping screws. These would effecti vely secure the pipe from falling off but there appears to be no evidence of any exhaust sealant being used. Copper has a significantly higher coefficient of expansion so even if the connection were tight when cold it could tend to become loose as the temperature rose. It would have been wise to use a sealant as was done for the copper fitting at muffler inlet.
It would appear that it is unlikely that the fabricator of the exhaust system subjected the exhaust system to any effective testing. Testing s hould comprise
running
at
no load
to ensure basic integrity and to check for exhaust gas leaks. There are a number of simple tests to effect the latter. One is listening for hissing sounds. One is looking for signs of leakage. Splashing dilute washing up liquid on a suspect joint will reveal a leak if bubbles are formed. To test the system under pressure the outlet of the exhaust can be partially blocked whilst the
engine
is
running
. This provides a back pressure which reveals leaks which might not be observable at normal operating pressures.
Once satisfactory operation with
no load
has been confirmed, and any problems rectified, the system should be run at
,
full load
for at least an hour. Following this the system should be allowed to cool and the high load- high
speed
test should be repeated. This technique should reveal any problems caused by thermal expansion and contraction during use. In my opinion had the system been tested at
full load
, at least 2.5 kW electrical load, then the obs erved lack of integrity of the system would have become apparent. Since during the reconstruction the system disintegrated in less than five minutes with an electrical load of only 1 kW, it is likely that at an electrical load of 2.5 kW it would have fallen apart in rather less time.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
5.00 Summary of Conclusions
I have examined the evidence presented to me and formed the following conclusions.
5.01 Tampering
I formed the opinion that the
engine
had not been tampered with in a way which woul d affect its emissions of
carbon monoxide
. However since I did not fully investigate the maladjustment of the choke mechanism I cannot, without further investigation, state whether or not it had been tampered with.
5.02 Generator Set
Carbon Monoxide
Emissions
The choke mechanism was maladjusted on the generator set used on the Arniston. A similar maladjustment was present on the
MAIB
generator set indicating a possible manufacturing problem. The maladjustment would tend to make both engines run richer, i.e. produce more
carbon monoxide
.
In my opinion the
carbon monoxide
emissions from the generator set on the Arniston were higher than they should have been by virtue of the maladjustments found. However there was no other evidence to suggest that the
carbon monoxide
emissions were exceptionally high or atypical of what I should expect to observe from similar types of generator set.
The
engine
used in the Hyundai HY 3000SEi generator set would be expected to have
carbon monoxide
emissions of at least 3 to 4 % given the manufacturers specified air fuel ratio of 13.3 at
rated speed
, wide open throttle.
The
carbon monoxide
emissions results obtained by the VOSA test station on behalf of Cumbria Police should be treated with caution. I formed the conclus ion from those results that at an electrical load of 1 kW the
carbon monoxide
emissions were probably in the range 4 % to 8%, which is very high.
The
carbon monoxide
emissions results obtained by the VOSA test station on behalf of the
MAIB
are not quantitatively credible as the samples were almost certainly not taken correctly. All which can be concluded is that the
engine
was emitting much more than the 0.23 to 1.46 %
carbon monoxide
reported during those tests.
The carburettor main jet on the Arniston generator set was oversize. This would allow a greater power output from the
engine
but would not necessarily increase its
carbon monoxide
emissions at lower loads. This is most likely the condition of the
engine
from the manufacturer as there was no evidence of the jet's having been removed.
The air intake system was clean and free from blockages which might have increased
carbon monoxide
emissions
The condition of the spark plug confirmed that the
engine
ran with a rich air fuel ratio.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
5.03 Modifications to Arniston Generator Set
In my opinion installing an air cooled
petrol engine
in an
enclosed space
should only be undertaken as a last resort because of the technical problems relating to the safe
discharge
of exhaust fumes, effective cooling of the
engine
and
fire
hazards associated with fuel vaporisation in a hot
confined space
.
In my opinion the design and fabrication of the modified exhaust system on the Arniston were fundamentally flawed. The generator set was not fixed to the vessel allo
it to move. The vibrations from the generator set were not isolated from the main part of the exhaust system which would promote
fatigue
failure. The weight of the exhaust system was not properly supported and the materials used to make the exhaust system were unsuitable.
It is my further opinion that the exhaust system was highly likely to have leaked into the
engine
compartment
even without falling apart as it appears to have done. I would expect the system to have suffered
fatigue
failure had the soldered joint not become detached first.
In my opinion testing the installation at full electrical load on completion would have revealed that the system did not have adequate structural integrity.
It is my opinion the bypassing of the fuel cut off switch on the generator itself was unwise and not a safe practice as it means that in the event of a leak an operator has to move to a separate area of the vessel to isolate the fuel supply. This is especially important in a
confined space
where fuel vapour build up can reach flammable limits quite quickly.
There was evidence of lack of attention to detail regarding work carried out on the generator. For example the clip which should have secured the outlet side of the fuel filter was displaced and loose. Also one of the
screw
and bolt assemblies which retained the two halves of the generator set casing was missing and the connections to the battery were faulty.
Signed 10 February 2014
Dr ○○ of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Appendix 1
Qualifications, Experience, Appointments and Specialist Field of Writer of Report
I graduated from Imperial College in 1972 with a Bachelor of Science degree in Chemistry and as an Associate of the Royal College of Science. I gained the degree of Doctor of Philosophy f rom Imperial College in 1978 after carrying out research in mechanical engineering on lubrication. I also obtained a Diploma of Imperial College. Since 1986 I have been a member of the Institute of Petroleum now called the Energy Institute. I was elected a member of the Academy of Experts in 2000 and qualified as a mediator in 2003. I have written scientific papers on lubrication and exhaust emissions.
From 1977 until 1986 I worked for Ricardo Consulting Engineers, a research and development company specialising in
engine
design and development, being the company's Chief Chemist and managing variously the Chemistry and Exhaust Emissions Laboratories and the Lubricants Laboratory, latterly specialising in both lubricants and fuels testing. I became an i ndependent consultant in 1986 and work for a range of clients from the motor, petroleum and chemical industries, for
engine
and vehicle users as well as for local authorities, enforcement agencies and other organisations.
I have accepted instructions from the legal profession in a range of matters. I have acted in both civil and criminal cases for both claimant/pursuer/prosecution and respondent/defendant as well as a single joint expert. I have acted in a public enquiry and a class action in the USA. I have attended and given evidence in Court.
I have been active in the British Technical Council of the Motor and Petroleum Industries and in the Co-ordinating European Council for the Development of Performance Tests for Lubricants and
Engine
Fuels. I have sat on, been secretary of, and chairman of various national and European groups involved with exhaust emissions and with the specification and testing of fuels and lubricants. I am currently involved with the
technical panel relating to standards for petrol and diesel fuel. Between 2005 and 2007 I was an associate investigator with the Office of the Parliamentary and Health Service Ombudsman.
I specialise in the areas of tribology, fuels, lubricants and exhaust emissions particularly relating to reciprocating engines of all sorts, and vehicles. I also have an expertise in metrology,
engine
building,
engine
operation and other functional fluids such as coolants, transmission lubricants and hydraulic oils. My work covers a ll aspects ranging from specification through to the investigation of failures.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Appendix 2
Instructions from the
Marine Accident Investigation Branch
and Cumbria Police.
In my instructions I was asked to investigate the possible reasons for the high level of
carbon monoxide
emissions emitted by a particular Hyundai HY 3000SEi generator set. This generator had been installed and used on a motor boat, the Arniston, on which two people died as a result of
carbon monoxide
poisoning.
The
MAIB
instructed me to discover if the emissions were typical of generator sets of this type or if they were not what reasons there might be which would account for the high levels observed during a reconstruction and in tests carried out on 23 to 25 September 2013.
Cumbria Police instructed me to make an assessment of emissions from the subject generator and to compare them with data published by the manufacturer. They asked me to examine the internal mechanisms in the generator set to establish whether the internal me chanism had been modified in any way. If any modifications were to be found I was asked to give an opinion on what effect those changes might have had on the functionality of the generator and its
carbon monoxide
emissions. I was also asked to give and opinion as to whether or not those mechanisms had been altered or modified deliberately.
In carrying out my investigations I was asked to preserve, as far as possible, any forensic evidence of any interference with the mechanisms and to prevent contamination of any forensic opportunities. I was also asked to keep a photographic record of any changes, or not as the case may be.
Having carried out my investigations I was instructed to give opinions as to:
whether any mechanism was faulty and what has caused it to be, including the effects of general
wear
and tear and age,
the level of difference of
carbon monoxide
emissions, if any, between the subject generator and those stated as expected by the manufacturer, and
whether the siting of the generator in the condition it was in with the fuel and exhaust system set up employed in the boat, posed an obvious risk of death to the occupants, if I could comment on this.
I was asked to prepare a full report of my investigations.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Appendix 3
Documents Which Have Been Considered
Following is a
list
of the documents which I received from the
MAIB
, Cumbria Police, or other sources and have considered in forming my opinions and reaching my conclusions.
Document no
1 VCA type approval certificate for approval no e11*97/68SA*2004/26*0910*00, dated 16 October 2007, comprising 15 pages. 2
MAIB
Safety Bulletin 2/2013,
Carbon monoxide
poisoning on board the Bayliner 285 motor cruiser Arniston on Windermere, Cumbria resulting in two fatalities, undated, comprising 5 pages. 3 Hyundai Power Products Hyundai Generators HY 3000SI/HY 3000SEI Shop Manual, dated November 2011, comprising 71 pages. 4 Hyundai
Catalogue 2012-2013 HY 2000Si-HY 3000 Si, comprising 12 pages. 5 Printouts from VOSA emissions tests on
MAIB
generator set, dated 23 October 2013 comprising 1 page. 6 Printouts from VOSA emissions tests on Arniston generator set, dated 31 October 2013 comprising 3 pages. 7 Eltinge Chart, undated, comprising 1 page. 8 Arniston, Pre-purchase Report, dated 26 June 2008 comprising 14 pages. 9 Laboratory Report, Examination of a Hyundai Generator and Associated Exhaust System from the Recreational Craft Arniston, by The Test House, dated 10 July 2013, comprising 60 pages. 10 Images of Hyundai Generator and fuel system provided by Cumbria Police, undated, comprising 4 pages. 11 Witness Statement of , dated 7 November 2013, comprising 12 pages plus Appendices: 12 Appendix 1 comprising 7 pages. 13 Appendix 5 comprising 4 pages. 14
for
Leader Solder Wire 86032000, dated 5 March 2013 comprising 5 pages. 15 Reporting and investigation of gas-related incidents, IGEM, IGE/GL/8 Edition 2, comprising 57 pages.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Appendix 4
Figures
Following is s
list
of the figures in this Appendix.
Figure 1 Eltinge Chart showing the relationship between the composition of the exhaust emissions from a
petrol engine
and air fuel ratio.
Figure 2 Photograph showing the clip
the alternative fuel supply pipe to the inlet side of the generator set's
fuel pump
.
Figure 3 Photograph showing the
screw
and nut at the
bottom
front
position
holding the two halves of the casing to be missing.
Figure 4 The gauge on the fuel tank showing the tank to be between ¾ and full as received.
Figure 5 Arniston generator as received showing the battery
compartment
cover missing.
Figure 6 Arniston generator as received showing the exhaust safety cover missing.
Figure 7 Photograph showing the
engine
number.
Figure 8 Photograph showing the
engine
type number and the type approval number.
Figure 9 Image showing the clip on the inlet side of the fuel filter had been moved from its original
position
as shown by residual marks on the rubber fuel hose.
Figure 10 The clip which was supposed to retain the fuel hose on the outlet side of the fuel filter sitting loose around the pipe downstream of the stub on the fuel filter.
Figure 11 Oil level part way down the filler neck.
Figure 12 Arniston generator showing a) the wire terminal on the negative l ead had become disconnected but was attached to the battery, b) loose strands of wire at the positive wire terminal, c) corrosion present on the negative terminal and d) no insulating covers protecting the battery terminals.
Figure 13
MAIB
generator showing protective covers fitted to battery terminals.
Figure 14 Re-crimped wire terminal on the negative supply lead.
Figure 15 Refitted supply leads to the battery with exposed electrical parts wound with insulation tape.
Figure 16 Electrical box secured using a cable tie to the base on which the fuel tank would normally have sat.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 17 Marks on the plastic sleeve of start – run - stop switch possibly indicating the use of some other device to operate the generator.
Figure 18 Witness mark on the rod of the diaphragm assembly operating the choke plate.
Figure 19 Thermocouple body marked at 35 mm, at 60 mm and at 85 mm.
Figure 20 Material wiped from end of thermocouple following exhaust temperature tests on Arniston generator with econ switch on.
Figure 21 Image showing light clearly
passing
through the filter with no areas of blockage.
Figure 22 Choke actuation system showing that the end of the stranded wire stopped against the body of the diaphragm housing, upper image, which had left a mark on the housing, lower image.
Figure 23
Screw
holding air filter housing to carburettor. Lack of tool marks would indicate that the carburettor had not been removed.
Figure 24 Image showing choke plate lever in fully closed
.
Figure 26 Image showing choke plate lever not contacting stop to achieve fully open
position
.
Figure 27 Image showing choke plate in not fully open
position
caused by stranded wire fouling diaphragm body.
Figure 28 Image showing choke plate in fully open
position
.
Figure 29 Image showing checking the integrity of the diaphragm,
opening
depression
and leakage using a `Mityvac' vacuum
pump
.
Figure 30 Gritty material found at the
bottom
of the carburettor float chamber bowl.
Figure 31 Upper image shows needle
passing
through carburettor main jet. Lower image shows diameter of needle being measured using a 0-25 mm micrometer.
Figure 32 Mixture adjusting
screw
on carburettor.
Figure 33 Image of plug tip showing no evidence of oily deposits or overheating. The carbon deposits on the body indicate a rich mixture.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 1 Eltinge Chart showing the relationship between the composition of the exhaust emissions from a
petrol engine
and air fuel ratio.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 2 Photograph showing the clip
securing
the alternative fuel supply pipe to the inlet side of the generator set's
holding the two halves of the casing to be missing.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 4 The gauge on the fuel tank showing the tank to be between ¾ and full as received.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 5 Arniston generator as received showing the battery
compartment
cover missing.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 6 Arniston generator as received showing the exhaust safety cover missing.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 7 Photograph showing the
type number and the type approval number.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 9 Image showing the clip on the inlet side of the fuel filter had been moved from its original
position
as shown by residual marks on the rubber fuel hose.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 10 The clip which was supposed to retain the fuel hose on the outlet side of the fuel filter sitting loose around the pipe downstream of the stub on the fuel filter.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 11 Oil level part way down the filler neck.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 12 Arniston generator showing a) the wire terminal on the negative lead had become disconnected but was attached to the battery, b) loose strands of wire at the positive wire terminal, c) corrosion present on the negative terminal and d) no insulating covers protecting the battery terminals.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 13
MAIB
generator showing protective covers fitted to battery terminals.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 14 Re-crimped wire terminal on the negative supply lead.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 15 Refitted supply leads to the battery with exposed electrical parts wound with insulation tape.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 16 Electrical box secured using a cable tie to the base on which the fuel tank would normally have sat.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 17 Marks on the plastic sleeve of start – run - stop switch possibly indicating the use of some other device to operate the generator.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 18 Witness mark on the rod of the diaphragm assembly operating the choke plate.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 19 Thermocouple body marked at 35 mm, at 60 mm and at 85 mm.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 20 Material wiped from end of thermocouple following exhaust temperature tests on Arniston generator with econ switch on.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 21 Image showing light clearly
passing
through the filter with no areas of blockage.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 22 Choke actuation system showing that the end of the stranded wire stopped against the body of the diaphragm housing, upper image, which had left a mark on the housing, lower image.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 23
Screw
holding air filter housing to carburettor. Lack of tool marks would indicate that the carburettor had not been removed.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 24 Image showing choke plate lever in fully closed
through carburettor main jet. L ower image shows diameter of needle being measured using a 0-25 mm micrometer.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 32 Mixture adjusting
screw
on carburettor.
Report of: Specialist Field: Engines, Fuels, Lubricants, Exhaust Emissions
Figure 33 Image of plug tip showing no evidence of oily deposits or overheating. The carbon deposits on the body indicate a rich mixture.
Annex D
Carbon Monoxide
Safety on Boats -
and CoGDEM
CARBON MONOXIDE
SAFETY ON BOATS How to protect you, your
, your visitors and pets on your boat from the 'Silent Killer' -
Carbon Monoxide
Carbon monoxide
... what's the risk ? Whencarbon-based,appliance andenginefuels,suchasgas,
,coal,wood,paraffin,oil, petrolanddieseldon’tburn completely,COisproduced.
Eachyearboatersdieorare madeseriouslyillfrom carbonmonoxide(CO) poisoning. Boatsarebuilttokeepwater out,butthisalsomakes themgoodcontainersfor gasesandfumes. CO build-up in the
cabin
can occur with one or a mix of these factors: • Faulty,badlymaintainedor misusedappliances • Exhaustfumesfromaboat’s engineorgenerator • Escapedfluegasesfromsolid fuelstoves • Blockedventilationorshort supplyofair-fuelneeds oxygentoburnsafely Inrecentyears,solidfuelstoves andengineorgenerator exhaustgaseshavebeen responsibleformostdeathsof boatersfromCOpoisoning.
How the silent killer works! COcankillinminutes-be preparedtoactquicklyifyou thinkyouarebeing poisoned! COisahighlypoisonousgasthat weighsaboutthesameasair. Athighconcentrations,COcankill withoutwarning,sometimesin onlyminutes. Itcannotbeseen,smelt,tasted, orfelt,that’swhyit’sknownas thesilentkiller! WhenyoubreatheinCO,it replacestheoxygeninyour bloodstream,preventingessential suppliestoyourbodytissues, heart,brainandothervital organs. WherevictimssurvivesevereCO poisoning,theycanbeleftwith long-termbraindamagesuchas poorerconcentration,ormood swings,etc. Butevenbreathing-inlower levelsofCOoveralonger period,youcanstillsuffer seriouseffectssuchasmemory problemsanddifficulty concentrating. Some people will be affected much more quickly: • Pregnantwomenandunborn babies; • Babiesandyoungchildren • Olderpeople • Peoplewithrespiratory problemsorheartconditions For other reasons, some people may be at higher risk: • Thosewhohavebeendoing somethingactiveandare breathingmorerapidlyand deeplyandhaveagreater needforoxygen • Thosewhohavebeen drinkingheavily-becausethe symptomsmaybemasked IfCOisinyourcabinspace, everyoneisatrisk,nooneis immune!
CO poisoning can creep up on you – recognise the signs Ifyouareasleep,youmaynot noticeanysymptomsasthey develop. Even if you are awake Wehavelistedsomeofthe commonsymptoms,butnot everyonesufferingCOpoisoning willhaveallofthem. Common symptoms include: • Headacheandbadtemper • Feelingsickanddizzy • Feelingtiredandconfused • Stomachpainsandbeingsick Formoreinformationvisit theNHSwebsite http://www.nhs.uk/conditio ns/carbon-monoxidepoisoning The greater the amount of CO there is in air, or the longer you are breathing in CO, the worse your symptoms may get: • Drowsiness,lethargy,extreme tiredness,difficulty concentrating • Afeelingofgeneralweakness, difficultyinwalkingormoving • Lossofbalanceandsightand memoryproblems ...and with very high CO levels • Chestpains • Increasedheartrate • Difficultybreathingor breathlessness • Seizures • Collapse,unconsciousness anddeath
If you think you are suffering – ACT QUICKLY Fastactioncouldsaveyour life.Askyourself'Arepeople illonmyboat,butfeelOK ashore?' Ifyoususpectyouhavecarbon monoxidepoisoningortheCO alarmactivates,youneedtoact fast. Getallpeopleandpetsoutto freshairasquicklyasyoucanand stayoutinthefreshair. Ifyoucan,onyourwayout,turn offappliancesandengines… …alsoleavedoors,windowsand awningsopentoallowfreshairto flowthroughtheboat. Seek medical help and don’t delay!Tellthedoctorornurse thatyoumayhavesuffered carbonmonoxidepoisoning. Ifothercrewmembers,orpets, arefeelingillorhavethe symptoms,theyneedmedical helptoo. Anyone with severe symptoms needs to get to hospital as quickly as possible! Contact the emergency services straightaway. Severe CO poisoning needs immediate medical treatment COpoisoningcanonlybetested shortlyafterexposureasits tracesbegintodisappearas soonasyoustartbreathing clearair.
Know any danger signs on your boat Routinecheckingthatyour boat’sfuel-burning appliancesandenginesare freefromsignsofproblems andingoodconditionwill helpkeepyousafe. Anyofthefollowingcouldbe signsthatCOisfillingyourboat: • Staining,sootysmears,or discolourationonsurfaces aroundanapplianceoritsflue • Appliancesthataredifficultto light,keeplitorburnweakly • Burnerswithyellowororange or‘floppy’flamesthatthreaten togoout Ifthere'saCOproblemon yourboat-getaproperly qualifiedpersontofindand fixtheapplianceorengine beforeitisusedagain. • Anunfamiliarorburningsmell whenanLPGoroilappliance ison • Smellingorseeingsmoke escapingregularlyintothe cabinwhenrunningyour wood-burnerorcoalstove Fluegasesfromsolidfuel stovescanhaveupto100 timestheconcentrationsof COfoundingashob-burners withproblems. • Smellingengineexhaust fumesregularlyinsidethe cockpitorcabin
How to prevent CO on your boat COcanbeprevented.Takea fewsensiblestepstoreduce theriskdramatically. Onlybuyappliancesthatmeet thelateststandardsandare suitableforuseinboats. Haveappliancesproperlyinstalled andservicedroutinelyby competentfitters. Annualservicingofappliancesis recommendedwheretheboatis usedfrequentlyorforlonger periods. Ensureallrepairsuseproprietary components.Makenomistake, gashfixesorbodgejobsbring risks. Goodairsupplyinthecabinis vitaltorunningappliances. Therequiredventilationcanbe calculatedbyusingtheformula inCh.8oftheBSSEssential Guide Checkthecabinventsfor blockagesandbuild-upsof spiders’websanddebris. Openwindowsforextra ventilationwhencooking, especiallywhenusinglarge pansonLPGhobs. Checksolidfuelstovesfor cracks,missingcoverplates, warpeddoorsandpoor conditionropeseals. Followapplianceinstructionsburntherightfuelforyour stove,intherightway. Burning dampfuelorplastic rubbishcan causecloggingoftheflue. Whenremovinghotashesand embers,useametalashbucket withlidandkeepitoutsidein theopen.
Keep flue pipes and terminals in tip top condition! Crushingyourboat's chimneyterminalonabridge archcandamagemorethan yourpocket. Ensureallfluesorexhaustsvent ontheoutsideofawnings, covereddecksorcratches. Acleanfluepipekeptingood conditionwillhelpkeepagood drawandhelptheboatkeepfree fromtoxicfluegasses. Ensuresolidfuelstovechimneys aresweptatleastannually,or evenseveraltimesayear-the moreastoveisused,themore oftenthechimneyneeds cleaning. Checkallappliancefluepipes routinelyforrusting,pitting, blockages,looseormissing connections. Lookforsignsofleaks.Asooty smearatafluejointisabad sign. Checkthatventsandflue terminals,especiallyoncabin tops,arenotdamaged,blocked orrestrictedbystowed equipment,ropes,tarpaulinsor decorativeobjects. Fix all problems without delay and before the equipment is used again!
Beware of
. Neveruseanapplianceyou thinkisfaultyorunsafe. Neveruseanappliancethathas acrushedflueterminal. Neverrunportablegenerators inacabinorcoveredcockpit area,orclosetoanydoor, openingorventilatorthatopens intotheboat. Neverrunaboat’spetrol enginewiththeexhaustoutlet restrictedinanywayincluding whenthecraftmooredagainst ahigh-sidedobjectsuchasa wall,anotherboatorinsidea lock. Neverswimneartoboatswith theirenginesrunning–many boats’exhaustsareatlowlevel andcancreateatoxicatmosphereatwaterlevel.
CO alarms save lives Takethebeltandbraces approachbutnotethis,CO alarmsarenotasubstitute forthegoodinstallation, regularservicingandproper maintenanceoffuelburning appliancesandengines. Ifyouhaveanyfuelburning appliancesaboard,anengineor generator,fitasuitableaudible carbonmonoxidealarmforan addedre-assurance. ‘Black-spot’colour-changing indicatorcardsarenotgood enough.Youwon’thavean instantwarningofdangerousCO levelsandthere’snoalarmto wakeyouup. Fitalarmsthatmeetthe internationalstandardBSEN 50291-2;thesearebestsuited forboats.Alarmswithlife-long batteriesareavailable. LookoutfortheBSiKitemarkor LPCBhorseshoe'approval' symbolswhenbuyingalarmsfor additionalassurance. Ifindoubtaboutthechoiceof alarm,callthemanufacturer’s orsupplier’ssupportlinefor moreadvice. IfthereispotentialforCO poisoningonyourboat,itis bettertohaveanalarm,than not. Alarmsandwarningdevicesfor peoplewithhearinglossare available.
Where should you place your CO alarm? Allcabinswithafuelburning applianceshouldhaveaCOalarm fitted. Iffuelburningappliances, generatorsorenginesareused whilstpeoplesleep,allsleeping quarterswillneedtheirown alarms.Iftheboathasasingle multi-usecabin,onealarmisOK. Neverfitanalarmdirectly aboveasourceofheator steam. Forthebestprotection,followthe alarmmanufacturer’sinstallation instructionsasfarasthespace andnatureoftheboatallow. Butiftheplacementdirections aredifficulttomeetonyour boat,thesearethe‘best practice’points. Trytoplacethealarm: • Inlivingquartersbetween1m and3m(onplanview)from theappliance • Inlivingquartersfixalarms highuponawall,butatleast 150mmfromtheceilingand wheretheindicatorlightscan beseen • Insleepingquartershavethe alarminthe“breathingzone”, i.e.nearthebedhead • Beforefixing,testthatyou canhearanalarmfromany positionintheboat(orbuyan additionalalarm)
Living with your CO alarm Testthealarmswhenyoufirst boardtheboat.Testthealarm weeklywhentheboatisinuse. COalarmsdonotlastforeverand haveareplacementdatemarked onthem.Donotusethealarm beyondthatdateandifinany doubt,replaceitearlier. Whenworkingontheboatwith paints,solvents,degreasersor strongchemicals,coverorremove thealarmtemporarilytoprotect thesensor.Remembertoremove thecoverorreplacethealarmas soonastheairclearsandbefore youuseanyapplianceorengine. Considerremovingthealarm fromawinterisedboatbecause longperiodsofsub-zero temperaturesmayaffectits sensorandbattery. Alwaysre-installanyalarm afterwinterisation.Thentest thealarmbeforeany applianceorengineisused. Note these points: CO alarms only detect, they cannot prevent the dangerous build-up of
carbon monoxide
CO alarms may not fully safeguard individuals with specific medical conditions CO alarms will not detect fires, smoke or leakages of petrol or
LPG
fuel vapours A CO alarm can activate if it senses the explosive gas hydrogen; e.g. from the boat’s batteries gassing off when under charge, perhaps indicating a charging problem
If you are a tenant afloat Thelawprovidesseveral additionalprotectionsfortenantsincluding this: IfyourlandlordhasprovidedLPGappliances,he/shemustarrangefor anannualgassafetychecktobecarriedoutbyaGasSaferegistered engineer. IfyouareatenantinarentedboatwithconcernsaboutCO, raisetheissueswithyourlandlordor lettingagentwithout delay Ifyourconcernsarenotdealtwith,gotothelocalcouncil forhelpIfyoufeelunwellgetmedicalhelpstraightaway. Gotowww.
hse
.gov.uk/gas/domestic/faqtenant.htm formore informationfortenantsandthehealthandsafetyinprivatelyrented accommodationpagesonwww.gov.uk Further information on CO and boating FormoreinformationonCOandfiresafetyonboatsandroutine safetycheckitems-BoatSafetyScheme: www.boatsafetyscheme.org/stay-safe Foralarminformation-CouncilofGasDetectionandEnvironmental Monitoring(CoGDEM) cogdem.org.uk/CoGDEMCOsite/index.html ForgeneralCOadviceHealth&SafetyExecutive(
)GasSafety AdviceLine0800300363 www.
hse
.gov.uk/gas/domestic/co.htm GasSafeRegister–tofindregisteredgasfitters www.gassaferegister.co.uk BritishMarineFederation–tofindlocalboatyards www.britishmarine.co.uk
Charities concerned about CO The
Carbon Monoxide
and Gas Safety Society www.co-gassafety.co.uk CO-Awarenesswww.covictim.org Gas Safety Trust www.gas-safety-trust.org.uk Gas Safe Charity www.gassafecharity.org.uk CO-Angelswww.co-angels.co.uk Acknowledgements CoGDEMistheUKtradebodyfor companiesandexpertsinthe fieldofgasdetection.CoGDEM providesitsexpertisetoUK, Europeanandglobal standards-writingbodies,and providestechnicalguidanceand supporttoallCO awareness-raisingprojectsand organisations,includingtheHSE. Thisinformationissupportedby theCoGDEMmember companiesthatproduceCO alarmswww.cogdem.org.uk Publishedwiththegenerous supportoftheGasSafeCharity –helpingdirectlytomakegas safewhereit’smostneeded Theauthorsgratefullyacknowledgethe assistanceofthePublicHealthEnglandstaff especiallylinkedtothemedicalinformation. TheauthorsacknowledgetheHSEleaflet ‘GasAppliances-Getthemchecked,Keep themSafe’ref:INDG238(rev2)andthe DepartmentofHealthleaflet289814 ’Carbonmonoxide:Areyouatrisk?’as sourcedocuments. DesignbasedontheFireSafetyOnBoats leafletwithpermissionfromFireKills www.gov.uk/firekills TheauthorsaregratefultoSafelincsforits helpwiththeartworkwww.safelincs.co.uk, suppliersofsmokealarms,COalarmsand othersafetyequipment. PDFondemand&webrealisationbyPlan9 www.plan9.co.uk
CO threatens lives – stay safe, stay aware: Install fuel burning appliances properly Maintain appliances and engines routinely Use the equipment correctly Don’t allow
engine
fumes into the
cabin
space Deal with problems immediately Never bring a lit or cooling BBQ into any covered area Don’t allow bodged repairs and maintenance Install a CO alarm Test the alarm routinely Never remove the batteries Know the signs of CO poisoning and how to react CopyrightbelongstotheownersoftheBoatSafetySchemeand CoGDEMjointly. Thispublicationmaybefreelyreproduced,exceptforadvertising, endorsementorcommercialpurposes.Pleaseacknowledgethe sourceasBoatSafetyScheme&CoGDEM. PrintedwithvegetablebasedinksonrecycledpaperbyGreenshires CarbonMonoxideSafetyOnBoatsv3April2014
Annex E
MAIB
Safety Bulletin 2/2013
MAIB
SAFETY BULLETIN 2/2013
Carbon monoxide
poisoning on board the Bayliner 285 motor cruiser Arniston on Windermere, Cumbria resulting in two fatalities
Marine Accident Investigation Branch
Mountbatten House Grosvenor Square Southampton SO15 2JU
MAIB
SAFETY BULLETIN 2/2013 This document, containing safety lessons, has been produced for marine safety purposes only, on the basis of information available to date. The Merchant Shipping (Accident Reporting and Investigation) Regulations 2012 provide for the
to make recommendations at any time during the
of an investigation if, in his opinion, it is necessary or desirable to do so. The
Marine Accident Investigation Branch
is carrying out an investigation into the deaths of two persons on board the motor cruiser Arniston on 1 April 2013. The
MAIB
will publish a full report on completion of the investigation. Steve Clinch
Chief Inspector of Marine Accidents
NOTE This bulletin is not written with litigation in mind and, pursuant to Regulation 14(14) of the Merchant Shipping (Accident Reporting and Investigation) Regulations 2012, shall not be admissible in any judicial proceedings whose purpose, or one of whose purposes, is to apportion liability or blame. This bulletin is also available on our website: www.
maib
.gov.uk Press Enquiries: 020 7944 3387/6433; Out of hours: 020 7944 4292 Public Enquiries: 0300 330 3000
BACKGROUND A bank holiday weekend on board an 11 year old Bayliner 285 motor cruiser ended tragically when a mother and her 10 year old daughter died. Initial findings indicate the deceased were poisoned by
carbon monoxide
. INITIAL FINDINGS A “suitcase” type portable petrol-driven generator (Figure 1) had been installed in the motor cruiser’s
engine
bay to supply the boat with 240v power. The generator had been fitted with an improvised exhaust and silencer system which had become detached from both the generator and the outlet on the vessel’s side (Figures 2 and 3). As a result, the generator’s exhaust fumes filled the
engine
bay and spread through gaps in an internal
into the aft
cabin
where the mother and daughter were asleep. When the owner of the boat awoke in the boat’s forward
cabin
, he was suffering from
carbon monoxide
poisoning but was able to raise the alarm. The mother and daughter could not be revived. The boat’s
carbon monoxide
sensor system did not alarm because it was not connected to a power supply. Figure 1 Petrol generator
Figure 2 Silencer
Figure 3 Silencer Exhaust outlet
SAFETY ISSUES 1. Portable air-cooled petrol generators are readily available and inexpensive, but they are usually intended for use in the open air. The use or permanent installation of these engines on boats, particularly in
enclosed spaces
or below decks, increases the risk of
carbon monoxide
poisoning. 2. It is essential that
engine
exhaust systems are fitted and maintained to direct poisonous fumes outside the vessel clear of ventilation intakes and
spaces. Work on these systems should therefore only be undertaken by suitably qualified marine service engineers using approved parts and following the equipment manufacturer’s instructions for marine installations. 3.
Carbon monoxide
is a lethal gas, which has no smell, no taste, is colourless and is extremely difficult for human senses to detect. All boaters need to be vigilant and recognise the signs of
carbon monoxide
poisoning, which can include: headaches, dizziness, nausea, vomiting, tiredness, confusion, stomach pain and shortage of breath. 4.
Carbon monoxide
is a silent killer that is just as lethal afloat as it is ashore. The correct positioning and the regular testing of any
carbon monoxide
sensors, whether powered by a boat’s electrical supply or self-contained, is essential.
Carbon monoxide
sensor alarms that do not work correctly should be replaced. When selecting a
carbon monoxide
alarm preference should be given to those marked as meeting safety standard EN 50291-2:2010 which are intended for use in a
. Further advice on how to avoid
carbon monoxide
poisoning on boats and more detail about
carbon monoxide
alarms, produced by the
Boat Safety Scheme
(
BSS
) and the Council of Gas Detection and Environmental Monitoring (CoGDEM), can be found at: http://www.boatsafetyscheme.org/stay-safe/carbon-monoxide-(co) Issued May 2013
Annex F
MAIB
Safety Bulletin 1/2014
Extracts from The United Kingdom Merchant Shipping (Accident Reporting and Investigation) Regulations 2012 Regulation 5: “The sole objective of a
into an accident under these Regulations shall be the prevention of future accidents through the ascertainment of its causes and circumstances. It shall not be the purpose of such an investigation to determine liability nor, except so far as is necessary to achieve its objective, to apportion blame.” Regulation 16(1): “The
/ open-government-licence for details. All bulletins can be found on our website: www.
maib
.gov.uk For all enquiries: Email:
maib
@dft.gsi.gov.uk Tel: 023 8039 5500 Fax: 023 8023 2459 Press Enquiries: 020 7944 3231/3387 Out of hours: 020 7944 4292 Public Enquiries: 0300 330 3000 M A RINE A C C I DENT INVES TIG A T ION BR A NCH SAFETY BULLETIN SB1/2014 F ebruary 2014
Carbon monoxide
poisoning on board the scallop-
ESHCOL in Whitby, North Yorkshire on 15 January 2014 resulting in two fatalities
MAIB
SAFETY BULLETIN 1/2014 This document, containing safety lessons, has been produced for marine safety purposes only, on the basis of information available to date. The Merchant Shipping (Accident Reporting and Investigation) Regulations 2012 provide for the
Chief Inspector of Marine Accidents
to make recommendations at any time during the
course
of an investigation if, in his opinion, it is necessary or desirable to do so. The
Marine Accident Investigation Branch
is carrying out an investigation into the deaths of two persons on board the scallop-
dredger
Eshcol on 15 January 2014. The
MAIB
will publish a full report on completion of the investigation. Steve Clinch
Chief Inspector of Marine Accidents
NOTE This bulletin is not written with litigation in mind and, pursuant to Regulation 14(14) of the Merchant Shipping (Accident Reporting and Investigation) Regulations 2012, shall be inadmissible in any judicial proceedings whose purpose, or one of whose purposes, is to attribute or apportion liability or blame. This bulletin is also available on our website: www.
maib
.gov.uk Press Enquiries: 020 7944 4833/3387; Out of hours: 020 7944 4292 Public Enquiries: 0300 330 3000
Background An overnight break from
ended tragically when the
and a crewman sleeping on board the 9.95m scallop-
dredger
Eshcol died in their bunks. Initial findings indicate the men were poisoned by
carbon monoxide
. Initial Findings Before going to bed, the
skipper
(aged 26) and the crewman (aged 21) had lit the grill of a butane gas cooker fitted in the wheelhouse (Figure 1) in order to warm both the wheelhouse and the adjacent sleeping area. When they were not seen as expected the following morning, crewmen from
fishing
vessels tied up close by forced open the wheelhouse door. The gas grill was still lit (Figure 2) and the wheelhouse was full of fumes; the two men were dead in their bunks. Eshcol was not fitted with a
carbon monoxide
alarm. Figure 1 Figure 2
Safety Issues 1. Gas cookers are designed for cooking, not domestic heating.
Accommodation
areas need to be heated, especially during the winter months and, for this, appropriate, purpose built heaters are required. 2. Fossil fuel burning appliances, such as cookers, need to be checked and maintained to ensure they are in good condition. A yellow flame indicates poor combustion, resulting in an excess of
carbon monoxide
that, in a poorly ventilated space, can quickly build up to lethal levels. 3.
Carbon monoxide
is a lethal gas, which has no smell, no taste, is colourless and is extremely difficult for human senses to detect.
Crew
need to be vigilant and recognise the signs of
carbon monoxide
poisoning, which can include: headaches, dizziness, nausea, vomiting, tiredness, confusion, stomach pain and shortage of breath. 4.
Carbon monoxide
alarms are not expensive and should be fitted. When selecting a
carbon monoxide
alarm, preference should be given to those marked as meeting safety standard EN 50291-2:2010, which are intended for use in a
marine environment
. Further guidance for fishermen on the use of liquid petroleum gas (
LPG
) heaters and cookers can be found in Marine Guidance Notes 312 (F) and 413(F). More detailed advice on how to avoid
carbon monoxide
poisoning and on
carbon monoxide
alarms, can be found at: http://www.boatsafetyscheme.org/stay-safe/carbon-monoxide-(co) Issued February 2014
한국어 번역 · 모델 · 검수 전
부록 3 시편 M1의 필릿 및 젖음이 풀린 모세관 부위의 평균 분석값을 표시한 납-주석 평형 상태도 (평형 상태도 출처: h ttp://www.physicsforums.com)
알파상 +액체
고체 알파 + 베타상
부속서 B 사고 보고서 - 윈더미어. 코르기 기술 서비스(Corgi Technical Services Ltd)의 재현 결과 보고서 (부록 2 생략)
2.00 사건 배경과 쟁점 6 2.01 관련 당사자 6 2.01.1 영국 해양사고조사국 6 2.01.2 컴브리아 경찰청 6 2.02 가정된 사실 6 2.03 다루어야 할 쟁점 6
3.00 기술적 평가 8 3.01 개관 8 3.02 방법 8
4.00 조사 결과 10 4.01 배경 10 4.01.01 연소 10 4.01.02 람다 11 4.01.03 엘팅(Eltinge) 도표 11 4.02 형식 승인 11 4.03 MAIB VOSA 배출가스 시험 12 4.04 컴브리아 경찰청 VOSA 배출가스 시험 12 4.05 재현 14 4.06 발전기 세트의 개조 15 4.07 입수 당시 상태 15 4.08 배기 온도 시험 17 4.08.01 방법 17 4.08.02 부하 18 4.08.03 결과: MAIB 발전기 세트 18 4.08.04 결과: Arniston 발전기 세트 19 4.09 엔진 검사, Arniston 발전기 세트 21 4.09.01 서론 21 4.09.02 흡기 21 4.09.03 초크 기구 21 4.09.04 기화기 23 4.09.05 점화 플러그 24 4.10 배기 계통 24 4.10.01 서론 24 4.10.02 우수한 설계 25 4.10.03 초기 설치 시 고려 사항 26 4.10.04 Arniston호에서 사용된 발전기를 위해 제작된 배기관 27
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
5.00결론 요약 29 5.01 임의 조작 29 5.02 발전기 세트의 일산화탄소 배출 29 5.03 Arniston 발전기 세트의 개조 30
부록
1 작성자의 자격, 경력, 임명 사항 및 전문 분야로 구성된 이력서. 31
2 지시 사항 323 검토된 문서 334 그림 34
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
1.00 서론
1.01 형식 사항
본인의 이름은 ○○이며 의 사람이다. 본인은 연료, 윤활유 및 윤활, 배기가스 배출을 전문으로 하는 독립 컨설턴트로서 자영업에 종사한다.
본인은 영국 교통부 산하 영국 해양사고조사국(MAIB)과 컴브리아 경찰청으로부터 공동으로 의뢰를 받아 현대 HY 3000SEi 발전기 세트의 일산화탄소 배출을 조사하였다.
1.02 개요
2013년 4월 1일, 세 명이 윈더미어호(Lake Windermere)에서 Arniston호라는 모터보트에 탑승하여 밤을 보냈다. 탑승자 중 두 명이 일산화탄소 중독으로 사망하였다. Arniston호의 기관실에는 현대 HY3000SEi 가솔린 엔진 발전기 세트가 설치되어 있었다.
현대 HY3000SEi 발전기 세트는 플라스틱 하우징에 장착된 가솔린 엔진과 발전기로 구성된다. 이러한 발전기 세트는 독립형이며 반드시 옥외에서 사용하여야 한다. 이번 사례에서는 발전기 세트가 자체 내장 탱크가 아닌 별도의 공급원으로부터 연료를 받도록 개조되어 있었고, 배기 계통도 배기를 선체 밖으로 내보내도록 개조되어 있었다. 사고 당시 개조된 배기 계통은 분해되어 떨어져 나가는 방식으로 고장 났다. 이로 인해 일산화탄소를 포함한 배기가스가 선박의 기관실로 배출되었을 것이다.
컴브리아 경찰청은 컴브리아주 밀손프(Milnthorpe)에 있는 VOSA 시험소에서 이 발전기 세트의 일산화탄소 배출량을 측정하게 하였고, 그 결과 MAIB를 대신하여 구입하여 햄프셔주 보틀리(Botley)의 VOSA 시험소에서 시험한 다른 현대 HY3000SEi 발전기 세트에 비해 높은 것으로 나타났다.
MAIB와 컴브리아 경찰청은 모터보트에 탑승했던 사람들의 사망을 둘러싼 상황을 조사하고 있으며, 관측된 일산화탄소 배출 수준의 원인이 관심 사항이다.
1.03 지시 사항
본인은 MAIB와 컴브리아 경찰청 양쪽으로부터 지시를 받았다. 지시의 요지는 유사한데, 일산화탄소 중독으로 두 명이 사망한 Arniston호에 설치되어 사용된 현대 HY3000SEi 발전기 세트가 배출한 높은 수준의 일산화탄소 배출의 가능한 원인을 조사하라는 것이었다.
MAIB는 본인에게, 그 배출이 이 유형의 발전기 세트에서 전형적인 것인지, 그렇지 않다면 재현 시험과 컴브리아 경찰청을 대신하여 VOSA가 수행한 시험에서 관측된 높은 수준을 설명할 수 있는 원인이 무엇인지 밝히도록 지시하였다.
컴브리아 경찰청은 본인에게, 발전기 세트에서 측정된 일산화탄소 배출 수준의 원인을 조사하도록 지시하였다. 특히 본인은 관측된 농도가 작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 이 마모와 노후, 오작동, 제조상의 요인, 또는 우발적이든 아니든 간섭 중 무엇에 의하여 발생하였는지를 판단하도록 요청받았다.
또한 본인은 발전기가 당시의 상태 그대로, 모터보트에 사용된 연료 및 배기 계통 구성으로 설치된 것이 선박 탑승자에게 명백한 사망 위험을 초래하였는지에 대한 의견을 제시하도록 요청받았다. 아울러 배기 계통을 제작하는 데 사용된 설계, 구조 및 재료의 적합성에 대하여 논평하도록 요청받았다.
본인에게 내려진 지시의 자세한 내용은 부록 2에 있다.
1.04 이해관계 공개
본인은 MAIB와 컴브리아 경찰청의 의뢰를 받은 것 외에는 이 사건의 어느 당사자와도 개인적인 이해관계가 없다.
1.05 부록
부록 1에는 본인의 경력, 자격, 임명 사항 및 전문 분야에 관한 세부 내용이 있다.
부록 2에는 MAIB와 컴브리아 경찰청으로부터 받은 본인의 지시 사항이 있다.
부록 3에는 본인이 의뢰 변호사 또는 다른 출처로부터 받았고 의견을 형성하고 결론에 이르는 데 검토한 문서의 목록이 있다.
부록 4에는 보고서 본문에서 언급한 그림이 있다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
2.00 사건 배경과 쟁점
2.01 관련 당사자
2.01.1 영국 해양사고조사국
영국 해양사고조사국(MAIB)은 교통부 소속 기관이다. MAIB는 전 세계의 영국 선박에 또는 그 선박 내에서 발생하는 모든 유형의 해양사고와, 영국 영해 내의 기타 선박의 사고를 검토하고 조사한다.
2.01.2 컴브리아 경찰청
사건이 컴브리아 경찰청 관할 구역에 속하는 윈더미어호에서 발생하였으므로, 컴브리아 경찰청이 모터보트 탑승자들의 사망을 조사하고 있다.
2.02 가정된 사실
본 보고서에 담긴 결론에 이르면서 본인은 다음을 사실로 가정하였다.
0
발전기는 사고가 발생했을 때 약 1 kW의 전기 부하로 가동되고 있었다.
발전기가 부하 상태라고 기술된 VOSA 시험소의 시험에서 가해진 부하는 1 kW였다. VOSA 시험소에서 사용한 분석기는 기준 가스 혼합물로 교정되었으므로 분석기의 결과는 신뢰할 수 있다.
2.03 다루어야 할 쟁점
이 사건에서 다루어야 할 주요 기술적 쟁점은 네 가지이다.
첫째 쟁점은 Arniston호에 설치된 현대 HY3000SEi에서 측정된 일산화탄소 배출이 이례적으로 높았는지 여부이다.
둘째 쟁점은 관측된 일산화탄소 배출의 원인을 규명하는 것이다. 특히 관측된 배출 수준이 제조상의 요인, 정상적인 마모와 노후, 정비 부족, 또는 발전기 세트에 가해진 어떤 개조에 의해 발생하였는지 여부이다. 발전기 세트는 어느 경우이든 별도의 연료 탱크에서 연료를 받도록 개조되어 있었고 배기 계통도 배기가스를 선체 밖으로 배출하도록 연장되어 있었다. 그러나 본인은 일산화탄소 배출에 영향을 미쳤을 수 있는 다른 변경 사항이 있었다면 이를 밝히도록 요청받았다.
셋째로 다루어야 할 쟁점은 연료 및 배기 계통의 개조가 일산화탄소 배출에 미친 영향이다.
넷째 쟁점은 개조된 배기 계통의 적합성, 특히 그 제작에 사용된 설계와 재료이다. 본인은 배기 계통의 설계 작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 및 제작에 관한 우수 실무에 대한 정보를 제공하고, 그 실무를 Arniston호의 현대 HY3000SEi 발전기 세트의 배기 계통을 개조하는 데 사용된 실무와 비교하도록 요청받았다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
3.00 기술적 평가
3.01 개관
본인은 먼저 불꽃점화(가솔린) 엔진의 배기가스 배출과 관련된 용어와 관련 사항에 대한 간략한 배경을 제시한다. 이는 보고서 후반부의 기술적 논의를 이해하는 데 도움을 주기 위한 것이다.
첫째로 본인은 a) 현재의 지식 수준을 파악하고 b) Arniston호 발전기 세트에서 보고된 높은 일산화탄소 배출의 가능한 원인을 시사할 수 있는 증거를 발견하기 위하여, 본인이 보유한 이 사건 관련 기존 증거를 검토한다.
지금까지의 증거를 평가한 뒤, 본인은 개조된 배기 계통의 분해를 이해하는 데 추가로 도움이 될 수 있는 정보를 얻기 위해 엔진을 가동하여 다양한 부하에서 배기 온도를 측정한다.
조사의 세 번째 단계는 보고된 일산화탄소 배기 배출의 원인을 찾기 위해 발전기 세트를 단계적으로 분해하는 것이다. 배기가스 배출은 주로 흡기 계통과 연료 계통이 좌우하므로 본인은 이 부분에 조사를 집중한다. 그러나 발전기 세트의 다른 부분이 배기 배출에 영향을 미치고 있는 것으로 보이면 그 부분도 조사한다.
3.02 방법
본인은 현대 HY 3000SEi 발전기 세트 두 대를 접할 수 있었다. 하나는 2013년 4월 1일 사고에 관련된 Arniston호의 장치였고, 다른 하나는 MAIB가 비교 목적으로 구입한 신품이었다. 이를 통해 Arniston호 발전기 세트에 관한 본인의 관찰이 유사한 발전기 세트에서도 재현되는지, 아니면 본질적으로 Arniston호 발전기 세트에만 해당하는지 판단할 수 있다. Arniston호 발전기 세트의 어느 부분을 분해하는 데 우려가 있는 경우, 증거를 훼손할 위험을 최소화하기 위해 먼저 MAIB 발전기 세트에서 작업을 수행한다.
Arniston호 발전기 세트의 일산화탄소 배출은 2013년 9월 23일부터 25일까지 이루어진 재현 시험 중에, 그리고 컴브리아 경찰청의 지시에 따라 컴브리아주 밀손프의 VOSA 시험소에서 이미 측정된 바 있다. 본인은 시험을 반복하지 않았으나 그 신뢰성에 관한 의견을 형성하기 위해 시험 결과를 평가하였다.
마찬가지로 MAIB는 구입한 발전기 세트의 배기가스 배출을 햄프셔주 보틀리의 VOSA 시험소에서 측정하게 하였다. 이 역시 본인은 시험을 반복하지 않았으나 그 신뢰성에 관한 의견을 형성하기 위해 검토하였다.
Arniston호 발전기 세트의 배기 계통은 1 kW의 전기 부하가 걸린 상태에서 고장 났다. 그러나 이 발전기 세트의 정격은 교류 230볼트에서 2.6 kW이므로, 본인은 무부하와 약 0.5 kW 간격으로 2.5 kW까지의 부하에서 배기 온도 시험을 수행한다. MAIB 발전기 세트와 Arniston호 발전기 세트 모두에 대해 이코노미(econ) 스위치를 '켬'과 '끔' 위치에 놓고 이를 수행한다. 사고 당시와 재현 시험 중에 스위치는 '켬' 위치에 있었던 것으로 이해한다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 발전기 세트의 제어장치, 특히 엔진의 제어장치의 작동을 이해하기 위해 본인은 엔진을 가동하여 밸브 등의 작동을 관찰하며, 엔진을 분해할 때 그 가동 위치를 알 수 있도록 한다. 적절한 경우 그리고 비교용 기준 자료가 있는 경우 측정을 수행한다. 후자를 돕기 위해 본인은 수입업체인 밀퍼드 헤이븐(Milford Haven)의 Genpower Ltd로부터 2011년 11월자 현대 HY 3000SI/HY 3000SEi 정비 매뉴얼 사본을 입수하였다.
본인은 조사를 기록하고 결과를 보이기 위해 관련 부품의 사진을 촬영한다. 이 이미지는 부록 4에 있다.
본인은 의학 자격이 없으므로 일산화탄소가 인체에 미치는 생리적 영향에 대하여는 논평할 수 없다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
4.00 조사 결과
4.01 배경
4.01.01 연소
가솔린 엔진에서는 공기와 연료가 기화기에서 혼합되고, 혼합기가 엔진으로 들어가 점화 플러그에 의해 점화된다. 공기와 연료를 올바른 비율로 혼합하는 것이 기화기의 임무이다. 화학적으로 올바른 공기와 연료의 혼합은 이론 공연비(stoichiometric air fuel ratio)라고 한다. 가솔린의 경우 이를 (질량 기준) 14.7:1로 보는데, 연료의 정확한 조성에 따라 이 값에서 아주 약간 달라질 수 있다.
이상적으로는 이론 공연비에서 모든 연료가 완전히 연소하고 공기 중의 모든 산소가 소비된다. 그 결과 배기 생성물은 적어도 이론상으로는 이산화탄소와 물뿐이다. 실제로는 공기 중에서 온 질소산화물과 질소도 일부 있다. (이러한 조건에서 질소는 '연소'하지 않지만 연소 온도(2000+ C)에서 산소와 결합하여 질소산화물, 주로 일산화질소(NO)를 형성할 수 있다.)
실제로 연료가 연소할 때 연소의 기체 생성물은 이산화탄소, 불완전 연소로 생긴 일산화탄소와 탄화수소, 그리고 공기 중 질소와 산소의 반응으로 생긴 질소산화물의 혼합물이다. 질소와 경우에 따라 일부 산소도 있다.
이 사건에서 관심 대상인 배출물은 일산화탄소이므로 이후의 논의는 이 가스로 한정한다.
배기가스 중 일산화탄소의 농도는 공연비에 따라 달라진다. 비율이 14.7:1보다 크면 혼합기가 희박(lean)하다고 하며, 산소가 모두 가솔린에 사용되지 않았으므로 배기가스에서 산소가 발견된다. 양호한 연소에서는 일산화탄소 농도가 퍼센트가 아니라 ppm 수준으로 낮다.
공연비가 14.7:1보다 작으면 혼합기가 농후(rich)하다고 한다. 산소는 소량뿐이지만 일산화탄소 농도는 잠재적으로 높을 수 있다. 일산화탄소의 실제 농도는 혼합기가 얼마나 농후한지에 달려 있으며, 혼합기가 농후할수록 더 많은 일산화탄소가 생성된다.
1993년 이후 제조된 승용차용 가솔린 엔진에는 대기로 배출되는 배기가스를 줄이기 위한 배기 촉매가 장착되어 있다. 이러한 엔진은 연료 분사식이며 최근의 성층 급기 엔진을 제외하면 이론 공연비로 작동한다. 그러나 이 발전기 세트와 같은 산업용 엔진은 비용과, 낮은 배기가스 배출을 요구하지 않는 법규 때문에 기화기를 장착하고 촉매는 없다. 따라서 이러한 엔진은 본질적으로 일산화탄소를 많이 배출할 가능성이 있다.
희박한 공연비로 엔진을 운전하면 연료 효율이 개선된다. 그러나 이를테면 약 12.5:1에서 13:1 정도의 농후한 공연비로 운전하면 최대 출력이 나온다. 엔진이 갑작스러운 부하에 대응해야 할 때 성능 측면에서 후자가 바람직하다. 그러나 농후한 혼합기는 반드시 높은 일산화탄소 배출(및 높은 탄화수소 배출)을 낳는다.
가솔린 엔진을 냉간 상태에서 시동하려면 어떤 형태의 혼합기 농후화가 필요하다. 이를 흔히 초크(choke)라고 하는데, 기화기로 들어가는 흡기가 말 그대로 밸브에 의해 막히기 때문이다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 일부 산업용 엔진에서는 초크가 수동으로 조작되고 다른 엔진에서는 자동이다. 이 현대 HY 3000SEi 발전기 세트의 경우 초크는 진공 계통에 의해 자동으로 제어된다.
4.01.02람다
공연비를 기술할 때 람다(lambda)라는 값이 자주 사용된다. 이는 실제 공연비를 이론 공연비로 나눈 값으로 정의된다. 이론 공연비에서 람다는 1이다. 희박한 혼합기에서는 람다가 1보다 크고 농후한 혼합기에서는 1보다 작다.
4.01.03 엘팅(Eltinge) 도표
엘팅 도표(문서 7 및 그림 1)는 배기 시료의 일산화탄소, 이산화탄소, 산소 농도로부터 공연비를 구할 수 있도록 개발된 그래프이다. 엘팅 도표는 가솔린 엔진에서 배출되는 대로 측정한 미가공 배기가스에 대해서만 유효하다.
이 도표는 엔진 시험소에서 미가공 배기가스 배출 시험에서 얻은 결과를 검증하는 데 사용된다. 일산화탄소, 이산화탄소, 산소의 결과를 엘팅 도표에 표시하면 결과가 한 점에서 일치하여야 한다. 실제로는 실험 오차 때문에 결과가 작은 삼각형을 이룬다. 시험소는 형성되는 삼각형 크기의 한도를 허용 가능한 결과의 기준으로 정하며, 그 한도를 넘는 결과는 배기가스 분석기와 시료 채취 계통의 성능에 대한 조사를 촉발한다.
엘팅 도표는 가솔린 엔진 배기가스 배출 결과의 신뢰성을 검증하는 데 매우 유용할 뿐만 아니라, 다른 출처에서 공연비를 알고 있는 경우 엔진 배기가스의 일산화탄소 농도가 어느 정도일지를 가늠하는 데에도 쓸 수 있다.
4.02 형식 승인
EU에서는 엔진을 판매하기 전에 형식 승인을 받아야 하는 것이 법적 요건이다. 이는 엔진이 다양한 ECE 규정(EU 지침에 근거한 유럽 규정)의 해당 부분을 충족하여야 한다는 뜻이다. 충족하면 해당 국가 기관이 증명서를 발급하며, 영국의 경우 차량인증청(Vehicle Certification Agency, VCA)이 발급한다. 증명서에는 번호가 기재되며 이 번호는 엔진에 정해진 방식으로 표시되어야 한다. 이 현대 발전기 세트에 장착된 157F 엔진의 증명서는 문서 1에 있다. 증명서에는 증명서가 유효하고 엔진이 합법적으로 판매되기 위해 유지되어야 하는 핵심 설계 세부 사항이 들어 있다.
배기가스 배출 측정은 인증 과정의 일부이다. 배출물은 정해진 속도와 부하 조건에서 측정되고, 정해진 방식으로 '평균'되어 시험의 g/kW.hr 값으로 산출된다. 인증 값을 특정 운전 조건에서 특정 엔진의 농도로 환산하는 것은 불가능하다.
연료 유량과, 불꽃점화 엔진의 경우 공연비를 명시하여야 한다. 157F 엔진의 경우 공연비 값은 전부하, 정격 속도에서 13.3:1로 주어져 있다. 엘팅 도표에 따르면 이 공연비는 이 조건에서 배기가스의 일산화탄소 농도가 작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 3%를 약간 넘는 수준임을 나타낸다. 이 정보는 엔진이 농후한 혼합기로 설정되어 있음을 나타낸다. 이는 기술적으로 타당한데, 농후한 혼합기에서 최대 출력이 나오고 발전기는 연결된 전기 장비가 켜질 때 가해지는 갑작스러운 부하에 대응하도록 설정되어야 하기 때문이다. 그러나 엘팅 도표에서 볼 수 있듯이 농후한 혼합기는 일산화탄소(및 탄화수소)를 매우 많이 배출하게 할 수 있다.
형식 승인 증명서에 담긴 정보에 비추어, 본인은 이 엔진에서 상대적으로 높은 농도인 3% 이상의 일산화탄소가 나오리라 예상한다.
4.03 MAIB VOSA 배출가스 시험
MAIB는 자신의 발전기 세트의 배기가스 배출을 햄프셔주 보틀리의 VOSA 시험소에서 측정하게 하였다. 측정된 배출물은 일산화탄소, 이산화탄소, 탄화수소였다. 이 자료로부터 람다가 계산되었다. 이 계산은 측정 장비가 자동으로 수행하여 출력물에 표시했을 것이다. 출력물 사본은 문서 5에 있다.
본인은 MAIB로부터 발전기가 무부하와 명목상 1 kW 부하로 운전되었다고 이해한다.
본인은 출력물에 표시된 람다 값이 발전기에 부하가 걸렸을 때 2.334에서 3.293 사이, 무부하일 때 6.367에서 6.757 사이임을 확인하였다. 이 람다 값으로부터 본인은 공연비가 각각 34:1에서 48:1, 93:1에서 99:1이라고 계산하였다. 이 결과는 신빙성이 없다. 가솔린 엔진이 작동할 수 있는 가장 희박한 공연비는 약 20:1(람다 = 1.3)이다. 그 경우에도 희박 실화(lean misfire)가 발생하기 쉽고 갑자기 부하가 걸리면 시동이 꺼질 수 있다.
MAIB가 본인에게 제공한 발전기 세트를 검사했을 때, 본인은 배기관 토막의 바깥쪽 끝에 불꽃 방지기(spark arrestor)가 장착되어 있음을 확인하였다. 이는 철망으로 되어 있었다. 이 철망이 있으면 배기가스 분석기의 시료 채취 탐침이 배기관 안으로 들어갈 수 없다. 분석기는 가스 시료를 분석기로 빨아들이는 펌프를 갖추고 있다. 탐침을 배기관 안으로 충분한 깊이로 삽입하지 않으면 시료 탐침이 주변 공기를 빨아들이게 된다. 이는 배기가스 시료를 희석하여 산소 수준이 지나치게 높게 나타나게 하며, 그 결과 람다 값이 높게 나온다. 따라서 본인은 MAIB가 보틀리 VOSA 시험소에서 얻은 배기가스 배출 자료를 무시하였다.
이 결과로부터 끌어낼 수 있는 유일한 결론은 엔진이 이 시험들에서 기록된 것보다 높은 농도의 일산화탄소를 배출하고 있었을 가능성이 가장 크다는 것이다. 어느 시험 조건에서든 배기가스의 실제 일산화탄소 농도를 정량화하는 것은 불가능하다.
4.04 컴브리아 경찰청 VOSA 배출가스 시험
문서 6은 밀손프의 VOSA 시험소에서 Arniston호 발전기 세트에 대해 수행한 배기가스 배출 시험의 결과를 보여 준다. 본인은 시험이 부하를 가하지 않은 상태와 명목상 1 kW 부하 상태에서 수행되었다고 이해한다.
무부하, 부하, 그리고 무부하 조건 반복의 순서는 시험 기간 중 엔진 배출의 변동(drift)을 확인하는 우수한 실무를 보여 준다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 무부하 조건의 람다는 최초 시험에서 1.523에서 1.639 사이였고 반복 시험에서는 1.68이었다. 이 보고서 4.03항에서 언급하였듯이 가솔린 엔진은 람다가 1.3보다 큰 상태(공연비 20:1 초과)에서는 작동하지 않는다. 이러한 결과는 시료 채취 절차에 결함이 있었음을, 즉 시료 탐침이 적절한 배기가스 시료를 얻을 만큼 배기관 안으로 충분히 삽입되지 않았음을 본인에게 매우 강하게 보여 준다. 그 대신 분석기는 배기가스와 희석용 주변 공기의 혼합물을 측정하고 있었다.
MAIB 발전기의 경우 불꽃 방지기가 시료 탐침의 적절한 삽입을 막고 있었다. Arniston호 발전기의 배기 계통을 개조하는 과정에서 불꽃 방지기는 제거되어 있었다. 이 현대 엔진의 배기관 토막은 길이가 약 60 mm이다. 재현 시험 후 Arniston호 발전기 세트에 남아 있던 연장관을 포함하면 전체 끝 배관 길이는 85 mm였다. 배기 계통에서 나오는 배기가스의 맥동 때문에 배관의 맨 끝에는 배기가스와 공기의 혼합물이 들어 있게 되므로, 배기가스가 희석되는 구간을 피할 만큼 탐침을 충분히 삽입하는 것이 매우 중요하다. 여기에 더하여 VOSA 시험소는 대형 차량이 시험 과정에서 통과해 지나갈 수 있도록 보통 길고 큰 건물이다. 시험하는 차량에서 나오는 배기가스의 축적을 최소화하기 위해 양쪽 끝의 문이 열려 있는 경우가 많다. 따라서 건물에는 외풍이 있는 경우가 많다. 본인의 의견으로는 탐침이 배기가스의 대표 시료를 취하지 못하고 있었고 따라서 엔진의 실제 배출보다 훨씬 낮은 일산화탄소 수준을 나타내고 있었을 가능성이 거의 확실하다.
마지막 무부하 시험 결과가 처음 두 결과와 비슷했으므로, 시험자가 탐침 위치를 일관되게 유지했을 가능성이 낮기보다는 높다.
발전기 세트에 부하를 건 상태에서 수행한 세 번의 시험에서 기록된 람다 값은 0.965, 0.895, 0.836이었다. 시험이 진행된 6분 동안 혼합기가 점점 농후해졌거나 탐침 주변의 조건이 변하고 있었던 것으로 보인다. 예상되는 대로 탄화수소 배출도 같은 경향을 보인다. 본인은 공연비를 각각 14.2, 13.2, 12.3으로 계산하였으며, 이는 본인이 예상하는 수준과 대체로 같다.
시험에서 일산화탄소 농도는 7.12%에서 8.19% 사이로 나타난다. 이 결과는 12:1보다 농후한 공연비를 나타내는 매우 높은 값이다. 이 결과는 계산된 람다 값과 일치하지 않는다. 본인은 일산화탄소, 이산화탄소, 산소 배출을 엘팅 도표에 표시하려고 시도하였다. 결과가 표시 가능한 범위를 벗어났으며, 이는 결과의 신뢰성에 의문을 제기할 수밖에 없다. 람다를 계산하는 알고리즘이 분석 시스템 안에 '숨겨져' 있으므로, 측정된 다른 가스 중 하나의 농도가 계산된 람다 값을 왜곡하는 영향을 미쳤는지 여부에 관하여는 논평할 수 없다.
발전기를 부하 상태로 운전하면 발전기의 제어 계통에 의해 엔진 회전 속도가 높아진다. 그 결과 더 많은 가스가 배기 계통을 통과한다. 따라서 높은 부하에서는 주변 공기 희석의 영향이 더 작아 배출 결과가 더 신뢰할 만할 가능성이 있다.
종합적으로 본인의 의견은, 기록된 일산화탄소 배출 수준이 실제 배출을 반정량적으로 대표한다는 것이다. 본인의 의견으로는 이 시험 결과로부터 어느 시험 조건에서든 배기가스의 실제 일산화탄소 농도를 신뢰성 있게 정량화하는 것은 불가능하다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
4.05 재현
2013년 9월 23일부터 25일까지 에서 재현 시험이 수행되었다. 재현 시험의 일환으로 이 여러 위치에서 일산화탄소 농도를 측정하였다. 재현 시험의 대부분은 Arniston호 내부 각 부분 주변의 일산화탄소 농도를 측정하는 것이었다.
발전기 세트의 일산화탄소 배출은 2013년 9월 24일에 무부하 상태에서, 2013년 9월 25일에 부하 상태에서 측정되었다(문서 12). 무부하 상태의 네 가지 결과는 발전기 세트가 2.87%에서 4.54% 사이의 일산화탄소를 배출하였고 네 측정값 전체의 평균이 일산화탄소 3.93%였던 것으로 요약할 수 있다. 본인은 측정값 2번에서 4번의 결과가 3.89%에서 4.54% 범위였으며 그 평균이 일산화탄소 4.28%일 것임을 확인하였다.
본인은 시료 채취 방법을 살펴보기 위해 증거물 BS/344176에서 가져온 재현 시험 영상을 보았다. 본인은 한 경우에는 시료 탐침이 배기관 출구에 직각으로 들려 있었고 다른 경우에는 비스듬한 각도로 배기관 끝에 간신히 삽입되어 있었음을 확인하였다. 이 방법은 주변 공기를 빨아들일 위험이 있어 일산화탄소 농도가 허위로 낮게 나오게 된다. 관측된 측정값의 차이는 시료 채취 위치가 달랐기 때문일 수 있다.
2013년 9월 25일에는 부하 상태로 운전한 발전기 세트의 일산화탄소 배출을 측정하는 시험이 수행되었다. 4~5분의 시험 동안 얻은 세 결과는 이례적이고 놀라울 정도로 일관되어 모두 4.56%였다. 본인은 다시 증거물 BS/344177에서 가져온 재현 시험 영상을 검토하였다. 이 경우 시료 탐침은 배기관 끝 안으로 삽입되어, 배기가스의 압력 맥동이 시료 탐침 주위로 신선한 공기를 끌어들여 배기가스 농도를 희석하고 허위로 낮은 결과를 내기 쉬운 끝부분에서 떨어진 곳의 시료를 채취하였다.
따라서 엔진을 시험한 부하와 주변 조건에서 배기가스의 일산화탄소 농도는 4.56%였던 것으로 보인다. 이 수치를 이해하기 위해 설명하면, MOT 검사에는 공회전 시 일산화탄소 배출이 일정 한도 미만이어야 한다는 요건이 있다. 현재의 촉매 장착 승용차에서 이 한도는 차량 제조업체가 정한다. 촉매가 등장하기 전에는 제조업체가 충족할 한도를 제시할 수 있는 선택지가 있었다. 그러나 형식 승인에서 사용 중 일산화탄소 수준을 명시하도록 요구하지 않았던 구형 차량의 경우, 공회전 시 일산화탄소 농도의 기본 한도는 4.5%이다. 당시 엔진에는 기화기가 장착되어 있었으므로 이 현대 엔진과 유사한 기술이었으나, 기화기는 차량 엔진에 요구되는 양호한 운전성을 얻기 위해 대체로 약간 더 복잡하였다.
VOSA 결과를 재현 시험에서 얻은 결과와 비교하면 각각 7~8%와 4.5%로 상당한 불일치가 있다. VOSA가 사용한 분석 장비와 그 교정, 그리고 재현 시험 중에 사용된 일산화탄소 분석기에 대해 가솔린에서 유래한 배기가스 성분이 간섭을 일으켰을 가능성의 영향을 조사하지 않고서는, 본인은 이 차이에 대한 입증된 이유를 제시할 수 없다. 그러나 이 자료로부터 본인의 의견은 엔진이 농후하게 운전되고 있었으며 아마도 4~8%의 일산화탄소를 배출하고 있었으리라는 것이다. 이 수준은 극히 높다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
4.06 발전기 세트의 개조
수입업체가 공급한 발전기 세트에는 일체형 연료 탱크가 장착되어 있다. Arniston호에 설치된 발전기의 경우 일체형 연료 탱크는 제거되어 있었고, 입구 쪽 끝에 프라이밍 벌브와 바요넷 끝 커플링이 달린 별도의 연료 공급관이 그 자리에 장착되어 있었다. 이 새 관은 표준 연료 차단 스위치를 우회하여 발전기 세트의 연료 펌프 입구 쪽에 직접 연결되어 있었다. 그림 2에 보이듯이 금속 클립이 이를 펌프의 입구 토막에 고정하고 있었다. 연료관에는 3/16" Fuel hose, SAE J30 R6라는 표시가 있었으며, 이는 무연 가솔린에 사용하기에 적합함을 나타낸다.
연료 탱크를 떼어 내려면 외장 케이싱을 완전히 제거하여야 했을 것이다. 케이싱의 두 부분은 여섯 개의 나사/너트 조립체로 고정되어 있다. 앞쪽 아래 위치의 나사와 너트가 없었다(그림 3).
본인은 금속제 연료 탱크를 받았으며, 이는 Arniston호에서 기관실 바로 뒤쪽의 구획에 놓여 있었던 것으로 이해한다. 탱크에는 볼보의 선박 부문인 볼보 펜타(Volvo Penta)라는 이름이 있었다. 이 탱크는 육상에서 연료를 채우기 위해 떼어 낼 수 있는 전형적인 선박용 탱크이다. 연료관을 분리할 때 연료가 새지 않도록 바요넷형 출구가 있고 연료 게이지가 있다. 이 탱크에는 2행정 엔진에 사용할 때 2행정 오일을 채우기 위한 0.5 l 오일 탱크도 딸려 있었다. 현대 엔진은 2행정이 아니라 4행정 엔진이므로 이 탱크는 비어 있었다.
연료 탱크의 게이지는 탱크가 ¾와 가득 사이임을 보여 주었다(그림 4). Arniston호 발전기에 대한 본인의 시험에는 볼보 펜타 연료 탱크에 들어 있던 연료를 사용하였다.
본인의 의견으로는 안전상의 이유로 연료 차단 스위치를 우회하는 것은 현명하지 못하다. Arniston호의 설비에서는 연료 탱크에서 바요넷 커플링을 분리하여 엔진으로 가는 연료 흐름을 끊을 수 있었다. 그러나 엔진과 연료 탱크가 서로 다른 구획에 있었으므로, 기관실 안에서 연료를 차단하는 것은 불가능하였을 것이다.
원래 공급된 발전기 세트에는 소음 방출을 줄이기 위한 파란색 플라스틱 전체 케이싱이 장착되어 있다. 케이싱에는 나사로 고정된 점검 패널이 있다. 점검 패널은 배터리 구획용, 오일 점검과 공기 필터 청소 같은 일상 정비용, 그리고 점화 플러그 접근용으로 있다. 이에 더하여 엔진에 냉각 공기를 보내고 사용자가 뜨거운 배기 소음기에 닿지 않도록 보호하는 통풍형 안전 덮개가 있다. 배기관 토막의 끝에는 철망으로 된 불꽃 방지기가 씌워져 있다.
본인이 Arniston호 발전기 세트를 받았을 때 배터리 구획 덮개와 배기 안전 덮개가 없었다(각각 그림 5와 6).
4.07 입수 당시 상태
본인이 Arniston호에서 나온 발전기 세트를 받았을 때 4.06항에서 언급한 대로 패널 두 개가 없었다. 본인은 발전기 세트 전체의 사진을 촬영하였다. 장치 번호는 라벨에 HYK 311120002199로 기록되어 있었다.
원격 스위치는 '켬' 위치에 있었고 이코노미(econ) 스위치도 마찬가지였다. 키 시동을 가능하게 하는 키는 공급되지 않았다. 증거물 가방에 증거물 번호 JAM/9로 무선 리모컨이 제공되었다. 본인은 조사 중에 무선 원격 시동을 시험하거나 사용하지 않았다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 엔진을 가동하기 전에 본인은 엔진이 가동으로 인해 손상되지 않을 상태인지 확인하였다.
본인은 정비 덮개를 제거하고 엔진 번호 XG11121287, 엔진 형식 번호 157F, 형식 승인 번호 e11*97/68SA*2004/26*0910*00을 확인하였다(각각 그림 7과 8). 이는 본인에게 제공된 형식 승인 증명서(문서 1)에 인용된 번호와 같다.
본인은 모든 클립의 고정 상태를 육안으로 검사하였다. 연료 필터 입구 쪽 클립이 원래 위치에서 옮겨져 있음을 확인하였으며, 이는 고무 연료 호스에 남은 자국으로 알 수 있었다(그림 9). 연료 필터 출구 쪽 연료 호스를 고정하기로 되어 있던 클립은 연료 필터 토막보다 하류의 관 둘레에 헐겁게 걸쳐 있었다(그림 10). 이 위치에서는 클립이 관을 제자리에 잡아 주지 못하며, 고정은 오로지 연료 필터 토막에 대한 관의 마찰에만 의존하게 된다. 본인은 연결부를 구부려 보고 이 접합이 본인의 시험 목적에 한해서는 충분하다고 판단하였다. 시험 중에는 움직임이 있는지 자주 점검하였다.
주입구/유면 점검 목 아래 케이싱 바닥에 엔진 오일의 흔적은 없었다. 본인은 오일량을 점검하여 최대 수준(주입구 목의 맨 위)이 아니라 주입구 목의 중간쯤임을 확인하였다. 본인은 엔진이 시험 프로그램 동안 안전하게 가동하기에 분명히 충분한 오일이 있다고 판단하였다(그림 11). 이후의 결과에 영향을 줄 수 있으므로 다른 오일을 추가하거나 사용하고 싶지 않았다.
본인은 배터리를 점검하여 음극 리드선의 전선 단자가 분리되어 배터리에 얹혀 있음을 확인하였다. 또한 양극 전선 단자에 풀린 전선 가닥의 흔적이 있었고, 접합부는 어느 시점에 다시 압착된 것으로 보였으나 단자의 탭 두 쌍을 모두 사용하지는 않았는데 이는 사용해야 하는 방식과 다르다(그림 12).
양극과 음극 단자 모두 배터리 단자에 확실하게 조여져 있지 않았다. 음극 단자에는 부식이 있었다. 본인은 양호한 전기적 연결을 보장하기 위해 이를 청소하였다.
배터리 단자를 보호하는 절연 덮개가 없었다. 이러한 절연체의 부재는 배터리 단자의 단락을 막는 보호가 없어 불꽃이 생길 수 있으므로 잠재적 위험이다. 본인은 Arniston호 발전기를 MAIB 발전기와 비교하였다. 후자에는 보호 덮개가 장착되어 있었다(그림 13).
본인은 음극 공급 리드선에 전선 단자를 다시 압착하고(그림 14), 공급 리드선을 배터리에 다시 연결하였으며, 노출된 전기 부품을 절연 테이프로 감았다(그림 15).
이후 본인은 빨간색 양극 단자 덮개가 발전기 세트 케이싱 안에 헐겁게 있는 것을 발견하였다. 본인은 이를 증거물 HCS/2라고 표시한 증거물 가방에 넣었다.
본인은 배터리 전압을 점검하였으며 개회로에서 12.7 V였다. 본인은 배터리를 CTek MXS 5.0 배터리 충전기/시험기에 연결하였다. 이는 배터리에 엔진을 시동하기에 충분한 에너지가 있음을 보여 주었다. 나중에 전기적 문제나 배터리 충전으로 인한 가변 부하가 생기지 않도록 배터리를 완전 충전 용량까지 충전하였다.
배터리를 다시 장착하려 할 때 고정 스트랩의 일부가 없어서 배터리를 L자형 받침대에 제대로 고정할 수 없음을 확인하였다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 본인은 연료 탱크가 보통 놓이는 받침에 케이블 타이로 고정된 전기 박스가 있음을 확인하였다(그림 16). 본인은 이것이 무선 원격 시동용 무선 수신기/제어 장치라고 생각한다. 이는 보통 정면에서 볼 때 오른쪽의 제어 패널 뒷면과 연료 탱크 사이에 위치한다.
본인은 MAIB 발전기와 함께 제공된 키를 가져와 Arniston호 발전기를 키로 시동하고 정지하는 데 사용하였다. 운전/시동 키 스위치 내부의 플라스틱 고정구가 밀려나 키 조작을 막고 있음이 분명하였다. 플라스틱에는 발전기를 작동시키기 위해 다른 어떤 장치를 사용했을 수도 있음을 나타내는 자국이 있었다(그림 17). 본인은 리모컨이 아니라 키로 발전기를 제어할 수 있도록 슬리브를 다시 맞추었다. 재현 시험 영상으로 보면 정지와 시동은 무선 리모컨으로 이루어진 것으로 보인다.
본인은 기화기와 초크 장치에 누출이 있는지 육안으로 검사하였다. 누출은 없었다. 다만 다이어프램 조립체의 로드에 접촉 흔적(witness mark)이 있음을 확인하였다(그림 18). 이 로드는 연선(stranded wire)에 연결되어 초크 판을 작동시킨다. 접촉 흔적은 로드가 케이싱이나 다이어프램에 쓸리고 있었음을 나타낸다. 설정이 바뀌지 않도록 본인은 이 단계에서 이를 더 조사하지 않았다.
발전기 밑면을 점검할 때 은색 접착 테이프를 수거하였다. 본인은 이를 증거물 HCS/1로 보관하였다.
4.08 배기 온도 시험
4.08.01 방법
이 시험의 목적은 무부하와 명목상 1 kW를 포함한 다양한 전기 부하에서 Arniston호 발전기 세트의 배기가스 온도를 측정하는 것이다. 본인은 이코노미(econ) 스위치를 '켬' 위치에 놓은 시험과 '끔' 위치에 놓은 시험, 두 계열의 시험을 수행하였다. 이코노미 스위치는 발전기 세트가 더 낮은 속도로 운전할 수 있도록 하기 위한 것이다. 이는 소음뿐 아니라 연료 소비도 줄인다.
각 경우에 본인은 무부하로 시작하여 명목상 0.5 kW 단계로 최대 2.5 kW까지 부하를 올렸다. (발전기 세트의 정격 출력은 2.6 kW이다.) 이 순서는 배기 계통 온도가 단계적으로 상승하도록 하고 이전의 더 높은 부하 운전에서 남은 열을 피하게 한다. 같은 이유로 본인은 이코노미 스위치를 먼저 켜고 그다음 끄고 시험하였다. 이 시험이 끝나면 배기관 토막 안쪽 끝의 소음기 안쪽 면이 120 C 미만, 즉 무부하 시 배기 온도 미만이 될 때까지 엔진을 식혔다.
배기 온도는 위치에 매우 민감하다. 비교 가능한 결과를 위해서는 고정된 정해진 위치를 사용할 필요가 있다. 이를 위해 본인은 Robin RT 550 디지털 온도계에 연결된 강성 K형 열전대를 사용하였다. 본인은 배기관 토막의 길이를 측정하였으며 60 mm였다. 본인은 열전대 본체에 35 mm, 60 mm, 85 mm 위치를 표시하였다(그림 19). 35 mm 표시는 배기관 안으로 일부(35 mm) 들어간 반복 가능한 위치를 제공하였고, 60 mm 표시는 표준 MAIB 발전기 세트의 배기관 토막 안쪽 끝 위치를 제공하였다. 85 mm 표시는 재현 시험 중 Arniston호 발전기 세트에 장착되어 있던 구리 연장부를 고려한 배기관 토막 안쪽 끝을 제공하였다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 본인은 먼저 MAIB 발전기 세트를 사용하여, 이어서 Arniston호의 발전기 세트를 사용하여 시험을 수행하였다.
또한 Arniston호 발전기 세트에는 배기 머플러 바로 앞에 있는 팬의 뒷면에 반사 테이프를 붙였다. 이를 통해 켄트 무어(Kent Moore) 적외선 디지털 회전계로 엔진의 회전 속도를 측정할 수 있었다. MAIB 발전기에서는 팬 원판 자체에서 반사가 있어 때때로 회전 속도의 두 배를 표시하는 것으로 보였으므로, 합리적인 속도 값을 얻을 수 없었다.
4.08.02 부하
발전기 세트에 부하를 가하기 위해 본인은 명목 소비전력이 250 W, 400 W, 500 W, 1.5 kW인 히터를 구하였다. 본인은 각각을 교류 230볼트 전원에 연결하고 Kewtech KT71 PAT 시험기로 소비 전류를 측정하였다. 이로부터 실제 소비 전력을 계산하였다. 얻은 값은 각각 209 W, 370 W, 444 W, 1.444 kW였다. 본인은 히터를 선택적으로 연결하여 0.444 kW, 1.023 kW(444+370+209), 1.444 kW, 2.023 kW(1444+370+209), 2.467 kW(모든 부하를 함께 연결)의 부하를 만들었다. 본인은 발전기의 출력 전압을 확인하였으며 Arniston호 발전기는 225.6 V, MAIB 발전기는 233볼트였다. 230볼트에서 약간 벗어난 이 변동은 2% 미만의 오차를 가져온다. 가해진 부하의 정확도는 핵심 변수가 아니었으므로 본인은 이 오차를 받아들였다.
4.08.03 결과: MAIB 발전기 세트
MAIB 발전기 세트에 대해 얻은 결과는 표 1에 있다.
이코노미 스위치 위치 부하 kW 배기 계통 35 mm 깊이의 온도 C 배기 계통 60 mm 깊이의 온도 C 켬 0 150 측정하지 않음 켬 0.444 196 측정하지 않음 켬 1.023 272 측정하지 않음 켬 1.444 349 측정하지 않음 켬 2.023 435 - 442 측정하지 않음 켬 2.467 (*) (*)
끔 0 157 204 끔 0.444 143 226 - 236 끔 1.023 148 270 끔 1.444 305 - 318 354 - 358 끔 2.023 393 - 405 458 - 468 끔 2.467 412 - 418 459 - 470 표 1 MAIB 발전기의 배기 온도 시험 결과. 주변 온도 4 C. 비고: * 본문 참조 본인은 이 발전기 세트의 최초 시동이 어려움을 알게 되었다. 본인은 초크의 작동을 검사하기 위해 정비 덮개를 제거하였다. 본인은 엔진이 처음 점화되자마자 초크가 거의 바로 풀리고 있음을 확인하였다. 이로 인해 연속 운전에 필요한 연료 혼합기가 너무 희박해졌을 것이다. 따라서 본인은 작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 엔진을 시동하기 위해 초크를 손으로 닫힌 상태로 잡고 있었으며, 이후 시험 전에 무부하로 15분간 엔진을 예열하였다.
이코노미 스위치가 '켬' 위치에 있을 때 2 kW 부하를 가하자 과부하 경고등이 처음에는 켜졌다가 꺼졌고 엔진은 계속 가동되었다. 그러나 2.5 kW 부하를 가하자 과부하 경고등이 켜진 채로 유지되었다. 발전기는 계속 가동되었으나 전기 출력을 공급하지 않았다. 따라서 의미 있는 배기 온도 값을 얻을 수 없었다. 이코노미 스위치를 켠 상태에서는 예상대로 부하가 증가함에 따라 배기 온도가 상승하였다.
이 시험 중에 본인은 엔진 속도가 부하에 따라 일정하지 않고 제어 계통이 더 많은 부하를 공급하기 위해 엔진 속도를 높인다는 것을 확인하였다. 본인은 Arniston호의 발전기 세트를 가동할 때 이를 더 조사하였다.
이코노미 스위치를 '끔' 위치에 놓고 시험하였을 때 본인은 0.44 kW와 1 kW 부하에서 예상치 못하게 낮은 배기 온도를 확인하였다. 배기관을 가려 보는 조사를 통해 외부 기류가 측정 지점에서 배기가스를 냉각하고 있음을 알았다. 이를 극복하기 위해 본인은 온도 탐침을 60 mm, 즉 배기관 토막의 안쪽 끝까지 삽입한 측정을 한 계열 수행하였다. 온도 값은 더 안정되었고 예상되는 값과 부합하였다. 본인은 두 계열의 결과를 모두 기록하였다. 더 높은 부하에서는 35 mm 깊이에서 온도가 여전히 변동하지만, 배기 온도와 가스 유량이 더 높기 때문에 외부 기류의 영향을 덜 받게 됨을 볼 수 있다.
표면 열전대를 사용하여 본인은 2.5 kW 부하에서 배기 머플러 바깥 표면 중 배기관 토막에 인접한 부분과 배기관 토막 바깥 표면 중 머플러 표면에 인접한 부분의 온도를 측정하였다. 본인이 기록한 온도는 각각 257 C와 235 C였다.
시험이 끝났을 때 본인은 새로 뜨거워진 엔진의 강한 냄새를 맡았다. 본인은 이 엔진이 비교적 가벼운 부하 이외의 조건에서 가동된 것이 이번이 처음이었으리라고 추측한다. 그렇다면 엔진은 완전히 길들여지지(run in) 않은 것이며, 본인은 장치가 완전히 길들여질 때까지 이 엔진에 대한 추가 시험에서는 다른 배기 온도가 나오리라고 예상한다. 이는 이코노미 스위치를 켠 상태에서 엔진이 더 높은 부하에서 작동하기를 꺼리는 이유일 수도 있다.
본인이 기록한 배기가스 온도는, 예상대로, Arniston호에서 사용된 발전기의 배기 계통을 개조할 때 사용한 땜납의 용융 범위를 훨씬 웃돈다는 것을 확인한다.
4.08.04 결과: Arniston 발전기 세트
본인은 시험 전에 무부하로 15분간 엔진을 예열하였다. 엔진은 쉽게 시동되었으며, 초기 점화 후 엔진이 계속 가동될 수 있도록 초크가 천천히 풀렸다.
MAIB 발전기 세트를 시험할 때 엔진 속도가 변동하는 것을 확인하였으므로, 본인은 이번 시험 계열에서는 엔진 속도를 측정하였다.
이코노미 스위치를 '켬' 위치에 놓고 시험한 후, 본인은 열전대 끝에 탄소 침전물이 있어 농후한 운전을 나타냄을 확인하였다. 본인은 끝을 킴와이프 정밀 와이프(Kimwipe Precision Wipe)로 닦고 그 와이프를 증거물 HCS/2로 봉투에 담았다. 그림 20은 와이프에 묻은 침전물을 보여 준다. 시험을 시작하기 전에 열전대를 닦아 두었다.
표면 열전대를 사용하여 본인은 2.5 kW 부하에서 배기 머플러 바깥 표면 중 배기관 토막에 인접한 부분과, 배기관 토막에 붙은 구리관 연장부의 바깥 표면 중 머플러 표면에 인접한 부분의 온도를 측정하였다. 이코노미 스위치를 켠 상태에서 본인이 기록한 온도는 각각 163 C와 231 - 236 C였다.
본인은 이코노미 스위치를 끈 상태에서 2.5 kW 부하와 1 kW 부하로 시험을 반복하였다. 2.5 kW 부하에서 머플러 바깥 표면 중 배기관 토막에 인접한 부분의 온도는 113 C였고, 배기관 토막에 붙은 구리관 연장부의 바깥 표면 중 머플러 표면에 인접한 부분의 온도는 155 – 158 C였다. 1 kW 부하에서 머플러 바깥 표면 중 배기관 토막에 인접한 부분의 온도는 116 - 118 C였고, 배기관 토막에 붙은 구리관 연장부의 바깥 표면 중 머플러 표면에 인접한 부분의 온도는 138 – 141 C였다.
이 시험으로부터 이코노미 스위치가 엔진의 운전 속도를 낮추는 효과가 있음이 분명하나, 이는 약 1.5 kW까지의 부하에서만 해당한다. 스위치가 속도에 미치는 영향이 가장 큰 것은 무부하일 때이다.
결과는 또한 배기 온도가 냉각된 표면과 접촉하면 비교적 빠르게 낮아짐을 보여 준다. 이 시험 중 주변 온도는 5 C였음을 유의하여야 한다. 발전기가 밀폐된 공간에서 가동된 Arniston호에서는 주변 온도가 높아졌을 것이며, 배기 부품의 표면 온도도 이 시험에서 얻은 결과와 비교하여 높아졌을 것이다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 엔진이 가동되는 소리를 들었을 때 소리가 일정하지 않은 것으로 보였다. 가동 중에 본인은 스로틀의 움직임을 검사하기 위해 정비 덮개를 제거하였다. 현대 HY 3000SEi 발전기 세트에서는 스로틀 위치를 장치의 발전기 부분과 연동된 스테퍼 모터가 제어한다. 스로틀은 위치를 계속 바꾸고 있었다. 이는 부하와 엔진 속도의 변동으로 이어진다. 후자는 표 2에 나타나 있다. 스로틀 위치를 바꾸면 혼합기 농도에 영향을 준다. 일반적으로 반복된 변화는 평균적으로 더 농후한 혼합기를 낳는데, 엔진이 가속하려면 혼합기를 농후하게 하여야 하기 때문이다.
4.09 엔진 검사, Arniston 발전기 세트
4.09.01 서론
배기 온도 시험 후 본인은 엔진을 상당히 자세히 검사하였다. 이는 일부 부품을 제거하는 일이므로, 이 작업은 모든 엔진 가동 시험 후에 수행하기로 하였다. 혼합기 농도에 영향을 미치는 주요 구성 요소는 기화기와 흡기 계통이다. 점화 플러그의 상태는 연소에 관한 정보를 줄 수 있다.
4.09.02 흡기
막힌 공기 필터는 엔진으로 들어가는 공기 흐름을 제한하여 혼합기를 더 농후하게 만든다.
본인은 점검 덮개를 제거하고 필터 엘리먼트를 빼내어 공기 필터 엘리먼트를 제거하였다. 필터 엘리먼트는 깨끗해 보였고 막힌 흔적이 없었다. 본인은 필터를 깨끗한 흰 종이 위에서 두드려 보았다. 부분적으로 막힌 필터라면 예상되는 입자가 종이 위에 떨어지지 않았다. 또한 막힌 부분과 뚫린 부분이 섞여 있지 않은지 확인하기 위해 필터에 빛을 비추어 보았다. 막힌 흔적은 없었다. 그림 21은 필터를 통해 빛이 분명하게 통과하는 모습을 보여 준다.
4.09.03 초크 기구
가솔린 엔진이 냉간 상태에서 시동되려면 혼합기 농도를 높여야, 즉 농후하게 만들어야 한다. 그 이유는 연료의 휘발성과 흡기 계통의 설계와 관련이 있다.
일부 산업용 엔진에서는 초크가 수동으로 조작되지만, 현대 HY 3000SEi 발전기 세트에서는 초크가 자동이다. 본질적으로 기화기로 들어가는 공기량을 줄이는 초크 판은 연선을 통해 다이어프램 작동기에 연결되어 있다. 작동기는 한쪽 끝에 연선이 부착된 로드와 다른 쪽 끝의 다이어프램으로 구성된다. 다이어프램은 강철 하우징 안에 고정되어 있다. 로드의 반대쪽 다이어프램 면은 유연한 관과 체크 밸브를 거쳐 엔진 매니폴드에 연결되어 있다. 엔진의 피스톤이 오르내리면서 매니폴드에 감압이 생기고, 이것이 다이어프램을 움직여 초크 판을 움직이게 함으로써 엔진의 초크를 푼다. 이 특정한 구성에서 초크는 스프링에 의해 닫힌(즉 시동) 위치에 유지되고, 부압이 초크를 연다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 초크 계통의 조정을 위해 연선은 양쪽 끝에 하나씩 두 개의 나사 클램프로 고정되어 있다.
본인은 엔진을 가동할 때 로드에 접촉 흔적이 있어 다이어프램 하우징에 쓸리고 있음을 확인하였다(그림 18). 따라서 본인은 계통의 자유로운 움직임을 점검하였다. 자유로운 움직임에 제약은 없는 것으로 보였다.
시동 중에 초크가 풀릴 때 본인은 연선의 끝이 다이어프램 하우징 본체에 닿아 멈추고 있으며(그림 22), 이로 인해 하우징에 자국이 남아 있음을 확인하였다. 연결 계통이 자유롭게 움직이도록 두고 초크 레버 암의 스톱으로 초크 판의 움직임을 제어하는 것이 보통이다. 따라서 본인은 기구에 더 잘 접근하기 위해 외부 케이싱을 완전히 제거하여 이를 더 조사하였다.
본인은 초크 판을 잘 볼 수 있도록 공기 필터 덮개를 제거하였다. 본인은 공기 필터 하우징 자체가 이전에 제거되었다는 증거를 찾지 못하였다. 또한 에어 클리너와 기화기를 잇는 나사에 기화기가 제거된 적이 있음을 나타낼 자국도 없었다(그림 23).
기화기 본체에는 초크 레버 암의 스톱 역할을 하는 단일 기둥이 있어, 한쪽은 완전히 닫힌 위치를, 다른 쪽은 완전히 열린(가동) 위치를 정한다. 본인은 연선이 다이어프램 케이싱에 맞닿아 초크 판이 완전히 열리지 못하게 하고 있음을 확인하였다. 본인은 레버 암과 스톱 사이의 간극을 필러 게이지로 측정하였다. 간극은 1.5 mm였다. 그림 24부터 28은 이것이 초크 판의 위치에 미치는 영향과 스톱 기둥과 레버 암 사이 간극의 존재를 보여 준다.
초크가 완전히 열리지 않는다는 사실은 혼합기를 설계된 것보다 더 농후하게 만드는 효과가 있었을 것이다.
컴브리아 경찰청이 본인에게 내린 지시는 법의학적 기회를 보존하라는 것이었다. 따라서 본인은 나사에 의한 자국이 하나인지, 한쪽 끝 또는 다른 쪽 끝에 두 개인지 확인하기 위해 연선의 두 조정 나사를 풀지 않았다. 양쪽 끝에 자국이 각각 하나씩 있다면 본인은 조정이 제조업체를 떠났을 때의 상태 그대로라고 결론지을 것이다. 어느 한쪽 끝에 자국이 둘 이상 있다면 본인은 초크 기구가 제조 후에, 인도 전에 장치를 점검한 수입업체에 의해서든 그 이후 누군가에 의해서든 조정되었다고 결론지을 것이다.
본인은 MAIB가 제공한 발전기 세트의 같은 부분을 검사하였다. 접촉 흔적을 제외하면 초크가 완전히 열리지 않는 정확히 같은 특성을 보였다. 이 경우 본인은 스톱과 레버 암 사이의 간극을 2.6 mm로 측정하였다. 본인의 의견으로는 이 증거는 초크 작동 기구가 첫 사용자에게 도달하기 전에 조정이 맞지 않을 수 있음을 시사한다.
본인은 'Mityvac' 진공 펌프를 연결하여 다이어프램 자체의 건전성을 점검하였다. 초크는 20 kpa의 부압에서 열렸고 누설의 징후는 없었다(그림 29). 이 개방 압력은 본인의 의견으로는 적절하다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
4.09.04 기화기
기화기는 연료와 공기를 필요한 비율로 혼합한다. 이 혼합에 영향을 미치는 요인은 메인 제트, 에멀전 튜브, 플로트 챔버의 연료 높이이다. 본인은 이러한 변수들을 조사하였다.
본인은 기화기가 제거된 적이 있다는 증거를 찾지 못하였다. 개스킷 가장자리는 온전하였고 에어 클리너 하우징을 기화기에 고정하는 나사에도 공구 자국이 없었다. 기화기를 제거하려면 이 하우징을 제거하여야 했을 것이다.
본인은 연료를 배출하고 중앙 볼트를 풀어 플로트 챔버 보울을 제거하였다. 보울 안에는 모래 같은 물질의 흔적이 있었다(그림 30). 이는 이례적이지 않다. 기화기에 모래 알갱이가 들어가면 보통 기화기의 작은 연료 통로가 막혀 연료 부족이 발생한다. 점화 플러그에서 연료 부족의 증거는 없었고 엔진은 2.467 kW 출력을 냈으므로 연료 공급이 적절하였음을 나타낸다.
본인은 메인 제트가 올바른 것인지 확인하기 위해 이를 제거하였다. 제거하는 동안, 기화기를 떼어 내지 않고는 홈에 접근하는 각도가 어려워 나사 홈의 가장자리가 손상되었다. 제트의 이 부분은 제트의 성능과는 무관하다.
현대 정비 매뉴얼(문서 3)에 따르면 제트의 직경은 0.7 mm여야 한다. 제트에는 표시가 없어서 본인은 제트 크기를 측정하였다. 본인은 제트 구멍을 간신히 통과할 가는 금속 와이어, 이 경우에는 바늘을 골랐다. 그런 다음 0 -25 mm 마이크로미터로 와이어의 직경을 측정하였다. 본인은 직경을 0.75 mm로 측정하였다(그림 31). 본인은 이 바늘을 증거물 HCS/4로 보관하였다.
0.75mm는 치수가 크며, 기화기가 0.7 mm 제트보다 약 15% 더 많은 연료를 공급할 수 있게 한다. 이는 엔진의 최대 출력과 높은 부하에서의 혼합기 농도에는 영향을 미치지만 부분 부하에서의 혼합기 농도에는 비교적 거의 영향이 없다. 혼합기 농도에 미치는 영향이 있다면 혼합기를 더 농후하게 하는 것이다.
본인은 에멀전 튜브의 상태를 점검하였다. 모든 구멍이 막히지 않고 깨끗하였다.
본인은 이 목적을 위해 특별히 만든 전용 공구를 사용하여 에멀전 튜브와 메인 제트를 다시 장착하였다.
플로트 챔버 안의 플로트 위치는 연료 높이를 조절하고 그에 따라 공기와 혼합되는 연료의 양을 결정하므로 중요하다. 연료 높이가 높을수록 혼합기가 농후해진다.
플로트 위치의 규격은 정비 매뉴얼(문서 3)에 12 mm로 주어져 있다. 그러나 매뉴얼에는 측정을 어디에서 해야 하는지 명시되어 있지 않다. 연료 높이가 올바를 때 플로트가 수평인 것이 보통이다. 따라서 본인은 Arniston호에서 사용된 연료관을 기화기에 연결하고 계통에 연료를 펌핑한 다음, 입구 밸브에서 연료가 흐르지 않을 때까지 플로트 위치를 손으로 조정하였다. 이것이 일어난 플로트 위치는 수평이었다. 본인은 150 mm 강철 자로 플로트의 어깨부에서 기화기 플로트 챔버의 플랜지까지의 거리를 측정하였다. 거리는 12 mm였다. 본인의 의견으로는 기화기의 연료 높이는 매우 올바랐을 가능성이 크다.
본인은 기화기 플로트 챔버 보울을 다시 조립하고 연료 누설이 없음을 확인하였다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 기화기에는 혼합기 조정 나사가 갖추어져 있다. 일부 시장용으로는 제조업체가 이를 봉인하지만 유럽 시장용은 그렇지 않다. 본인은 조정기를 검사하였으나 그 위치가 변경되었다는 증거를 찾을 수 없었다(그림 32). 현대 정비 매뉴얼(문서 3)에는 혼합기 농도의 조정에 관한 지침이 없다.
4.09.05 점화 플러그
본인은 MAIB가 제공한 발전기 세트와 함께 공급된 제조업체의 공구로 점화 플러그를 제거하려고 시도하였다. 플러그가 공구로는 너무 꽉 조여 있어 제거할 수 없었다. 본인은 점화 플러그 소켓과 스위블 핸들을 사용하여 플러그를 제거하였다. 보통 처음의 조임이 풀리면 플러그는 손가락으로 뺄 수 있다. 이번에는 플러그가 손으로 풀리지 않았다. 이는 플러그가 어느 시점에 과도하게 조여져 나사산이 손상되었거나, 나사산이 엇물려(crossed) 손상되었음을 나타낸다. 플러그를 제거하고 보니 실린더 헤드의 나사산이 손상되어 있음이 육안으로 분명하였다. 본인의 의견으로는 플러그의 실링 와셔가 특히 납작하게 눌려 있었고 실린더 헤드의 접촉면에 대응하는 자국이 있어 과도한 조임이 가장 가능성이 큰 상황임을 나타낸다.
장착된 플러그는 NKG 상표의 CR7HSA였다. 정비 매뉴얼에 따르면 순정 장비로는 Torch 상표의 A7RTC였어야 한다. 본인은 2014년 1월 22일에 수입업체인 Genpower Ltd.의 Adrian Griffiths에게 전화하여 원래 어떤 플러그가 장착되어 있었는지 문의하였다. 그는 Genpower가 발전기를 첫 사용을 위해 출하하기 전에 원래의 Torch 플러그를 제거하고 NKG 대체품을 장착한다고 알려 주었다.
본인은 전극 사이의 간극을 측정하였다. 간극은 0.63 mm에서 0.71 mm 사이였으며 규격은 0.6 mm에서 0.7 mm이다. 본인은 플러그 끝을 육안으로 검사하였다(그림 33). 상태는 양호하였고 과도한 마모나 손상의 징후는 없었다. 농후한 혼합기로 가동되었음을 나타내는 탄소 침전물이 어느 정도 쌓여 있었다. 엔진이 오일을 연소시키고 있음을 나타낼 수 있는 기름기 있는 침전물은 없었다. 희박한 혼합기를 나타내는 과열의 징후도 없었다. 본인은 비정상적인 연소는 일어나지 않았으나 혼합기가 농후하였다는 의견을 형성하였다.
점화 플러그를 다시 장착하려 할 때 실린더 헤드의 나사산이 심하게 손상되어 있음이 분명하였다. 플러그를 억지로 제자리에 밀어 넣는 대신 본인은 점화 플러그를 증거물 HCS/3으로 보관하였다.
4.10 배기 계통
4.10.01 서론
본인은 Arniston호에서 사용된 현대 발전기의 배기 계통 구조에 대하여 논평하도록 요청받았다. 본인의 의견으로는 이는 다음 항에서 설명할 여러 이유로 부적합하였다. 그러나 본인은 먼저 잘 설계된 배기 계통에서 볼 수 있으리라 예상하는 특성을 설명한다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
4.10.02 우수한 설계
첫 단계는 엔진이 확실하고 단단하게 고정되어 사용 중에 움직이지 않도록 하는 것이다. 움직이면 잘 설계된 배기 계통이라도 파손을 일으킬 수 있다.
엔진의 성능을 저해할 불필요한 배압을 피하도록 배관의 치수를 정하여야 한다. 이러한 정보는 보통 제조업체에서 얻을 수 있다. 이 발전기 세트에 사용된 현대 157 F 엔진의 경우 정보는 형식 승인 증명서에 제공되어 있다.
배기 계통에서 마주치는 온도를 고려하면 배관과 머플러에 사용되는 재료는 강철이어야 한다. 연강이나 스테인리스강 중 어느 것이든 사용할 수 있으며, 후자는 내식성이 더 좋아 사용 수명이 더 길다. 두 부분을 분리할 필요가 없는 곳에서는 관을 서로 용접하여야 한다. 용접은 연속적이어야 하며 기밀 접합이 되어야 한다.
분리가 필요한 부분에는 견고한 기계적 접합을 하여야 한다. 이는 한쪽 관을 확관하여 다른 관이 그 안으로 미끄러져 들어가 기밀 밀봉을 이루도록 하는 방식일 수 있다. 큰 쪽 슬리브의 양쪽 반대편에 두 개의 슬릿을 내어 더 작은 직경의 관에 단단히 조일 수 있게 하는 것이 일반적인 관행이다. 클램프는 튼튼하고 관들을 서로 눌러 조일 수 있어야 한다. 한 예가 승용차 배기 계통에 흔히 사용되는 'U'자 클램프이다. 가스 누설의 위험이 조금이라도 있으면 적절한 배기 계통용 실런트를 사용하여야 한다. 같은 직경의 두 관을 잇기 위해 양쪽 끝이 갈라진 슬리브로 된 관 연결구는 시중에서 쉽게 구할 수 있다.
두 관을 잇는 또 다른 방법은 각각에 플랜지를 용접하고 강철 개스킷이나 고온용 복합 개스킷을 밀봉재로 삼아 플랜지를 볼트로 체결하는 것이다. 플랜지 접합은 더 큰 설비에 더 적합하다.
엔진은 진동하므로 엔진과 배기 계통의 주 부분 사이에는 유연 커플링이 있어야 한다. 이 유연 커플링은 배기 매니폴드, 촉매, 터보차저 등 엔진의 직접적인 부품 다음에 오는 배기 계통의 첫 부품이어야 한다. 유연 커플링을 가장 먼저 장착하는 이유는 커플링에서의 움직임을 최소화하기 위해서이다. 커플링이 배기 계통의 더 아래쪽에 있으면 엔진의 진동 크기가 엔진과 유연 커플링 사이의 거리만큼 증폭된다. 이렇게 증가한 진동 진폭은 유연 커플링이 설계 범위를 벗어나 작동할 수 있고 계통의 다른 부분에 불필요한 응력이 걸리게 되므로 배기 계통의 고장으로 이어질 것이다.
유연 커플링의 선택은 용도에 따라 다르다. 플랜지가 달린 유연성 스테인리스강 벨로스형 커플링은 대형 발전기 세트, 펌프 세트, 선박 엔진 같은 고정 설비에 자주 사용된다. 다른 설계로는 상대 움직임과 가스 밀봉을 모두 허용하는 직조 금속망 도넛형 개스킷이 있는 두 개의 소켓을 사용하는 것이 있다.
쉽게 구할 수 있는 유연 커플링 형식 중에는 편조 스테인리스강 외부 케이싱으로 보호되는 유연한 스테인리스강 벨로스가 달린 두 개의 토막으로 이루어진 것이 있다. 이는 배기 계통에 클램프로 고정하거나 용접할 수 있다. 맞는 한 쌍의 플랜지를 만들어 하나는 유연 커플링의 입구에, 다른 하나는 엔진의 출구에 용접하는 것이 좋은 방법일 수 있다. 이렇게 하면 어느 쪽도 크게 움직이지 않고 배기 계통과 엔진을 분리할 수 있다.
배기 계통 전체의 무게는 여러 지점에서 확실하게 지지되어야 한다. 지지 방법에는 고무 행거나 패드 같은 유연한 연결이 포함되어야 한다. 이는 배기 계통에서 주변 구조물로 진동, 그리고 따라서 소음이 전달되는 것을 작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 최소화하기 위한 것이다. 다양한 유형의 고무 마운트를 쉽게 구할 수 있다. 지지대는 유연 커플링을 지지하도록, 그리고 계통이 비틀리지 않도록 굽은 곳 가까이에 배치하여야 한다.
머플러는 배기관 열린 끝에서 나오는 소음을 줄이는 데 사용된다. 이는 다른 관에 클램프로 고정하거나 용접할 수 있도록 다양한 크기로 쉽게 구할 수 있다.
따라서 완전한 계통은 본질적으로 엔진에서부터 시작하여 유연 연결부, 필요에 따라 머플러가 있거나 없는 강관, 그리고 배기가스를 대기로 내보내는 배기 끝관으로 구성된다. 유연 지지대는 유연 연결부 가까이, 계통 끝 가까이, 그리고 어느 머플러든 가까이, 가능하면 양쪽에 하나씩 설치된다. 계통이 길면 계통의 무게를 지지하고 굽은 곳 때문에 계통이 비틀리지 않도록 추가 유연 지지대가 있어야 한다.
계통이 밀폐된 공간에 있으면 누설이 없음을 확인하는 시험 후에 엔진 주변 구역으로의 열 전달을 최소화하기 위해 내열 피복을 적용할 수 있다.
계통의 건전성을 확인하기 위해 공회전, 무부하부터 최대 속도와 부하까지 예상되는 모든 운전 조건에서 계통을 시험하여야 한다.
우수 실무의 문제로서 배기가스 누설의 징후가 있는지 계통을 정기적으로 육안 점검하여야 한다. 이는 보통 누설 지점이나 그 인접부에 검은 자국으로 나타난다. 특히 건물, 차량, 선박 안에서의 누설이라면 누설을 바로잡기 위한 적절한 조치를 취하여야 한다. 수동으로 사용하는 일산화탄소 또는 탄화수소 가스 감지기는 누설을 시험할 때 유용할 수 있다.
4.10.03 초기 설치 시 고려 사항
어떤 상황에서든 발전기 세트의 설치를 고려할 때는 가장 적절한 위치를 고려하여야 한다.
Arniston호의 경우 본인의 의견으로는 발전기를 갑판의 옥외에 설치하고, 발전기의 전기 출력을 접안 시 연결용으로 선박에 마련된 전기 입력부에 연결하는 것을 고려했어야 한다.
엔진을 설치할 때는 일상 정비에 주의를 기울여야 한다. 일상 점검과 정비를 위해 접근이 필요한 모든 부분은 쉽게 접근할 수 있어야 한다. 깨끗한 공기의 공급이 확보되도록 하여야 한다.
특히 공랭식 엔진의 경우 엔진의 열 제거도 고려하여야 한다. 대략적인 경험칙으로, 연료로 엔진에 들어가는 화학 에너지 중 3분의 1은 플라이휠에서 유용한 일을 하는 데 쓰이고, 3분의 1은 냉각 계통으로 가며, 3분의 1은 배기 계통을 통해 빠져나간다. 따라서 엔진 정격이 3.95 kW(문서 1)인 이 발전기 세트의 경우, 전출력으로 가동할 때 냉각 계통만으로도 잠재적으로 3.95 kW가 발전기 바로 주변으로 방출된다. 여기에 배기 계통에서 손실되는 열이 더해져 주변의 가열 효과를 키운다. (발전기 세트의 정격은 연속 2.6 kW이지만 계통 내부의 손실 때문에 발전기 세트에 사용되는 엔진은 항상 상당히 더 높은 출력을 내야 한다.)
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 연료 계통이 과열되면 연료 계통에 증기 기포가 생겨 엔진 시동을 방해하거나 중단시키거나 막을 수 있으므로 과열을 피하여야 한다. 흡기의 과열도 밀도를 낮추어 엔진 출력을 감소시킨다. 이는 공연비에도 영향을 줄 수 있다. 밀폐된 공간에서의 연료 누설은 화재나 폭발의 위험도 초래한다.
4.10.04 Arniston호에서 사용된 발전기를 위해 제작된 배기관
재현 시험과 기타 정보로부터 본인이 판단할 수 있는 한, 발전기 세트는 선박 구조에 확실하게 고정되어 있지 않았다. 그 대신 발전기가 놓인 위치는 때때로 달라질 수 있었던 것으로 보인다. 그 위치를 유지하였다면 그것은 발전기의 고무 마운트 발과 그 아래 매트 사이의 마찰, 그리고 매트와 선박 구조 사이의 마찰에 의해서였을 뿐인 것으로 보인다. 이는 육상 설비에서도 만족스럽지 못하며, 본인의 의견으로는 선박이 종동요와 횡동요를 하여 안정된 기반을 제공하지 못하는 선박 용도에서는 더 나쁘다.
주 배관 재료로 구리관이 사용되었다. 구리는 배기 계통을 구성하는 재료로 적합하지 않다. 배기가스에 의한 화학적 침식의 위험, 특히 엔진이 오일을 일부 연소시키는 경우의 위험은 차치하더라도, 이 재료는 적합한 물리적 특성을 갖고 있지 않다.
구리관을 잇는 것은 어렵다. 구리는 무르므로 단단히 조이면 구리가 변형되고 이후에 이완이 일어나면 조임 압력이 풀린다. 강철과 달리 구리는 접합부에 구리를 융합하는 방식으로 '용접'할 수 없다. 따라서 접합부에는 더 낮은 융점의 재료를 융합해 넣어야 한다. 이는 Arniston호 발전기의 배기 계통 제작에 사용된 것과 같이 납과 주석의 혼합물인 땜납이다. 융점, 또는 적어도 연화점은 접합부가 엔진 배기 매니폴드에서 얼마나 떨어져 있는지에 따라 배기가스 온도와 같거나 그보다 낮을 가능성이 크다. 본인의 의견으로는 땜납은 배기가스 온도에 비해 융점이 상대적으로 낮기 때문에 전혀 적합하지 않다.
구리에는 가공 경화(work hardening)라는 성질이 있다. 다시 말해 반복적으로 구부려지면 단단하고 부서지기 쉬워져 부러진다. 본인은 '배관공'과 전기 기술자가 관이나 전선을 부러뜨리기 위해 이 성질을 자주 이용하는 것을 본 적이 있다. 배기 계통은 휘어지므로 구리는 가공 경화되어 결국 파단될 것이다. 따라서 납땜 접합부의 땜납이 녹아 계통이 분해되지 않았더라도, 본인의 의견으로는 시간이 지나면 구리가 피로를 일으켜 파단되었을 가능성이 크다.
배기 계통의 첫 부분으로 설치된 유연 커플링은 없었다. 이 경우 엔진의 진동과 움직임 전체가 배기 계통 전체로 전달되었다. 사용된 관의 길이 때문에 움직임도 확대되었다.
계통에는 머플러가 장착되어 있었다. 머플러는 비교적 무겁고 그 무게를 지지할 수단이 없었다. 이는 옳지 않다. 머플러는 발전기의 배기관 토막에서 캔틸레버로 돌출되어 있었다. 이는 큰 무게가 큰 진폭으로 위아래로 흔들리고 있었다는 뜻이다. 이러한 운동은 계통 전체에 변형을 주고 구리관을 피로시킨다. 실제로 재현 시험 중에 촬영된 영상에서 a) 머플러의 진동 진폭이 커서 열전대가 부러져 나갔고 b) 머플러의 무게가 앞쪽 접합부에 비틀림 힘을 가하여 그 접합부가 비틀려 분리되었음을 볼 수 있다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 머플러의 하류 쪽 끝과 선체를 관통하는 출구 사이에는 유연 연결부가 장착되어 있었다. 배기관과 선체 사이의 밀봉에 가해지는 응력을 최소화하기 위해 유연 커플링을 두는 것이 타당한 면은 있으나, 배기 계통의 주 부분이 엔진의 진동으로부터 격리되지 않으므로 이를 배기 계통의 주 유연 커플링으로 삼는 것은 부적절하다.
본인은 유연 커플링이 나선 권선 강철(spiral wound steel) 형식이었음을 확인한다. 이러한 형식은 사용된 관을 성형할 때 자연히 생기는 나선형 가스 누출 경로 때문에 양 끝을 관에 밀봉하기가 매우 어렵다. 이 문제는 양 끝에 관 토막을 용접하거나 유압 압착하여 극복할 수 있다. 그러나 이 경우 배기 계통 제작자는 웜 드라이브 클립(때로는 주빌리 클립이라 한다)을 사용한 것으로 보인다. 웜 드라이브 클립은 탄성체 관 재료를 금속 토막에 고정하는 데, 예를 들어 고무 냉각수 호스를 금속 라디에이터 토막에 고정하는 데 적합하다. 이는 금속관끼리 고정하는 데에는 적합하지 않으며, 최대한 조이더라도 효과가 없다. 본인은 시험소 보고서(문서 9)에서 웜 드라이브 클립이 조여져 있지 않았음을 확인한다. 본인의 의견으로는 이 유연관 양 끝의 접합부는 파국적인 고장이 일어나지 않더라도 배기가스를 기관실로 누설하게 되어 있었다.
발전기의 배기관 토막에 장착된 첫 번째 구리 이음쇠는 자동 탭핑 나사(self tapping screw) 세 개로 고정되어 있었다. 이는 관이 떨어져 나가는 것을 효과적으로 막아 주었겠지만 배기 실런트가 사용되었다는 증거는 없는 것으로 보인다. 구리는 열팽창 계수가 상당히 높으므로 냉간 상태에서 접합이 단단했더라도 온도가 오르면 느슨해지기 쉽다. 머플러 입구의 구리 이음쇠에 했던 것처럼 실런트를 사용하는 것이 현명했을 것이다.
배기 계통 제작자가 배기 계통에 대해 효과적인 시험을 했을 가능성은 낮은 것으로 보인다. 시험은 기본적인 건전성을 확보하고 배기가스 누설을 확인하기 위해 무부하 운전을 포함하여야 한다. 후자를 확인하는 간단한 시험이 여러 가지 있다. 하나는 쉭쉭거리는 소리를 듣는 것이다. 하나는 누설의 징후를 살피는 것이다. 의심스러운 접합부에 묽은 주방 세제를 뿌려 기포가 생기면 누설이 드러난다. 계통을 가압하여 시험하려면 엔진을 가동하는 동안 배기 출구를 부분적으로 막을 수 있다. 이는 배압을 제공하여 정상 운전 압력에서는 관찰되지 않을 수 있는 누설을 드러낸다.
무부하에서 만족스러운 운전이 확인되고 어떤 문제든 바로잡은 후에는 계통을 전속도, 전부하로 최소 한 시간 동안 가동하여야 한다. 그다음 계통을 식히고 고부하-고속 시험을 반복하여야 한다. 이 기법은 사용 중 열팽창과 수축으로 인한 어떤 문제든 드러낼 것이다. 본인의 의견으로는 계통을 전부하, 즉 최소 2.5 kW 전기 부하로 시험했다면 관측된 계통의 건전성 결여가 분명해졌을 것이다. 재현 시험 중에 1 kW의 전기 부하만으로도 계통이 5분 이내에 분해되었으므로, 2.5 kW 전기 부하였다면 훨씬 짧은 시간에 분해되었을 가능성이 크다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
5.00 결론 요약
본인은 제시된 증거를 검토하고 다음과 같은 결론에 이르렀다.
5.01 임의 조작
본인은 엔진이 일산화탄소 배출에 영향을 미칠 방식으로 임의 조작되지 않았다는 의견을 형성하였다. 그러나 초크 기구의 조정 불량에 대하여 완전히 조사하지 않았으므로, 추가 조사 없이는 임의 조작되었는지 여부를 말할 수 없다.
5.02 발전기 세트의 일산화탄소 배출
Arniston호에서 사용된 발전기 세트의 초크 기구는 조정이 맞지 않았다. MAIB 발전기 세트에도 유사한 조정 불량이 있어 제조상의 문제 가능성을 나타낸다. 조정 불량은 두 엔진 모두 더 농후하게 가동되게, 즉 더 많은 일산화탄소를 생성하게 하는 경향이 있다.
본인의 의견으로는 Arniston호 발전기 세트의 일산화탄소 배출은 발견된 조정 불량으로 인해 있어야 할 수준보다 높았다. 그러나 일산화탄소 배출이 예외적으로 높거나 유사한 유형의 발전기 세트에서 관측되리라 예상하는 것과 다르다고 시사하는 다른 증거는 없었다.
현대 HY 3000SEi 발전기 세트에 사용된 엔진은 제조업체가 명시한 정격 속도, 스로틀 전개 시 공연비 13.3을 고려할 때 최소 3~4%의 일산화탄소 배출이 있을 것으로 예상된다.
컴브리아 경찰청을 대신하여 VOSA 시험소가 얻은 일산화탄소 배출 결과는 주의하여 다루어야 한다. 본인은 그 결과로부터 1 kW 전기 부하에서 일산화탄소 배출이 아마도 4%에서 8% 범위였으며 이는 매우 높다고 결론지었다.
MAIB를 대신하여 VOSA 시험소가 얻은 일산화탄소 배출 결과는 시료가 거의 확실히 올바르게 채취되지 않았으므로 정량적으로 신빙성이 없다. 결론지을 수 있는 것은 엔진이 그 시험에서 보고된 0.23~1.46%의 일산화탄소보다 훨씬 많이 배출하고 있었다는 것뿐이다.
Arniston호 발전기 세트의 기화기 메인 제트는 치수가 컸다. 이는 엔진이 더 큰 출력을 낼 수 있게 하나 낮은 부하에서의 일산화탄소 배출을 반드시 증가시키는 것은 아니다. 제트가 제거된 적이 있다는 증거가 없었으므로 이것은 제조업체에서 나온 엔진의 상태일 가능성이 가장 크다.
흡기 계통은 깨끗하였고 일산화탄소 배출을 증가시켰을 수 있는 막힘이 없었다.
점화 플러그의 상태는 엔진이 농후한 공연비로 가동되었음을 확인해 주었다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
5.03 Arniston 발전기 세트의 개조
본인의 의견으로는 배기가스의 안전한 배출, 엔진의 효과적인 냉각, 뜨거운 밀폐 공간에서의 연료 기화와 관련된 화재 위험에 관한 기술적 문제 때문에, 공랭식 가솔린 엔진을 밀폐된 공간에 설치하는 것은 최후의 수단으로만 하여야 한다.
본인의 의견으로는 Arniston호의 개조된 배기 계통의 설계와 제작은 근본적으로 결함이 있었다. 발전기 세트는 선박에 고정되어 있지 않아 움직일 수 있었다. 발전기 세트의 진동은 배기 계통의 주 부분과 격리되지 않아 피로 파괴를 촉진하였다. 배기 계통의 무게는 제대로 지지되지 않았고 배기 계통을 만드는 데 사용된 재료는 적합하지 않았다.
본인은 또한 배기 계통이 분해된 것으로 보이는 것과 같이 분해되지 않았더라도 기관실로 누설했을 가능성이 매우 높다는 의견이다. 납땜 접합부가 먼저 분리되지 않았더라면 계통이 피로 파괴를 겪었으리라 예상한다.
본인의 의견으로는 설치 완료 시 전 전기 부하로 설비를 시험했더라면 계통의 구조적 건전성이 충분하지 않음이 드러났을 것이다.
본인의 의견으로는 발전기 자체의 연료 차단 스위치를 우회한 것은 현명하지 못했으며 안전한 관행이 아니다. 누설이 발생한 경우 작업자가 연료 공급을 차단하기 위해 선박의 별도 구역으로 이동하여야 하기 때문이다. 이는 연료 증기가 축적되어 인화 한계에 매우 빠르게 이를 수 있는 밀폐된 공간에서 특히 중요하다.
발전기에 대해 수행된 작업에서 세부 사항에 대한 주의가 부족하였다는 증거가 있었다. 예를 들어 연료 필터 출구 쪽을 고정했어야 할 클립이 이탈하여 헐거웠다. 또한 발전기 세트 케이싱의 두 반쪽을 고정하는 나사와 볼트 조립체 하나가 없었고 배터리 연결부가 불량하였다.
2014년 2월 10일 서명 ○○ 박사 의 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
부록 1
보고서 작성자의 자격, 경력, 임명 사항 및 전문 분야 본인은 1972년 임페리얼 칼리지(Imperial College)에서 화학 이학사 학위를 받고 왕립과학대학(Royal College of Science) 준회원 자격으로 졸업하였다. 본인은 윤활에 관한 기계공학 연구를 수행한 후 1978년 임페리얼 칼리지에서 철학박사 학위를 받았다. 임페리얼 칼리지 수료증(Diploma)도 취득하였다. 1986년부터 본인은 현재 에너지연구소(Energy Institute)라고 불리는 석유연구소(Institute of Petroleum)의 회원이었다. 본인은 2000년에 전문가 아카데미(Academy of Experts) 회원으로 선출되었고 2003년에 조정인(mediator) 자격을 취득하였다. 본인은 윤활과 배기가스 배출에 관한 과학 논문을 집필하였다.
1977년부터 1986년까지 본인은 엔진 설계 및 개발을 전문으로 하는 연구개발 회사인 리카도 컨설팅 엔지니어스(Ricardo Consulting Engineers)에서 일하며 회사의 수석 화학자로서 화학 및 배기가스 배출 시험소와 윤활유 시험소를 여러 차례 관리하였고, 후반에는 윤활유와 연료 시험을 모두 전문으로 하였다. 본인은 1986년에 독립 컨설턴트가 되어 자동차, 석유, 화학 산업의 다양한 고객과 엔진 및 차량 사용자, 그리고 지방 당국, 집행 기관 및 기타 기관을 위해 일하고 있다.
본인은 여러 사안에서 법조계의 의뢰를 받아 왔다. 본인은 민사와 형사 사건에서 원고/소추측/검찰과 피고/피청구인 양쪽을 위해, 그리고 단독 공동 전문가로서 활동하였다. 본인은 공개 조사(public enquiry)와 미국의 집단 소송에서 활동한 바 있다. 본인은 법정에 출석하여 증언하였다.
본인은 영국 자동차·석유산업 기술위원회(British Technical Council of the Motor and Petroleum Industries)와 윤활유 및 엔진 연료 성능 시험 개발을 위한 유럽 조정 위원회(Co-ordinating European Council for the Development of Performance Tests for Lubricants and Engine Fuels)에서 활동하였다. 본인은 배기가스 배출과 연료 및 윤활유의 규격과 시험에 관여하는 여러 국가 및 유럽 단체에서 위원, 간사, 의장을 지냈다. 본인은 현재 가솔린과 디젤 연료 표준과 관련된 영국표준협회 기술 패널에 참여하고 있다. 2005년부터 2007년까지 본인은 의회 및 보건서비스 옴부즈만 사무국(Office of the Parliamentary and Health Service Ombudsman)의 객원 조사관이었다.
본인은 마찰학(tribology), 연료, 윤활유, 배기가스 배출, 특히 모든 종류의 왕복동 엔진과 차량에 관련된 분야를 전문으로 한다. 또한 계측학, 엔진 제작, 엔진 운전, 그리고 냉각수, 변속기 윤활유, 유압유 같은 기타 기능성 유체에 대한 전문성도 있다. 본인의 업무는 규격부터 고장 조사에 이르기까지 모든 측면을 아우른다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
부록 2
영국 해양사고조사국과 컴브리아 경찰청의 지시 사항 본인은 지시에서 특정 현대 HY 3000SEi 발전기 세트가 배출한 높은 수준의 일산화탄소 배출의 가능한 원인을 조사하도록 요청받았다. 이 발전기는 모터보트 Arniston호에 설치되어 사용되었으며, 이 보트에서 두 명이 일산화탄소 중독으로 사망하였다.
MAIB는 본인에게, 그 배출이 이 유형의 발전기 세트에서 전형적인 것인지, 그렇지 않다면 재현 시험과 2013년 9월 23일부터 25일까지 수행된 시험에서 관측된 높은 수준을 설명할 수 있는 원인이 무엇인지 밝히도록 지시하였다.
컴브리아 경찰청은 본인에게 대상 발전기의 배출을 평가하고 이를 제조업체가 공표한 자료와 비교하도록 지시하였다. 이들은 본인에게 발전기 세트의 내부 기구를 검사하여 내부 기구가 어떤 식으로든 개조되었는지 확인하도록 요청하였다. 개조가 발견되면 본인은 그러한 변경이 발전기의 기능과 일산화탄소 배출에 어떤 영향을 미쳤을 수 있는지에 대한 의견을 제시하도록 요청받았다. 또한 본인은 그러한 기구가 고의로 변경되거나 개조되었는지에 대한 의견을 제시하도록 요청받았다.
조사를 수행하면서 본인은 기구에 대한 어떠한 간섭이든 그에 관한 법의학적 증거를 가능한 한 보존하고 법의학적 기회의 오염을 방지하도록 요청받았다. 또한 본인은 변경 사항이 있든 없든 이에 대한 사진 기록을 유지하도록 요청받았다.
조사를 수행한 후 본인은 다음에 관한 의견을 제시하도록 지시받았다.
일반적인 마모와 노후의 영향을 포함하여, 어떤 기구가 불량한지와 그 원인이 무엇인지, 대상 발전기와 제조업체가 예상치로 명시한 것 사이에 일산화탄소 배출의 차이가 있다면 그 정도, 그리고 발전기가 당시의 상태 그대로, 보트에 사용된 연료 및 배기 계통 구성으로 설치된 것이 탑승자에게 명백한 사망 위험을 초래하였는지 여부(이에 관해 논평할 수 있다면).
본인은 조사에 관한 전체 보고서를 작성하도록 요청받았다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
부록 3
검토된 문서 다음은 본인이 MAIB, 컴브리아 경찰청 또는 다른 출처로부터 받았고 의견을 형성하고 결론에 이르는 데 검토한 문서의 목록이다.
문서 번호
1 승인 번호 e11*97/68SA*2004/26*0910*00에 대한 VCA 형식 승인 증명서, 2007년 10월 16일자, 15쪽. 2 MAIB 안전 회보 2/2013, 컴브리아주 윈더미어에서 Bayliner 285 모터 크루저 Arniston호의 일산화탄소 중독으로 두 명 사망, 일자 없음, 5쪽. 3 현대 파워 프로덕츠(Hyundai Power Products) 현대 발전기 HY 3000SI/HY 3000SEI 정비 매뉴얼, 2011년 11월자, 71쪽. 4 현대 예비 부품 카탈로그 2012-2013 HY 2000Si-HY 3000 Si, 12쪽. 5 MAIB 발전기 세트에 대한 VOSA 배출가스 시험 출력물, 2013년 10월 23일자, 1쪽. 6 Arniston호 발전기 세트에 대한 VOSA 배출가스 시험 출력물, 2013년 10월 31일자, 3쪽. 7 엘팅 도표, 일자 없음, 1쪽. 8 Arniston호 구매 전 보고서, 2008년 6월 26일자, 14쪽. 9 시험소 보고서(The Test House), 레저 선박 Arniston호의 현대 발전기 및 관련 배기 계통 검사, 2013년 7월 10일자, 60쪽. 10 컴브리아 경찰청이 제공한 현대 발전기 및 연료 계통 이미지, 일자 없음, 4쪽. 11 의 증인 진술서, 2013년 11월 7일자, 12쪽 및 부록: 12 부록 1, 7쪽. 13 부록 5, 4쪽. 14 Boss Leader 땜납 와이어 86032000의 물질안전보건자료(MSDS), 2013년 3월 5일자, 5쪽. 15 가스 관련 사고의 보고 및 조사, IGEM, IGE/GL/8 제2판, 57쪽.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출
부록 4
그림 다음은 이 부록에 있는 그림의 목록이다.
그림 1 가솔린 엔진 배기가스 배출 조성과 공연비 사이의 관계를 보여 주는 엘팅 도표.
그림 2 대체 연료 공급관을 발전기 세트 연료 펌프의 입구 쪽에 고정하는 클립을 보여 주는 사진.
그림 3 케이싱의 두 반쪽을 고정하는 앞쪽 아래 위치의 나사와 너트가 없음을 보여 주는 사진.
그림 4 입수 당시 탱크가 ¾와 가득 사이임을 보여 주는 연료 탱크의 게이지.
그림 5 입수 당시의 Arniston호 발전기, 배터리 구획 덮개가 없음을 보여 줌.
그림 6 입수 당시의 Arniston호 발전기, 배기 안전 덮개가 없음을 보여 줌.
그림 7 엔진 번호를 보여 주는 사진.
그림 8 엔진 형식 번호와 형식 승인 번호를 보여 주는 사진.
그림 9 연료 필터 입구 쪽 클립이 고무 연료 호스에 남은 자국으로 보아 원래 위치에서 옮겨졌음을 보여 주는 이미지.
그림 10 연료 필터 출구 쪽 연료 호스를 고정하기로 되어 있던 클립이 연료 필터 토막보다 하류의 관 둘레에 헐겁게 걸쳐 있는 모습.
그림 11 주입구 목의 중간쯤에 있는 오일량.
그림 12 Arniston호 발전기, a) 음극 리드선의 전선 단자가 분리되어 배터리에 얹혀 있음, b) 양극 전선 단자에 풀린 전선 가닥, c) 음극 단자의 부식, d) 배터리 단자를 보호하는 절연 덮개 없음을 보여 줌.
그림 13 배터리 단자에 보호 덮개가 장착된 MAIB 발전기.
그림 14 음극 공급 리드선에 다시 압착한 전선 단자.
그림 15 노출된 전기 부품을 절연 테이프로 감아 배터리에 다시 연결한 공급 리드선.
그림 16 연료 탱크가 보통 놓이는 받침에 케이블 타이로 고정된 전기 박스.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 그림 17 발전기를 작동시키기 위해 다른 어떤 장치를 사용했을 수도 있음을 나타내는 시동 - 운전 - 정지 스위치 플라스틱 슬리브의 자국.
그림 18 초크 판을 작동시키는 다이어프램 조립체 로드의 접촉 흔적.
그림 19 35 mm, 60 mm, 85 mm 위치가 표시된 열전대 본체.
그림 20 이코노미 스위치를 켠 상태에서 Arniston호 발전기의 배기 온도 시험 후 열전대 끝에서 닦아 낸 물질.
그림 21 막힌 부분 없이 필터를 통해 빛이 분명하게 통과하는 모습을 보여 주는 이미지.
그림 22 연선의 끝이 다이어프램 하우징 본체에 닿아 멈추고 있음(위 이미지)과 그로 인해 하우징에 남은 자국(아래 이미지)을 보여 주는 초크 작동 계통.
그림 23 공기 필터 하우징을 기화기에 고정하는 나사. 공구 자국이 없음은 기화기가 제거된 적이 없음을 나타낸다.
그림 24 초크 판 레버가 스톱에 맞닿은 완전히 닫힌 위치에 있는 모습을 보여 주는 이미지.
그림 25 초크 판이 완전히 닫힌 위치에 있는 모습을 보여 주는 이미지.
그림 26 완전히 열린 위치에 이르기 위한 스톱에 초크 판 레버가 닿지 않는 모습을 보여 주는 이미지.
그림 27 연선이 다이어프램 본체에 걸려 초크 판이 완전히 열리지 않은 위치에 있는 모습을 보여 주는 이미지.
그림 28 초크 판이 완전히 열린 위치에 있는 모습을 보여 주는 이미지.
그림 29 'Mityvac' 진공 펌프를 사용하여 다이어프램의 건전성, 개방 부압, 누설을 점검하는 모습을 보여 주는 이미지.
그림 30 기화기 플로트 챔버 보울 바닥에서 발견된 모래 같은 물질.
그림 31 위 이미지는 기화기 메인 제트를 통과하는 바늘을 보여 준다. 아래 이미지는 0-25 mm 마이크로미터로 바늘의 직경을 측정하는 모습을 보여 준다.
그림 32 기화기의 혼합기 조정 나사.
그림 33 기름기 있는 침전물이나 과열의 증거가 없음을 보여 주는 플러그 끝의 이미지. 본체의 탄소 침전물은 농후한 혼합기를 나타낸다.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 그림 1 가솔린 엔진 배기가스 배출 조성과 공연비 사이의 관계를 보여 주는 엘팅 도표.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 그림 2 대체 연료 공급관을 발전기 세트 연료 펌프의 입구 쪽에 고정하는 클립을 보여 주는 사진.
작성자: 전문 분야: 엔진, 연료, 윤활유, 배기가스 배출 그림 3 케이싱의 두 반쪽을 고정하는 앞쪽 아래 위치의 나사와 너트가 없음을 보여 주는 사진.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 4 접수 당시 연료탱크 게이지가 탱크 양이 3/4 와 만재 사이임을 보여 주고 있다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 5 접수 당시의 Arniston호 발전기로, 배터리 칸 덮개가 없는 모습이다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 6 접수 당시의 Arniston호 발전기로, 배기 안전 덮개가 없는 모습이다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 7 엔진 번호를 보여 주는 사진.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 8 엔진 형식 번호와 형식승인 번호를 보여 주는 사진.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 9 연료 필터 입구 쪽 클립이 고무 연료 호스에 남은 자국으로 보아 원래 위치에서 옮겨져 있었음을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 10 연료 필터 출구 쪽 연료 호스를 고정하도록 되어 있던 클립이 연료 필터 돌출부 하류의 배관 둘레에 느슨하게 걸려 있는 모습.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 11 주입구 목 중간쯤까지 내려가 있는 오일 수위.
보고서
전문 분야: 엔진, 연료, 윤활유, 배기가스
그림 12 Arniston호 발전기의 모습
a) 음극 리드의 전선 단자가 분리되어 있었으나 배터리에는 붙어 있었음, b) 양극 전선 단자의 풀어진 전선 가닥, c) 음극 단자에 생긴 부식, d) 배터리 단자를 보호하는 절연 덮개가 없음.
보고서
전문 분야: 엔진, 연료, 윤활유, 배기가스
그림 13 배터리 단자에 보호 덮개가 장착된 MAIB 발전기.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 14 음극 전원 리드의 전선 단자를 다시 압착한 모습.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 15 노출된 전기 부위를 절연 테이프로 감은 채 배터리에 다시 연결한 전원 리드.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 16 평상시 연료탱크가 놓여 있었을 받침대에 케이블 타이로 고정된 전기 상자.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 17 시동-운전-정지 스위치의 플라스틱 슬리브에 나 있는 자국으로, 발전기를 작동시키기 위해 다른 장치를 사용했을 가능성을 시사할 수 있다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 18 초크 플레이트를 작동시키는 다이어프램 조립체 로드에 남은 접촉 흔적.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 19 35 mm, 60 mm, 85 mm 지점에 표시를 한 열전대 본체.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 20 Arniston호 발전기에서 절약(econ) 스위치를 켠 채 배기 온도 시험을 한 뒤 열전대 끝에서 닦아 낸 물질.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 21 막힌 부분 없이 필터를 통해 빛이 분명하게 통과하는 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 22 초크 작동 장치로, 연선(撚線) 끝이 다이어프램 하우징 본체에 걸려 멈춘 모습(위 이미지)과 그로 인해 하우징에 남은 자국(아래 이미지)을 보여 준다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 23 에어 필터 하우징을 기화기에 고정하는 나사. 공구 자국이 없는 것은 기화기를 분리한 적이 없음을 나타낼 것이다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 24 초크 플레이트 레버가 완전히 닫힌 위치에서 스톱에 맞닿아 있는 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 25 초크 플레이트가 완전히 닫힌 위치에 있는 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 26 초크 플레이트 레버가 스톱에 닿지 못해 완전 개방 위치에 이르지 못한 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 27 연선이 다이어프램 본체에 걸려 초크 플레이트가 완전히 열리지 못한 상태를 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 28 초크 플레이트가 완전 개방 위치에 있는 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 29 'Mityvac' 진공 펌프를 사용하여 다이어프램의 건전성, 개방 부압 및 누설을 점검하는 모습을 보여 주는 이미지.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 30 기화기 플로트 챔버 바닥에서 발견된 모래알 같은 물질.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 31 위 이미지는 기화기 메인 제트를 통과하는 바늘을 보여 준다. 아래 이미지는 0-25 mm 마이크로미터로 바늘의 지름을 재는 모습을 보여 준다.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 32 기화기의 혼합비 조정 나사.
보고서: 전문 분야: 엔진, 연료, 윤활유, 배기가스 그림 33 오일성 퇴적물이나 과열의 흔적이 없는 점화 플러그 끝부분의 이미지. 본체의 탄소 퇴적물은 혼합기가 농후했음을 나타낸다.
부속서 D 보트에서의 일산화탄소 안전 - 보트안전제도(Boat Safety Scheme)와 CoGDEM 보트에서의 일산화탄소 안전 '소리 없는 살인자' 일산화탄소로부터 자신, 선원, 방문객, 반려동물을 보트에서 보호하는 방법 일산화탄소... 위험은 무엇인가? 가스, LPG, 석탄, 목재, 파라핀, 오일, 휘발유, 경유 등 탄소 기반의 기기용·엔진용 연료가 완전히 연소하지 않으면 일산화탄소(CO)가 생성된다.
해마다 보트 이용자가 일산화탄소(CO) 중독으로 사망하거나 중태에 빠진다. 보트는 물이 들어오지 못하게 만들어지지만, 이 때문에 가스와 연기를 가두기도 쉽다. 선실 내 CO 축적은 다음 요인 중 하나 또는 여러 개가 겹쳐 발생할 수 있다. • 결함이 있거나 정비가 불량하거나 잘못 사용된 기기 • 보트의 엔진이나 발전기에서 나오는 배기가스 • 고체연료 스토브에서 새어 나온 연도 가스 • 막힌 환기구 또는 부족한 공기 공급 - 연료가 안전하게 연소하려면 산소가 필요하다 최근 몇 년간 보트 이용자의 CO 중독 사망은 대부분 고체연료 스토브와 엔진 또는 발전기의 배기가스가 원인이었다.
소리 없는 살인자는 어떻게 작용하는가! CO는 몇 분 만에 사람을 죽일 수 있다 - 중독되고 있다고 생각되면 신속히 행동할 준비를 하라! CO는 공기와 무게가 거의 같은 맹독성 가스이다. 고농도에서는 CO가 경고 없이, 때로는 불과 몇 분 만에 사람을 죽일 수 있다. 눈으로 볼 수 없고, 냄새를 맡을 수 없고, 맛을 느낄 수 없고, 느낄 수도 없으므로 '소리 없는 살인자'로 알려져 있다! CO를 들이마시면 혈류 속의 산소를 대체하여 신체 조직, 심장, 뇌 및 기타 주요 장기에 필수적인 공급이 이루어지지 못하게 된다. 심한 CO 중독에서 살아남은 사람도 집중력 저하나 기분 변화 등 장기적인 뇌 손상을 안고 살 수 있다. 낮은 농도의 CO라도 오랜 시간 들이마시면 기억 문제와 집중 곤란 같은 심각한 영향을 겪을 수 있다. 일부 사람은 훨씬 더 빨리 영향을 받는다. • 임신부와 태아 • 영아와 어린이 • 노인 • 호흡기 질환이나 심장 질환이 있는 사람 다른 이유로 위험이 더 높을 수 있는 사람도 있다. • 활동적인 일을 하고 있어 더 빠르고 깊게 호흡하며 산소 필요량이 더 큰 사람 • 과음한 사람 - 증상이 가려질 수 있기 때문이다 선실 공간에 CO가 있으면 모든 사람이 위험하며, 면역이 있는 사람은 아무도 없다!
CO 중독은 슬며시 다가올 수 있다 - 징후를 알아차려라 잠들어 있으면 증상이 진행되어도 알아차리지 못할 수 있다. 깨어 있더라도 흔한 증상 몇 가지를 열거하였으나, CO 중독을 겪는 사람이 모두 이 증상을 전부 보이는 것은 아니다. 흔한 증상은 다음과 같다. • 두통과 짜증 • 메스꺼움과 어지러움 • 피로감과 혼란 • 복통과 구토 자세한 정보는 NHS 웹사이트를 참조하라. http://www.nhs.uk/conditio ns/carbon-monoxidepoisoning 공기 중 CO의 양이 많을수록, 또는 CO를 들이마시는 시간이 길수록 증상은 더 나빠질 수 있다. • 졸음, 무기력, 극심한 피로, 집중 곤란 • 전반적인 쇠약감, 걷거나 움직이기 어려움 • 균형 상실, 시력 및 기억 문제 ...그리고 CO 농도가 매우 높으면 • 흉통 • 심박수 증가 • 호흡 곤란 또는 숨참 • 발작 • 쓰러짐, 의식 상실, 사망 중독이 의심되면 - 신속히 행동하라 빠른 행동이 생명을 구할 수 있다. 스스로 물어보라. '보트에서는 사람들이 아픈데 육지에서는 괜찮은가?' CO 중독이 의심되거나 CO 경보기가 울리면 신속히 행동해야 한다. 모든 사람과 반려동물을 가능한 한 빨리 신선한 공기가 있는 곳으로 내보내고 계속 신선한 공기 속에 머물러라. 가능하면 나가는 길에 기기와 엔진을 끄고... ...문, 창문, 차양도 열어 두어 신선한 공기가 보트 안으로 흐르도록 하라. 지체하지 말고 의료 도움을 구하라! 의사나 간호사에게 일산화탄소 중독을 겪었을 수 있다고 알려라. 다른 선원이나 반려동물이 아프거나 증상이 있으면 그들도 의료 도움이 필요하다. 심한 증상이 있는 사람은 가능한 한 빨리 병원에 가야 한다! 즉시 응급 서비스에 연락하라. 심한 CO 중독은 즉각적인 의료 처치가 필요하다. CO 중독 검사는 노출 직후에만 가능한데, 맑은 공기를 들이마시기 시작하면 곧 흔적이 사라지기 시작하기 때문이다.
보트에서의 위험 징후를 알아 두라 보트의 연료 연소 기기와 엔진에 문제 징후가 없고 상태가 양호한지 정기적으로 점검하면 안전을 지키는 데 도움이 된다. 다음 중 어느 것이든 CO가 보트에 차오르고 있다는 징후일 수 있다. • 기기나 그 연도 주변 표면의 얼룩, 그을음 자국 또는 변색 • 불을 붙이기 어렵거나, 불이 유지되기 어렵거나, 약하게 타는 기기 • 노란색이나 주황색의 '흐느적거리는' 불꽃으로 꺼질 듯한 버너 보트에 CO 문제가 있으면 - 적격한 자격을 갖춘 사람에게 기기나 엔진의 문제를 찾아 고치게 한 뒤에 다시 사용하라. • LPG나 오일 기기를 켰을 때 나는 낯설거나 타는 냄새 • 목재 난로나 석탄 스토브를 가동할 때 연기가 정기적으로 선실로 새어 나오는 것이 냄새로 느껴지거나 보임 고체연료 스토브의 연도 가스는 문제가 있는 가스 레인지 버너에서 발견되는 CO 농도의 최대 100배에 이를 수 있다. • 조종석이나 선실 안에서 엔진 배기가스 냄새가 정기적으로 남 보트에서 CO를 예방하는 방법 CO는 예방할 수 있다. 몇 가지 합리적인 조치를 취하면 위험을 크게 줄일 수 있다. 최신 기준을 충족하고 보트에서 사용하기에 적합한 기기만 구입하라. 기기는 적격한 설치 기사가 올바르게 설치하고 정기적으로 점검 정비하도록 하라. 보트를 자주 또는 장기간 사용하는 경우 기기의 연 1회 점검 정비를 권장한다. 모든 수리에 정품 부품을 사용하도록 하라. 오해해서는 안 된다. 날림 수리나 임시방편 수리는 위험을 초래한다. 기기를 가동하려면 선실 내 공기 공급이 좋아야 한다. 필요한 환기량은 BSS 필수 지침(BSS Essential Guide) 8장의 공식을 이용하여 계산할 수 있다. 선실 환기구가 막히거나 거미줄과 먼지가 쌓이지 않았는지 점검하라. 조리할 때, 특히 LPG 가스레인지에서 큰 냄비를 사용할 때에는 환기를 늘리기 위해 창문을 열어라. 고체연료 스토브는 균열, 없어진 덮개판, 휜 문, 상태가 나쁜 로프 실(seal)이 없는지 점검하라. 기기 사용 설명서를 따르라 - 스토브에 맞는 연료를 올바른 방법으로 태워라. 젖은 연료나 플라스틱 쓰레기를 태우면 연도가 막힐 수 있다. 뜨거운 재와 불씨를 치울 때에는 뚜껑 있는 금속 재통을 사용하고 야외 개방된 곳에 두어라.
연도 파이프와 배기구를 최상의 상태로 유지하라! 보트의 굴뚝 끝을 다리 아치에 부딪쳐 찌그러뜨리면 지갑만 상하는 것이 아니다. 모든 연도나 배기구가 차양, 덮개 있는 갑판 또는 크래치(cratch) 바깥쪽으로 배출되도록 하라. 깨끗한 연도 파이프를 양호한 상태로 유지하면 통풍이 잘 되고 보트에 유독 연도 가스가 차지 않는 데 도움이 된다. 고체연료 스토브의 굴뚝은 최소 연 1회, 심지어 연중 여러 번 청소하라 - 스토브를 많이 쓸수록 굴뚝은 더 자주 청소해야 한다. 모든 기기의 연도 파이프에 녹, 부식 구멍(pitting), 막힘, 느슨하거나 빠진 연결부가 없는지 정기적으로 점검하라. 누설 징후를 살펴라. 연도 이음부의 그을음 자국은 나쁜 징후이다. 환기구와 연도 끝, 특히 선실 지붕 위의 것이 손상되거나, 막히거나, 적재된 장비, 로프, 방수포 또는 장식물에 의해 제한되지 않았는지 확인하라. 모든 문제는 지체 없이, 그리고 장비를 다시 사용하기 전에 해결하라!
선실 공간 안의 엔진 배기가스를 경계하라! 휘발유 발전기와 선외기는 위험할 정도로 높은 농도의 일산화탄소를 내뿜을 수 있으며, 경유 엔진의 배기가스 역시 질병과 사망에 연관된 바 있음을 잊지 말라. 보트의 배기 계통을 정기적으로 점검하라. 매니폴드, 파이프, 이음부, 호스, 클램프, 소음기, 선체 관통 피팅 등 모든 부분에서 누설이나 문제가 없는지 검사하라. 휴대용 발전기를 어떤 거주 공간 안에도 설치하거나 고정하지 말라. 휴대용 발전기를 고정식으로 개조하는 경우에는 정품 개조 키트를 사용해야 한다. 휘발유 엔진의 비효율적인 성능, 설계 온도보다 낮은 온도에서의 엔진 운전, 또는 오염되었거나 오래된 연료의 사용은 배기가스 속 CO 농도를 높일 수 있다. 보트가 움직이는 중이든 계류 중이든, 특정한 운전 및/또는 바람 조건에서는 위험한 수준의 CO가 엔진 배기구에서 방향이 바뀌거나 빨려 들어올 수 있다. 좋은 이웃이 되라. 붐비는 마리나에 계류해 있을 때, 특히 공기가 정체된 때에는 엔진 가동을 피할 수 있는지 살펴라.
위험을 피하라, 다음과 같은 일은 절대 하지 말라 선실 환기구를 절대 막지 말라. 밤새 켜 둘 수 있게 설계되었거나 밀폐형(room sealed)이 아닌 한 LPG 기기를 밤새 켜 두지 말라. 이동식(캐비닛형) 가스 히터는 절대 쓰지 말라 - 보트에 적합하지 않으며 화재 안전상 추가 위험을 만든다. 불이 붙었거나 식고 있는 바비큐를 선실이나 덮개 있는 조종석 구역에 절대 들이지 말라 - 뜨거운 숯은 위험한 양의 CO를 내뿜는다. 숯은 완전히 차갑게 식었을 때에만 안전하다. 기기의 공기 흡입구나 열 배출구를 절대 막지 말라. 연료를 보급할 때를 제외하고는 고체연료 스토브를 문을 연 채 가동하지 말라. 고장이 났거나 안전하지 않다고 생각되는 기기는 절대 사용하지 말라. 연도 끝이 찌그러진 기기는 절대 사용하지 말라. 휴대용 발전기를 선실이나 덮개 있는 조종석 구역, 또는 보트 안으로 열리는 문, 개구부, 환기구 가까이에서 절대 가동하지 말라. 보트의 휘발유 엔진을 배기구가 어떤 식으로든 막힌 채 절대 가동하지 말라. 벽, 다른 보트, 갑문 안 등 높은 옆면을 가진 물체에 보트를 붙여 계류한 경우도 포함한다. 엔진이 가동 중인 보트 가까이에서 절대 수영하지 말라 - 많은 보트의 배기구가 낮은 위치에 있어 수면 높이에서 유독한 대기를 만들 수 있다.
CO 경보기는 생명을 구한다 이중 안전책(벨트와 멜빵) 접근을 취하되 이 점에 유의하라. CO 경보기는 연료 연소 기기와 엔진의 올바른 설치, 정기적인 점검 정비 및 적절한 유지보수를 대신할 수 없다. 선내에 연료 연소 기기, 엔진 또는 발전기가 있다면 추가적인 안심을 위해 적합한 경보음 방식의 일산화탄소 경보기를 설치하라. '블랙 스팟' 색 변환 표시 카드로는 충분하지 않다. 위험한 CO 농도에 대한 즉각적인 경고를 받을 수 없고, 잠을 깨워 주는 경보도 없다. 국제 표준 BS EN 50291-2 를 충족하는 경보기를 설치하라. 이것이 보트에 가장 적합하다. 수명 내내 가는 배터리를 갖춘 경보기도 구할 수 있다. 경보기를 살 때에는 추가적인 보증을 위해 BSi 카이트마크(Kitemark) 또는 LPCB 말굽 '승인' 기호를 찾아라. 경보기 선택이 확실하지 않으면 제조사나 공급업체의 지원 전화로 문의하여 더 조언을 받아라. 보트에 CO 중독 가능성이 있다면 경보기가 없는 것보다 있는 편이 낫다. 청각 장애인을 위한 경보기와 경고 장치도 구할 수 있다.
CO 경보기는 어디에 설치해야 하는가? 연료 연소 기기가 있는 모든 선실에는 CO 경보기를 설치해야 한다. 사람이 자는 동안 연료 연소 기기, 발전기 또는 엔진을 사용한다면 모든 침실에 각각의 경보기가 필요하다. 보트에 다목적 선실이 하나뿐이라면 경보기 하나로 충분하다. 열원이나 증기원 바로 위에는 경보기를 절대 설치하지 말라. 최상의 보호를 위해서는 공간과 보트의 성격이 허용하는 한 경보기 제조사의 설치 지침을 따르라. 그러나 보트에서 설치 위치 지침을 충족하기 어렵다면 다음이 '모범 사례' 요점이다. 경보기를 다음과 같이 설치하도록 하라. • 거실 공간에서는 기기로부터 (평면도상) 1m 이상 3m 이내 • 거실 공간에서는 경보기를 벽 높은 곳에 고정하되 천장에서 최소 150mm 떨어지고 표시등이 보이는 곳 • 침실에서는 경보기를 '호흡 영역', 즉 침대 머리맡 가까이에 둘 것 • 고정하기 전에 보트의 어느 위치에서도 경보음이 들리는지 시험할 것 (또는 경보기를 추가로 구입할 것)
CO 경보기와 함께 생활하기 보트에 처음 탈 때 경보기를 시험하라. 보트를 사용하는 동안에는 매주 경보기를 시험하라. CO 경보기는 영원히 가지 않으며 교체 일자가 표시되어 있다. 그 일자를 넘겨 경보기를 사용하지 말고, 조금이라도 의심스러우면 더 일찍 교체하라. 페인트, 용제, 탈지제 또는 강한 화학약품을 쓰는 작업을 보트에서 할 때에는 센서를 보호하기 위해 경보기를 일시적으로 덮거나 떼어 두어라. 공기가 맑아지는 즉시, 그리고 기기나 엔진을 사용하기 전에 덮개를 벗기거나 경보기를 다시 설치하는 것을 잊지 말라. 월동 준비를 한 보트에서는 경보기를 떼어 두는 것을 고려하라. 영하의 온도가 오래 지속되면 센서와 배터리에 영향을 줄 수 있기 때문이다. 월동 준비 후에는 경보기를 반드시 다시 설치하라. 그리고 어떤 기기나 엔진을 사용하기 전에 경보기를 시험하라. 다음 사항에 유의하라. CO 경보기는 감지만 할 뿐, 일산화탄소의 위험한 축적을 막을 수는 없다. CO 경보기는 특정한 질환이 있는 사람을 완전히 보호하지 못할 수 있다. CO 경보기는 화재, 연기, 또는 휘발유나 LPG 연료 증기의 누출을 감지하지 못한다. CO 경보기는 폭발성 가스인 수소를 감지해도 작동할 수 있다. 예를 들어 충전 중 보트의 배터리에서 가스가 발생하는 경우로, 이는 충전 문제를 나타낼 수도 있다.
수상 세입자인 경우 법은 세입자에 대한 여러 가지 추가 보호를 제공하며, 그 가운데 다음이 있다. 집주인이 LPG 기기를 제공한 경우, 집주인은 가스 안전(Gas Safe) 등록 기사가 연 1회 가스 안전 점검을 실시하도록 조치해야 한다. 임대 보트의 세입자로서 CO에 대한 우려가 있다면, 지체 없이 집주인이나 임대 중개인에게 문제를 제기하라. 우려가 해결되지 않으면 지방 의회에 도움을 요청하라. 몸이 좋지 않다고 느끼면 즉시 의료 도움을 받아라. 세입자를 위한 더 많은 정보는 www.hse.gov.uk/gas/domestic/faqtenant.htm 과 www.gov.uk 의 민간 임대 숙박시설 건강·안전 페이지를 참조하라. CO와 보트 이용에 관한 추가 정보 보트에서의 CO와 화재 안전 및 정기 안전 점검 항목에 관한 더 많은 정보 - 보트안전제도(Boat Safety Scheme): www.boatsafetyscheme.org/stay-safe 경보기 정보 - 가스감지·환경감시협의회(Council of Gas Detection and Environmental Monitoring, CoGDEM) cogdem.org.uk/CoGDEMCOsite/index.html 일반적인 CO 조언 - 영국 보건안전청(HSE) 가스 안전 상담 전화 0800300363 www.hse.gov.uk/gas/domestic/co.htm 가스 안전 등록(Gas Safe Register) - 등록된 가스 설비 기사를 찾으려면 www.gassaferegister.co.uk 영국 해양산업연맹 - 지역 보트 수리장을 찾으려면 www.britishmarine.co.uk CO 문제에 관심을 가진 자선단체 일산화탄소·가스안전협회(The Carbon Monoxide and Gas Safety Society) www.co-gassafety.co.uk CO-Awareness www.covictim.org 가스안전재단(Gas Safety Trust) www.gas-safety-trust.org.uk 가스안전자선단체(Gas Safe Charity) www.gassafecharity.org.uk CO-Angels www.co-angels.co.uk 감사의 말 CoGDEM 은 가스 감지 분야의 기업과 전문가를 대표하는 영국의 업계 단체이다. CoGDEM 은 영국, 유럽 및 세계의 표준 제정 기구에 전문 지식을 제공하며, HSE 를 포함하여 모든 CO 인식 제고 프로젝트와 기관에 기술 지침과 지원을 제공한다. 이 정보는 CO 경보기를 생산하는 CoGDEM 회원사의 지원을 받았다 www.cogdem.org.uk 가장 필요한 곳에 가스를 안전하게 만드는 데 직접 도움을 주는 가스안전자선단체(Gas Safe Charity)의 후한 지원으로 발행되었다. 저자들은 특히 의학 정보와 관련하여 도움을 준 잉글랜드 공중보건청(Public Health England) 직원들에게 감사드린다. 저자들은 HSE 리플릿 '가스 기기 - 점검받고 안전하게 유지하라(Gas Appliances - Get them checked, Keep them Safe)'(참조: INDG238(rev2))와 보건부 리플릿 289814 '일산화탄소: 당신은 위험한가?(Carbon monoxide: Are you at risk?)'를 원 자료로 인용하였음을 밝힌다. 디자인은 Fire Kills 의 허락을 받아 '보트 화재 안전(Fire Safety On Boats)' 리플릿을 바탕으로 하였다 www.gov.uk/firekills 저자들은 삽화 작업을 도와준 Safelincs(연기 경보기, CO 경보기 및 기타 안전 장비 공급업체)에 감사드린다 www.safelincs.co.uk 주문형 PDF 및 웹 구현은 Plan9 www.plan9.co.uk CO는 생명을 위협한다 - 안전하게, 경각심을 갖고 지내라. 연료 연소 기기를 올바르게 설치하라 기기와 엔진을 정기적으로 점검 정비하라 장비를 올바르게 사용하라 엔진 배기가스가 선실 공간으로 들어오지 못하게 하라 문제는 즉시 해결하라 불이 붙었거나 식고 있는 바비큐를 덮개가 있는 구역에 절대 들이지 말라 날림 수리와 정비를 허용하지 말라 CO 경보기를 설치하라 경보기를 정기적으로 시험하라 배터리를 절대 빼지 말라 CO 중독의 징후와 대응 방법을 알아 두라 저작권은 보트안전제도(Boat Safety Scheme)와 CoGDEM 의 소유자들이 공동으로 보유한다. 이 출판물은 광고, 보증 또는 상업적 목적을 제외하고 자유롭게 복제할 수 있다. 출처를 보트안전제도 & CoGDEM 으로 밝혀 주기 바란다. 식물성 잉크를 사용하여 Greenshires 가 재생지에 인쇄함 보트에서의 일산화탄소 안전 v3 2014년 4월
부속서 E MAIB 안전 회보 2/2013
MAIB 안전 회보 2/2013 컴브리아주 윈더미어(Windermere, Cumbria)에서 Bayliner 285 모터 크루저 Arniston호에서 발생한 일산화탄소 중독으로 2명 사망 영국 해양사고조사국 Mountbatten House Grosvenor Square Southampton SO15 2JU MAIB 안전 회보 2/2013 안전 교훈이 담긴 이 문서는 현재까지 입수된 정보를 바탕으로 해양 안전 목적으로만 작성되었다. 2012년 상선(사고 보고 및 조사) 규칙(The Merchant Shipping (Accident Reporting and Investigation) Regulations 2012)은 해양사고 수석조사관이 조사 도중 언제든지, 그렇게 하는 것이 필요하거나 바람직하다고 판단하면 권고를 할 수 있도록 규정하고 있다. 영국 해양사고조사국은 2013년 4월 1일 모터 크루저 Arniston호에서 발생한 2명의 사망에 대한 조사를 진행하고 있다. MAIB는 조사가 끝나면 전체 보고서를 발간할 것이다. 스티브 클린치(Steve Clinch) 해양사고 수석조사관 주의 이 회보는 소송을 염두에 두고 작성된 것이 아니며, 2012년 상선(사고 보고 및 조사) 규칙 제14조(14)항에 따라, 책임이나 과실을 배분하는 것을 목적 또는 목적 중 하나로 하는 어떠한 사법 절차에서도 증거로 인정되지 않는다. 이 회보는 당사 웹사이트에서도 볼 수 있다: www.maib.gov.uk 언론 문의: 020 7944 3387/6433; 업무 시간 외: 020 7944 4292 일반 문의: 0300 330 3000 배경 11년 된 Bayliner 285 모터 크루저에서 맞이한 공휴일 주말이 어머니와 10살 딸의 죽음으로 비극적으로 끝났다. 초기 조사 결과 사망자들은 일산화탄소에 중독된 것으로 보인다. 초기 조사 결과 '여행 가방' 형태의 휴대용 휘발유 발전기(그림 1)가 보트에 240v 전력을 공급하기 위해 모터 크루저의 기관실에 설치되어 있었다. 이 발전기에는 임시로 만든 배기 및 소음기 계통이 갖춰져 있었는데, 이것이 발전기와 선측 배출구 양쪽에서 모두 분리되어 있었다(그림 2 및 3). 그 결과 발전기의 배기가스가 기관실을 채우고, 내부 격벽의 틈을 통해 어머니와 딸이 자고 있던 선미 선실로 퍼졌다. 보트 소유자는 선수 선실에서 깨어났을 때 일산화탄소 중독 증상을 겪고 있었으나 경보를 울릴 수 있었다. 어머니와 딸은 소생시킬 수 없었다. 보트의 일산화탄소 센서 계통은 전원에 연결되어 있지 않아 경보를 울리지 못하였다. 그림 1 휘발유 발전기
그림 2 소음기
그림 3 소음기 배기 배출구
안전 쟁점 1. 휴대용 공랭식 휘발유 발전기는 쉽게 구할 수 있고 저렴하지만, 보통 옥외에서 사용하도록 만들어진 것이다. 이러한 엔진을 보트에, 특히 밀폐구역이나 갑판 아래에 사용하거나 영구 설치하면 일산화탄소 중독의 위험이 커진다. 2. 엔진 배기 계통은 유독 가스를 환기 흡입구와 거주 공간에서 떨어진 선외로 배출하도록 설치·유지하는 것이 필수적이다. 따라서 이러한 계통에 대한 작업은 적격한 해양 정비 기술자가 승인된 부품을 사용하고 장비 제조사의 해양 설치 지침을 따라서만 수행해야 한다. 3. 일산화탄소는 냄새도 맛도 색도 없는 치명적인 가스로, 사람의 감각으로 감지하기가 극히 어렵다. 모든 보트 이용자는 경각심을 갖고 일산화탄소 중독의 징후를 알아차려야 하며, 그 징후에는 두통, 어지러움, 메스꺼움, 구토, 피로, 혼란, 복통 및 숨참이 포함될 수 있다. 4. 일산화탄소는 육상에서만큼이나 물 위에서도 치명적인 소리 없는 살인자이다. 보트의 전원으로 작동하는 것이든 독립형이든 모든 일산화탄소 센서를 올바르게 배치하고 정기적으로 시험하는 것이 필수적이다. 제대로 작동하지 않는 일산화탄소 센서 경보기는 교체해야 한다. 일산화탄소 경보기를 고를 때에는 해양 환경에서 사용하도록 만들어진, 안전 기준 EN 50291-2:2010 을 충족하는 것으로 표시된 제품을 우선해야 한다. 보트안전제도(Boat Safety Scheme, BSS)와 가스감지·환경감시협의회(Council of Gas Detection and Environmental Monitoring, CoGDEM)가 작성한, 보트에서 일산화탄소 중독을 피하는 방법과 일산화탄소 경보기에 관한 더 자세한 조언은 다음에서 볼 수 있다. http://www.boatsafetyscheme.org/stay-safe/carbon-monoxide-(co) 2013년 5월 발행