Source: Marine Accident Investigation Branch (GOV.UK). Contains public sector information licensed under the Open Government Licence v3.0. — PDF 에서 글을 뽑아 줄을 잇고 호칭 뒤의 인명을 가린 것으로, 원문과 다를 수 있습니다.
용어 밑줄은 영어 사전으로 붙입니다. 조문 연결·대목 나누기·원인 키워드는 국내 재결용 규칙이라 이 자료에는 적용되지 않습니다.
사고 경위, 조치 사항 및 권고를 포함한 해양사고 조사 보고서를 읽어 보십시오.Read our marine accident investigation report, which includes what happened, actions taken and recommendations:
2012년 8월 10일 애버딘(Aberdeen) 동쪽 45마일에서 발생한 어선 Audacious호의 침수 및 침몰과, 2012년 9월 1일 데번(Devon) 볼트 헤드(Bolt Head) 남서쪽 17마일에서 발생한 어선 Chloe T호의 침수 및 침몰에 관한 MAIB 조사 보고서.MAIB Report on the investigations of the flooding and foundering of the fishing vessel Audacious 45 miles east of Aberdeen on 10 August 2012, and the flooding and foundering of the fishing vessel Chloe T 17 miles south west of Bolt Head, Devon on 1 September 2012.
안전 쟁점Safety Issues
두 선박 모두 기관실이 급속히 침수되었고 빌지 펌프가 유입량을 감당하지 못하였다the engine room of both vessels flooded rapidly and the bilge pumps were unable to cope with the ingress
두 사고 모두 선박의 해수 냉각 계통 고장이 원인이었을 가능성이 높다it is likely that both accidents were caused by the failure of the vessels’ seawater cooling systems
승무원들은 해수 흡입 밸브가 침수된 물에 곧 잠겨 이를 닫을 수 없었다the crews were unable to close seawater inlet valves because they became quickly submerged by flood water
Audacious호에서는 빌지 경보가 작동하였으나, 한동안 조타실이 비어 있어 초기에 감지되지 못하였다on Audacious, the bilge alarm activated but this was not detected at an early stage because the wheelhouse was unmanned for a period
원본 PDF 의 사진·그림 가운데 ‘courtesy of …’ 표시가 있는 것은 제3자 저작물입니다(공공 라이선스 밖). 이 화면에서 보는 데만 쓰세요.
Chloe T호에서는 선박에 설치된 빌지 경보가 작동하지 않았을 가능성이 높다on board Chloe T, it is likely that the bilge alarms fitted to the vessel were inoperative
권고Recommendations
영국 해사연안경비청에는 어선 검사 및 점검의 범위, 일정, 적용 및 기록 보존을 개선하도록 하는 권고(2013/249 및 250)가 이루어졌다.Recommendations (2013/249 & 250) have been made to the MCA which seek to improve the scope, scheduling, application and record keeping for surveys and inspections of fishing vessels.
Audacious호의 선주에게는 선교 당직 수준과 관련한 권고(2013/251)가 이루어졌다.A recommendation (2013/251) has been made to the owner of Audacious regarding bridge watchkeeping standards.
스코틀랜드 어민연맹, 전국 어민단체연합(National Federation of Fishermen’s Organisations) 및 북아일랜드 수산물 생산자 기구(Northern Ireland Fish Producers Organisation)에는 이 사고와 Audacious호 사고에서 얻은 교훈, 특히 어선 운영자가 해수 배관을 철저히 점검해야 할 필요성을 회원들에게 알리도록 권고되었다(2013/252).The Scottish Fishermen’s Federation, the National Federation of Fishermen’s Organisations and the Northern Ireland Fish Producers Organisation have been recommended (2013/252) to promulgate the lessons learned from this accident and that of Audacious, and particularly the need for fishing vessel operators to thoroughly inspect seawater pipework, to their members.
이 보고서는 2013년 12월 19일에 발간되었다.This report was published on 19 December 2013.
한국어는 모델 번역(검수 전)입니다. 표의 값은 흔한 말만 옮기고 나머지는 원문 그대로 둡니다.
본문
PDF 에서 뽑은 글 — 쪽 나눔·단 배치 때문에 줄 순서가 어긋난 곳이 있을 수 있습니다
영국 해양사고조사국 사고 보고서 매우 심각한 해양사고 보고서 제27/2013호 2013년 12월 2012년 8월 10일 애버딘(Aberdeen) 동쪽 45마일에서 발생한 어선 Audacious호의 침수 및 침몰과, 2012년 9월 1일 데번(Devon) 볼트 헤드(Bolt Head) 남서쪽 17마일에서 발생한 어선 Chloe T호의 침수 및 침몰에 대한 조사 보고서 2012년 영국 상선(사고 보고 및 조사) 규칙 제5조에서 발췌: "2012년 상선(사고 보고 및 조사) 규칙에 따른 사고 조사의 유일한 목적은 그 원인과 상황을 규명하여 장래의 사고를 방지하는 것이다. 조사의 목적은 책임을 판단하는 것이 아니며, 그 목적을 달성하는 데 필요한 경우를 제외하고는 과실을 배분하는 것도 아니다."
참고 이 보고서는 소송을 염두에 두고 작성된 것이 아니며, 2012년 상선(사고 보고 및 조사) 규칙 제14조(14)에 따라, 책임이나 과실을 귀속시키거나 배분하는 것을 목적(또는 목적 중 하나)으로 하는 어떠한 사법 절차에서도 증거로 인정되지 아니한다.
귀하는 이 문서/간행물(부처 또는 기관의 로고는 제외)을 어떠한 형식이나 매체로도 무료로 재사용할 수 있다. 정확하게, 그리고 오해를 일으키지 않는 맥락에서 재사용하여야 한다. 자료는 영국 왕실 저작권으로 명시하여야 하며 원 간행물의 제목을 밝혀야 한다. 제3자의 저작권 자료임을 확인한 경우에는 해당 저작권자의 허락을 받아야 한다.
모든 MAIB 간행물은 당 기관의 웹사이트에서 찾을 수 있다
www.maib.gov.uk
Audacious호 표지 사진 제공
Trawler Photos
모든 문의처: 영국 해양사고조사국(Marine Accident Investigation Branch) Mountbatten House Grosvenor Square Southampton 이메일: maib@dft.gsi.gov.uk 영국 전화: +44 (0) 23 8039 5500 SO15 2JU 팩스: +44 (0) 23 8023 2459
보고서 목차(쪽 번호는 원본 PDF 기준)
목차 쪽 약어 및 두문자어 용어집 해양사고 수석조사관의 머리말 AUDACIOUS호 요약 1 1절 사실 정보 2 1.1 Audacious호와 사고의 세부 사항 2 1.2 배경 3 1.3 경위 4 1.3.1 사고 이전의 사건 4 1.3.2 기관실 침수 6 1.3.3 퇴선과 구조 8 1.4 환경 조건 10 1.5 선원 10 1.6 선박의 일반 설명 10 1.6.1 기관실 12 1.6.2 해수 냉각 계통 12 1.6.3 빌지 배수 계통 13 1.6.4 빌지 경보 13 1.7 복원성 및 침수율 조사 13 1.8 규제 요건 13 1.8.1 법정 체계 13 1.8.2 15-24m 규약 14 1.8.3 기술 요건 14 1.9 법정 검사와 점검의 수행에 대한 요건 및 지침 15 1.9.1 검사원에 대한 지침 15 1.9.2 기타 지침 17 1.10 증서 발급 및 검사 이력 18 1.10.1 증서 발급 이력 18 1.10.2 선체 두께 계측 20 1.11 정비 이력 20 1.12 어선에서의 안전한 항해당직 유지 20 1.13 어선: 선원 자격증명, 훈련 및 훈련 연습 20 1.13.1 어선 선원에 대한 훈련 및 자격증명 요건 21 1.13.2 어선: 선원 자격증명 및 훈련 연습 점검 21 1.13.3 안전 인식(해상 안전 관리) 과정 21 2절 분석 22 2.1 목적 22 2.2 요약 22 2.3 항해당직/경계 22 2.4 기관실 침수/복원성 22 2.4.1 침수의 원천과 침수율 22 2.4.2 복원성 23 2.4.3 연장 스핀들 23 2.4.4 수밀문 24
2.5 퇴선 24 2.6 UKFVC – 검사와 점검의 일정 수립 24 2.7 연례 자체 증명 25 2.8 검사원에 대한 MCA 지침 25 2.8.1 냉각수 배관 검사 25 2.8.2 비망록 26 2.9 MCA의 기록 관리 26 CHLOE T호 요약 27 3절 사실 정보 28 3.1 Chloe T호와 사고의 세부 사항 28 3.2 배경 29 3.3 경위 29 3.3.1 매입과 숙지 29 3.3.2 준비와 조업 30 3.3.3 마지막 항해 30 3.3.4 조업 30 3.3.5 경보 31 3.3.6 비상 조치 31 3.3.7 악화 33 3.3.8 퇴선 33 3.3.9 구조 35 3.4 선원과 주요 인원 38 3.4.1 선원 38 3.4.2 기타 주요 인원 39 3.5 기관 배치 39 3.5.1 주기관 39 3.5.2 발전기 40 3.5.3 빌지 배수 40 3.5.4 갑판 세척 40 3.5.5 기타 해수 계통 40 3.5.6 빌지 경보 41 3.6 정비 및 검사 이력 41 3.6.1 공식 기록 41 3.6.2 선박의 초기 이력 41 3.6.3 UKFVC 갱신을 위한 검사 - 2002년 42 3.6.4 UKFVC 갱신을 위한 검사 - 2006년 42 3.6.5 2007년과 2011년 사이의 점검 44 3.6.6 UKFVC 갱신을 위한 검사 – 2011년 44 3.6.7 기타 검사와 점검 45 4절 분석 46 4.1 목적 46 4.2 기관실 침수 46 4.2.1 침수의 잠재적 원천 46 4.2.2 선체 외판 파손 46 4.2.3 해수 계통 파손 47 4.2.4 침수율 48 4.2.5 가장 가능성이 높은 원인 48
약어·용어집GLOSSARY OF ABBREVIATIONS AND ACRONYMS
15-24m Code Code of Safe Working Practice for the and Use of 15m (LOA) to 24m (RL) vessels AC - Alternating Current - Automatic Identification System CM - Consultative Marine - Certificate of Competency - International Regulations for Preventing Collisions at Sea 1972 (as amended) DC - Direct Current - Emergency Position Indicating Radio Beacon FSM - Moment knots - Measurement of : 1 knot = 1 nautical mile per hour LOA - Length overall m - metre
사실SECTION 1 - FACTUAL INFORMATION
1.1 OF AUDACIOUS AND ACCIDENT SHIP PARTICULARS Vessel’s name Audacious Flag British Not applicable numbers BF 83 Type Twin rig Registered owner Deveron Fishing Company, Buckie Manager(s) Deveron Fishing Company, Buckie , built Navia, Spain, 1999 27.60m 23.95m 437 Not applicable Authorised cargo No
분석SECTION 2 - ANALYSIS
2.1 AIM The purpose of the analysis is to determine the contributory causes and circumstances of the accident as a basis for making recommendations to prevent similar accidents occurring in the future. 2.2 SUMMARY It was not possible to inspect Audacious due to the remote location of the . Analysis of the available evidence indicated that the vessel due to rapid water ingress to its that, initially, went undetected. The rate of water ingress indicates that it was due to the failure of seawater cooling pipework. There was no evidence to suggest that the vessel had been sunk deliberately. 2.3 / The left the wheelhouse unattended on several occasions during the 30-minute period before he noticed the change in tone of the . He had gone onto to check the progress of the net repairs and had also spent time in the , preparing and cooking a meal for the . Rule 5 of the
Annex E 15 to 24 metre Vessels Survey/Inspection Aide-Mèmoir ()
Rev 1 Sep 07
INSPECTION ITEMS REQUIRED , with lights 1 per person + 2 spare Liferafts - for sea area A1, where only 1 raft may be carried Liferafts - for sea area A1 and A2 and all Trawlers Lifebuoys, 1 with light and smoke signal, 1 with 18 m buoyant line Means of recovering a person from the water 1 Parachute Flares (/MED Approved) 6 Hand held flares (SOLAS/MED Approved) 4 Smoke Signal (SOLAS/MED Approved) 2 Line Throwing Apparatus (SOLAS/MED Approved) , including audible and visual alarms (new builds show location of ) Fixed Fire Fighting System for 1 Fixed Fire Fighting System for if Structural Fire Protection not provided Power Operated and hose/s – 15 m /hr at pressure 2 kg/m suitable for 3 Fire Extinguisher suitable for oil fires 2 Capacities of
(inc, whistles, retro-reflective material and lights) Encourage owners and to working lifejackets at all times (Constant Wear Equipment)
Table or curve of residual deviations for magnetic provided Operational and, where appropriate, maintenance manuals for all provided Charts and nautical publications necessary for intended available and up-dated. Operation of two-way apparatus Operation of – annual test certificate provided lights, shapes and sound signalling equipment Parachute flares are not out of date Hand-held flares are not out of date Smoke signal/s are not out of date Line throwing rockets and strikers are not out of date Examining and testing detection and alarm system, if fitted As appropriate, the magnetic compass, compass, installation, , echo- device, and distance indicator,
Fixed fighting system for , as appropriate, and means of operation clearly marked Fire Blanket in galley arrangements Gas detection and alarm system, condition and test
Factory Valves
Rev 1 Sep 07
SURVEY / INSPECTION General Y N N/A Safety Signs 1 Poster Safety belts/harnesses – more than 5 SpacesMain and Auxiliary engines, condition, guards, exhaust, no exposed high temperature surfaces, fuel linesRemote Electrical Stops Arrangements for oil fuel, and other flammable oils. Operation of remote means of quick closing valves on tanks that contain oil fuel, lubricating oil and other flammable oils pumping – test of /s and bilge alarms Bilges, condition, no oil being pumped overboard. Disposal arrangements for Oily water Fixed fighting system for : /FM 200 etc. capacity has been checked. Distribution pipework proved clearCompressed air systems Condition of pipework, clips, skin fittings,
Electrical systems – alternators, motors etc. Electrical cables – condition, securely clipped, electrically safe Batteries, condition (Emergency and Radio) Emergency Escape routes, not obstructed, clearly marked Bulkheads, frames, condition doors, flaps etc. condition , condition, operational test Record of Planned Maintenance – see MT 4 questionnaire Fire risks and hazardsOUT OF WATER SURVEY (INTERMEDIATE/) YNN/A Condition of Hull – Ultrasonic test and report Keels Sea Chests Sacrificial AnodesWood – condition of planking, nails, caulking etc. Aluminium - condition – condition, gel coat, damage, osmosis etc.
condition Report Clearances Lubrication Kort Nozzle condition Rudder ClearancesCondition of sea inlets and valves/cocks Marks – Condition/accuracy and Chain cable condition
COMPLETION OF SURVEY YNN/A
Should there be any doubt before completion of the survey/inspection contact the Principal or local Marine Office for advice issued or endorsed; Inspection report left with Owner/ Record of Equipment (check ) left with Owner/Skipper
Doc No
MSF 5550 15 TO 24 METRE VESSELS SURVEY/INSPECTION AIDE-MEMOIR (Based on the 15 – 24 m Code of Safe Working Practice)
Name of Vessel Date Revision
16/09/09
CERTIFICATES AND RECORDS Y N N/A Validity of UK Certificate ( carried out?) Self Certification form Signed annually by the owner Radio Survey carried out at appropriate intervals
Validity of Note; change of ownership and/or modifications to the vessel such as change of length, etc. will require that the Certificate of Registry be renewed/amendedValidity of Training Certificates Basic Safety Awareness Sea Survival Fighting First AidValidity of Servicing certificates for Appliances Life Rafts etc Copies on board/available in Risk Assessment folder Note; change of ownership or change of mode of will require amended/new Risk AssessmentsAny new equipment fitted meets current rules/fit for purpose etc. Has any occurred on board necessitating the operation of the fixed fire-extinguishing systems or the portable fire extinguishers since the last survey;
Safety Drills carried out and recorded Any requirements for Concentrated campaign or inspection have been confirmed – see any separate instructions
~lAS UK & DT Inspection/Survey Details Ship Details Ship ID 41 883 Next ID 63534 Group ID 30088 Ship Name CHLOE T Number 0000000 FV Number PZ1186 Ship Type F1 - - Flag 670- UNITED KINGDOM Class. Society 0 - NONE Official Number 810739 Sign MLVY3 OWner Year of Build 1968 Kw 313 Length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 19/03/2002 Detained? N Country UNITED KINGDOM Place Newlyn Inspection In conjunction with a Type survey MACRIS Codes Comments Ship Actions UK Class Code X 000136 Input Date 28/03/2002 Release Date Inspected at N Sea? Inspection has no ship actions Survey Details Survey Type FVA(F!) Category A Survey - Fishi!l9 Vessel (PART) fLO Survey Details Inspection has no fLO SurveyCertificate Details FVC UN I TED 09/04/1998 24/0212002 KINGDOM UKE UNITED KINGDOM 01/06/2000 24/02/2002 Deficiency Details • 's Description 299 Record of competancies to supply (form provided) 350 One light to shade 371 First aid kit to re-certify 520 One light to repair in net store 599 Winchouse non-return valves to
4.3 침수 경고 48 4.3.1 일반 원칙 48 4.3.2 Chloe T호의 빌지 경보 49 4.3.3 보조 빌지 경보 49 4.4 비상 대응 49 4.4.1 침수에 대한 대응 49 4.4.2 퇴선 49 4.5 선주와 선원의 역할 49 4.5.1 책임 49 4.5.2 매입과 숙지 51 4.5.3 운용 51 4.6 법정 검사 체계의 실효성 51 4.6.1 검사와 점검의 일정 수립 51 4.6.2 검사의 범위와 기준 준수 52 4.6.3 기록 관리 54 4.6.4 면제 54 4.6.5 요약 54 AUDACIOUS호/CHLOE T호 5절 유사 사고 56 5.1 어선 Vellee호의 침수 및 침몰, 2011년 8월 6일 56 5.2 영국 어선 안전 분석 1992 - 2006 56 6절 논의 57 6.1 침수 57 6.2 예방 57 6.2.1 배관 노후화 57 6.2.2 검사와 점검 57 6.3 감지 58 6.3.1 조기 경보 58 6.3.2 작업 관행 58 6.4 긴급 대응 59 6.4.1 침수에 대한 즉각적 대응 59 6.4.2 배수 59 6.4.3 복원성 59 6.4.4 퇴선 59 7절 안전 쟁점 61 7.1 침수 원인 61 7.2 해수 배관 상태 평가 61 7.3 침수 감지 61 7.4 침수 비상 대응 61 7.5 법정 검사와 점검의 실효성 62 8절 조치 사항 63 8.1 다른 기관의 조치 63 9절 권고 64
그림 Audacious호 그림 1 - 상갑판과 주갑판에 펼쳐진 찢어진 그물 그림 2 - 기관실 그림 3 - 보조 기관이 보이는 기관실 그림 4 - 거주구역 통로 그림 5 - 우현 선체 사다리 그림 6 - Audacious호 침몰 과정 그림 7 - 전 길이 작업 구역이 보이는 상갑판 그림 8 - 조타실 – 선수 쪽 콘솔 방향 시야 Chloe T호 그림 9 - Chloe T호의 기관실 배치 - 선원 기억에 기초한 개략도 그림 10 - Chloe T호 – 일반 배치도 그림 11 - Chloe T호(1757시에 촬영한 사진) 그림 12 - Chloe T호(1855시에 촬영한 사진) 그림 13 - Chloe T호(2013시에 촬영한 사진) 그림 14 - Chloe T호(2020시에 촬영한 사진) 부속서 부속서 A - 기관실 침수 자료(Audacious호) 부속서 B - 웰형 기관 설계 단면도(Audacious호) 부속서 C - 2008년 12월 발급된 UKFVC(Audacious호) 부속서 D - 2011년 7월 MCA 만재흘수선 검사 보고서(Audacious호) 부속서 E - 15~24미터 어선 검사/점검 비망록(Aide-Mémoire)(MCA) 부속서 F - SIAS 기록(Chloe T호) 부속서 G - 어선 세부 사항 기록(Chloe T호) 부속서 H - 침수율 계산식
-
Maritime and Coastguard Agency
MDI - Marine Data International
-
Marine Guidance Note
mm - millimetre
-
Maritime Rescue Co-ordination Centre
MSF - Marine Survey Form
- Marine Survey Instructions to Surveyors
-
Merchant Shipping Notice
RL -
Registered Length
-
Royal National Lifeboat Institution
SI - Statutory Instrument
-
Ship Inspection and Survey
t - tonnes
tm - tonne metre
-
United Kingdom Fishing Vessel Certificate
-
-
Very High Frequency
Times: All times used in this report are
UTC
+1 unless otherwise stated
INTRODUCTION BY THE
The Buckie based twin rigged
“Audacious” and the Brixham based
trawler
“Chloe T” suffered
and
during August and September 2012 respectively. Fortunately both crews survived their ordeals and it has been possible for
inspectors to gain a comprehensive understanding of the causes and circumstances of the accidents, notwithstanding the
of both vessels. The outcomes of these investigations have been combined into a single report. The safety issues that have been identified during the
MAIB
investigations are remarkably similar: the
of both vessels
flooded
rapidly and the
pumps were unable to cope with the ingress; it is likely that both accidents were caused by the failure of the vessels’ seawater cooling systems; the crews were unable to close seawater inlet valves because they became quickly submerged by flood water; on Audacious, the
bilge
alarm activated but this was not detected at an early stage because the wheelhouse was unmanned for a period; on board Chloe T, it is likely that the
bilge
alarms fitted to the vessel were inoperative. The responsibility for ensuring that the structural integrity and safe operation of
fishing
vessels, together with the safety of their crews, rests firmly with vessel owners. However, the
Maritime and Coastguard Agency
’s (
MCA
) inspection and survey regime is intended to provide an appropriate level of oversight and scrutiny to ensure that vessel owners are
their safety responsibilities. Both investigations reach the conclusion that the instructions provided to
MCA
surveyors with respect to important issues such as the testing and inspection of seawater pipework systems need to be improved. Of more concern is that both investigations also identified that the record keeping and management systems used by
MCA
surveyors require significant improvement. Missing intermediate inspections, and delays in the
survey process were noted in both cases; it is unlikely that either vessel received the level of oversight that was intended by the
MCA
’s instructions to its surveyors. It is disappointing to note that similar observations were made by the
MAIB
following the
loss
of the
Harvest Hope1 in August 2005. At that time the
MCA
undertook to conduct an internal inquiry into the identified shortfalls but, nonetheless these weaknesses appear to remain more than 7 years later. Accordingly, recommendations have been made to the
MCA
which seek to improve the scope, scheduling, application and record keeping for surveys and inspections of
fishing
vessels. That
MCA
surveyors are provided with effective management support tools, and apply well considered survey and inspection procedures in a uniform way is important for the safety of our
but is also a prerequisite to maintaining the Agency’s authority amongst its
stakeholders. Steve Clinch
Chief Inspector of Marine Accidents
1
MAIB
Report 21/2006
FLOODING
AND
FOUNDERING
OF FV AUDACIOUS - SYNOPSIS On 10 August 2012, the
engine room
of the 23.7m twin-rig
stern
trawler
Audacious
flooded
while the vessel was
fishing
, in calm weather conditions, 45 miles east of Aberdeen. The
were unable to stop the ingress of water and
shortly before the vessel
sank
at 1554. The
, who was the sole
, was in the
when he heard the tone of the vessel’s
alter and returned to the wheelhouse to find that the
engine room
bilge
alarm had activated. It was discovered that water had entered the
engine room
and was level with the top of the
. A
was started but the
sea
inlet valves could not be closed as they were underwater and it was evident to the
crew
that nothing could be done to stop the ingress of water. The
skipper
broadcast a “Mayday” distress message and activated the vessel’s
Emergency Position Indicating Radio Beacon
. The
crew
abandoned to a
a few minutes before the vessel
sank
and were subsequently rescued, unharmed, by a vessel that had responded to the “Mayday”. The
MAIB
investigation of the accident found that the
flooding
was probably due to the failure of the
sea
inlet pipework in the
engine room
, and that the wheelhouse had been unmanned for periods prior to the accident. It was also found that statutory surveys and inspections had not been undertaken in accordance with the terms and conditions of the vessel’s UK
fishing vessel
certificate. Recommendations have been made to the vessel’s owner regarding
standards.
한국어 번역 · 모델 · 검수 전
약어 및 두문자어 용어집
15-24m 규약 - 전장(LOA) 15m부터 등록 길이(RL) 24m까지 어선의 건조 및 사용을 위한 안전작업 실무규약(Code of Safe Working Practice for the Construction and Use of 15m length overall (LOA) to 24m registered length (RL) fishing vessels)
AC - 교류(Alternating Current)
AIS - 선박자동식별장치(Automatic Identification System)
CM - 자문 해사(Consultative Marine)
CoC - 해기 자격증명(Certificate of Competency)
COLREGS - 국제해상충돌예방규칙(International Regulations for Preventing Collisions at Sea 1972 (as amended))
DC - 직류(Direct Current)
EPIRB - 비상위치지시용 무선표지(Emergency Position Indicating Radio Beacon)
MSIS - 검사원에 대한 선박검사 지침(Marine Survey Instructions to Surveyors)
MSN - 상선 고시(Merchant Shipping Notice)
RL - 등록 길이(Registered Length)
RNLI - 영국 왕립구명정협회(Royal National Lifeboat Institution)
SI - 법정 문서(Statutory Instrument)
SIAS - 영국 선박검사 기록(Ship Inspection and Survey)
t - 톤
tm - 톤미터
UKFVC - 영국 어선 증서(United Kingdom Fishing Vessel Certificate)
UTC - 협정 세계시(Universal Co-ordinated Time)
VHF - 초단파(Very High Frequency)
시각: 이 보고서에서 사용한 모든 시각은 별도로 명시하지 않는 한 UTC+1이다.
해양사고 수석조사관의 머리말
버키(Buckie)를 기지로 하는 트윈 리그 선미 트롤선 "Audacious"호와 브릭섬(Brixham)을 기지로 하는 빔 트롤선 "Chloe T"호는 각각 2012년 8월과 9월에 침수되어 침몰하였다. 다행히 두 선박의 선원 모두 시련에서 살아남았고, 두 선박이 모두 멸실되었음에도 MAIB 조사관들은 사고의 원인과 상황을 포괄적으로 이해할 수 있었다. 이 조사들의 결과는 하나의 보고서로 합쳐졌다.
MAIB 조사 중에 확인된 안전 쟁점들은 놀라울 정도로 비슷하다. 두 선박의 기관실은 모두 급속히 침수되었고 빌지 펌프는 유입되는 물을 감당하지 못하였다. 두 사고 모두 선박의 해수 냉각 계통 파손이 원인이었을 가능성이 높다. 선원들은 해수 흡입 밸브가 금세 침수되어 물에 잠겼기 때문에 이를 닫을 수 없었다. Audacious호에서는 빌지 경보가 작동하였으나 한동안 조타실에 사람이 없어서 초기에 감지되지 못하였다. Chloe T호에서는 선박에 설치된 빌지 경보가 작동하지 않았을 가능성이 높다.
어선의 구조적 건전성과 안전한 운항, 그리고 선원의 안전을 보장할 책임은 전적으로 선주에게 있다. 그러나 영국 해사연안경비청(MCA)의 점검 및 검사 체계는 선주들이 자신의 안전 책임을 이행하고 있는지 확인하기 위한 적절한 수준의 감독과 감시를 제공하려는 것이다. 두 조사는 해수 배관 계통의 시험과 점검과 같은 중요한 사안과 관련하여 MCA 검사원에게 제공되는 지침이 개선되어야 한다는 결론에 이른다. 더욱 우려되는 것은, 두 조사에서 MCA 검사원이 사용하는 기록 관리 및 관리 체계도 상당한 개선이 필요하다는 점이 확인되었다는 것이다. 두 사례 모두에서 중간 점검의 누락과 갱신 검사 절차의 지연이 확인되었으며, 어느 선박도 MCA가 검사원에게 내린 지침이 의도한 수준의 감독을 받았을 것으로 보기 어렵다. 2005년 8월 어선 Harvest Hope호1 침몰 이후 MAIB가 이와 유사한 지적을 하였다는 점은 실망스럽다. 당시 MCA는 확인된 미비점에 대해 내부 조사를 실시하겠다고 약속하였으나, 그럼에도 이러한 약점이 7년 이상 지난 지금까지도 남아 있는 것으로 보인다.
따라서 어선의 검사와 점검의 범위, 일정, 적용 및 기록 관리를 개선하려는 취지의 권고가 MCA에 제시되었다. MCA 검사원이 효과적인 관리 지원 도구를 제공받고, 충분히 숙고된 검사 및 점검 절차를 일관되게 적용하는 것은 우리 어선단의 안전에 중요할 뿐만 아니라, 어업계 이해관계자들 사이에서 MCA의 권위를 유지하기 위한 전제 조건이기도 하다.
Steve Clinch해양사고 수석조사관1 MAIB 보고서 21/2006
어선 AUDACIOUS호의 침수 및 침몰 - 요약
2012년 8월 10일, 23.7m 트윈 리그 선미 트롤선 Audacious호는 애버딘 동쪽 45마일 해상에서 잔잔한 기상 조건 속에 조업하던 중 기관실이 침수되었다. 선원들은 물의 유입을 막지 못하고 선박이 1554시에 침몰하기 직전에 퇴선하였다.
선장은 유일한 선교 당직자로서 조리실에 있다가 선박 기관의 음색이 바뀌는 것을 듣고 조타실로 돌아왔고 기관실 빌지 경보가 작동한 것을 발견하였다. 기관실에 물이 들어와 주기관 상단 높이까지 차 있음이 확인되었다. 빌지 펌프가 가동되었으나 해수 흡입 밸브는 물속에 있어 닫을 수 없었으며, 선원들은 물의 유입을 막기 위해 할 수 있는 일이 없음이 분명하다는 것을 알았다. 선장은 "Mayday" 조난 메시지를 방송하고 선박의 비상위치지시용 무선표지를 작동시켰다. 선원들은 선박이 침몰하기 몇 분 전에 구명뗏목으로 퇴선하였고, 이후 "Mayday"에 응답한 선박에 의해 무사히 구조되었다.
이 사고에 대한 MAIB 조사에서는 침수가 아마도 기관실 해수 흡입 배관의 파손 때문이었으며, 사고 이전에 조타실에 사람이 없던 시간이 있었음이 밝혀졌다. 또한 법정 검사와 점검이 선박의 영국 어선 증서 조건에 따라 실시되지 않았음이 밝혀졌다. 선교 당직 기준에 관하여 선주에게 권고가 제시되었다.
PARTICULARS
of departure Lerwick, Scotland Intended
Port
of arrival Fraserburgh, Scotland Type of
voyage
Commercial
fishing
Cargo information Fish
6
INFORMATION Date and time 10 August 2012, 1554 Type of
marine casualty
or incident Very Serious
Marine Casualty
Location of incident 45nm east of Aberdeen, Scotland Place on board Complete vessel Injuries/fatalities Nil Damage/environmental impact Vessel lost Ship operation
Persons on board 6
1.2 BACkGROUND Audacious, a twin rig
stern
trawler
was purchased by her current owner in 2007. The vessel, originally named Endurance, was built in 1999 to Seafish1
construction
standards by Astilleros Armon, Navia, Spain. The
(
MCA
) issued the vessel with its first UK
Certificate (
) in May 1999. 1 Seafish - The
, a non-Departmental Public Body which works with the UK seafood industry to promote good quality and sustainable seafood, and to improve the safety and standards of training for fishermen. Fishermen are required to complete training in,
sea
survival,
-fighting, first aid and safety awareness. Audacious Image courtesy of
Trawler
Photos
In May 2008 a replacement
was installed in the vessel and in August 2008 an
fire
resulted in the vessel being out of service for several months. The most recent
UKFVC
was issued by the
MCA
in December 2008; it was due to expire in December 2013. The owner employed two crews, which enabled the vessel to remain at
sea
for the majority of the year. The vessel had been used to fish in northern Scottish waters for several weeks prior to the accident. 1.3 NARRATIVE 1.3.1 Events prior to the accident On 29 July 2012 Audacious arrived in Ullapool, Scotland to land her catch. While in
port
the vessel’s engineer replaced a 50mm diameter gearbox cooling pipe which, due to difficulty of access, had to be welded in-situ. Audacious departed Ullapool at 0300 on 31 July to resume
fishing
; the catch was subsequently landed in Lerwick, Shetland Islands, on 5 August. After sailing from Lerwick, the
fished the vessel to the east of the Shetland Islands until 9 August. The
then decided to reposition the vessel to fish the Aberdeen Bank, where she arrived at 0600 on 10 August 2012. The
skipper
knew the seabed in the area was very weedy and chose to fish with a single
; the
port
trawl net
was shot away at 0630. The engineer was the sole
from 0700 until he was relieved by the
skipper
just before the net was hauled at 1130. When the net was recovered it was found to have been badly torn and the
was transferred to the
net for the next
trawl
, which began at 1230. At about 1300, after cleaning and stowing the catch of fish, the damaged net was spread out over the upper and main decks and the
crew
began to make repairs (Figure 1). The
skipper
was the sole
bridge watchkeeper
; at the same time he oversaw the four crewmen who were mending the net. The engineer washed down and cleaned the fish processing
throughout this period. At 1430 the
skipper
disengaged the auto-
trawl
setting on the
trawl
winch to allow the repairs on the
port
net to be completed. At about 1445 the engineer completed cleaning the fish processing area and went to the
, where he stopped the
which had been set to drain the
. He then spent a few minutes checking the
engine room
and confirmed that the
bilge
was dry before leaving the space and going to the
. At 1450 the
skipper
engaged the auto-
trawl
function and went to the
galley
, where he informed the engineer that the
trawl
would be hauled at about 1730. The engineer then went to his
to rest and the
skipper
, who was still the sole
bridge watchkeeper
, turned on the
galley
cooker and made his way back to the wheelhouse via the main
deck
to check on progress with the net repairs.
Figure 1: Torn net spread over the upper and main decks (taken on an earlier
fishing
trip) Images courtesy of Caledonia TV
1.3.2
Engine room
At 1514 the
skipper
was in the wheelhouse and he used his mobile telephone to send a text message to the
skipper
of another vessel. He returned to the
galley
, two decks below the wheelhouse, and was preparing a meal for the
crew
when, at about 1520, he heard the tone of the vessel’s
main engine
change. The
skipper
returned to the wheelhouse and saw lit warning lamps on the
main engine
display panel; he noted that the
engine room
bilge
alarm lamp was also illuminated. The
, which had been at its normal setting of 60%
while
trawling
, then moved to 30%
without any user input. The
skipper
attempted to adjust the
and stop the
engine
, both without success. He then called the engineer, using the vessel’s intercom, and advised him that he had lost control of the
engine
. The vessel began to make
, and the
skipper
noted that its
had reached 2 knots
astern
when he left the wheelhouse to make sure that the engineer was dealing with the problem. The engineer entered the
engine room
at about 1525 to investigate. He saw that water had entered the
and was almost level with the top of the
main engine
(Figure 2). He immediately started a
bilge pump
, rated at 25 tonnes per hour, to
out floodwater from the
compartment
. Water began to spray from the
onto the
and intercooler; the resultant steam began to fill the
and the
main engine
stopped. The auxiliary engines (Figure 3), which provided power to the
bilge pump
, were still above the water level and continued to operate. The engineer advised the
skipper
, via the intercom, that the water in the
engine room
was
flooding
in faster than the
bilge pump
could
pump
it out. Figure 2:
Engine room
Main engine
- looking on to
port
side
Main engine
- looking on to
starboard
side
The
engine room
smoke alarm activated and the
skipper
, who needed to confirm the situation in the
engine room
, sent a crewman to investigate. The crewman went to the
engine room
via the main
deck
alleyway (Figure 4), which was beginning to fill with steam and smoke. He opened the
engine room
door, observed that the space was full of steam and smoke and then closed the door and returned to the wheelhouse. To gain a better understanding of the situation, the
skipper
decided to proceed to the
engine room
himself, via the internal
accommodation
. As the
skipper
opened the
engine room
door he met the engineer emerging through steam and smoke. The engineer told the
skipper
that the
flooding
was out of control and that they should evacuate immediately. The
skipper
asked if the
sea
inlet valves had been closed, and was advised that they were still open as they were more than a metre under water and were inaccessible. Figure 3:
Engine room
showing auxiliary engines Figure 4:
Accommodation
alleyway Image courtesy of Caledonia TV
The
skipper
, engineer and crewman returned to the wheelhouse; the remaining three
crew
members were still mending the net on the main
deck
and were not aware of the situation in the
engine room
. 1.3.3
and rescue The
skipper
instructed the crewman to tell the other
crew
members to collect
from their cabins and prepare the vessel’s two liferafts for abandoning ship. At 1530 the
skipper
broadcast a “Mayday” message using a
(
VHF
) radio set, powered by the vessel’s emergency batteries.
at Aberdeen
(
MRCC
) replied immediately, asked the
skipper
for the vessel’s
and number of persons on board, and relayed the distress message to all vessels in the area. Several vessels responded, including the
Ocean Observer, which was 12 nautical miles from Audacious, and proceeded towards the
fishing vessel
to assist. The
crew
on board Audacious mustered in the wheelhouse. They had collected personal effects from their cabins but not their
lifejackets
or survival suits, which were also stowed in the
accommodation
. The
skipper
, who was wearing a flotation jacket, instructed the
crew
to
the liferafts and
abandon ship
. He then collected and activated the vessel’s
(
EPIRB
), the first transmission from which was recorded by the
coastguard
at 1539. The
skipper
made a further
VHF
radio
at 1541 to advise the
coastguard
that the
crew
were abandoning into a
. The
crew
launched both liferafts, but the painter of the
port
liferaft
was inadvertently released during the
launch
process and the raft drifted away from the vessel before it could be secured. The remaining
liferaft
was made fast to the
starboard
hull ladder (Figure 5), from where the
crew
boarded it. Figure 5:
Starboard
side hull ladder Hull ladder Image courtesy of Caledonia TV
The
skipper
remained on the
and, at about 1542, he looked down the
engine room
emergency escape trunk and noted that the water level in the
engine room
had covered the lower two rungs of the escape ladder. At about 1545 the
skipper
passed the
EPIRB
and several
trawl
sensors into the
liferaft
and then joined the rest of the
crew
in the
liferaft
. The painter was cut and the
liferaft
drifted away from the vessel; the
crew
photographed Audacious as she settled in the water (Figure 6) until she
at 1554. At 1645 Ocean Observer arrived at the scene, her
crew
launched their
and recovered Audacious’s
crew
from the
liferaft
. Both liferafts,
fishing gear
and other flotsam, which had floated free from Audacious as she
sank
, were also subsequently recovered by the
crew
of Ocean Observer. Figure 6: Audacious
sinking
sequence
At 1730 a
helicopter, which had been mobilised by the
coastguard
, arrived at the scene. The
crew
of Audacious were lifted from the
deck
of Ocean Observer into the helicopter and were subsequently landed ashore, unharmed, in Aberdeen. The vessel was not salvaged and no underwater surveys were conducted due to the remote location of the
. 1.4 ENVIRONMENTAL CONDITIONS Wind: Lights airs
Sea
State: Slight
Visibility
: Good 1.5
CREw
There were six crewmen on board Audacious at the time of the accident: The
skipper
was 26 years old, had been a fisherman for 10 years and had been in charge of Audacious for 5 years. He achieved a
(
Fishing Vessel
) Class 1
(
CoC
) in 2007. He had attended the mandatory Seafish safety training courses:
sea
survival,
fire
fighting, first-aid and health & safety, in 2002, and a safety awareness
in 2006. The engineer was 57 years old and held an Engineer
Officer
(
Fishing Vessel
) Class 1
CoC
. He was an experienced fisherman, had worked for the owner of Audacious for 16 years and had been engineer on the vessel since 2007. He had also worked as a marine engineer with a Scottish shipyard for 15 years. He had not attended the Seafish safety awareness
course
. Of the four remaining
crew
, one was a UK national who had attended a
sea
survival training
course
in 1989 and had been on Audacious for 18 months. The other three crewmen were Filipino nationals who had been with the vessel for 3 years, 7 months and 5 months respectively and had completed safety training in the Philippines. They had not completed the mandatory Seafish safety awareness training
course
before commencing work on board Audacious. 1.6 GENERAL DESCRIPTION OF VESSEL The vessel was a
steel
twin rig
trawler
with a deep
bilge
, bulbous forefoot and transom
stern
, incorporating a full length working area at
upper deck
level (Figure 7). Two
hatches were fitted in the transom which gave access to a full length twin
trawl
, the two
trawl
line winches (
port
and
starboard
) and the sweep line winch, forward. The wheelhouse was fitted with a full width console forward which incorporated the electronic
fishing
and navigational aids (Figure 8). The winch controls and auto-
trawl
system were located at the aft end of the wheelhouse, overlooking the
stern
area.
Figure 7:
Upper deck
showing full length working area (taken on an earlier
fishing
trip) Images courtesy of Caledonia TV
1.6.1
Engine room
The
engine room
and
fish hold
were located below the main
deck
, the steering flat/ workshop were accessed via a
door in the aft
engine room
, which was routinely left open. Audacious was fitted with a Caterpillar 3516
main engine
, which developed 1200kW at 1200rpm,
a four bladed variable
pitch
inside an Armon nozzle, through a Volda gearbox. The vessel was capable of a top
speed
of 12.2 knots. Two Volvo Penta auxiliary engines developing 210kW at 1500rpm were installed in the
engine room
on top of the
tanks (Figure 3). The
fresh water
tanks formed a ‘well’ around the
main engine
. 1.6.2 Seawater
The pipework for the seawater
cooling system
consisted of 150mm diameter galvanised
steel
pipe connected to two cast iron bronze
screw
-down
sea
inlet valves in cast iron
sea
chests. These were located at the forward end of the
engine room
, to
port
and
starboard
of the
engine
in the well formed by the
fresh water
tanks. The cooling pipes for the
main engine
were 100mm in diameter and for the auxiliary engines were 50mm in diameter which were connected to the main seawater intake pipe. The two seawater valves were the only valves in the
engine room
that were beneath the
. Figure 8: Wheelhouse – view at forward console Image courtesy of Caledonia TV
1.6.3
Bilge
pumping system The
bilge
pumping system in the
engine room
consisted of 65mm pipework connected through two, electrically-operated general service pumps, each rated at 25m3/hour. A third
, rated at 30m3/hour, was located in the main
deck
fish handling area. 1.6.4
Bilge
alarms Audacious was fitted with two
bilge
alarms in the
engine room
, each activated by float switch sensors. The alarms were connected to an audible/visual alarm panel in the wheelhouse and to a flashing beacon in the
engine room
. A general alarm was fitted in the
crew
mess which was designed to activate if the wheelhouse alarm went unanswered. The flashing beacon was operating when the engineer entered the
engine room
, and the wheelhouse
bilge
alarm had activated when the
skipper
returned to the wheelhouse. There was no evidence that the alarm in the
crew
mess had activated. 1.7
AND
FLOODING
RATE INVESTIGATION The
commissioned Marine Data International (MDI) to determine the
stability
condition of Audacious at the time of the accident (Annex A). MDI reported that, once the floodwater in the
engine room
rose above the top of the
engine
and the
fresh water
tanks (Annex B) located on either side of the
engine
, there was a very large increase in
moment (FSM); “The FSM increased from about 45.13 tonnes metres (tm) to 229.17tm once above the
engine
which took the vessel from a stable (albeit
sinking
) condition to an unstable condition”. MDI was able to calculate from the reported floodwater levels that about 32t of water would have entered the
engine room
when the engineer first saw it at 1525. A further 40t would have entered the
compartment
by the time the
skipper
looked down the escape shaft at 1542. 1.8 REGULATORY REqUIREMENTS 1.8.1 Statutory framework The UK government’s maritime regulator, the
MCA
, issues statutory certification relating to the
construction
and maintenance of
fishing
vessels. This covers the general areas of the hull,
machinery
and safety equipment (including
and radio equipment).
MCA
staff conduct the majority of surveys of
fishing
vessels under 24m length; the survey of hull and
machinery
is not normally delegated to Recognised Organisations or Certifying Authorities as is frequently the case for merchant and small commercial vessels. The statutory requirements for
fishing
vessels such as Audacious are set out in the
MCA
’s
(
MSN
) 1770, titled, ‘The
Fishing
Vessels Code of Safe Working Practice for the
Construction
and Use of 15 metre
length overall
(
LOA
) to less than 24 metre
registered length
(RL)
Fishing
Vessels’, referred to hereafter as the 15-24m Code. The 15-24m Code is a successor to the
Fishing
Vessels (Safety
Provisions) Rules 1975 (hereafter referred to as the 1975 Rules). The 15-24m Code is given statutory force by The
Fishing
Vessels (Safety of 15-24 Metre Vessels) Regulations 2002 (SI 2002:2201) which entered into force in November 2002. 1.8.2 15-24m Code The 15-24m Code requires that vessels be surveyed ‘in order to verify that the vessel complies with the requirements of the Code and such regulations as may apply to it. The
may require the vessel and any of its
machinery
, fittings, equipment or arrangements to be submitted to such tests and examinations as are considered necessary to demonstrate compliance with the requirements of the Code.’ The 15-24m Code states that it is the owner’s responsibility to present his vessel for survey and inspection. Every
fishing vessel
that is subject to the 15-24m Code should be surveyed and inspected as follows: • An
during, and on completion of
construction
, or on
to the UK register prior to the issue of a
UKFVC
. • Surveys for the
of the
UKFVC
at intervals not exceeding 5 years. • An inspection (normally referred to as an ‘intermediate inspection’) not less than 24 months and not more than 36 months from the recorded date of the vessel’s initial or previous
renewal
survey. This is to verify that the vessel continues to comply with the requirements of the Code. • Surveys during major repairs or modifications. • Annual self-certification by the owner or a delegated representative that the vessel continues to meet the major requirements of the Code. The
UKFVC
should be endorsed by the
surveyor
after the intermediate inspection has been completed. It is permitted to extend a
UKFVC
beyond its 5-year validity for a period not exceeding 2 months in exceptional circumstances. Interim, or short term UKFVCs may also be issued if necessary. The owner is also required to ensure that the
crew
’s training and certification are valid. 1.8.3 Technical requirements The 15-24m Code covers a broad scope, including most aspects of the vessel’s
construction
and operation. Inlets and discharges The 1975 Rules stated that
sea
inlets and discharges in
machinery
spaces ‘shall be readily accessible and be provided with indicators showing whether the valves are open or closed’.
The 15-24m Code builds on this and requires that if inlet and
overboard valves are not fitted above the level of the floor plates, a rapid and practical means should be provided to allow for the
to be operated from the floor plate level. Arrangements on vessels pre-dating the introduction of the Code are accepted provided that ‘the valves fitted at hull penetrations remain both accessible and efficient in service’.
and other seawater systems Seawater piping should be of aluminium bronze, cupro-nickel or similar corrosion resistant material. Galvanic corrosion between dissimilar metals should be prevented by the use of isolation
, washers and sleeves between the flanges and fasteners joining pipes.
Bilge
alarms The 1975 Rules required that unmanned
machinery
spaces be provided with ‘warning devices’ which indicate the leakage of water into the
compartment
. This was further reinforced in the 15-24m Code, which states that
bilge
alarm sensors should be fitted in the ‘propulsion
machinery space
and
fish hold
of the vessel’. The
bilge
alarm should provide an audible and visual warning at the control
position
. In addition, the Code states that
engine room
bilge
alarm systems should be provided with a secondary, independent
bilge
alarm system, or a fail-safe warning that shows if the
bilge
alarm circuit becomes faulty. 1.9 REqUIREMENTS AND GUIDANCE FOR THE CONDUCT OF STATUTORY SURVEYS AND INSPECTIONS While the 15-24m Code lists the technical requirements that a vessel must meet, there is no guidance on how the survey or inspection should be conducted. This is provided elsewhere. 1.9.1 Guidance to surveyors Survey and Certification Policy (
23) Chapter 2 of the
MCA
’s guidance to surveyors on Survey and Certification Policy (Marine Survey Instructions to Surveyors -
MSIS
23) relates to the
UKFVC
. The guidance states that the purpose of the survey is to ‘ensure that the hull structure, main and auxiliary
machinery
boilers and other pressure vessels, the electrical system, … are in compliance with the code of practice and are in all respects, satisfactory.
MSIS
23 also provides guidance on the specific items to be considered to help prevent
flooding
incidents. Most relevant is the advice in part 8.2.6.2 regarding ship side valves, which states that ‘
Valve
closing devices must be in accessible positions and where valves are located below
engine
floor plate level, extended spindles (or equivalent remote closing) should be provided. Pressure testing can be useful to prove sealing arrangements. Guidance is also provided on
bilge
alarms and pipework. Regarding
bilge
alarms,
MSIS
23 states that alarms should be tested and that owners should be encouraged to fit secondary or fail-safe alarms. A significant amount of advice is provided
about surveying pipework. Surveyors are advised to use sampling techniques and record what has and has not been examined. It is emphasised that it is the owner’s responsibility to demonstrate that pipework is in a satisfactory condition. Examination techniques, such as hammer testing2, ultrasonic measurement and pressure testing are recommended. Surveyors are recommended to have representative samples in high risk areas of pipework removed for detailed inspection. Survey and Inspection of
Fishing
Vessels (
MSIS
27) The
MCA
’s guidance on the Survey and Inspection of
Fishing
Vessels (
MSIS
27) states that intermediate inspections of 15-24m
fishing
vessels are required to maintain the validity of the
UKFVC
. Any exemptions from the applicable rules (the 1975 Rules in this instance) which have previously been granted should be reviewed at each
renewal
survey with the aim of deleting them wherever possible.
MSIS
27 Section 1.9 states that a schedule for surveying hull and
machinery
items over a 5-year cycle (to a similar standard as a
classification society
would apply to a larger
merchant vessel
) should be agreed with the owner. The owner should compile a survey schedule and submit it to
MCA
surveyors for approval. Examples of typical schedules for
machinery
and hull surveys are provided in Annexes 10 and 11 respectively of
MSIS
27 and are discussed in more detail later in this section. Section 1.9.14 of
MSIS
27 states that intermediate inspections should be carried out between the second and third anniversaries of the issue of the
UKFVC
. The guidance goes on to state that the
UKFVC
is ‘rendered invalid’ if the intermediate inspection is not done, and that the vessel should be detained. It is an offence to take a
fishing vessel
to
sea
without the appropriate certificate being in force. Section 1.17 of
MSIS
27 describes how the conduct and results of
renewal
surveys are to be recorded in the
MCA
’s filing system. Form MSF 1327, attached as Annex 12 to the guidance, lists the documents which should be seen (and assessed) as part of the survey process. This includes a document titled ‘
machinery
maintenance’; however, the document itself did not need to be filed. Chapter 5 of
MSIS
27 provides detailed guidance on surveying
machinery
on
fishing
vessels. Section 5.7.6 is most relevant and states that ‘
sea
water pipes should be accessible for inspection and maintenance.’ The section goes on to state that surveyors should thoroughly check pipework strainers and isolation valves, and encourages the ‘liberal use of hammer testing’. After the first
renewal
survey (5 years) the guidance says that seawater systems should be subjected to a 3 bar pressure test – no advice is given on how this should be done. Of most relevance, however, is a requirement that seawater valves must be capable of being closed from above the floorplate level. Regarding
bilge
pumping systems, Chapter 6 of
MSIS
27 states that valves should be operable from above floor plate level and that seacocks should operate freely.
Valve
handles should not be located solely in areas which are difficult to access or where they may quickly become inaccessible in the event of rapid
flooding
. 2 ‘Hammer testing’ describes the technique of determining whether an object is ‘sound’ or has corroded. A pipe in good condition will make a clear ringing sound when struck; a dull thud indicates that the pipe has corroded.
Annex 10 of
MSIS
27, relating to
machinery
surveys, provides a detailed
of main and auxiliary
machinery
to be surveyed. The items to be surveyed which were of most relevance to this accident are listed as follows: • Seawater /
/
bilge
pipes • Main S W
(
main engine
salt to
fresh water
heat exchanger) •
Sea
Connections: suctions and discharges [sic] Annex 11 refers to the items to be considered during hull surveys; these include the thickness of
(particularly in way of inlets and outlets) and the condition of
engine room
bilges.
Fishing
Vessels Survey / Inspection Aide Mémoire (MSF 5550) The
MCA
has produced a series of aides mémoire to help remind owners and surveyors of the scope of the various
fishing vessel
codes. MSF 55503 covers the requirements of the 15-24m Code. MSF 5550 divides the requirements into those that should be considered during: • Survey or inspection • Inspection • Out of water survey. A
list
of the necessary certificates and records is also provided. MSF 5550 states that the condition of pipework, skin (hull) fittings,
sea
cocks and their ease of operation should be assessed during surveys and inspections. A reminder is given that valves should be accessible from above the floor or
deck
plates. The condition of
sea
inlets and
discharge
valves and cocks should also be checked when vessels are being surveyed out of the water.
Bilge
pumps and alarms should be checked whenever vessels are inspected. When completing MSF 5550, the form reminds surveyors to check that the
UKFVC
is valid and that the intermediate inspection has been carried out. 1.9.2 Other guidance
(
MGN
) 165 (
Fishing
) titled ‘The Risk of
Flooding
’ was published by the
MCA
in 2001. It refers to a series of investigations conducted by the
MAIB
in which uncontrollable
flooding
caused
fishing
vessels to be lost. Among several recommendations, the guidance encourages
fishing vessel
operators to: • Fit supplementary
bilge
alarms and carry additional pumps to mitigate the effects of
flooding
. 3 MSF 5550 Revision 2 dated 16/09/09 was in force at the time of the accident. The
MCA
drafted a number of updates to this and the related aides mémoire while this report was being prepared.
•
Position
seawater inlet valves where they can be easily and quickly closed – fitting extended spindles to
valve
handles where necessary to ensure that valves fitted beneath the floor plates can be shut in an emergency. • Open and close
sea
inlet valves regularly (at least monthly) to ensure that they do not seize. • Test
bilge
alarms daily. • Ensure that
crew
members are familiar with how to operate
bilge
pumping systems.
MGN
165 (F) advises that all
sea
valves should be closed in an emergency. 1.10 CERTIFICATION AND SURVEY HISTORY The vessel’s Consultative Marine (CM) files were obtained from the
MCA
and were studied together with information held in the
(
SIAS
) database to provide information on the vessel’s certification and survey history. The CM file, available specifically for the survey of
machinery
(02 suffix), had not been created. 1.10.1 Certification history Audacious’s initial
UKFVC
, issued in accordance with the 1975 Rules, was valid until 1 May 2003. The vessel was first surveyed under the 15-24m Code on 27 March 2003. A short term
UKFVC
was issued on 5 August 2003 valid until 31 October 2003. A copy of a fax sent from the
MCA
surveyor
to the owner’s representative dated 14 October 2003 referred to an
having been conducted on 27 June 2003. The fax stated that no further short term certificates would be issued until a programme to resolve concerns over the vessel’s
stability
, and completion of a
stability
book, had been agreed. There was no specific evidence in the CM file to show that such a programme was agreed, but a further short term
UKFVC
was issued on 30 October 2003, based on the previous survey completed on 27 March 2003. It was valid until 31 December 2003. A third short term
UKFVC
was issued on 17 December 2003, again based on the survey completed on 27 March 2003. It was valid until 31 March 2004. The first full term
UKFVC
under the 15-24m Code was issued on 29 April 2004. This certificate was based on the survey completed on 27 March 2003 and was valid until 31 December 2008, 5 years and 9 months after the survey had been completed. The
UKFVC
states that an intermediate inspection should be completed between 31 December 2005 and 31 December 2006. There was no record to show that this took place. The vessel’s most recent
UKFVC
(Annex C) was issued on 10 December 2008 and was valid until 31 December 2013. It was based on a survey carried out on 14 August 2008.
The continued validity of the
UKFVC
was subject to the completion of annual selfcertification documentation by the owner and an intermediate inspection being carried out by the
MCA
between 31 December 2010 and 31 December 2011. There was no evidence to indicate that, by the time of the accident, the owner’s annual self-certification documentation had been completed or that the intermediate inspection had taken place. A summary of the relevant findings from Audacious’s survey history are presented in the table below: Date of Survey/Inspection Survey/Inspection details May 1999 Building survey: Astilleros Armon, Navia, Spain 18, December 2002 Radio Survey 14, January 2003 Targeted Inspection (9 deficiencies recorded) 17, March 2003 UK FVC
Renewal
Survey (18 deficiencies recorded) “
Engine Room
pipe work hammer tested” Ultrasonic inspection of hull thickness carried out 10, August 2004 Targeted Inspection (7 deficiencies) 29, October 2004 Radio Survey 10, October 2006 Targeted Inspection (2 deficiencies) 3, July 2007 (Vessel under new ownership) UK FVC
(19 deficiencies including reference to signs required on
watertight
doors to “keep closed at
sea
”) January/February 2008 FV Additional (
Renewal
) survey (20 deficiencies including reference to signs required on
watertight
doors to “keep closed at
sea
” ) Survey undertaken following
engine
removal after catastrophic failure Ultrasonic inspection of hull,
engine room
bulkhead
and slush well thickness carried out. 1, August 2008 Radio Survey 14, August 2008 Survey undertaken following
engine
fire
20, July 2011 UK
Exemption inspection carried out (for carriage of film
crew
) (n.b.
surveyor
’s written comment: “Reminder-Interim inspection due by 31/12/11”) Table 1: Summary of relevant findings from Audacious’s survey history
1.10.2 Hull thickness measurements Ultrasonic thickness measurements of the hull were undertaken in March 2003 and February 2008. In the lower part of the
engine room
the measurements showed an average thickness of 12mm in 2003 and 10mm in 2008. 1.11 MAINTENANCE HISTORY There was documentary evidence that Audacious had received regular maintenance throughout her life. Annual refits had been completed when
sea
inlet valves and suctions were cleaned of marine growth and fabric maintenance was undertaken as and when required. Records showed that work to replace various sections of pipework in the vessel’s
engine room
had been carried out over several years by a reputable Scottish shipyard. The size of the pipework replaced was between 25 and 100mm in diameter, there was no record that any work had been carried out, at any time, on the 150mm
main engine
seawater cooling pipe. 1.12 kEEPING A SAFE
ON
FISHING
VESSELS In 2006 the
MCA
issued
MGN
313 (F)4 following a number of vessel losses, to highlight the importance of keeping a safe
navigational watch
on
fishing
vessels. This
MGN
states that the wheelhouse must not be left unattended at any time. In relation to
navigation
,
MGN
313 (F) states that the person in charge of the
navigational watch
should keep watch in the wheelhouse and not undertake any other duties that would interfere with the safe
navigation
of the vessel. Rule 5 of the COLREGS5 requires that every vessel shall at all times maintain a proper and effective
. 1.13
FISHING
VESSELS:
CREw
CERTIFICATION, TRAINING AND DRILLS The
Fishing
Vessels (Safety Training) Regulations 1989 (as amended) state that: “no experienced fisherman shall act as
of a
fishing vessel
or be employed or engaged on a
fishing vessel
unless he is the holder of a certificate or certificates certifying that he has undergone an Approved Training
Course
in Safety Awareness”. The duty to comply with these regulations rests with the owner and
skipper
of a
fishing vessel
, as well as with the fisherman himself. The 15-24m Code (Section 8.1.2.1) requires skippers to ensure that the
crew
of
fishing
vessels are trained in the use of all lifesaving appliances carried on board. Such training should be carried out in drills, at intervals of not more than 1 month. 4
MGN
313 (F): http://www.dft.gov.uk/
mca
/313_a.pdf 5
=
, 1972 (as amended)
1.13.1 Training and certification requirements for the
crew
of
fishing
vessels
MGN
411 6, issued by the
MCA
in March 2010, states (2.3.4) that, in relation to the Safety Awareness Training
course
: “Any fishermen [sic] coming from outside the UK must, regardless of whether he has undertaken the Merchant Navy STCW7 basic safety training, undertake this
Course
before commencing work for the first time on a UK Registered
fishing vessel
. Any fisherman with two years experience must also undertake the Safety Awareness and
Course
”. 1.13.2
Fishing
vessels: Checks on
crew
certification and drills
MGN
4308 was issued by the
MCA
in January 2011 and provides guidance to owners, skippers and crews regarding the checks that
MCA
surveyors will make to ensure that the
crew
have undertaken approved safety training courses. 1.13.3 Safety Awareness (Managing Safety at
Sea
)
course
The syllabus for the Safety Awareness
course
, specified by Seafish, includes the legal principles and risk control measures for the management of safety on board
fishing
vessels. The
course
emphasises the importance of crews undertaking drills and musters, and of wearing the correct
in emergency situations. 6
MGN
411 http://www.dft.gov.uk/
mca
/
mgn
_411.pdf 7
= Seafarers Training Certification and
8
MGN
430 (F) http://www.dft.gov.uk/
mca
/
mgn
_430.pdf
한국어 번역 · 모델 · 검수 전
1절 사실 정보
1.1 AUDACIOUS호와 사고의 세부 사항
선박 세부 사항 선박명 Audacious 기국 영국 선급 해당 없음 어선 번호 BF 83 선종 트윈 리그 선미 트롤선 등록 선주 Deveron Fishing Company, 버키(Buckie) 관리 회사 Deveron Fishing Company, 버키 건조 강재, 1999년 스페인 나비아(Navia)에서 건조 전장 27.60m 등록 길이 23.95m 총톤수 437 최소 안전 승무정원 해당 없음 허가된 화물 없음
항해 세부 사항 출항항 스코틀랜드 러윅(Lerwick) 도착 예정항 스코틀랜드 프레이저버러(Fraserburgh) 항해 유형 상업 어로 화물 정보 어류 승무원 6 해양사고 정보 일시 2012년 8월 10일 1554시 해양사고 또는 사건 유형 매우 심각한 해양사고 사고 장소 스코틀랜드 애버딘 동쪽 45nm 선내 장소 선박 전체 부상자/사망자 없음 손상/환경 영향 선박 멸실 선박 운용 트롤 조업 항해 구간 항해 중 환경 주간, 실바람, 잔잔한 바다, 양호한 시정 승선 인원 6
1.2 배경
트윈 리그 선미 트롤선 Audacious호는 2007년에 현 선주가 매입하였다. 이 선박은 원래 이름이 Endurance호였으며, 1999년 스페인 나비아의 Astilleros Armon에서 Seafish1 건조 기준에 따라 건조되었다. 영국 해사연안경비청(MCA)은 1999년 5월에 이 선박에 최초의 영국 어선 증서(UKFVC)를 발급하였다.
1 Seafish - 영국 수산산업청(Sea Fish Industry Authority). 영국 수산물 업계와 협력하여 양질의 지속 가능한 수산물을 촉진하고 어민의 안전과 훈련 기준을 개선하는 비부처 공공기관이다. 어민은 해상 생존, 소화, 응급 처치 및 안전 인식에 관한 훈련을 이수하여야 한다.
Audacious호 사진 제공: Trawler Photos 2008년 5월에 이 선박에 교체용 주기관이 설치되었고, 2008년 8월에는 기관 화재로 인해 선박이 몇 달 동안 운항을 하지 못하였다. 가장 최근의 UKFVC는 2008년 12월에 MCA가 발급하였으며 2013년 12월에 만료될 예정이었다. 선주는 두 개의 선원 조를 고용하여 선박이 연중 대부분 바다에 머물 수 있게 하였다. 선박은 사고 이전 몇 주 동안 스코틀랜드 북부 해역에서 조업하는 데 사용되고 있었다.
1.3 경위
1.3.1 사고 이전의 사건
2012년 7월 29일 Audacious호는 어획물을 양륙하기 위해 스코틀랜드 얼러풀(Ullapool)에 입항하였다. 입항 중에 선박의 기관사는 직경 50mm의 기어박스 냉각 배관을 교체하였는데, 접근이 어려워 현장에서 용접해야 하였다. Audacious호는 조업을 재개하기 위해 7월 31일 0300시에 얼러풀을 출항하였으며, 어획물은 이후 8월 5일 셰틀랜드 제도(Shetland Islands)의 러윅에서 양륙되었다. 러윅에서 출항한 뒤 선원들은 8월 9일까지 셰틀랜드 제도 동쪽에서 조업하였다. 이후 선장은 애버딘 뱅크(Aberdeen Bank)에서 조업하기 위해 선박의 위치를 옮기기로 결정하였고, 선박은 2012년 8월 10일 0600시에 그곳에 도착하였다. 선장은 그 해역의 해저에 해초가 매우 많다는 것을 알고 있었으므로 트롤 그물 하나만 사용하여 조업하기로 하였고, 좌현 트롤 그물은 0630시에 투하되었다. 기관사는 0700시부터 1130시 직전에 그물을 끌어올리기 전 선장과 교대할 때까지 유일한 선교 당직자였다. 그물을 회수하였을 때 심하게 찢어져 있음이 발견되었고, 어구는 다음 트롤을 위해 우현 그물로 옮겨졌으며 그 트롤은 1230시에 시작되었다. 1300시경 어획물 세척과 적재를 마친 뒤 손상된 그물이 상갑판과 주갑판에 펼쳐졌고 선원들은 수리를 시작하였다(그림 1). 선장은 유일한 선교 당직자였으며, 동시에 그물을 수선하는 선원 4명을 감독하였다. 기관사는 이 시간 내내 어류 처리 갑판을 씻고 청소하였다.
1430시에 선장은 좌현 그물 수리를 마칠 수 있도록 트롤 윈치의 자동 트롤 설정을 해제하였다. 1445시경 기관사는 어류 처리 구역 청소를 마치고 기관실로 가서, 어창 빌지를 배수하도록 설정되어 있던 빌지 펌프를 정지시켰다. 그리고 몇 분 동안 기관실을 점검하여 빌지가 말라 있음을 확인한 뒤 그 구역을 떠나 조리실로 갔다. 1450시에 선장은 자동 트롤 기능을 작동시키고 조리실로 가서 기관사에게 1730시경 트롤을 끌어올릴 것이라고 알렸다. 그 후 기관사는 쉬기 위해 선실로 갔고, 여전히 유일한 선교 당직자였던 선장은 조리실 조리기를 켠 뒤 그물 수리 진행 상황을 확인하기 위해 주갑판을 거쳐 조타실로 돌아갔다.
그림 1: 상갑판과 주갑판에 펼쳐진 찢어진 그물(이전 조업 항해 중 촬영) 사진 제공: Caledonia TV원본 PDF 15쪽제3자 저작물 · 내부 열람용courtesy of Caledonia TV
1.3.2 기관실 침수
1514시에 선장은 조타실에서 휴대전화로 다른 선박의 선장에게 문자 메시지를 보냈다. 그는 조타실 아래 두 층에 있는 조리실로 돌아와 선원들의 식사를 준비하고 있었는데, 1520시경 선박 주기관의 음색이 바뀌는 것을 들었다. 선장은 조타실로 돌아와 주기관 표시 패널에 경고등이 켜진 것을 보았고, 기관실 빌지 경보등도 켜져 있음을 확인하였다. 트롤 조업 중 정상 설정인 전진 60%에 있던 프로펠러 피치가 그 후 조작 입력 없이 후진 30%로 이동하였다. 선장은 피치를 조정하고 기관을 정지시키려 하였으나 둘 다 성공하지 못하였다. 그는 선박 인터컴으로 기관사를 호출하여 기관 통제를 상실하였다고 알렸다. 선박은 후진하기 시작하였고, 선장은 기관사가 문제를 처리하고 있는지 확인하려고 조타실을 떠날 때 속력이 후진 2노트에 이르렀음을 확인하였다.
기관사는 1525시경 기관실에 들어가 상황을 조사하였다. 그는 구역 안에 물이 들어와 주기관 상단과 거의 같은 높이에 이른 것을 보았다(그림 2). 그는 즉시 시간당 25톤 용량의 빌지 펌프를 가동하여 구역의 침수된 물을 배출하려 하였다. 플라이휠에서 터보차저와 인터쿨러로 물이 튀기 시작하였고, 이로 인한 증기가 기관 구역에 차기 시작하였으며 주기관이 정지하였다. 빌지 펌프에 동력을 공급하던 보조 기관(그림 3)은 아직 수위 위에 있었으므로 계속 작동하였다. 기관사는 인터컴으로 선장에게 기관실로 들어오는 물이 빌지 펌프가 배출할 수 있는 속도보다 빠르다고 알렸다.
그림 2: 기관실 주기관 - 좌현 쪽을 본 모습 주기관 - 우현 쪽을 본 모습원본 PDF 16쪽
기관실 연기 경보가 작동하였고, 기관실 상황을 확인해야 했던 선장은 선원 한 명을 보내 조사하게 하였다. 그 선원은 증기와 연기가 차기 시작하던 주갑판 거주구역 통로(그림 4)를 거쳐 기관실로 갔다. 그는 기관실 문을 열고 구역이 증기와 연기로 가득 차 있음을 보고 문을 닫은 뒤 조타실로 돌아왔다. 상황을 더 잘 파악하기 위해 선장은 내부 거주구역을 거쳐 직접 기관실로 가기로 하였다. 선장이 기관실 문을 열었을 때 증기와 연기를 뚫고 나오는 기관사를 만났다. 기관사는 선장에게 침수가 통제 불능 상태이니 즉시 대피해야 한다고 말하였다. 선장이 해수 흡입 밸브를 닫았느냐고 묻자, 밸브가 1미터 이상 물속에 있어 접근할 수 없어서 아직 열려 있다는 답을 들었다.
그림 3: 보조 기관이 보이는 기관실 그림 4: 거주구역 통로 사진 제공: Caledonia TV원본 PDF 17쪽
선장, 기관사, 선원은 조타실로 돌아왔다. 나머지 선원 세 명은 여전히 주갑판에서 그물을 수선하고 있었고 기관실 상황을 알지 못하였다.
1.3.3 퇴선과 구조
선장은 선원에게 다른 선원들에게 선실에서 구명조끼를 가져오고 퇴선에 대비하여 선박의 구명뗏목 두 개를 준비하라고 전하게 하였다. 1530시에 선장은 선박의 비상 배터리로 동력을 공급받는 초단파(VHF) 무선기로 "Mayday" 메시지를 방송하였다. 애버딘 해상구조조정본부(MRCC)의 해안경비대 관제관들이 즉시 응답하여 선장에게 선박의 위치와 승선 인원을 묻고 조난 메시지를 해역 내 모든 선박에 중계하였다. Audacious호에서 12해리 거리에 있던 상선 Ocean Observer호를 포함하여 여러 선박이 응답하였고, 어선을 돕기 위해 그 쪽으로 향하였다.
Audacious호의 선원들은 조타실에 집합하였다. 그들은 선실에서 개인 소지품은 챙겼으나, 마찬가지로 거주구역에 보관되어 있던 구명조끼나 생존복(survival suit)은 챙기지 못하였다. 부력 재킷을 입고 있던 선장은 선원들에게 구명뗏목을 진수하고 퇴선하라고 지시하였다. 그런 다음 그는 선박의 비상위치지시용 무선표지(EPIRB)를 가져와 작동시켰고, 그 첫 신호는 1539시에 해안경비대에 기록되었다. 선장은 1541시에 선원들이 구명뗏목으로 퇴선 중이라고 해안경비대에 알리기 위해 VHF 무선으로 한 차례 더 호출하였다. 선원들은 구명뗏목 두 개를 모두 진수하였으나, 좌현 구명뗏목의 계류줄이 진수 과정에서 실수로 풀려 뗏목이 고정되기 전에 선박에서 떠내려갔다. 나머지 구명뗏목은 우현 선체 사다리(그림 5)에 묶였고, 선원들은 그곳에서 이에 탑승하였다.
그림 5: 우현 선체 사다리 선체 사다리 사진 제공: Caledonia TV원본 PDF 18쪽제3자 저작물 · 내부 열람용Image courtesy of Caledonia TV
선장은 상갑판에 남아 있었고, 1542시경 기관실 비상 탈출 트렁크를 내려다보며 기관실의 수위가 탈출 사다리의 아래쪽 두 단을 덮은 것을 확인하였다. 1545시경 선장은 EPIRB와 트롤 센서 몇 개를 구명뗏목에 넘겨준 뒤 나머지 선원들과 함께 구명뗏목에 탔다. 계류줄이 절단되어 구명뗏목은 선박에서 떠내려갔고, 선원들은 Audacious호가 물속으로 가라앉는 모습(그림 6)을 1554시에 침몰할 때까지 촬영하였다. 1645시에 Ocean Observer호가 현장에 도착하였고, 그 선원들은 고속구조정을 진수하여 구명뗏목에서 Audacious호 선원들을 구조하였다. Audacious호가 침몰하면서 떠올랐던 구명뗏목 두 개와 어구 및 기타 부유물도 이후 Ocean Observer호의 선원들이 회수하였다.
그림 6: Audacious호 침몰 과정원본 PDF 19쪽
1730시에 해안경비대가 출동시킨 수색구조 헬리콥터가 현장에 도착하였다. Audacious호 선원들은 Ocean Observer호 갑판에서 헬리콥터로 인양되었고, 이후 무사히 애버딘에 상륙하였다. 침몰 위치가 외딴 곳이어서 선박은 인양되지 않았고 수중 조사도 실시되지 않았다.
1.4 환경 조건
바람
실바람
해상 상태
약간 거침
시정
양호
1.5 선원
사고 당시 Audacious호에는 선원 6명이 승선하고 있었다.
선장은 26세였고 어부 경력 10년이었으며 Audacious호를 5년간 지휘하였다. 그는 2007년에 갑판 사관(어선) 1급 해기 자격증명(CoC)을 취득하였다. 그는 Seafish의 필수 안전 훈련 과정인 해상 생존, 소화, 응급 처치 및 보건·안전을 2002년에 이수하였고, 안전 인식 과정을 2006년에 이수하였다.
기관사는 57세였고 기관 사관(어선) 1급 CoC를 보유하고 있었다. 그는 경험 많은 어부였고 Audacious호의 선주 밑에서 16년간 일하였으며 2007년부터 이 선박의 기관사였다. 또한 스코틀랜드의 한 조선소에서 15년간 선박 기관사로 일하였다. 그는 Seafish 안전 인식 과정을 이수하지 않았다.
나머지 선원 네 명 중 한 명은 영국 국적자로, 1989년에 해상 생존 훈련 과정을 이수하였고 Audacious호에서 18개월간 근무하였다. 다른 세 명은 필리핀 국적자로 각각 3년, 7개월, 5개월 동안 이 선박에서 근무하였으며 필리핀에서 안전 훈련을 이수하였다. 그들은 Audacious호에서 일하기 시작하기 전에 Seafish의 필수 안전 인식 훈련 과정을 이수하지 않았다.
1.6 선박의 일반 설명
이 선박은 깊은 빌지, 구근형 선수 하부, 트랜섬 선미를 갖춘 강재 트윈 리그 트롤선이었으며, 상갑판 높이에 전 길이 작업 구역(그림 7)을 갖추고 있었다. 트랜섬에는 두 개의 어구 해치가 설치되어 있어 전 길이 트윈 트롤 궤도와 두 개의 트롤 라인 윈치(좌현 및 우현), 그리고 선수 쪽의 스윕 라인 윈치로 접근할 수 있었다. 조타실에는 전자 어로 및 항해 장비가 있는 전 폭 콘솔이 앞쪽에 설치되어 있었다(그림 8). 윈치 제어와 자동 트롤 시스템은 조타실 후미 끝에 있어 선미 구역을 내려다볼 수 있었다.
그림 7: 전 길이 작업 구역이 보이는 상갑판(이전 조업 항해 중 촬영) 사진 제공: Caledonia TV원본 PDF 21쪽제3자 저작물 · 내부 열람용courtesy of Caledonia TV
1.6.1 기관실
기관실과 어창은 주갑판 아래에 있었고, 조타기실/작업실은 후부 기관실 격벽의 수밀문을 통해 출입하였는데 이 문은 평소 열려 있었다. Audacious호에는 1200rpm에서 1200kW를 내는 Caterpillar 3516 주기관이 설치되어 있었으며, 이는 Volda 기어박스를 거쳐 Armon 노즐 안의 4엽 가변피치 프로펠러를 구동하였다. 선박의 최고 속력은 12.2노트였다. 1500rpm에서 210kW를 내는 Volvo Penta 보조 기관 두 대가 청수 탱크 위의 기관실에 설치되어 있었다(그림 3). 청수 탱크는 주기관 주위에 '웰(well)'을 형성하였다.
1.6.2 해수 냉각 계통
해수 냉각 계통의 배관은 직경 150mm의 아연도금 강관으로 이루어져 있었고, 주철 해수 상자(sea chest)에 있는 주철 청동 스크루다운식 해수 흡입 밸브 두 개에 연결되어 있었다. 이들은 청수 탱크가 이룬 웰 안, 기관 좌현과 우현의 기관실 선수 쪽 끝에 위치하였다. 주기관의 냉각 배관은 직경 100mm였고 보조 기관의 냉각 배관은 직경 50mm였으며 주 해수 흡입 배관에 연결되어 있었다. 두 해수 밸브는 기관실에서 흘수선 아래에 있는 유일한 밸브였다.
그림 8: 조타실 – 선수 쪽 콘솔 방향 시야 사진 제공: Caledonia TV원본 PDF 22쪽제3자 저작물 · 내부 열람용Image courtesy of Caledonia TV
1.6.3 빌지 배수 계통
기관실의 빌지 배수 계통은 65mm 배관으로 이루어져 있었고 각각 25m3/시간 용량의 전동식 일반 용도 펌프 두 대에 연결되어 있었다. 30m3/시간 용량의 세 번째 일반 용도 펌프는 주갑판 어류 처리 구역에 있었다.
1.6.4 빌지 경보
Audacious호의 기관실에는 각각 플로트 스위치 센서로 작동하는 빌지 경보 두 개가 설치되어 있었다. 경보는 조타실의 음향/시각 경보 패널과 기관실의 점멸 표시등에 연결되어 있었다. 조타실 경보에 응답이 없으면 작동하도록 설계된 일반 경보가 선원 식당에 설치되어 있었다. 기관사가 기관실에 들어갔을 때 점멸 표시등은 작동하고 있었고, 선장이 조타실로 돌아왔을 때 조타실 빌지 경보는 작동한 상태였다. 선원 식당의 경보가 작동하였다는 증거는 없었다.
1.7 복원성 및 침수율 조사
MAIB는 사고 당시 Audacious호의 복원성 상태를 확인하도록 Marine Data International(MDI)에 의뢰하였다(부속서 A). MDI는 기관실의 물이 기관과 기관 양쪽에 있는 청수 탱크(부속서 B) 상단 위로 올라오자 자유표면 모멘트(FSM)가 매우 크게 증가하였다고 보고하였다. "FSM은 기관 위로 올라온 뒤 약 45.13톤미터(tm)에서 229.17tm으로 증가하였고, 이로 인해 선박은 (가라앉고는 있었지만) 안정된 상태에서 불안정한 상태가 되었다."
MDI는 보고된 침수 수위로부터, 기관사가 1525시에 처음 보았을 때 약 32t의 물이 기관실에 들어와 있었을 것이라고 계산할 수 있었다. 선장이 1542시에 탈출 통로를 내려다보았을 때까지 추가로 40t이 그 구역에 들어왔을 것이다.
1.8 규제 요건
1.8.1 법정 체계
영국 정부의 해사 규제 기관인 MCA는 어선의 건조 및 유지와 관련된 법정 증서를 발급한다. 이는 선체, 기관 및 안전 설비(항해 및 무선 장비 포함)의 일반 분야를 포괄한다. MCA 직원이 24m 미만 어선 검사의 대부분을 수행하며, 상선과 소형 상업선에서 흔히 그러하듯 선체 및 기관 검사를 인정 대행기관이나 인증 기관에 위임하는 일은 보통 없다.
Audacious호와 같은 어선에 대한 법정 요건은 MCA의 상선 고시(MSN) 1770, '전장(LOA) 15미터부터 등록 길이(RL) 24미터 미만 어선의 건조 및 사용을 위한 어선 안전작업 실무규약'(이하 15-24m 규약)에 규정되어 있다. 15-24m 규약은 『1975년 어선(안전 규정) 규칙(Fishing Vessels (Safety Provisions) Rules 1975)』(이하 1975년 규칙)의 후속이다. 15-24m 규약은 2002년 11월에 발효된 『2002년 어선(15-24미터 선박의 안전) 규칙(The Fishing Vessels (Safety of 15-24 Metre Vessels) Regulations 2002, SI 2002:2201)』에 의해 법적 효력을 부여받는다.
1.8.2 15-24m 규약
15-24m 규약은 선박이 '규약의 요건과 적용될 수 있는 규칙을 준수하는지 확인하기 위해' 검사를 받아야 한다고 요구한다. '검사원은 규약의 요건 준수를 입증하는 데 필요하다고 판단되는 시험과 검사를 선박과 그 기관, 부속품, 장비 또는 배치에 대해 받도록 요구할 수 있다.'
15-24m 규약은 선박을 검사와 점검에 제시하는 것이 선주의 책임이라고 규정한다. 15-24m 규약의 적용을 받는 모든 어선은 다음과 같이 검사 및 점검을 받아야 한다.
›건조 중과 건조 완료 시, 또는 영국 선적으로 이전할 때 UKFVC 발급에 앞서 실시하는 초기 검사.
›5년을 넘지 않는 간격으로 실시하는 UKFVC 갱신을 위한 검사.
›선박의 초기 검사 또는 직전 갱신 검사의 기록된 날짜로부터 24개월 이상 36개월 이하 사이에 실시하는 점검(보통 '중간 점검'이라 한다). 이는 선박이 계속 규약의 요건을 준수하는지 확인하기 위한 것이다.
›대규모 수리 또는 개조 중의 검사.
›선박이 규약의 주요 요건을 계속 충족한다는 것에 대한 선주 또는 위임받은 대리인의 연례 자체 증명.
중간 점검이 완료된 후 검사원이 UKFVC에 이를 배서하여야 한다. 예외적인 상황에서는 UKFVC를 5년의 유효 기간을 넘어 2개월을 초과하지 않는 기간 동안 연장할 수 있다. 필요한 경우 임시 또는 단기 UKFVC를 발급할 수도 있다. 선주는 또한 선원의 훈련과 자격증명이 유효하도록 보장하여야 한다.
1.8.3 기술 요건
15-24m 규약은 선박의 건조와 운용의 대부분 측면을 포함하는 광범위한 범위를 다룬다.
흡입구와 배출구
1975년 규칙은 기관 구역의 해수 흡입구와 배출구가 '쉽게 접근할 수 있어야 하고 밸브가 열려 있는지 닫혀 있는지를 보여 주는 지시기를 갖추어야 한다'고 규정하였다.
15-24m 규약은 이를 발전시켜, 흡입 및 선외 배출 밸브가 플로어 플레이트(floor plate) 높이 위에 설치되어 있지 않은 경우 플로어 플레이트 높이에서 밸브를 조작할 수 있는 신속하고 실용적인 수단을 갖추어야 한다고 요구한다. 규약 도입 이전에 건조된 선박의 배치는 '선체 관통부에 설치된 밸브가 접근 가능하고 사용상 효율적인 상태로 유지되는' 경우에 인정된다.
냉각수 및 기타 해수 계통
해수 배관은 알루미늄 청동, 쿠프로니켈 또는 이와 유사한 내식성 재료여야 한다. 배관을 연결하는 플랜지와 체결구 사이에 절연 패킹, 와셔 및 슬리브를 사용하여 서로 다른 금속 간의 갈바닉 부식을 방지하여야 한다.
빌지 경보
1975년 규칙은 무인 기관 구역에 구역으로의 누수를 알리는 '경고 장치'를 갖추도록 요구하였다. 15-24m 규약은 이를 한층 강화하여 빌지 경보 센서를 '선박의 추진 기관 구역과 어창'에 설치하여야 한다고 규정한다. 빌지 경보는 제어 위치에서 음향 및 시각 경고를 제공하여야 한다. 또한 규약은 기관실 빌지 경보 계통에 보조의 독립적인 빌지 경보 계통을 갖추거나, 빌지 경보 회로에 고장이 생기면 이를 알려 주는 페일세이프 경고를 갖추어야 한다고 규정한다.
1.9 법정 검사와 점검의 수행에 대한 요건 및 지침
15-24m 규약은 선박이 충족하여야 할 기술 요건을 열거하지만, 검사나 점검을 어떻게 수행하여야 하는지에 대한 지침은 없다. 이는 다른 곳에서 제공된다.
1.9.1 검사원에 대한 지침
검사 및 증서 발급 방침(MSIS 23)
검사 및 증서 발급 방침에 관한 MCA의 검사원 지침(검사원에 대한 선박검사 지침 - MSIS 23) 제2장은 UKFVC와 관련되어 있다. 이 지침은 검사의 목적이 '선체 구조, 주기관 및 보조 기관 보일러와 기타 압력 용기, 전기 계통 … 이 실무규약을 준수하고 모든 면에서 만족스러운 상태임을 보장하는 것'이라고 설명한다.
MSIS 23은 또한 침수 사고를 방지하는 데 도움이 되도록 고려하여야 할 구체적인 항목에 대한 지침도 제공한다. 가장 관련이 깊은 것은 선측 밸브에 관한 8.2.6.2항의 조언으로, '밸브 폐쇄 장치는 접근할 수 있는 위치에 있어야 하며, 밸브가 기관 플로어 플레이트 높이 아래에 있는 경우 연장 스핀들(또는 이에 상응하는 원격 폐쇄 장치)을 갖추어야 한다. 밀봉 장치를 입증하는 데에는 압력 시험이 유용할 수 있다.'라고 되어 있다. 빌지 경보와 배관에 대한 지침도 제공된다. 빌지 경보에 관하여 MSIS 23은 경보를 시험하여야 하며 선주가 보조 또는 페일세이프 경보를 설치하도록 권장하여야 한다고 규정한다. 상당한 분량의 조언이 제공된다
배관 검사에 관한 것이다. 검사원에게는 표본 추출 기법을 사용하고 무엇을 검사하였고 무엇을 검사하지 않았는지 기록하도록 권고한다. 배관이 만족스러운 상태임을 입증하는 것은 선주의 책임임이 강조된다. 해머 시험2, 초음파 계측 및 압력 시험과 같은 검사 기법이 권장된다. 검사원에게는 배관의 고위험 구역에서 대표 시료를 떼어내 상세 검사를 하도록 권장한다.
어선의 검사와 점검(MSIS 27)
어선의 검사와 점검에 관한 MCA의 지침(MSIS 27)은 15-24m 어선의 중간 점검이 UKFVC의 유효성을 유지하는 데 필요하다고 규정한다. 이전에 부여된 적용 규칙(이 경우 1975년 규칙)에 대한 면제는 가능한 한 삭제하는 것을 목표로 각 갱신 검사 때 재검토하여야 한다. MSIS 27의 1.9절은 선체와 기관 항목을 5년 주기에 걸쳐(더 큰 상선에 선급이 적용하는 것과 유사한 수준으로) 검사하는 일정을 선주와 합의하여야 한다고 규정한다. 선주는 검사 일정을 작성하여 MCA 검사원의 승인을 받도록 제출하여야 한다. 기관 및 선체 검사의 일반적인 일정 예는 각각 MSIS 27의 부속서 10과 11에 제시되어 있으며 이 절의 뒷부분에서 더 자세히 논의된다.
MSIS 27의 1.9.14절은 중간 점검을 UKFVC 발급 2주년과 3주년 사이에 실시하여야 한다고 규정한다. 이 지침은 계속해서, 중간 점검이 이루어지지 않으면 UKFVC가 '무효가 되며' 선박은 억류되어야 한다고 규정한다. 적절한 증서가 유효하지 않은 상태로 어선을 출항시키는 것은 위법이다.
MSIS 27의 1.17절은 갱신 검사의 수행과 결과를 MCA의 문서 보관 체계에 어떻게 기록하여야 하는지를 설명한다. 지침의 부속서 12로 첨부된 서식 MSF 1327은 검사 과정의 일부로 확인(및 평가)하여야 하는 문서들을 열거한다. 여기에는 '기관 정비'라는 제목의 문서가 포함되어 있으나 그 문서 자체를 보관할 필요는 없었다.
MSIS 27의 제5장은 어선 기관의 검사에 대한 상세한 지침을 제공한다. 가장 관련이 깊은 것은 5.7.6절로, '해수 배관은 점검과 정비를 위해 접근할 수 있어야 한다'고 규정한다. 이 절은 이어서 검사원이 배관 스트레이너와 격리 밸브를 철저히 점검하여야 한다고 하고 '해머 시험을 적극적으로 사용할 것'을 권장한다. 지침은 첫 갱신 검사(5년) 이후에는 해수 계통에 3바(bar) 압력 시험을 실시하여야 한다고 하나, 이를 어떻게 수행하여야 하는지에 대한 조언은 없다. 그러나 가장 관련이 깊은 것은 해수 밸브를 플로어 플레이트 높이 위에서 닫을 수 있어야 한다는 요건이다. 빌지 배수 계통에 관하여 MSIS 27의 제6장은 밸브를 플로어 플레이트 높이 위에서 조작할 수 있어야 하고 해수 콕(seacock)이 자유롭게 작동하여야 한다고 규정한다. 밸브 손잡이는 접근하기 어렵거나 급속한 침수 시 금세 접근할 수 없게 될 수 있는 구역에만 위치해서는 안 된다.
2 '해머 시험'은 물체가 '건전한지' 또는 부식되었는지를 판단하는 기법을 말한다. 상태가 좋은 배관은 두드리면 맑은 울림 소리가 나고, 둔탁한 소리가 나면 배관이 부식되었음을 나타낸다.
기관 검사에 관한 MSIS 27의 부속서 10은 검사하여야 할 주기관과 보조 기관의 상세한 목록을 제공한다. 검사 대상 항목 중 이 사고와 가장 관련이 깊은 것은 다음과 같다.
›해수/밸러스트/빌지 배관
›주 해수 냉각기(주기관 해수-청수 열교환기)
›해수 연결부: 흡입 및 배출 [sic]
부속서 11은 선체 검사 시 고려하여야 할 항목을 언급하며, 여기에는 외판(특히 흡입구와 배출구 부근)의 두께와 기관실 빌지의 상태가 포함된다.
어선 검사/점검 비망록(MSF 5550)
MCA는 다양한 어선 규약의 범위를 선주와 검사원에게 상기시키기 위해 일련의 비망록을 작성하였다. MSF 55503은 15-24m 규약의 요건을 다룬다. MSF 5550은 요건을 다음 중 어느 때 고려하여야 하는지에 따라 나눈다.
›검사 또는 점검
›점검
›선박을 물 밖에 올려 실시하는 검사.
필요한 증서와 기록의 목록도 제공된다. MSF 5550은 배관, 선체 부속품(skin fittings), 해수 콕의 상태와 그 작동의 용이성을 검사와 점검 중에 평가하여야 한다고 규정한다. 밸브는 플로어 또는 데크 플레이트 위에서 접근할 수 있어야 한다는 점도 상기시킨다. 해수 흡입구와 배출 밸브 및 콕의 상태는 선박을 물 밖으로 올려 검사할 때에도 점검하여야 한다. 빌지 펌프와 경보는 선박을 점검할 때마다 점검하여야 한다. MSF 5550을 작성할 때 이 서식은 검사원에게 UKFVC가 유효한지, 그리고 중간 점검이 실시되었는지를 확인하도록 상기시킨다.
1.9.2 기타 지침
'침수의 위험'이라는 제목의 해사지침 고시(MGN) 165(어선)는 2001년에 MCA가 발행하였다. 이는 통제할 수 없는 침수로 어선이 멸실된 MAIB의 일련의 조사들을 언급한다. 이 지침은 여러 권고 중에서도 어선 운영자에게 다음을 권장한다.
›침수의 영향을 완화하기 위해 보조 빌지 경보를 설치하고 추가 펌프를 비치할 것.
3 사고 당시에는 2009년 9월 16일자 MSF 5550 개정 2판이 유효하였다. MCA는 이 보고서가 작성되는 동안 이 서식과 관련 비망록의 여러 갱신안을 초안으로 작성하였다.
›해수 흡입 밸브를 쉽고 빠르게 닫을 수 있는 위치에 둘 것 – 필요한 경우 밸브 손잡이에 연장 스핀들을 설치하여 플로어 플레이트 아래에 설치된 밸브를 비상시에 닫을 수 있도록 할 것.
›해수 흡입 밸브가 고착되지 않도록 정기적으로(최소 월 1회) 열고 닫을 것.
›빌지 경보를 매일 시험할 것.
›선원이 빌지 배수 계통 작동 방법을 숙지하도록 할 것.
MGN 165(F)는 비상시에 모든 해수 밸브를 닫아야 한다고 권고한다.
1.10 증서 발급 및 검사 이력
선박의 증서 발급 및 검사 이력에 대한 정보를 제공하기 위해, 선박의 자문 해사(CM) 파일을 MCA로부터 입수하여 영국 선박검사 기록(SIAS) 데이터베이스에 있는 정보와 함께 검토하였다. 기관 검사(접미사 02)를 위해 따로 마련되어야 하는 CM 파일은 작성되지 않았다.
1.10.1 증서 발급 이력
1975년 규칙에 따라 발급된 Audacious호의 최초 UKFVC는 2003년 5월 1일까지 유효하였다. 이 선박은 2003년 3월 27일에 15-24m 규약에 따라 처음으로 검사를 받았다. 2003년 8월 5일에 2003년 10월 31일까지 유효한 단기 UKFVC가 발급되었다. 2003년 10월 14일자로 MCA 검사원이 선주 대리인에게 보낸 팩스 사본은 2003년 6월 27일에 경사시험(inclining experiment)이 실시되었다고 언급하였다. 이 팩스는 선박의 복원성에 대한 우려를 해소하기 위한 계획과 복원성 자료집의 작성 완료에 합의될 때까지는 더 이상의 단기 증서를 발급하지 않겠다고 밝혔다. 그러한 계획에 합의되었음을 보여 주는 구체적인 증거는 CM 파일에 없었으나, 2003년 3월 27일에 완료된 이전 검사에 기초하여 2003년 10월 30일에 또 다른 단기 UKFVC가 발급되었다. 이는 2003년 12월 31일까지 유효하였다. 세 번째 단기 UKFVC는 역시 2003년 3월 27일에 완료된 검사에 기초하여 2003년 12월 17일에 발급되었다. 이는 2004년 3월 31일까지 유효하였다.
15-24m 규약에 따른 최초의 정식 기간 UKFVC는 2004년 4월 29일에 발급되었다. 이 증서는 2003년 3월 27일에 완료된 검사에 기초하였으며 2008년 12월 31일까지, 즉 검사 완료 후 5년 9개월간 유효하였다. UKFVC는 중간 점검을 2005년 12월 31일과 2006년 12월 31일 사이에 완료하여야 한다고 명시하고 있다. 이것이 실시되었음을 보여 주는 기록은 없었다.
선박의 가장 최근 UKFVC(부속서 C)는 2008년 12월 10일에 발급되었으며 2013년 12월 31일까지 유효하였다. 이는 2008년 8월 14일에 실시된 검사에 기초하였다.
UKFVC의 계속적 유효성은 선주의 연례 자체 증명 문서 작성 완료와, 2010년 12월 31일과 2011년 12월 31일 사이에 MCA가 실시하는 중간 점검에 달려 있었다. 사고 시점까지 선주의 연례 자체 증명 문서가 작성되었거나 중간 점검이 실시되었음을 나타내는 증거는 없었다.
Audacious호의 검사 이력 중 관련된 조사 결과의 요약은 아래 표와 같다.
검사/점검 일자 검사/점검 세부 사항 1999년 5월 건조 검사: 스페인 나비아 Astilleros Armon 18, 2002년 12월 무선 검사 14, 2003년 1월 표적 점검(결함 9건 기록) 17, 2003년 3월 UK FVC 갱신 검사(결함 18건 기록) "기관실 배관 해머 시험 실시" 선체 두께의 초음파 점검 실시 10, 2004년 8월 표적 점검(결함 7건) 29, 2004년 10월 무선 검사 10, 2006년 10월 표적 점검(결함 2건) 3, 2007년 7월 (선박의 소유자 변경) UK FVC 중간 검사(수밀문에 '항해 중 닫아 둘 것(keep closed at sea)' 표지가 필요하다는 언급을 포함하여 결함 19건) 2008년 1월/2월 FV 추가(갱신) 검사(수밀문에 '항해 중 닫아 둘 것' 표지가 필요하다는 언급을 포함하여 결함 20건) 치명적 고장 후 기관을 내린 뒤 실시한 검사 선체, 기관실 격벽 및 슬러시 웰(slush well) 두께의 초음파 점검 실시. 1, 2008년 8월 무선 검사 14, 2008년 8월 기관 화재 후 실시한 검사 20, 2011년 7월 영국 만재흘수선 면제 점검 실시(촬영팀 운송을 위해) (참고: 검사원의 서면 의견: "상기 - 중간 점검은 31/12/11까지 해야 함")
표 1: Audacious호 검사 이력 중 관련된 조사 결과의 요약
1.10.2 선체 두께 계측
선체의 초음파 두께 계측은 2003년 3월과 2008년 2월에 실시되었다. 기관실 하부에서 계측 결과 평균 두께는 2003년에 12mm, 2008년에 10mm였다.
1.11 정비 이력
Audacious호가 선령 내내 정기적인 정비를 받았다는 문서상의 증거가 있었다. 해수 흡입 밸브와 흡입구에서 해양 생물 부착물을 제거하는 연례 수리가 이루어졌고, 선체 정비는 필요할 때마다 실시되었다. 기록에 따르면 선박 기관실의 여러 구간 배관을 교체하는 작업이 스코틀랜드의 한 평판 좋은 조선소에서 수년에 걸쳐 실시되었다. 교체된 배관의 크기는 직경 25mm에서 100mm 사이였으며, 직경 150mm 주기관 해수 냉각 배관에 대해서는 어느 때든 작업이 실시되었다는 기록이 없었다.
1.12 어선에서의 안전한 항해당직 유지
2006년에 MCA는 여러 선박이 멸실된 뒤 어선에서 안전한 항해당직을 유지하는 것의 중요성을 강조하기 위해 MGN 313(F)4를 발행하였다. 이 MGN은 조타실을 어느 때에도 방치해서는 안 된다고 규정한다. 항해와 관련하여 MGN 313(F)는 항해당직 책임자가 조타실에서 당직을 서야 하며 선박의 안전한 항해를 방해할 수 있는 다른 업무를 수행해서는 안 된다고 규정한다. COLREGS5 제5규칙은 모든 선박이 항상 적절하고 효과적인 경계를 유지하여야 한다고 요구한다.
1.13 어선: 선원 자격증명, 훈련 및 훈련 연습
『1989년 어선(안전 훈련) 규칙(The Fishing Vessels (Safety Training) Regulations 1989)』(개정 포함)은 다음과 같이 규정한다. "경험 있는 어부는 안전 인식에 관한 승인된 훈련 과정을 이수하였음을 증명하는 증서를 소지하지 않는 한 어선의 선장으로 근무하거나 어선에 고용 또는 종사하여서는 아니 된다." 이 규칙을 준수할 의무는 어선의 선주와 선장, 그리고 어부 본인에게 있다. 15-24m 규약(8.1.2.1절)은 선장이 어선의 선원들이 선내에 비치된 모든 구명설비의 사용에 대해 훈련을 받도록 보장할 것을 요구한다. 이러한 훈련은 1개월을 넘지 않는 간격으로 훈련 연습의 형태로 실시되어야 한다.
4 MGN 313(F): http://www.dft.gov.uk/mca/313_a.pdf 5 COLREGS = 국제해상충돌예방규칙(International Regulations for Preventing Collisions at Sea, 1972, 개정 포함)
1.13.1 어선 선원에 대한 훈련 및 자격증명 요건
2010년 3월에 MCA가 발행한 MGN 4116은 안전 인식 훈련 과정에 관하여 다음과 같이 규정한다(2.3.4). "영국 외에서 온 어부[sic]는 상선 STCW7 기본 안전 훈련을 이수하였는지 여부와 관계없이, 영국 선적 어선에서 처음 일하기 시작하기 전에 이 과정을 이수하여야 한다. 경력 2년의 어부는 안전 인식 및 위험성 평가 과정도 이수하여야 한다."
1.13.2 어선: 선원 자격증명 및 훈련 연습 점검
MGN 4308은 2011년 1월에 MCA가 발행하였으며, 선원이 승인된 안전 훈련 과정을 이수하였는지 확인하기 위해 MCA 검사원이 실시할 점검에 관하여 선주, 선장 및 선원에게 지침을 제공한다.
1.13.3 안전 인식(해상 안전 관리) 과정
Seafish가 정한 안전 인식 과정의 교육 과정에는 어선에서의 안전 관리에 대한 법적 원칙과 위험 통제 조치가 포함된다. 이 과정은 선원이 훈련 연습과 집합 훈련을 실시하는 것과 비상 상황에서 올바른 개인보호구를 착용하는 것의 중요성을 강조한다.
6 MGN 411 http://www.dft.gov.uk/mca/mgn_411.pdf 7 STCW = 선원의 훈련·자격증명 및 당직근무의 기준(Seafarers Training Certification and Watchkeeping)
requires that every vessel shall at all times maintain a
proper lookout
.
313 (F) states that no other duties should be undertaken which may interfere with the task of
lookout
. This
MGN
was issued following several collisions, groundings and near misses involving
vessels, all of which occurred as a result of poor
watchkeeping
. This accident reinforces the importance of ensuring the wheelhouse is manned at all times to monitor equipment and alarms, as well as to maintain a
proper lookout
. As no continuous wheelhouse watch was kept, the initial activation of the
engine room
alarm went unnoticed, and by the time the
crew
were alerted to the
it was too late to save the vessel. 2.4
FLOODING
OF
ENGINE ROOM
/
2.4.1 Source and rate of
flooding
The time between the engineer’s inspection of the
engine room
when he saw that the
bilge
was dry, until he returned to find water close to the top of the
, was approximately 30 minutes. Calculations made by MDI indicate that approximately 32 tonnes of water entered the
engine room
during this period. At about 1542 the
skipper
, while on his way to the
, looked down the
engine room
escape
and saw water at a level of about 0.5m above the
of the escape ladder. Based on this observation MDI calculated that a further 40 tonnes had entered the
engine room
by this time. The actual rate of water ingress at this time would have been greater than the calculated volume in the space, as a 25 tonnes per hour
was pumping water out for most of the time between the two observations.
The
flooding
rate between the two observations was calculated to be approximately 160 tonnes per hour. Flow rate calculations (Annex H) show that, with a head of 4m representing the
of the seawater cooling pipework below the
, water must have been entering the
engine room
through a
of at least 100mm in diameter. The
thickness measurements of the hull taken in 2003 and 2008 showed that the corrosion rate was not excessive; consequently there was no reason to suspect that the vessel’s hull plating had failed. It is therefore reasonable to conclude that the
flooding
was probably caused by the failure of either the main
sea
water inlet pipe or the
main engine
seawater
. 2.4.2
Stability
MDI found that there was an increase in
moment (FSM) from about 45.13tm to 229.17tm once the flood water in the
engine room
had covered the
tanks on either side of the
engine
. This took the vessel from a stable (albeit
sinking
) condition to an unstable condition. This very large and sudden increase in FSM with the consequent reduction in
stability
, demonstrates the vulnerability of the well-type of
engine room
design to
flooding
(Annex B). A relatively small amount of water can rapidly overwhelm the
main engine
and disable the vessel. If the weather had not been so calm this sudden
could have
led
to the vessel’s
. The
crew
had not appreciated the
at which the vessel could lose
stability
when the
engine room
became
flooded
, and their subsequent actions took no account of this risk when reacting to the developing emergency. 2.4.3 Extended spindles When the engineer returned to the
engine room
the
sea
intake valves were more than a metre under water and were inaccessible, so he was unable to close the valves and prevent further
flooding
.
MGN
165 (F) provides guidance on measures to prevent
flooding
on
fishing
vessels. It recommends the positioning of
sea
valves where they can be easily and quickly closed, and recommends that extended spindles be fitted ‘if necessary’ so that valves can be closed without the floor plates having to be removed. The
sea
valves on Audacious were above floor plate level, but this accident demonstrates that in cases of rapid or undetected
flooding
it can quickly become impossible to access them. If the valves had been fitted with extended spindles, level with the top of the
engine
, the engineer might have been able to shut them and stop the water ingress. While the guidance in
MGN
165 (F) identifies the need for seawater inlet valves to be accessible, this may not be sufficient if the rate of
flooding
is rapid and occurs in a well-type
engine room
. Longer extended spindles were needed to enable the
sea
inlet valves to be closed.
2.4.4
doors The
watertight
door between the
engine room
and the steering flat/workshop was left permanently open and was not labelled to indicate that it should be “closed at
sea
”. The requirement to keep
watertight
doors closed at
sea
and to label them accordingly had been noted by the
during statutory surveys, but was not complied with. As a result, water was able to flood through Audacious more quickly, and the time available to the
crew
for
was reduced.
Watertight
doors are designed to improve a vessel’s survivability in the event of
flooding
, but can only be effective if they are routinely closed when the vessel is at
sea
. 2.5
ABANDONMENT
The
crew
were instructed to return to their cabins to collect
and to then prepare the liferafts. Although they went back to their cabins, the
crew
only collected personal effects and subsequently boarded the
liferaft
without
lifejackets
. Survival suits, which were stowed in a locker near the cabins, were not collected during the
abandonment
although several valuable
sensors were taken from the wheelhouse and placed in the
liferaft
. The majority of the
crew
had not undertaken safety awareness training, contrary to the requirements of the
Fishing
Vessels (Safety Training) Regulations 1995. The
crew
were fortunate that they were able to abandon and be rescued without having to enter the water. In different circumstances their chances of survival, without wearing
lifejackets
and survival suits, could have been significantly reduced. The owner had not ensured that the
crew
held the required qualifications, and this omission was not detected during the
MCA
’s surveys or inspections of the vessel. 2.6
UkFVC
– SCHEDULING OF SURVEYS AND INSPECTIONS It was evident from the CM file and
records that Audacious did not have a
for 3 months from May to August 2003. It was then apparent that this situation was rectified by issuing a series of three short term certificates, all based on the same survey date of 27 March 2003. This was almost certainly due to a delay in the preparation and approval of the vessel’s
stability
book. A full term certificate was finally issued in April 2004, again based on the 27 March survey. This was valid until 31 December 2008, by which time it would have been 5 years and 9 months since the last
survey. This exceeded the requirement in the 15-24m Code for vessels to have a ‘
renewal
survey at intervals not exceeding 5 years’. Targeted inspections were conducted in August 2004 and October 2006, but the intermediate inspection was not completed until 7 July 2007 – by which time it was 7 months overdue. The validity of a
UKFVC
is dependent upon an intermediate inspection being undertaken, not less than 24 and not more than 36 months after the issue of the certificate. The
MCA
’s instructions state clearly that vessels
operating without valid UKFVCs are liable to immediate detention. However, there was no record of a detention, and it is likely that Audacious continued to operate during this period without a valid
UKFVC
. Audacious was surveyed by the
MCA
in August 2008, and a
UKFVC
was issued in December 2008 which was valid until December 2013. As no intermediate inspection was carried out on Audacious, it must be concluded that the
UKFVC
was not valid after 31 December 2011. The 15-24m Code states that a vessel’s owner is responsible for ensuring that the vessel is surveyed in accordance with the relevant provisions of the Code. The vessel was inspected by the
MCA
in July 2011 for the issue of a
exemption certificate and the
MCA
noted, on the report of inspection (Annex D), that a
UKFVC
interim inspection was due before the end of 2011. Despite this reminder, no intermediate inspection for her
UKFVC
was undertaken. However, despite the
MCA
’s instructions to surveyors stating that vessels should be detained when interim inspections became overdue, there was no mechanism to identify that Audacious was overdue. Poor management and communication between Audacious’s owner and the
MCA
led
to the vessel not being inspected as required and the
UKFVC
being ‘rendered invalid’. While this was contrary to the regulations, of far greater practical significance was that the vessel’s material condition fell outside the system of scrutiny provided by the
MCA
. 2.7 ANNUAL SELF-CERTIFICATION The 15-24m Code states that a vessel’s owner is responsible for ensuring the vessel is self-certified annually to confirm that safety, navigational and lifesaving equipment is in date and operating correctly, and that the
crew
’s training and certification are valid. The fact that some of the
crew
had not undertaken the requisite
safety training courses indicates that the owner’s annual self-certification procedures were not sufficiently robust. 2.8
MCA
INSTRUCTIONS TO SURVEYORS 2.8.1 Survey of
pipework The
MCA
’s Instructions for the Guidance of Surveyors
27 (Section 5.7.6), states that seawater pipes should be thoroughly checked at periodic surveys with the “liberal use of hammer testing”. It also requires that, after the first
renewal
survey, “seawater systems should be subject to a 3 bar pressure test”. In March 2003, at the
renewal
survey for her UK FVC, the
surveyor
recorded “
Engine Room
pipe work hammer tested”. This was the only reference in the vessel’s CM file to the hammer testing of
engine room
pipework, and there is no record that the seawater system pipework had ever been pressure tested.
The lack of a systematic plan to inspect the seawater cooling pipework on board Audacious, and the lack of detailed records, means that it was possible for sections of the pipework to have not been checked or replaced. It was therefore possible that some were original, i.e. 13 years old, at the time of the accident. This was contrary to the
MCA
’s survey and inspection requirements and its ‘instructions to surveyors’. 2.8.2 Aide-mémoire The aide-mémoire MSF 5550 (Annex E), issued by the
MCA
to guide its surveyors during a survey, included a reference to the condition of pipework on a vessel but did not refer to any particular test method. While an aide-mémoir can, by definition, contain only a summary of the detailed information held in the ‘instructions to surveyors’, it would be helpful to incorporate into this document a reminder of how seawater pipes should be tested. The aide-mémoire included columns where a
surveyor
could quickly record what had been included in the scope of the survey or inspection, and whether the necessary standard was met. These are not currently kept on file, so useful background information, which could guide and inform subsequent surveys, is lost. 2.9
MCA
RECORD kEEPING During the
investigation extensive reference was made to the vessel’s CM file and to the
SIAS
database. The CM file was not indexed and several reports of surveys carried out on the vessel were missing from the file. The file’s poor layout prevented a reader from being able to readily recognise that the vessel’s
UKFVC
was no longer valid. The survey records held for the vessel on
SIAS
were also incomplete; not all the surveys undertaken on the vessel had been recorded on the database. The
MCA
’s records on the survey and inspection of Audacious were incomplete and would have made it difficult for
MCA
staff to determine the validity of the vessel’s certificates, its condition or history.
FLOODING
AND
FOUNDERING
OF FV CHLOE T - SYNOPSIS On 1 September 2012 Chloe T suffered uncontrollable
engine room
flooding
and
sank
17 miles south west of Bolt Head, Devon. The
crew
were alerted to the
flooding
at about 1545 by a
alarm, indicating that there was smoke in the
engine room
. The
crew
investigated immediately and found that floodwater was spraying off the
main engine
onto the
casing and
into steam. The
engine room
flooded
rapidly and the
bilge pump
was unable to cope; the
crew
could not find the source of the
flooding
. Chloe T’s engineer/deckhand suspected that the
flooding
could be due to a failure in the
main engine
seawater
cooling system
. He was unable to close the seawater inlet
because it was quickly covered by flood water. The
skipper
realised that there was little that could be done to save Chloe T and made an early decision for the
crew
to abandon the vessel into liferafts. The
crew
all wore
lifejackets
and abandoned Chloe T safely and efficiently. A number of vessels responded to the
skipper
’s “Mayday” broadcast and the
crew
were rescued by a
helicopter. It was not possible to determine the exact cause of the
flooding
, but it was concluded that it was likely to have been caused by a failure of the
main engine
seawater
cooling system
pipework due to corrosion. There was insufficient documentation to show that the pipework had been surveyed or inspected as required by the regulations or the
MCA
’s survey instructions. There was no evidence to show that the
engine room
bilge
alarm activated during the emergency. The alarm sensor had been defective some weeks before the accident, but was cleaned and found to work. It was not tested again and was considered unlikely to have been wholly reliable. The Scottish Fishermen’s Federation, the National Federation of Fishermen’s Organisations and the Northern Ireland Fish Producers Organisation have been recommended to promulgate the lessons learned from this accident and that of Audacious, and particularly the need for
fishing vessel
operators to thoroughly inspect seawater pipework, to their members. In view of the actions taken by the owner, and the
machinery
arrangement on board his other vessels, no further recommendations have been made to the owner.
SECTION 3 - FACTUAL INFORMATION 3.1
OF CHLOE T AND ACCIDENT SHIP
PARTICULARS
Vessel’s name Chloe T Flag UK
Not applicable
Fishing
numbers PZ 1186 Type
Registered owner Langdon and Philip Manager(s) Langdon and Philip
Steel
26.44
23.55
136
Not applicable Authorised cargo No
PARTICULARS
of departure Brixham Intended
Port
of arrival Brixham Type of
voyage
Short – international Cargo information Fish
6
INFORMATION Date and time 1 September 2012, 1545 Type of
marine casualty
or incident Very Serious
Marine Casualty
Location of incident 17 miles south west of Bolt Head, Devon Place on board Complete vessel Injuries/fatalities Nil Damage/environmental impact Vessel lost Ship operation
Voyage
segment Midwater Environment Daylight, good
,
4,
sea
state 4 Persons on board 6
3.2 BACkGROUND Chloe T was built in 1968 in The Netherlands as a
beam
trawler
. Originally named Martha Lela, the vessel was brought to the UK in 1989 and renamed Angel Emiel. The vessel was sold again in 2000 and renamed Chloe T. The owner of the vessel at the time of the accident had purchased it only a few weeks beforehand on 3 August 2012. Chloe T had completed two successful
fishing
trips under new ownership; the accident occurred 3 days into the third
fishing
trip. 3.3 NARRATIVE 3.3.1 Purchase and familiarisation Chloe T was first advertised in 2011 but no sale was agreed. Langdon and Philip already operated six
beam
trawlers from the
port
of Brixham, and decided to add Chloe T to its fleet. The company employed a team of technical staff experienced in operating and maintaining
fishing
vessels, and carried out their own pre-purchase surveys. The sale was completed on 3 August 2012. Other vessels operated by Langdon and Philip were undergoing refit periods over the summer period, and the manager identified
crew
from these vessels who could operate Chloe T in the short term. In addition, an engineer/deckhand was invited to join Langdon and Philip from a different
fishing
company. He agreed and, before joining, spent most of a weekend with the previous operators of Chloe T learning about the vessel’s
machinery
. Chloe T
3.3.2 Preparation and
fishing
Chloe T was fitted with new
warps, nets and other associated
in preparation for its first trip under Langdon and Philip’s ownership. The engineer/ deckhand was provided with an outfit of tools and
to support the effective operation of the vessel. The engineer/deckhand began a process of investigating the
machinery
to develop his understanding of the systems on board. At some point during the week commencing 21 August, the engineer/deckhand found a
bilge
alarm sensor on the
port
side of the
main engine
, close to the
flywheel
. The
bilge
alarm sensor was fouled with dirt and debris and did not work. The engineer/deckhand cleaned the sensor and confirmed that the alarm worked. A number of false alarms were produced by the
bilge
alarm sensor in Chloe T’s
. The engineer/deckhand found that the
bracket had broken, allowing the alarm sensor to fall deeper into the
bilge
. He re-secured the alarm sensor and checked that the unit worked correctly. The first two
fishing
trips were reported to be successful. There had been no significant problems with the vessel or its
machinery
and the
crew
were pleased with the catches and vessel operating costs. 3.3.3 Final
voyage
Chloe T sailed from Brixham on Thursday 30 August. Soon after leaving harbour, a problem was identified with the vessel’s auto-
. Chloe T was brought back into Brixham harbour and the
-based technical team rectified the problem. The vessel sailed soon afterwards on the 3 hour passage to the
fishing
grounds. The engineer/deckhand had developed a routine of spending an hour of his afternoon/evening watch, from 1900-2000, in the
engine room
. He used this time to refill the fuel day-tanks, top up oil levels and conduct general checks of the
machinery
. He also pumped out any water that had accumulated in the
engine room
bilge
. It was reported that a small amount of water had gathered and this was pumped overboard using the vessel’s
bilge
pumping system. 3.3.4
Fishing
Chloe T’s
crew
fished throughout Friday 31 August. The engineer/deckhand conducted his routine checks in the early evening; the
machinery
was
correctly and there was no discernible increase in the
bilge
level. Although Chloe T was not being used primarily to fish for crabs, some were caught in the nets, and these were kept in a tank at the forward end of the vessel under the whaleback. A hose from the
deck
wash
was put into the tank to provide a supply of fresh seawater to keep the crabs in good condition. The
deck
wash system was supplied by the
in the
engine room
.
3.3.5 Alarm At 1400 on Saturday 1 September, the
skipper
handed over the watch to the
and went below to rest. Unable to sleep, the
skipper
returned to the wheelhouse at around 1530-1535. The
mate
kept the watch and the two men chatted. About 10 minutes later, at approximately 1545, the alarm on the
activated, indicating that there was smoke in the
engine room
. The alarm sounded throughout Chloe T and the engineer/deckhand came from the mess room to the wheelhouse to ask what was happening. Realising that it was unlikely to be a false alarm, the engineer/deckhand went to the
engine room
to investigate. The engineer/deckhand found that there was a considerable amount of steam in the
engine room
. Flood water in the
bilge
was being picked up by the
main engine
flywheel
and sprayed around the
. Water was then
on the
turbocharger
casing above the
flywheel
and being turned into steam. None of the
crew
had seen or heard the
engine room
bilge
alarm activate. 3.3.6 Emergency actions The engineer/deckhand entered the
engine room
from the main door at the
, aft end of the
engine room
(Figure 9). He closed a
valve
on the
bilge
system, which allowed the
to suck water from the
fish hold
bilge
well, and opened the
valve
which allowed the
pump
to draw water from the
engine room
bilge
. He then started the
bilge pump
using the starter panel that was fixed to the forward
engine room
. The
skipper
checked that the
fire
alarm indication was for the
engine room
alone and instructed the
mate
to begin
in the
fishing gear
. The
skipper
then followed the engineer/deckhand into the
engine room
. The deckhand who was on watch woke the remaining deckhand, who was asleep in his bunk, and both men mustered in the wheelhouse. The engineer/deckhand suspected that the most likely cause of the
flooding
was a failure in one of the seawater pipes, and he moved round to the
port
side of the
main engine
to try and find the problem. The rate of
flooding
was considerable, and the engineer/deckhand thought that it had been caused by a failure in the largest diameter pipework – the
main engine
seawater
cooling system
. However, the water was by now too deep to tell where it was
flooding
from. There were no obvious jets of water or other disturbances to indicate what the cause of the
flooding
might be. The engineer/deckhand moved past the valves controlling the seawater inlets for the auxiliary
machinery
systems to the
port
-aft corner of the
engine room
where the
main engine
seawater cooling inlet
valve
and
were situated. While there were small access holes the
valve
handle and
strainer
were beneath the
engine room
floor plates. Many of the surrounding floor plates were screwed down, and the engineer/deckhand attempted to lift these in order to gain better access to the pipework and
recollections
The water level continued to rise quickly and was soon at
deck
plate level. The arrangement of the
, above the after part of the
engine room
, reduced the space available in the area of the
main engine
seawater cooling inlet
valve
(Figure 10). Consequently, the engineer/deckhand would have needed to crawl into this low space, with flood water rising around him, in order to reach the
valve
. Deciding not to stay in this potentially hazardous area, the engineer/deckhand abandoned his attempts to reach the
main engine
seawater cooling inlet
valve
and withdrew to the main part of the
engine room
. 3.3.7 Deterioration Water had been spraying from the
main engine
flywheel
for some time; a combination of the spray and the steam produced from contact with hot
machinery
caused the
running
(
port
) generator to shut down. Chloe T lost main electrical power and the
bilge
and general service pumps stopped. The engineer/deckhand moved back over to the
starboard
side of the
engine room
and started the
starboard
generator. With electrical power restored, he re-started the
bilge pump
. The
skipper
saw that the situation was deteriorating, and left the
engine room
to go back to the wheelhouse to make a
radio
to the
. At about the same time, the
fishing gear
was starting to be hauled off the seabed and its full weight came onto the vessel’s lifting beams. Chloe T began to roll slowly, and it was evident to the
crew
that the vessel’s margin of
stability
had reduced significantly. The
skipper
instructed the
mate
to lower the
gear
back to the seabed; the
mate
allowed the winch to pay out until the end of the
towing
wires ran off the winch drums. At 1618,
coastguard
in the
(
MRCC
) at Brixham recorded a
VHF
call
made by Chloe T’s
skipper
reporting that the vessel was ‘taking water in the
engine room
’. Two minutes later, the log was updated stating that the vessel had lost power, and the water level in the
engine room
had risen above the
. The
skipper
also reported that the
crew
had
lifejackets
on and were preparing Chloe T’s liferafts. At 1622, the
coastguard
recorded that a “Mayday” message had been broadcast. 3.3.8
Abandonment
The water level in the
engine room
continued to rise, and the
starboard
generator stopped due to the ingress of water spray and steam. With the
fishing gear
run off, there was no longer any need to have power for the winch, which was driven by the
main engine
. The engineer/deckhand stopped the
main engine
and re-started the
port
generator. He then re-started the
bilge pump
. The engineer/deckhand came onto the
to discuss the situation with the
skipper
and
crew
. At the same time, he was able to confirm that water was being pumped out from the
bilge pump
discharge
overboard. The engineer/deckhand returned to the
engine room
. By now the water was reported to be waist deep, having risen approximately 6 inches in a 10-minute period. There was still no indication of the cause of the
flooding
. The emergency hand-operated
bilge pump
fitted to Chloe T was not considered by the
crew
to be of much help, and a portable, independently-powered salvage
pump
, as recommended by the MCA9, 9 The
MCA
recommends in both
(
MSN
) 1770F ‘The
Fishing Vessel
Code of Safe Working Practice for the
Construction
and Use of 15 metre
length overall
(
LOA
) to less than 24 metre
registered length
(RL)
Fishing
vessels’ and
Marine Guidance Note
(
MGN
) 165 (
Fishing
Vessels) ‘The Risk of
Flooding
’ for an independently powered salvage
pump
to be carried on board
fishing
vessels.
Engine room
Figure 11: Chloe T —
had not yet been purchased. Similarly, the engineer/deckhand had not yet identified if, or how, the
general service pump
could be made to draw suction from the
engine room
bilge
. He did not know if the
main engine
seawater cooling
pump
could take its suction from the
bilge
. The
skipper
concluded that there was little he or the
crew
could do to save the vessel. He instructed the
mate
and remaining deckhands to
the two, 6-person capacity, liferafts over the
. They both inflated correctly and were secured in the lee on the
port
side of Chloe T. At 1634,
coastguard
officers
recorded that the
skipper
had reported that the liferafts were inflated, and the
crew
were mustered at Chloe T’s
stern
. The door to the
engine room
, and the majority of the doors on the
upper deck
, were closed. The
mate
and one of the deckhands boarded the first of the two liferafts. The engineer and the other deckhand boarded the second
liferaft
. Finally, the
skipper
boarded the first
liferaft
. The deckhand and the engineer/deckhand, who had been on watch before the accident, both wore their personal flotation devices, which were routinely worn during
fishing
operations. The remaining
crew
wore fixed
abandonment
lifejackets
. There were no immersion suits on board. The vessel’s
was carried in one
liferaft
and a hand-held
VHF
radio in the other. The
crew
cut the painters, lashed the liferafts together and allowed them to
away from Chloe T. 3.3.9 Rescue A number of vessels responded to the “Mayday” broadcast, including Maersk Patras, the Brittany ferry Armourique, M/V Mair (on
to Trinity House), Dart Angler and the
fishing
vessels Amber J and Lady Maureen. The
search and rescue
helicopter R193 arrived on scene and, by 1721, was reported to be winching Chloe T’s
crew
from the liferafts. Salcombe
(
RNLI
) All Weather Lifeboat reached Chloe T’s
position
at 1726. The
skipper
of Lady Maureen, another vessel operated by Langdon and Philip, volunteered to board Chloe T and attempt to rig a salvage
pump
. He was advised against boarding in case the vessel suddenly
capsized
, and no further attempts to salvage the vessel were made. Chloe T
sank
at 2226 (Figures 11-14).
Figure 12: Chloe T (picture taken at 1855) Figure 11: Chloe T (picture taken at 1757)
Figure 13: Chloe T (picture taken at 2013)
3.4
CREw
AND kEY PERSONNEL 3.4.1
Crew
All five of Chloe T’s
crew
were UK nationals and each had completed the four mandatory Seafish training courses. Chloe T’s
skipper
was aged 39 and had held a Class 2
fishing
certificate10 since 2000. The
skipper
had been working for Langdon and Philip for about one year and was the regular
skipper
of another vessel, which was out of service being refitted. He was to
skipper
Chloe T for about 1 week, while the vessel’s regular
skipper
took a holiday. The regular
skipper
had shown him the
fishing
operation of Chloe T, but the
skipper
had not yet studied the detail of the
bilge
alarm or pumping arrangements. The
skipper
kept wheelhouse watches from 0800-1400 and from 2000-0200. The
mate
was aged 30 and had been
fishing
all his working life. He was part way through his studies to gain a Class 2
fishing
certificate. The
mate
normally worked as a deckhand on another of Langdon and Philip’s vessels. This vessel was also being refitted and he was standing in for the regular
mate
who was on sick leave. 10
Deck Officer
(
Fishing Vessel
) Class 2 Figure 14: Chloe T (picture taken at 2020)
The
mate
had visited Chloe T’s
engine room
only once, while the vessel was on passage to the
fishing
grounds. He kept wheelhouse watches from 0200-0800 and from 1400-2000. The engineer/deckhand was 47 years old. Although he did not have any formal engineering qualifications, he had worked at
sea
on board
fishing
vessels for the last 30 years, 25 of which as an engineer. He had also spent a 3-year period working ashore
running
his own business, before deciding to return to
fishing
. He had been on board Chloe T since it was purchased by Langdon and Philip. He had also spent time learning about the vessel’s
machinery
and systems with the previous owner’s
crew
during the weekend before the sale was completed. The engineer/deckhand kept watches from 0400-1200 and from 1600-0000. Chloe T’s nets were hauled every 2 hours and the engineer/deckhand had a routine of checking the
engine room
after each haul. He also spent from around 1900-2000 each day in the
engine room
, making more detailed checks of it, refilling the fuel day tank, adding lubrication oil and emptying water from the bilges. The two other deckhands were both very experienced fishermen and kept watches of 8 hours on duty, followed by 4 hours off duty. Neither was involved with the operation of the vessel’s main
machinery
. 3.4.2 Other key personnel Langdon and Philip operated a fleet of six other
fishing
vessels. The company employed three
shore
-based technical staff to support and maintain the vessels when they were alongside. 3.5
MACHINERY
ARRANGEMENT 3.5.1
Main engine
The
main engine
was a Stork 6FHD240 driving a fixed
through a
gearbox. The
engine
turbocharger
was positioned at the aft end of the
engine
, above the
flywheel
. A power-take-off at the forward end of the
engine
drove hydraulic pumps which provided power to the main
towing
winch and
steering gear
respectively. The
engine
was arranged to start with compressed air.
Main engine
cooling was provided by a closed circuit
fresh water
system which passed through a heat exchanger to an open circuit seawater system. Both the pumps for the fresh and seawater systems were mechanically driven from the
engine
. The
main engine
cooling seawater inlet was a through-hull fitting positioned at the after end of the
engine room
on the
port
side. The vessel’s Record of
Particulars
held in the
MCA
’s CM file indicated that the
main engine
seawater cooling pipework was 85mm diameter and the seacock was a
screw
down non-return type. A strum box
strainer
was fitted after the seacock. There were no additional valves to isolate the
strainer
for cleaning. The type of material used for the seawater pipework on Chloe T was not recorded in the
MCA
’s records. The material used for the valves was identified as NF – assumed to mean non-ferrous, and therefore probably a copper-nickel alloy.
3.5.2 Generators Two
-driven generators were fitted, one to each side of the
main engine
. The generators were
-cooled;
fresh water
in a closed circuit system was pumped through the
engine
and then into a sealed heat exchanger mounted on the outside of the hull where it was cooled by the surrounding seawater. The vessel’s original direct current (DC) system was replaced with a 415V alternating current (AC) system in 1997. 3.5.3
Bilge
pumping There were no details relating to the type or capacity of the
bilge
pumps in the vessel’s Record of
Particulars
, contained in the CM file. However, an un-dated maintenance report from the then owner, which was attached to other papers relating to surveys for the
renewal
of the
UKFVC
in 2002, stated that there were two, 3 inch electrically-driven Stork pumps. One of these was to be renewed during a planned refit in 2002 due to
on its casing. The pipework was recorded as being mild
steel
, of 85mm diameter consistent (though not identical) with the pumps having 3 inch suction and
discharge
connections. Pumps of this type were estimated to be capable of pumping about 1000 litres of water per minute or 60 tonnes per hour. A seawater inlet was provided to prime the
pump
. The
bilge
suction
valve
chest was situated towards the forward end of the
engine room
on the
starboard
side.
Bilge
suctions could be taken from the
peak,
fish hold
, and
engine room
. The
discharge
overboard was above the
waterline
through a non-return
valve
on the vessel’s
port
side. A hand-operated
pump
was also fitted as an emergency
bilge pump
. It was not used during the accident. Other vessels operated by Langdon and Philip were provided with portable petrol-powered pumps, as recommended by the
MCA
, for use as emergency salvage pumps. Chloe T did not have one of these pumps when it was sold and the new owners had yet to purchase one. 3.5.4
Deck
wash A second electrically-driven ‘3 inch’ Stork
pump
attached to 85mm diameter pipework was provided as a
general service pump
. This was configured as a
deck
wash system. A
manifold
on the main working
deck
diverted the main flow of water to the crab tank at Chloe T’s forward end. Water overflowed from the tank onto the
deck
and overboard through the scuppers. The
pump
was only turned off while the catch was landed on
deck
to prevent fish being washed overboard. Although it was likely that the
general service pump
could be reconfigured to work as a
bilge pump
, none of the
crew
on board Chloe T at the time of the accident had identified if, or how, this could be done. 3.5.5 Other seawater systems A
sea
chest to the
port
side of the
main engine
provided seawater to the refrigeration system condenser, and priming for the
bilge pump
and the hydraulic system
cooler
.
3.5.6
Bilge
alarms Chloe T’s
crew
were able to confirm that there were
bilge
alarm sensors in both the
fish hold
and the
engine room
. The alarm panel was in the wheelhouse and gave an audible alarm if any of the sensors were activated. A set of lights indicated which alarm sensor had been activated. The panel was also fitted with a test function which was reported to have shown that all the
bilge
alarms functioned correctly. The
fish hold
alarm sensor had initially given a number of premature alarms, caused by it becoming detached from its mounting and falling into the
bilge
. This was repaired by the engineer/deckhand, and the alarm worked correctly thereafter. The engineer/deckhand had found one
bilge
alarm sensor in the
engine room
. This was situated on the
port
side of the
main engine
, close to the
flywheel
. It was initially reported not to have worked, however after cleaning, it functioned correctly. The engineer/deckhand did not know if there were any other secondary or high level
bilge
alarm sensors fitted in the
engine room
. 3.6 MAINTENANCE AND SURVEY HISTORY Langdon and Philip had no survey or maintenance history for Chloe T, beyond the statutory certificates, having owned the vessel for only a short time. Very few documents were passed over with the sale of the vessel. 3.6.1 Official records The Consultative Marine (CM) files which were held by the
MCA
for Chloe T were studied to provide an indication of the vessel’s survey and maintenance history. CM files are kept to provide documentary evidence to support the issue of statutory certificates – principally, the UK
Fishing Vessel
Certificate (
UKFVC
). The CM file was not required or intended to represent the complete maintenance history of the vessel. A number of separate files, each for a specific topic, may be created for each vessel. Chloe T files had CM files relating to its
construction
(01 suffix) and
stability
(04 suffix). There was no record of a file relating to the vessel’s
machinery
(02 suffix) ever having been created. 3.6.2 Early history of the vessel Chloe T was first surveyed when it was brought onto the UK
in 1989. In 1994, a
deck
was added at the
stern
to improve the vessel’s
stability
characteristics and to ensure that it met the requirements of The
Fishing
Vessels (Safety Provisions) Rules 1975 (hereafter referred to as the 1975 rules). The vessel had a major refit in 1997/98 when the
main engine
was overhauled, and a significant amount of the seawater system pipework was renewed. The vessel changed ownership in 2000; the next record of any work on the seawater system was in 2002, when it was noted that all the
sea
valves were removed, overhauled and replaced. Although there was no specific mention of the seawater pipework having been checked, it is likely that at least some parts of the pipework were seen when the valves were removed. The owner’s report to the
MCA
, regarding
engine room
maintenance at about that time, stated that the
bilge
pumps were serviced annually.
3.6.3 Surveys for the
renewal
of the
UkFVC
- 2002 The surveys for the
renewal
of the
UKFVC
in 2002 took place from March to July 2002. The
MCA
’s records showed that a
(with ultrasound thickness measurements) and a light ship displacement check had been completed. A review of the Record of
Particulars
(MSF 1301) showed that: • No sketch of general layout, plan and profile had been completed as required by the instructions on MSF 1301. • The section relating to
bilge
pumps was partly completed. There was no record of the
compartment
in which the
pump
was situated or the
pump
’s capacity. In the column ‘Source of power and its
position
in vessel’ was written ‘Audible and visible in W’house from E.R.’ • There was no record of the
bilge
pumps being tested as required by the instructions on MSF 1301. • An exemption was granted from the 1975 Rules Section 37(1)(b)(7): Every vessel of 12 metres in length and over but less than 24.4 metres in length to which these Rules apply shall be provided with: o (1)(b) not less than two
bilge
pumps (i) having a total capacity of not less than 455 litres per minute if the vessel is 20 metres in length and over but less than 24.4 metres in length. At least one such
pump
shall be a power
pump
having a capacity of not less than 230 litres per minute. Where two power pumps are provided each
pump
shall be independently driven; o (3) In any such vessel a
general service pump
of sufficient capacity may be used as an independent
bilge pump
. o (7) In every such vessel – (a) if the vessel is 15 metres in length and over but less than 24.4 metres in length
bilge
branch suction pipes shall be not less than 50 millimetres inside diameter; The
UKFVC
was issued on 8 November 2002, valid until 24 February 2006. The previous
UKFVC
had expired over 8 months previously, on 24 February 2002. There was no evidence of any interim certificates or extensions being granted during this period. 3.6.4 Surveys for the
renewal
of the
UkFVC
- 2006 The surveys for the
renewal
of the
UKFVC
, due on 24 February 2006, began in November 2005. The
renewal
survey (conducted 25 November 2005); included the following deficiencies:
•
Gear
box cooling pipe to renew as discuss and ME suction strum to SW
pump
• Fit 2nd independent
bilge
alarm in
engine room
• Prove E.R (
engine room
) and F.R. (
fish hold
)
bilge
alarms • Mark location of
sea
-cocks in
engine room
[sic] A
surveyor
from the
MCA
’s marine office local to Chloe T’s
wrote to the vessel’s owner on 14 February 2006 reminding him that the
UKFVC
would expire on 24 February, and that the vessel would need to be taken out of the water for a
hull survey
. The owner replied on 16 February and requested that the
hull survey
be deferred until an unspecified date when the local slip became available. A series of six short-term certificates was provided to cover the period from 22 February 2006 until 1 February 2007. These were held locally and were not included in the vessel’s CM file or on
SIAS
. The Report of Hull Condition of a
Fishing Vessel
(MSF 1328) stated that an ultrasound
hull survey
was carried out on 10 July 2006. A full term
UKFVC
was issued on 1 February 2007, valid until 24 February 2011. The certificate and the accompanying documents recorded that: • The exemption from 1975 Rules Section 37(1)(b)(7) was continued. Exemption 62 was removed; the vessel had been fitted with a
fire detection system
. • The
fish hold
bilge
well was cleaned and lined with screed (having been found to be thinning due to erosion). • All seacocks and
discharge
overboard valves were removed, cleaned, inspected and returned to the vessel. All external gratings were removed and cleaned. • The CM file document checklist (
fishing
vessels) MSF 1327 dated 30/01/07 included
of a
machinery
maintenance survey report. The record of
particulars
(form MSF 1301) was not completed in accordance with the requirements stated on the form: • No photograph of the vessel was attached. • There was no sketch: general layout; plan and profile. • The section on
bilge
pumps was partly completed. There was no record of the
compartment
in which the
pump
was situated or the
pump
’s capacity. Under the column ‘Source of power and its
position
in vessel’ was written ‘Audible and visible in W’house from E.R.’ The
bilge
pumps were recorded as having been tested in September 2006. The covering letter dated 1 February 2007 stated that the
UKFVC
would only remain valid if the owner completed annual self-certification checks, and an intermediate inspection was held between February 2008 and February 2009.
3.6.5 Inspections between 2007 and 2011 The
MCA
’s
SIAS
database (Annex F) recorded that targeted inspections were conducted on Chloe T on 8 November 2007 and 28 May 2008. The nature of the targets was not identified, but deficiencies were recorded. Each of the deficiencies (from both inspections) were noted on
SIAS
as ‘Relates to survey - I’. There was no specific record, in either
SIAS
or the CM file, confirming that the annual selfcertification checks or the intermediate inspection had been conducted. The copy of the
UKFVC
held in the CM file was not updated to record that inspections had been conducted. Similarly, there was no record that the annual selfcertification declarations had been completed by the owner. A copy of a document reporting the maintenance carried out on Chloe T during 2010 was obtained from the
MCA
’s informal local ‘working’ file. The document was unsigned, but appeared to have been provided on the owner’s behalf. The
of maintenance included a statement that the ‘
port
and
starboard
bilge
and general service pumps’ had been overhauled and that ‘various’ pipes had been renewed as necessary. 3.6.6 Surveys for the
renewal
of the
UkFVC
– 2011 The surveys for the
renewal
of the
UKFVC
in 2011 began on 19 January 2011. The
MCA
’s local
surveyor
identified a number of deficiencies, of which the most relevant to the accident was to ‘Prove all
machinery
alarms’. Other survey deficiencies indicated that the
surveyor
had paid particular attention to checking emergency drills,
crew
certification and
. The
surveyor
had ticked off and dated when each deficiency had been rectified. In addition, the
surveyor
had also signed the survey report stating that all the deficiencies had been rectified by 26 April 2011. A hull condition survey was conducted on 21 February 2011 with the vessel slipped. The hull was found to have not deteriorated significantly since the previous survey 5 years before.
Sea
chests,
bilge
suction wells and the soil pipe were all found to be in an acceptable condition. A lightship survey was conducted on 24 February 2011 and the results were found to compare well with previous checks, and no further review of Chloe T’s
stability
information was required. The
UKFVC
expired on 24 February 2011. Three short-term certificates were issued to cover the period from 28 February 2011 to 1 August 2011. An unofficial form, titled ‘
Fishing
Vessels (Safety Provisions) Rules 1975 – Exemption required from the application of the following Rules:
Steel
Hull Vessels: Under 24.4m length Reg.’ listed a number of references to different parts of the 1975 Rules. The majority of these references (including Section 37(1)(b)(7), relating to
bilge
pumping) had been highlighted. The form had been signed where it was labelled ‘signature of owner’ and was dated 18 March 2011. A report of an electrical survey, dated 25 February 2011, stated that Chloe T’s electrical systems were all in good condition. No earth faults were detected and the cables were identified as being double insulated and of good quality. It was also reported that the vessel’s
was fitted with a built-in meter allowing operators to check for earth faults easily.
The
MCA
form ‘CM File Documents Checklist (
Fishing
Vessels) MSF 1327’ indicated that a ‘Service Report –
Machinery
’ had been sighted. However the checklist form was not signed or dated. The Record of
Particulars
(MSF 1301) was updated, based on a final survey date of 18 July 2011 (Annex G). It was not completed in accordance with the requirements stated on the form: • No photograph of the vessel was attached. • There was no Sketch: General layout; plan and profile. • The section on
bilge
pumps was partly completed. There was no record of the
compartment
in which the
pump
was situated or the pumps’ capacities. Under the column ‘Source of power and its
position
in vessel’ was written ‘Audible and visible in W’house from E.R.’. The
bilge
pumps were recorded as being tested in March 2011. The Record of
Particulars
stated that the
engine room
had been fitted with a ‘secondary’
bilge
alarm and that the system had been tested by an
MCA
surveyor
, and found to be satisfactory, in March 2011. A full-term
UKFVC
was issued on 21 July 2011, valid until 26 February 2016. The exemption from the 1975 Rules regarding
bilge
pumping (Section 37(1)(b)(7)) was granted. The covering letter attached to the
UKFVC
reminded the owner that annual self-certification needed to be conducted and an
must take place between February 2013 and February 2014. 3.6.7 Other surveys and inspections A valuation survey of Chloe T was conducted on behalf of the vessel’s owners on 30 September 2011. The
bilge
and general service pumps were identified in the
list
of
machinery
, but there were no comments relating to the condition or age of the
sea
inlet valves or salt water pipework. The survey concluded that the
engine room
‘appeared to be in very good condition with evidence of recent and effective maintenance. The main, auxiliary and ancillary
machinery
appeared to be in a fully operational and well-maintained condition.’
MCA
surveyors conducted two further targeted inspections on board Chloe T. The first, on 2 February 2012, was related to the fitting of a new
trawling
winch. The second required the vessel to be fitted with an
(
AIS
).
SECTION 4 - ANALYSIS 4.1 AIM The purpose of the analysis is to determine the contributory causes and circumstances of the accident as a basis for making recommendations to prevent similar accidents occurring in the future. 4.2
ENGINE ROOM
FLOODING
By the time the
crew
were aware of the water
flooding
into the
engine room
, the level was already too high to allow them to see where it was
flooding
in from. The level continued to rise and it never became possible to confirm the cause of the flood. The possibility of Chloe T being deliberately
flooded
for financial reasons was considered, but was dismissed because: • The vessel was reported to be operating successfully and profitably. • There was a substantial period before the next
renewal
survey was due. • Additional tools,
spares
and
fishing gear
had been purchased and put on board. • The vessel was part way through a
fishing
trip and already had a valuable catch on board. 4.2.1 Potential sources of
flooding
There were two principal ways that water could have
flooded
into Chloe T’s
engine room
: the first was a failure of the hull plating, and the second was a failure in one of the seawater systems.
Flooding
through the
propeller shaft
seal can be discounted because the water level was below the
propeller shaft
when the engineer/deckhand first entered the
engine room
, and no sign of water ingress was seen in this area. Back-
flooding
through the
bilge
pumping system can also be ruled out as the
valve
had been left open to
pump
from the
fish hold
. The valves were reconfigured by the engineer/deckhand as soon as he entered the
engine room
after hearing the alarm. Any back-
flooding
would therefore have
flooded
the
fish hold
and not the
engine room
. Similarly, a failure in the
general service pump
discharge
(deckwash) system can be discounted. The system was set up to
pump
water into the crab tank on the
deck
near Chloe T’s bow. The
engine room
still continued to flood even though the
general service pump
was not restarted after the diesel generator tripped. 4.2.2 Hull plating failure There was no evidence to indicate that Chloe T had
with any objects in the water or that its hull plating had become damaged while the
fishing gear
was being handled.
The two most recent hull surveys (2007 and 2011) recorded that the hull plating was of an acceptable thickness. More importantly, there was little difference in the results from the two surveys, indicating that there was not much active corrosion. While there can be no guarantee that this stable situation continued through the 19 months from the last
hull survey
until the accident, such a rapid increase in the rate of corrosion could only be caused by a significant change and would probably have been noticed. One reason for a significant increase in the rate of hull plating corrosion could be electrolytic action caused by a fault in Chloe T’s electrical system. Typically, a result of electrical insulation breaking down or other earth leakage faults, is that areas of hull plating can become anodic and can corrode rapidly. However, the most recent electrical survey report concluded that Chloe T’s electrical systems had been installed to a high standard and were maintained in a good condition. Consequently, this potential cause is considered to be less likely. Another cause of hull plating failure is localised erosion, normally occurring over several years close to
bilge
suction points. This problem had been found in Chloe T’s
fish hold
bilge
well during the
hull survey
in 2007. The
bilge
well was repaired and no further deterioration was recorded. The condition of the hull plating close to the
engine room
bilge
suctions was not specifically noted in either of the most recent hull surveys. However, ultrasound thickness readings of the hull plating did not show any concerns. 4.2.3 Seawater system failure All the most recent survey reports recorded that the hull suction and
discharge
valves had been removed, overhauled and replaced. It is therefore reasonable to expect that these were in an acceptable condition at the time of the accident. The plating of the
sea
box was also in reasonable condition. The seawater systems consisted of inlet and
discharge
pipework for
main engine
cooling, refrigeration and hydraulic cooling and the general service pumping system.
Discharge
overboard pipes were all recorded as being fitted with non-return valves. There were references, in working notes or from records of deficiencies, that some sections of pipework had been renewed from time to time. However, there was no record of the layout of the seawater systems or, importantly, exactly which sections of pipework had been renewed. It is notoriously difficult to get access to every section of pipework in vessels of Chloe T’s style and age; the systems are extensive and complex by modern standards and many are placed low down in the
bilge
, often obstructed by major components. It is not surprising therefore that the records in the CM file often referred to replacing pipework ‘as required’. All these factors strongly suggest that there was no methodical plan to inspect or replace the seawater system pipework. Pipework failure, due to some form of undetected corrosion, is a common cause of
engine room
flooding
; Chloe T’s
construction
and history suggest that the vessel would have been particularly vulnerable to this problem. Consequently, the most likely source of the
flooding
is considered to be from the failure in part of the seawater system pipework.
4.2.4
Flooding
rate By the time the engineer/deckhand entered the
engine room
, enough water had
flooded
in to prevent him from seeing where the water had come from. He then started the
bilge pump
, which was estimated to have had a capacity of 60 tonnes/ hour. The water level continued to rise above the floor plates and was later estimated as having risen ‘6 inches in 10 minutes’. At this stage, the sides of the
engine room
(formed by the hull plating and bulkheads) would have been largely vertical. If viewed from above, the surface of the water would have appeared to be roughly square in shape, with each side approximately 6.5m long. If the volume occupied by the
main engine
and other
machinery
is ignored11 to simplify the calculation, the rate of
flooding
can be estimated as being 39 tonnes / hour. Assuming that the
pump
was working at its maximum capacity, the total rate of
flooding
would have been 39 plus 60 tonnes / hour. Given the obvious limitations of this estimation, the total rate of
flooding
can be approximated to 100 tonnes / hour. Chloe T was reported to have had a
of 2.8m. The seawater systems would have been close to the hull plating, so it has been assumed that they would have been about 2.7m below the
waterline
. Using Bernoulli’s theory for steady flow through an orifice, it is possible to determine that a
hole
of about 88mm (3 ½ inches) diameter, 2.7m below the
waterline
, will cause a
flooding
rate of about 100 tonnes / hour (Annex H). A similar rate of
flooding
could also have been caused by a failure in pipework on the
discharge
side of the
main engine
sea
water cooling
pump
. In these circumstances the water would be forced out by the
sea
water cooling
pump
and the same rate of
flooding
could have come from a smaller sized
hole
. 4.2.5 Most likely cause The estimation in the previous section suggests that the rate of
flooding
could only have been caused by a substantially sized
hole
; this must have been caused by a significant failure. As previously discussed, the most likely cause of such a significant failure was a failure in part of the seawater system, due to corrosion. Given the likely size of
hole
required, the failure probably occurred in part of the
main engine
. The
flooding
continued, at much the same rate, even after the
main engine
was shut down. It is therefore more likely that the
hole
was in pipework on the inlet side of the
sea
water cooling
pump
and that the
flooding
was due to static
sea
water pressure alone, without the additional effect of the
pump
discharge
. 4.3
FLOODING
wARNINGS 4.3.1 General principle
Flooding
can only be controlled if water is pumped out faster than it can leak in. This can be done either by adding more pumps, or by finding the source of the flood and restricting the rate of
flooding
. While this sounds obvious, in practice there is always a maximum rate at which any vessel can
pump
out water even if every
pump
on board is used.
Flooding
can then only be stemmed if the source can be found. This 11 The volume of the
engine room
occupied by the
machinery
would be a relatively small proportion compared with the total volume of the
engine room
.
is extremely difficult once the depth of the flood is beyond a few tens of centimetres. It is therefore essential that
crew
are alerted as soon as
flooding
starts – reliable, correctly positioned
bilge
alarms are essential. 4.3.2
Bilge
alarms on board Chloe T Chloe T was fitted with one
bilge
alarm sensor close to the
main engine
flywheel
. The
bilge
alarm sensor was dirty and did not work when it was found by the engineer/deckhand. He cleaned it and found that this made it work again. However, there was no guarantee that the sensor would stay clean or keep working. It might easily have become coated in
engine
oil again and prevented from operating; any oil leaking from the
oil seal would soon have found its way onto the
flywheel
. The MSF 1301 form from July 2011 records that Chloe T was fitted with a secondary
bilge
alarm sensor. However, the
crew
did not know where this was located, or if it worked correctly. The
bilge
alarm close to the
main engine
flywheel
was not tested at the beginning of the final
voyage
and it did not operate during the accident; there can be little confidence that it worked reliably. 4.3.3 Secondary
bilge
alarms
Bilge
alarm sensors need to be capable of operating in harsh conditions. However, there is a limit to what the sensors can withstand, and they need to be checked and replaced periodically. This time period will reduce on board vessels which routinely have wet or oily bilges, and Chloe T will have suffered from both these problems during her working life. There was no record of when the
bilge
alarm sensors were last replaced and, potentially, they could have failed at any time. 4.4 EMERGENCY RESPONSE 4.4.1 Response to
flooding
The
skipper
,
mate
and engineer/deckhand responded promptly to the smoke alarm. They realised that there was no obvious explanation for the alarm and went to investigate. Other
crew
were alerted and mustered. The
flooding
was obvious and the engineer/deckhand immediately started the
bilge pump
and configured the valves to draw water from the
engine room
. He, and latterly the
skipper
, then searched the
engine room
to determine the source of the flood. With the source of the flood obscured, there was no immediate action that could be taken to reduce the rate of water ingress. The engineer/deckhand sensibly concluded that a seawater system pipework might be the cause, and attempted to shut the
main engine
seawater inlet
valve
. This was not easily accessible with the increasing level of the floodwater. Locating and operating the
valve
would have put the engineer/deckhand into an extremely hazardous situation, and he wisely decided not to take the risk. However, the situation faced by the engineer/deckhand was entirely foreseeable and could have been avoided. The
MCA
and other organisations have published guidance over many years which advises that there should be some means of closing valves once they are submerged under flood water and are otherwise inaccessible. Other options were available even though the
main engine
seawater inlet
valve
was inaccessible. The
general service pump
probably could have been reconfigured to
pump
from the
engine room
, however none of the
crew
on board at the time knew
how to do this. This
pump
was identical to the
bilge pump
and, if it is assumed that both were capable of pumping 60 tonnes per hour, it is possible that the flood could have been contained by using both pumps together12. The inlet valves for the other seawater systems were more accessible and could have been shut. Even if this had not affected the rate of
flooding
, it might have helped improve the chances of later salvaging the vessel.
Hauling
the nets, while an understandable reaction to any emergency on a
fishing vessel
, unnecessarily reduced Chloe T’s margins of
stability
even further. The
crew
were quick to recognise this and resolved the problem by
running
the
towing
wires off the winches. 4.4.2
Abandonment
The
skipper
informed the
coastguard
about the
flooding
very quickly, and subsequently broadcast a “Mayday” message as soon as he realised that the flood could not be controlled. A number of vessels responded to the “Mayday” and stood by to offer assistance. As soon as the
skipper
identified that there was little more that could be done to control the
flooding
, and that Chloe T’s margin of
stability
was reducing, he took the decision for the
crew
to abandon the vessel.
Crew
members had already been instructed to prepare the liferafts; these had been inflated and secured in the lee of the vessel. All the
crew
wore
lifejackets
, either their PFDs which were routinely worn when working on
deck
, or their
abandonment
lifejackets
. Each
crew member
was able to board a
liferaft
without entering the water. A portable
VHF
radio was taken on board one
liferaft
, and the
EPIRB
on the other. This meant that if the liferafts had subsequently become separated, each had a way of attracting attention over a long range. There was evidence, both from
crew
reports and the
MCA
surveyor
’s records, that emergency drills had been conducted on Chloe T. This was extremely commendable and no doubt helped the
crew
’s response during the emergency. The
skipper
’s early decision to abandon Chloe T and the
crew
’s well-considered response meant that the risks to them and any potential rescuers were minimised. 4.5 ROLE OF THE OwNER AND
CREw
4.5.1 Responsibility The 15-24m Code makes it clear that it is the owner’s responsibility to present his vessel for surveys and intermediate inspections. The owner (or his delegated representative) also has a responsibility to complete the annual self-declarations, confirming that the vessel still meets the requirements of the Code. Apart from these obligations, the owner and
skipper
also have more practical responsibilities to ensure that the vessel is seaworthy and can be operated safely. 12 The
flooding
rate was estimated to be about 100 tonnes per hour. If the
bilge
and
general service pump
were 3 inch Stork pumps, each with a capacity of 60 tonnes per hour, the potential maximum pumping rate was 120 tonnes per hour.
4.5.2 Purchasing and familiarisation The owner of Langdon and Philip, and his staff, had a great deal of experience of operating and maintaining
fishing
vessels. They were not obliged, by insurance or other financial reasons, to obtain a formal pre-purchase survey. They were reassured that Chloe T had completed its statutory
renewal
survey relatively recently and felt sufficiently confident to assess the condition of Chloe T for themselves. They would have needed to conduct a very detailed survey to be certain that none of the seawater pipes were corroded and liable to fail suddenly. The engineer/deckhand spent a good deal of his own time learning about Chloe T from the previous operators. While this was commendable, unfortunately, key features were missed. These included: the existence of any supplementary
bilge
alarms; proving the reliability of the
bilge
alarm sensor, which was mounted close to the
main engine
flywheel
; and, checking what other methods could be used to
pump
out the
engine room
bilges in an emergency. Each of these issues, while crucial in the accident, were not necessary to Chloe T’s normal operation. It is likely that they were considered to have a lower priority – useful things to know once the basic operation of the vessel had been mastered. 4.5.3 Operation The last time the
bilge
alarm sensor in the
engine room
was proved to have worked was over a week before the accident. It was quite likely that it became fouled again and did not work during the accident.
Bilge
alarm sensors need to be checked regularly. Certainly before the beginning of each
fishing
trip and, ideally, every day at
sea
. The engineer/deckhand had a good working routine for checking the
running
machinery
. However, this was focused on the normal operation of Chloe T. Far less attention was given to checking alarms or learning more about reconfiguring systems to cope with an emergency. 4.6 EFFECTIVENESS OF THE STATUTORY SURVEY REGIME The
MCA
publishes detailed requirements for the scope and conduct of statutory surveys and inspections on
fishing
vessels. These requirements were not met on Chloe T in a number of areas. 4.6.1 Scheduling of surveys and inspections The records of surveys for the
renewal
of Chloe T’s
UKFVC
in 2002, 2006 and 2011 were examined, as they were the most pertinent to this accident. In each case, there were delays in the process: 8 months in 2002, from February 2006 until February 2007 and from February to August 2011, which resulted in the vessel being issued with short-term certificates. This was contrary to the requirements of the 15-24m Code, which stated that an extension of up to 2 months could be granted in exceptional circumstances. There were no records which showed that any interim inspections had been conducted between the
renewal
surveys in 2002 and 2006, and between 2006 and 2011.
SIAS
records showed that inspections had been conducted in 2007 and 2008 at around the time when an interim inspection would have been expected. However,
both these were recorded as ‘targeted’ inspections, and it is impossible to determine from the records whether they met the requirements of an interim inspection. It is therefore possible that the vessel did not have interim inspections as required and that, in accordance with the statement in
MSIS
27, the
UKFVC
was invalid from February 2009 until April 2011. Chloe T did, however, have a valid
UKFVC
at the time of the accident. If the intermediate inspections were not done, as the
MCA
’s records suggest, Chloe T would have operated without a valid
UKFVC
for about 12 months from February 2005 to February 2006, and again for 2 years from February 2009 to February 2011. Apart from being contrary to the regulations, it is unlikely that Chloe T received the level of survey and inspection that is stated in the
MCA
’s documentation as being required over a sustained period. While the 15-24m Code makes it clear that it is the owner’s responsibility to present his vessel for survey, there was no evidence of the
MCA
having taken action to detain the vessel as stated in
MSIS
27. Consequently, it must be concluded that the
MCA
’s surveyors either did not know that surveys and inspections of Chloe T were overdue, or were willing to tolerate the situation. 4.6.2 Scope of surveys and compliance with standards The
MCA
has set out an extensive scope for the surveys and inspections of
fishing
vessels. The standard is broadly equivalent to what would be done on a larger
. However, there was insufficient evidence to show that the whole scope had been applied. Of most relevance to this accident were the requirements for seawater systems. This included requirements and guidance, in five different
MCA
documents, for: • Systematic examination of seawater system pipework. • Ensuring that seawater inlet and
discharge
valves are operable from a
position
above
engine room
floor plates. Meeting the requirements relating to the operation of seawater valves and inspection of seawater system pipework were potentially challenging. Seawater valves Chloe T’s seawater inlet and
discharge
valves were not all easily operable from above the
engine room
floor plates. The engineer/deckhand was unable to close the
main engine
cooling seawater inlet
valve
because it was covered by the rising floodwater, and he set about removing floor plates to improve access. The floodwater was at about the level of the floor plates at this time, so it can be concluded that the
valve
was not accessible as stated in the 15-24m Code,
MSIS
23,
MSIS
27, MSF 5550 or
MGN
165. It was not possible to determine the precise reason for this. There was no evidence of this issue being addressed by an exemption, and Chloe T had been surveyed and inspected by a number of different
MCA
staff between1989 and the accident. The possibility of this requirement being simply overlooked is therefore unlikely. Moving the
main engine
cooling seawater valves to more accessible positions would have been a substantial job. New lengths of pipe would have been needed at the very least, perhaps with venting and priming
arrangements to make sure the flow of water was not disrupted. It is highly likely that fitting all this in between the existing
machinery
would have been technically challenging and expensive. An alternative method, recommended by the
MCA
, could have been to fit a remote operating device to the seawater inlet
valve
. In its simplest form, this could have been an extended spindle (perhaps a metre long) connected to a secondary
valve
handle. However, extended spindles can also be difficult to fit; the engineer/ deckhand described how he would have had to crawl into a corner of the
engine room
to reach the seawater inlet
valve
, the height in this part of the
engine room
was restricted by the
accommodation
above. It is easy to imagine how an extended spindle might not be ideal in such a location. It was evident that none of Chloe T’s operators had chosen to make the seawater inlet valves more accessible and that they had never been required to do so by surveyors. In the absence of any evidence to the contrary, it must be concluded that the most obvious reason for this was that the requirement was considered to be too difficult to achieve, and the case for making the
was never made strongly enough. Seawater pipework Removing lengths of pipe from the
bilge
of a vessel of Chloe T’s style of
construction
is not an easy task and would only be done for a compelling reason or to deal with a known problem. Surveying the pipes in-situ would be equally difficult and would provide very limited information about their condition. The recommendation for the ‘liberal use of hammer testing’ is questionable. There is a real chance in an older boat, of the
surveyor
breaching a pipe, leading to uncontrollable
flooding
if this is done while the vessel is afloat. While theoretically sound, the advice to pressure test seawater systems is extremely difficult to achieve in practice. Apart from the need to supply appropriate equipment and fittings to conduct a test, there is a significant problem in applying the recommended pressure of 3 bar safely; there is a risk of damaging equipment – particularly ageing heat exchangers – or of fittings coming apart under pressure (3 bar pressure is roughly equivalent to the pressure exerted by seawater at a depth of 30m – 10 times Chloe T’s
draught
). However, the most likely outcome is that the pressure cannot be maintained and that the
surveyor
is then confronted with the challenge of determining whether the leak is from the system, the test equipment, or both. The
surveyor
cannot afford to spend all his time on any given vessel looking at just one system. It seems unlikely that
fishing vessel
owners would have a systematic pipework inspection plan (of the sort kept by
societies for larger vessels). Certainly there was no evidence of such a plan on Chloe T. Consequently, the
surveyor
is placed in the unenviable
position
of being obliged to reach a judgment without having enough time or information to make a considered decision. 4.6.3 Record keeping The
MCA
’s record keeping system is effectively spread over three systems: the official CM files, the
SIAS
database, and local paper and computer records. No system satisfies all the requirements on its own, and the quality of the interface
between each is solely dependent on individual members of staff. The system is extremely vulnerable to errors, oversight and mistakes. This was evident in all the paperwork examined during the
of this investigation. There were several examples of the survey forms not being fully completed: there were no photographs or diagrams, descriptions of equipment were incomplete, and the results of tests were not recorded. Of greatest concern, however, was that a CM file on the vessel’s
machinery
had never been created. The lack of a file to record the results of
machinery
surveys is incompatible with the scope of the
machinery
surveys described in
MSIS
27 and elsewhere. The result is that the
MCA
’s records of the
machinery
fitted to Chloe T, its operation and condition are incomplete. While this was partially compensated by local working files and informal notes from the vessel’s owner, the
MCA
and owner denied themselves a significant opportunity to monitor the vessel’s condition. A serious failure was therefore far more likely to occur. It is possible that the targeted inspections on Chloe T in 2007 and 2008, which were recorded on
SIAS
, could have been considered as being the intermediate inspections required to validate the
UKFVC
. However, unless this is specifically recorded, there will always be some doubt about their status and, therefore, the validity of the
UKFVC
. 4.6.4 Exemptions Chloe T had been granted an exemption from the 1975 Rules regarding the performance of the
bilge
pumping system. This exemption was extended at each
renewal
survey, simply by the owner and
surveyor
highlighting the exemptions they wanted from a pre-prepared
list
of ‘standard’ exemptions. This was much the same from survey to survey (apart from the fitting of a
fire detection system
). When the validity of the exemption given for
bilge
pumping was examined as part of this investigation, it was found that there was not enough information in the CM file to be able to determine whether the exemption was valid, or not. When the information from the CM file was combined with other sources (including the purchase survey), it was considered likely that the
bilge
pumping system on Chloe T exceeded the requirements of the 1975 Rules. It is quite possible that there was no need for an exemption, and that one had been given, on a safety critical system, for over 10 years without challenge. 4.6.5 Summary Chloe T was not surveyed in accordance with the applicable requirements or guidance. As a result, it is likely that the vessel’s
UKFVC
was invalid at times, and that the condition of safety critical systems was not checked as it should have been. Requirements for
valve
handles to be accessible were not enforced and the
MCA
’s records were not completed in accordance with its own instructions. It is impossible to know how much the shortcomings in the survey process contributed to the failure of the pipework.
MSIS
23 emphasises that it is the owner’s responsibility to demonstrate that pipework is in a satisfactory condition, and
MSIS
27 states that owners should agree a 5-year cycle with
MCA
surveyors for surveying
machinery
systems. However, an accessible handle to close the
main engine
seawater cooling inlet
valve
might have made a significant difference to the outcome of this accident. The
MCA
’s surveyors face an extremely challenging task; they are presented with a very large scope of work to cover, and guidance that is, in parts, not credible. The systems for recording the results of surveys and inspections are inefficient and vulnerable to error. The records did not contain enough detail to determine whether exemptions from earlier rules should continue to apply, or that the vessel’s condition was being systematically checked. It is inevitable that mistakes in the documentation were made and highly likely that parts of the vessel were not surveyed in as much detail or as frequently as intended.
SECTION 5 – AUDACIOUS/CHLOE T SIMILAR ACCIDENTS 5.1
FLOODING
AND
FOUNDERING
OF FV VELLEE, 6 AUGUST 2011 The 19.8m
trawler
Vellee suffered a
flooded
engine room
and
foundered
while on passage. The
MAIB
investigation report, No 1/2012, found that the
crew
discovered flood water in the
engine room
, above gearbox level, but were unable to access the
sea
inlet valves as they were underwater. The report concluded that it was probable that the source of water ingress was as a result of a catastrophic failure of seawater piping or associated fittings arising from advanced electrolytic corrosion. 5.2 ANALYSIS OF Uk
FISHING VESSEL
SAFETY 1992 - 2006 In November 2008 the
MAIB
published a
fishing
safety study which analysed the trends from UK
fishing vessel
accidents, losses, fatalities and injuries for the period 1992 -2006. The study found that in the 15m–24m category 85 vessels were lost due to
flooding
/
foundering
. Progressive
flooding
and the failure of the
main engine
cooling systems were recorded in the
MAIB
database as being the most common causes of
flooding
incidents.
SECTION 6 – DISCUSSION 6.1
FLOODING
The precise reasons for the
flooding
of Audacious and Chloe T are not known. However, analysis of the circumstances of the accidents and the histories of each vessel strongly indicates that both floods were caused by seawater
cooling system
pipework failing due to undetected corrosion. While the rate and extent of corrosion in seawater pipes can be influenced by several different methods, some corrosion is inevitable. 6.2 PREVENTION 6.2.1 Pipework deterioration The only way to prevent such failures is to have a methodical system for checking the condition of seawater pipework and to replace it before it fails. Pipework should normally be expected to deteriorate at a fairly constant rate; however, changes in electrical potential (due to earth faults, missing galvanic isolation, or lost anodes) and other metallurgical factors (such as
a vessel in polluted or stagnant water) can cause dramatic changes. Certain sections of pipework, where flow velocities are highest, will also be more vulnerable to corrosion damage than others. It is impractical to predict the effect of these factors precisely – regular inspections are essential. 6.2.2 Survey and inspection There was evidence that some pipework was inspected and replaced on both Audacious and Chloe T from time to time. However, the accidents demonstrate that this was not sufficient. The statutory requirements for the survey and inspection of
fishing
vessels are extensive. The owners of vessels also have considerable responsibilities for managing maintenance and arranging surveys. It is hard to imagine that both these accidents could have occurred if all the requirements previously described in this report had been met. It must therefore be concluded that shortcomings in the maintenance, survey and inspection of Audacious and Chloe T allowed deterioration in their seawater systems to go undetected. There was evidence from both vessels to support this conclusion. Missing intermediate inspections and delays in the
renewal
survey process were noted in both cases; it is unlikely that either vessel received the level of oversight that was intended in the
MCA
’s instructions to its surveyors. Neither vessel had the required maintenance plans, nor evidence of a systematic pipework inspection or replacement programme being agreed with
MCA
surveyors. The files to
this sort of information (CM file series for
machinery
) had never been created. It is impossible to know how much the shortcomings in the survey process contributed to the failure of the pipework.
MSIS
23 emphasises that it is the owner’s responsibility to demonstrate that pipework is in a satisfactory condition, and
MSIS
27 states that owners should agree a 5-year cycle with
MCA
surveyors for surveying
machinery
systems. There was no evidence of this taking place in either the Audacious or Chloe T cases.
It is also extremely unlikely that the survey requirements could ever be rigorously and effectively applied. Both hammer and pressure testing carried some risk, and neither were likely to be wholly conclusive test methods. It is simply not credible that all the pipes could be adequately tested in this way, particularly in a vessel of the age and style of Chloe T. Finally, the records of maintenance and surveys were incomplete. This made it impossible for anyone to know which pipes had been checked, when or by what method. Records did not show where important equipment was located or if exemptions from the rules should continue to apply. Given all these factors, it is hardly surprising that the seawater pipework in Audacious and Chloe T could fail so suddenly. Unless every part of the pipework system is systematically checked and its condition recorded, there will always be a risk of it failing due to undetected corrosion. 6.3 DETECTION 6.3.1 Early warning In both cases, the
crew
were alerted to
flooding
in the
engine room
by some other means than their
bilge
alarm; the unexpected behaviour of the
system in Audacious and the
fire
alarm in Chloe T. The result was the same in both accidents – by the time the
crew
were aware of the problem, it was too late to take action.
Bilge
alarms should have given the
crew
ample warning of
flooding
; these failed either because the signal was not heard, or because the alarm did not work when it was needed most. 6.3.2 working practices The
on Audacious should have been in the wheelhouse at the time of the accident and ought to have been able to respond to the alarm immediately. The
MAIB
has investigated many cases where watchkeepers have not been present, and this is a consistent factor in
fishing
and smaller
merchant vessel
accidents. However, a
bilge
alarm might also activate when a vessel is alongside, perhaps while
crew
are sleeping on board. These possibilities strongly support a requirement for emergency alarms to be audible throughout a vessel, and of being capable of rousing a sleeping crewman in sufficient time for him to be able to find, and react to, the problem before it has developed into a major emergency13. One of the
bilge
alarm sensors in Chloe T’s
engine room
had been faulty, but was thought to have been working properly before the accident. However, it was not tested regularly enough for there to be much confidence that it continued to work reliably. Most alarm systems are likely to fail at some point and the only way to gain confidence and familiarity is to test the alarm regularly. This should mean before sailing, and daily when at
sea
. 13 The
MCA
has previously accepted a recommendation from the
MAIB
to ‘Introduce a mandatory requirement, for all vessels greater than 24m length and less than 500 gross tons, for the fitting of
bilge
alarms in
engine
rooms and other substantial compartments that could threaten the vessel’s
buoyancy
and
stability
if
flooded
. These, and any other emergency alarms should sound in all
accommodation
spaces when the central control station is unmanned. In addition to functioning in the vessel’s normal operational modes, alarms should be capable of operating when main power supplies are shut down, and be able to
sleeping
crew
in sufficient time for them to react appropriately.’ following the
flooding
and
foundering
of the grab hopper
Abigail H in the
Port
of Heysham on 2 November 2008. Report No 15/2009.
The
crew
on board both Audacious and Chloe T had regular routines for checking on their
engine
rooms and
running
machinery
. While this is good practice and may help in detecting leaks at an early stage, there is no guarantee that the
will be manned exactly when a problem occurs. An efficient alarm is essential. 6.4 EMERGENCY REACTION 6.4.1 Immediate response to
flooding
The crews of both vessels knew to try and shut their
main engine
seawater cooling inlet valves. Neither was able to do so because the layout of the
engine
rooms meant that the
valve
handles were quickly submerged. There is ample guidance, published over many years, which advises that
valve
handles should be extended or otherwise capable of being remotely closed in a
flooding
emergency. However, this was not done either voluntarily, or through enforcement of a statutory requirement. It is quite likely that this single issue allowed the
flooding
to cause the
of both vessels – seawater inlet valves must be accessible so that they can be closed if an
engine room
begins to flood. 6.4.2 Pumping The fixed pumps were not able to cope with the rate of
flooding
. A powerful, independently-powered salvage
pump
might well have given the
crew
more time to react, or even contained the flood. However, other investigations conducted by the MAIB14 have illustrated the fatal, unintended consequences of using such pumps. Salvage pumps on board
fishing
vessels are often
powered and, if used in a
, their exhaust can cause
poisoning. It is easy to imagine, if similar pumps had been used in Audacious or Chloe T, that they would have been set up in the
engine
rooms (or the
accommodation
above) and their exhaust fumes could well have caused further tragedy. 6.4.3
Stability
Audacious’s and Chloe T’s margins of
stability
were quickly reduced by the
flooding
. In both cases, this was due to the effect of the increased
free surface
moment as water
flooded
across the
breadth
of the
engine room
. The margin of
stability
was further eroded as the nets were hauled in. Fortunately this was quickly appreciated by the
skipper
, and the nets were run off to prevent further problems. The reductions in
stability
occurred very soon after the
flooding
was discovered and put further pressure on the crews. It is unlikely that any of those on board knew whether their vessels could remain upright or stay afloat if the
engine
rooms
flooded
, despite the requirement for
stability
books to be carried. Chloe T remained afloat for several hours after the
crew
had abandoned it, and it is possible that Audacious could also have stayed afloat for longer if
watertight
doors on the vessel had been shut. Skippers need to understand the effect of major
flooding
on their vessels in order to help them make the best decisions regarding abandoning in an emergency. 14 e.g.
MAIB
Report on the investigation of the fatal accident to a crewman on board the
fishing vessel
Starlight Rays 126nm NNE of Aberdeen on 25 August 2011. Report No 15/2012.
6.4.4
Abandonment
Chloe T’s
crew
had completed their mandatory training (including
sea
survival), practised regular emergency drills and abandoned their vessel in a calm and efficient manner. They minimised the risk to themselves and, by making good use of their radio and
EPIRB
, made it as easy as they could for the emergency services and other seafarers to help them. The
crew
of Audacious were less well prepared. Although the
EPIRB
was taken to the
liferaft
, the
crew
put themselves at unnecessary risk by returning to their cabins to collect personal effects and by gathering valuable
trawl
sensors.
Lifejackets
and immersion suits were ignored and one of the liferafts was lost because it was not secured properly. It was fortunate that none of these issues affected the safe rescue of the
crew
. The problems that were encountered underline the importance of all
crew
completing the appropriate training and practising regular drills to help them react properly in an emergency.
SECTION 7 – SAFETY ISSUES 7.1 CAUSE OF
FLOODING
1. Although it was not possible to determine the precise causes of the
flooding
in Audacious and Chloe T, it was concluded that the most likely reason in both cases was a failure of the
main engine
seawater cooling pipework. [2.4.1 Audacious, 4.2 Chloe T] 2. It is impractical to predict the rate of corrosion damage in seawater pipework – regular inspections are essential. [6.2.1] 3. It must be concluded that shortcomings in the maintenance, survey and inspection of Audacious and Chloe T allowed deterioration in their seawater systems to go undetected. [6.2.2] 7.2 ASSESSING THE CONDTION OF SEAwATER PIPEwORk 1. Neither Audacious nor Chloe T had any evidence of the required maintenance plans or a systematic programme of pipework inspection and replacement. [6.2.2] 7.3 DETECTING
FLOODING
1. In both cases, the
crew
were alerted to
flooding
in the
engine room
by means other than their
bilge
alarm.
Bilge
alarms should have given the
crew
ample warning of
flooding
; these failed either because the signal was not heard, or because the alarm did not work when it was needed most. [6.3.1] 2.
Bilge
alarms should be tested before sailing and, ideally, daily when at
sea
so that confidence can be assured that the alarm will work in an emergency. There is a strong case to support alarms being audible throughout the vessel and being capable of rousing a sleeping crewman in sufficient time for him to be able to react appropriately. [6.3.2] 7.4 RESPONDING TO
FLOODING
EMERGENCIES 1.
Watertight
doors are provided to improve a vessel’s survivability if
flooding
occurs. The
watertight
doors on board Audacious did little to help the situation because they were not routinely shut. [2.4.4 Audacious] 2. The
general service pump
was not reconfigured to help
pump
out water from Chloe T’s
engine room
because no-one on board knew how to do this. It is possible that the flood might have been contained by using both the
bilge
and general service pumps together. [4.4.1 Chloe T] 3. The crews of both Audacious and Chloe T knew to try and shut their seawater inlet valves to reduce the rate of
flooding
. Neither was able to do so because the layout of the
engine
rooms meant that the
valve
handles were quickly submerged. Seawater inlet valves must be accessible so that they can be closed if an
engine room
begins to flood. [6.4.1]
4. The vessels’ fixed pumps were not able to cope with the rate of
flooding
. An independently powered salvage
pump
might have assisted. However, these must be used with extreme care if they are powered by a petrol or
diesel engine
to avoid the exhaust fumes causing
carbon monoxide
poisoning. [6.4.2] 5.
Fishing vessel
skippers need to understand the effects of major
flooding
on board their vessels in order to help them make the best decisions regarding abandoning in an emergency. [6.4.3] 6. The majority of Audacious’s
crew
had not completed safety awareness training. They were fortunate that they were able to board the
liferaft
and be rescued without entering the water; in different circumstances, their chances of survival, without
lifejackets
and survival suits, could have been severely reduced. [2.5] 7. The differences in the way Audacious and Chloe T were abandoned underline the importance of all
crew
completing the appropriate training and practising regular drills to help them react properly in an emergency. [6.4.4] 7.5 EFFECTIVENESS OF STATUTORY SURVEYS AND INSPECTIONS 1. The 15-24m Code makes it clear that it is the owner’s responsibility to present his vessel for surveys and intermediate inspections. The owner and
skipper
also have more practical responsibilities to ensure that the vessel is seaworthy and can be operated safely. [2.6, 4.5.1] 2. Missing intermediate inspections and delays in the
renewal
survey process were noted in both cases; it is unlikely that either vessel received the level of oversight that was intended in the
MCA
’s instructions to its surveyors. [6.2.2] 3. It is extremely unlikely that the scope of the statutory survey requirements could ever be rigorously and effectively applied. [6.2.2] 4. The survey and inspection records were incomplete and made it impossible for anyone to routinely know which pipes had been checked, when or by what method. [6.2.2] 5. Records were incomplete and did not show where important equipment was located or if exemptions from the rules should continue to apply. [6.2.2] 6. Unless every part of the pipework system is systematically checked and its condition recorded, there will always be a risk of it failing due to undetected corrosion. [6.2.2]
SECTION 8 – ACTION TAkEN 8.1 ACTIONS TAkEN BY OTHER ORGANISATIONS The
MCA
has: • Issued ‘
Surveyor
Advice Note’ (SAN) 29 titled “Surveying Marine
Engine
Cooling and Salt Water Piping Systems in Ships” dated 22 March 2013 updating the advice available to surveyors on surveying pipework in
fishing
vessels. Langdon and Philip has: • Required
crew
on its other vessels to ensure that they test all
bilge
alarms before departure, and each day when at
sea
. • Confirmed that its other vessels have much simpler seawater systems than those on Chloe T and that the inlet valves are more accessible in the event of seawater system failure.
SECTION 9 – RECOMMENDATIONS The
Maritime and Coastguard Agency
is recommended to: 2013/249 Review the conduct of its surveys and inspections of
fishing
vessels in order to ensure that: • The scope is credible and that it can be achieved in practice. • The whole scope is routinely applied. • Records are accurate and complete. 2013/250 Implement a robust system to manage the scheduling of surveys and inspections on
fishing
vessels. Such a system should be capable of readily identifying vessels that are overdue for any surveys or inspections. The Deveron
Fishing
Company (owner of Audacious) is recommended to: 2013/251 Improve the safety of any other
fishing
vessels it operates by ensuring that: • Intermediate inspections are conducted. •
Crew
have completed mandatory training. • A continuous watch is maintained in the wheelhouse. The Scottish Fishermen’s Federation, the National Federation of Fishermen’s Organisations and the Northern Ireland Fish Producers Organisation Limited are recommended to: 2013/252 Promulgate the lessons learned from these accidents to their members. Particular emphasis should be given to the need for
fishing vessel
operators to thoroughly inspect seawater pipework to identify corrosion/erosion at an early stage.
Marine Accident Investigation Branch
December 2013 Safety recommendations shall in no case create a presumption of blame or liability
Marine Accident Report
한국어 번역 · 모델 · 검수 전
2절 분석
2.1 목적
분석의 목적은 사고의 기여 원인과 상황을 확인하여 장래에 유사한 사고가 발생하는 것을 방지하기 위한 권고의 기초를 마련하는 것이다.
2.2 요약
침몰 위치가 외딴 곳이어서 Audacious호를 조사하는 것은 불가능하였다. 입수 가능한 증거를 분석한 결과, 선박이 기관실로 빠르게 물이 유입되어 침몰하였으며 이 유입이 처음에는 감지되지 않았음이 나타났다. 물이 유입된 속도는 해수 냉각 배관의 파손이 원인이었음을 나타낸다. 선박이 고의로 침몰되었음을 시사하는 증거는 없었다.
2.3 항해당직/경계
선장은 주기관의 음색이 바뀐 것을 알아차리기 전 30분 동안 여러 차례 조타실을 비워 두었다. 그는 그물 수리 진행 상황을 확인하려고 갑판으로 나갔고 선원들을 위한 식사를 준비하고 조리하며 조리실에서도 시간을 보냈다. COLREGS 제5규칙은 모든 선박이 항상 적절한 경계를 유지하여야 한다고 요구한다. MGN 313(F)는 경계 임무를 방해할 수 있는 다른 업무를 수행해서는 안 된다고 규정한다. 이 MGN은 어선이 연루된 여러 충돌, 좌초 및 아차사고 이후에 발행되었으며, 그것들은 모두 불량한 항해당직의 결과로 발생하였다. 이 사고는 장비와 경보를 감시하고 적절한 경계를 유지하기 위해 조타실에 항상 사람이 있도록 하는 것의 중요성을 다시 일깨운다. 조타실에서 계속적인 당직이 이루어지지 않았으므로 기관실 빌지 경보의 최초 작동은 알아차려지지 않았고, 선원들이 침수를 알게 되었을 때에는 이미 선박을 구하기에 너무 늦었다.
2.4 기관실 침수/복원성
2.4.1 침수의 원천과 침수율
기관사가 기관실을 점검하여 빌지가 말라 있음을 확인한 때부터 다시 돌아와 물이 기관 상단 가까이 차 있는 것을 발견한 때까지의 시간은 약 30분이었다. MDI가 한 계산에 따르면 이 기간에 약 32톤의 물이 기관실로 들어왔다. 1542시경 선장은 구명뗏목으로 가는 길에 기관실 탈출 해치를 내려다보고 탈출 사다리 맨 아래에서 약 0.5m 높이에 물이 있는 것을 보았다. 이 관찰에 기초하여 MDI는 이 시점까지 추가로 40톤이 기관실에 들어왔다고 계산하였다. 두 관찰 사이의 시간 대부분 동안 시간당 25톤의 빌지 펌프가 물을 배출하고 있었으므로, 이 시점의 실제 유입 속도는 구역 안에서 계산된 용량보다 컸을 것이다.
두 관찰 사이의 침수율은 시간당 약 160톤으로 계산되었다. 유량 계산(부속서 H)은 수선 아래에 있는 해수 냉각 배관의 위치를 나타내는 수두 4m를 가정하면, 물이 직경 최소 100mm의 구멍을 통해 기관실로 들어오고 있었음이 틀림없음을 보여 준다. 2003년과 2008년에 실시한 선체 강재 두께 계측은 부식률이 과도하지 않았음을 보여 주었으므로, 선박의 선체 외판이 파손되었다고 의심할 이유는 없었다. 따라서 침수가 주 해수 흡입 배관 또는 주기관 해수 냉각 계통 중 어느 하나의 파손으로 인해 발생하였을 가능성이 높다고 결론짓는 것이 합리적이다.
2.4.2 복원성
MDI는 기관실에 들어온 물이 기관 양쪽의 청수 탱크를 덮자 자유표면 모멘트(FSM)가 약 45.13tm에서 229.17tm으로 증가하였음을 확인하였다. 이로 인해 선박은 (가라앉고는 있었지만) 안정된 상태에서 불안정한 상태가 되었다. FSM의 이 매우 크고 갑작스러운 증가와 그에 따른 복원성 저하는 웰형 기관실 설계가 침수에 취약함을 보여 준다(부속서 B). 비교적 적은 양의 물이 주기관을 순식간에 압도하여 선박을 무력화할 수 있다. 기상이 그렇게 잔잔하지 않았다면 이러한 갑작스러운 복원성 상실이 선박의 전복으로 이어졌을 수 있다. 선원들은 기관실이 침수되었을 때 선박이 복원성을 잃을 수 있는 속도를 인식하지 못하였고, 이후 전개되는 비상 상황에 대응할 때 취한 조치들도 이 위험을 고려하지 않았다.
2.4.3 연장 스핀들
기관사가 기관실로 돌아왔을 때 해수 흡입 밸브는 1미터 넘게 물속에 있어 접근할 수 없었으므로 그는 밸브를 닫아 추가 침수를 막을 수 없었다. MGN 165(F)는 어선의 침수를 방지하기 위한 조치에 대한 지침을 제공한다. 이는 해수 밸브를 쉽고 빠르게 닫을 수 있는 위치에 둘 것을 권고하며, 플로어 플레이트를 제거하지 않고도 밸브를 닫을 수 있도록 '필요한 경우' 연장 스핀들을 설치할 것을 권고한다. Audacious호의 해수 밸브는 플로어 플레이트 높이 위에 있었지만, 이 사고는 급속하거나 감지되지 않은 침수의 경우 이에 접근하는 것이 순식간에 불가능해질 수 있음을 보여 준다. 밸브에 기관 상단과 같은 높이까지 오는 연장 스핀들이 설치되어 있었다면 기관사가 밸브를 잠가 물의 유입을 막을 수 있었을 것이다. MGN 165(F)의 지침이 해수 흡입 밸브에 접근할 수 있어야 할 필요성을 확인하고 있으나, 침수 속도가 빠르고 웰형 기관실에서 발생하는 경우에는 이것으로 충분하지 않을 수 있다. 해수 흡입 밸브를 닫을 수 있도록 하려면 더 긴 연장 스핀들이 필요하였다.
2.4.4 수밀문
기관실과 조타기실/작업실 사이의 수밀문은 계속 열려 있었고 '항해 중 닫아 둘 것(closed at sea)'임을 나타내는 표지가 붙어 있지 않았다. 수밀문을 항해 중에 닫아 두어야 하고 그에 따라 표지를 붙여야 한다는 요건은 MCA가 법정 검사 중에 지적한 바 있었으나 이행되지 않았다. 그 결과 Audacious호 전체에 물이 더 빠르게 침수될 수 있었고 선원들이 퇴선할 수 있는 시간이 줄었다. 수밀문은 침수 시 선박의 생존 가능성을 높이기 위해 설계되었으나, 선박이 항해 중일 때 일상적으로 닫혀 있어야만 효과가 있다.
2.5 퇴선
선원들은 선실로 돌아가 구명조끼를 가져온 다음 구명뗏목을 준비하라는 지시를 받았다. 선원들은 선실로 돌아갔으나 개인 소지품만 챙겼고 이후 구명조끼를 착용하지 않은 채 구명뗏목에 탔다. 선실 가까이 있는 사물함에 보관되어 있던 생존복은 퇴선 중에 챙기지 않았으나, 값비싼 트롤 센서 몇 개는 조타실에서 가져와 구명뗏목에 실었다. 대다수 선원은 1995년 어선(안전 훈련) 규칙(Fishing Vessels (Safety Training) Regulations 1995)의 요건에 반하여 안전 인식 훈련을 이수하지 않았다. 선원들은 물에 들어가지 않고 퇴선하여 구조될 수 있었으므로 운이 좋았다. 다른 상황이었다면 구명조끼와 생존복을 착용하지 않은 상태에서 이들의 생존 가능성이 크게 줄어들 수 있었다. 선주는 선원들이 필요한 자격을 갖추도록 보장하지 않았고, 이 누락은 MCA의 선박 검사나 점검에서 발견되지 않았다.
2.6 UKFVC – 검사와 점검의 일정 수립
CM 파일과 SIAS 기록으로부터, Audacious호가 2003년 5월부터 8월까지 3개월 동안 UKFVC를 가지고 있지 않았음이 분명하였다. 그 후 이 상황은 모두 2003년 3월 27일의 같은 검사 일자에 근거한 일련의 단기 증서 세 개를 발급함으로써 해결된 것으로 보인다. 이는 거의 확실하게 선박의 복원성 자료집 작성 및 승인이 지연되었기 때문이다. 정식 기간 증서는 2004년 4월에야 발급되었으며 이 역시 3월 27일 검사에 기초한 것이었다. 이 증서는 2008년 12월 31일까지 유효하였는데, 이때는 마지막 갱신 검사로부터 5년 9개월이 되는 시점이었을 것이다. 이는 선박이 '5년을 넘지 않는 간격으로 갱신 검사'를 받도록 한 15-24m 규약의 요건을 초과하는 것이었다.
표적 점검이 2004년 8월과 2006년 10월에 실시되었으나, 중간 점검은 2007년 7월 7일에야 완료되었으며 이는 7개월 늦은 것이었다. UKFVC의 유효성은 증서 발급 후 24개월 이상 36개월 이하 사이에 중간 점검이 실시되는지에 달려 있다. MCA의 지침은 유효한 UKFVC 없이 운항하는 선박이 즉시 억류될 수 있다고 분명하게 규정한다. 그러나 억류 기록은 없었으며, Audacious호가 이 기간에 유효한 UKFVC 없이 계속 운항하였을 가능성이 높다. Audacious호는 2008년 8월에 MCA의 검사를 받았고 2008년 12월에 2013년 12월까지 유효한 UKFVC가 발급되었다. Audacious호에 대해 중간 점검이 실시되지 않았으므로 UKFVC는 2011년 12월 31일 이후 유효하지 않았다고 결론지을 수밖에 없다.
15-24m 규약은 선박이 규약의 관련 규정에 따라 검사받도록 보장할 책임이 선주에게 있다고 규정한다. 이 선박은 2011년 7월에 만재흘수선 면제 증서 발급을 위해 MCA의 점검을 받았고, MCA 검사원은 점검 보고서(부속서 D)에 UKFVC 중간 점검이 2011년 말 이전에 있어야 한다고 기록하였다. 이러한 상기에도 불구하고 UKFVC에 대한 중간 점검은 실시되지 않았다. 그러나 중간 점검이 기한을 넘기면 선박을 억류하여야 한다고 검사원에게 지침을 내린 MCA의 지침에도 불구하고, Audacious호가 기한을 넘겼음을 식별할 메커니즘이 없었다. Audacious호의 선주와 MCA 사이의 불량한 관리와 의사소통으로 인해 선박은 요구되는 대로 점검을 받지 못하였고 UKFVC는 '무효가 되었다'. 이는 규정에 반하는 것이었으나, 실질적으로 훨씬 더 중대한 것은 선박의 물적 상태가 MCA가 제공하는 감독 체계 밖에 놓였다는 점이었다.
2.7 연례 자체 증명
15-24m 규약은 안전, 항해 및 구명 장비가 유효 기간 내에 있고 올바르게 작동하는지, 그리고 선원의 훈련과 자격증명이 유효한지 확인하기 위해 선박이 매년 자체 증명을 하도록 보장할 책임이 선주에게 있다고 규정한다. 일부 선원이 필수 어선 안전 훈련 과정을 이수하지 않았다는 사실은 선주의 연례 자체 증명 절차가 충분히 견고하지 않았음을 보여 준다.
2.8 검사원에 대한 MCA 지침
2.8.1 냉각수 배관 검사
MCA의 검사원 지도 지침 MSIS 27(5.7.6절)은 해수 배관을 정기 검사 때 '해머 시험을 적극적으로 사용하여' 철저히 점검하여야 한다고 규정한다. 또한 첫 갱신 검사 이후에는 '해수 계통에 3바(bar) 압력 시험을 실시하여야 한다'고 요구한다. 2003년 3월 UK FVC 갱신 검사에서 검사원은 '기관실 배관 해머 시험 실시'라고 기록하였다. 이것은 선박의 CM 파일에서 기관실 배관의 해머 시험을 언급한 유일한 기록이었으며, 해수 계통 배관에 압력 시험이 실시된 적이 있다는 기록은 없다.
Audacious호의 해수 냉각 배관을 검사하는 체계적인 계획이 없었고 상세한 기록도 없었으므로, 배관의 일부 구간이 점검되지 않았거나 교체되지 않았을 수 있었다. 따라서 사고 당시 일부는 원래의 것, 즉 13년 된 것이었을 수 있었다. 이는 MCA의 검사 및 점검 요건과 '검사원에 대한 지침'에 반하는 것이었다.
2.8.2 비망록
MCA가 검사 중에 검사원을 안내하기 위해 발행한 비망록 MSF 5550(부속서 E)에는 선박의 배관 상태에 대한 언급이 포함되어 있었으나 특정한 시험 방법은 언급하지 않았다. 비망록은 그 성격상 '검사원에 대한 지침'에 담긴 상세한 정보의 요약만을 담을 수 있지만, 이 문서에 해수 배관을 어떻게 시험하여야 하는지에 대한 상기 사항을 포함시키는 것이 도움이 될 것이다. 비망록에는 검사원이 검사 또는 점검의 범위에 무엇이 포함되었는지, 그리고 필요한 기준이 충족되었는지를 신속하게 기록할 수 있는 칸이 있었다. 이것들은 현재 문서로 보관되지 않으므로, 이후 검사를 안내하고 알려 줄 수 있는 유용한 배경 정보가 사라진다.
2.9 MCA의 기록 관리
MAIB 조사 중에 선박의 CM 파일과 SIAS 데이터베이스가 광범위하게 참조되었다. CM 파일에는 색인이 없었고 선박에 대해 실시된 여러 검사 보고서가 파일에서 누락되어 있었다. 파일의 불량한 구성 때문에 열람자는 선박의 UKFVC가 더 이상 유효하지 않다는 것을 쉽게 알아볼 수 없었다. SIAS에 보관된 선박의 검사 기록도 불완전하였으며, 선박에 대해 실시된 모든 검사가 데이터베이스에 기록된 것은 아니었다. Audacious호의 검사 및 점검에 관한 MCA의 기록은 불완전하였으며, MCA 직원이 선박 증서의 유효성이나 선박의 상태 또는 이력을 판단하기 어렵게 하였을 것이다.
어선 CHLOE T호의 침수 및 침몰 - 요약
2012년 9월 1일 Chloe T호는 통제할 수 없는 기관실 침수를 겪어 데번 볼트 헤드(Bolt Head) 남서쪽 17마일에서 침몰하였다. 선원들은 1545시경 기관실에 연기가 있음을 나타내는 화재 경보로 침수를 알게 되었다. 선원들은 즉시 조사하여 침수된 물이 주기관 플라이휠에서 터보차저 케이싱으로 튀어 증기로 변하는 것을 발견하였다. 기관실은 급속히 침수되었고 빌지 펌프는 감당하지 못하였으며, 선원들은 침수의 원천을 찾을 수 없었다. Chloe T호의 기관사/갑판원은 침수가 주기관 해수 냉각 계통의 파손 때문일 수 있다고 의심하였다. 그는 해수 흡입 밸브가 침수된 물에 금세 잠겨 이를 닫을 수 없었다. 선장은 Chloe T호를 구할 방법이 거의 없음을 알아차리고 선원들이 구명뗏목으로 퇴선하도록 조기에 결정하였다. 선원들은 모두 구명조끼를 착용하였고 Chloe T호에서 안전하고 효율적으로 퇴선하였다. 여러 선박이 선장의 "Mayday" 방송에 응답하였고 선원들은 수색구조 헬리콥터에 의해 구조되었다.
침수의 정확한 원인을 확인하는 것은 불가능하였으나, 부식으로 인한 주기관 해수 냉각 계통 배관의 파손이 원인이었을 가능성이 높다고 결론지었다. 배관이 규정이나 MCA의 검사 지침이 요구하는 대로 검사 또는 점검되었음을 보여 줄 만한 문서가 부족하였다. 비상 중에 기관실 빌지 경보가 작동하였음을 보여 주는 증거는 없었다. 경보 센서는 사고 몇 주 전에 결함이 있었으나 청소한 뒤 작동하는 것으로 확인되었다. 이후 다시 시험되지 않았고 완전히 신뢰할 수 있었을 가능성은 낮다고 판단되었다.
스코틀랜드 어민연맹(Scottish Fishermen’s Federation), 전국 어민단체연맹(National Federation of Fishermen’s Organisations) 및 북아일랜드 어류 생산자 기구(Northern Ireland Fish Producers Organisation)에 이 사고와 Audacious호 사고에서 얻은 교훈, 특히 어선 운영자가 해수 배관을 철저히 점검할 필요성을 회원들에게 알리도록 권고하였다. 선주가 취한 조치와 그의 다른 선박들의 기관 배치를 고려하여 선주에게는 추가 권고를 하지 않았다.
3절 사실 정보
3.1 CHLOE T호와 사고의 세부 사항
선박 세부 사항 선박명 Chloe T 기국 영국 선급 해당 없음 어선 번호 PZ 1186 선종 빔 트롤선 등록 선주 Langdon and Philip 관리 회사 Langdon and Philip 건조 강재 전장 26.44 등록 길이 23.55 총톤수 136 최소 안전 승무정원 해당 없음 허가된 화물 없음
항해 세부 사항 출항항 브릭섬(Brixham) 도착 예정항 브릭섬 항해 유형 단거리 – 국제 화물 정보 어류 승무원 6 해양사고 정보 일시 2012년 9월 1일 1545시 해양사고 또는 사건 유형 매우 심각한 해양사고 사고 장소 데번 볼트 헤드 남서쪽 17마일 선내 장소 선박 전체 부상자/사망자 없음 손상/환경 영향 선박 멸실 선박 운용 트롤 조업 항해 구간 항해 중 환경 주간, 양호한 시정, 풍력 4, 해상 상태 4 승선 인원 6
3.2 배경
Chloe T호는 1968년 네덜란드에서 빔 트롤선으로 건조되었다. 원래 이름은 Martha Lela호였으며 1989년에 영국으로 들어와 Angel Emiel호로 개명되었다. 이 선박은 2000년에 다시 매각되어 Chloe T호로 개명되었다. 사고 당시의 선주는 불과 몇 주 전인 2012년 8월 3일에 이 선박을 매입하였다. Chloe T호는 새 선주 아래에서 두 차례 성공적인 조업 항해를 마쳤으며, 사고는 세 번째 조업 항해 3일째에 발생하였다.
3.3 경위
3.3.1 매입과 숙지
Chloe T호는 2011년에 처음 매물로 나왔으나 매매가 합의되지 않았다. Langdon and Philip는 이미 브릭섬 항에서 빔 트롤선 여섯 척을 운영하고 있었고 Chloe T호를 선단에 추가하기로 결정하였다. 이 회사는 어선의 운용과 정비에 경험이 있는 기술 직원 팀을 두고 있었으며 자체적으로 매입 전 검사를 실시하였다. 매매는 2012년 8월 3일에 완료되었다. Langdon and Philip가 운영하는 다른 선박들은 여름철에 수리 기간 중이었고, 관리자는 단기적으로 Chloe T호를 운용할 수 있는 선원을 이들 선박에서 선발하였다. 또한 기관사/갑판원 한 명이 다른 어업 회사에서 Langdon and Philip에 합류하도록 초청되었다. 그는 이에 동의하였고, 합류하기 전에 주말 대부분을 Chloe T호의 이전 운영자들과 함께 보내며 선박의 기관에 대해 배웠다.
Chloe T호
3.3.2 준비와 조업
Chloe T호는 Langdon and Philip 소유로서의 첫 항해를 준비하며 새 예인 와이어(towing warp), 그물 및 기타 관련 어구를 갖추게 되었다. 기관사/갑판원에게는 선박의 효과적인 운용을 지원하기 위한 공구 일습과 예비 부품이 제공되었다. 기관사/갑판원은 선내 계통에 대한 이해를 높이기 위해 기관을 조사하는 과정을 시작하였다. 8월 21일이 시작되는 주 중 어느 시점에 기관사/갑판원은 주기관 좌현의 플라이휠 가까이에서 빌지 경보 센서를 발견하였다. 빌지 경보 센서는 먼지와 이물질로 오염되어 작동하지 않았다. 기관사/갑판원은 센서를 청소하고 경보가 작동함을 확인하였다. Chloe T호 어창의 빌지 경보 센서에서 여러 차례 오경보가 발생하였다. 기관사/갑판원은 고정 브래킷이 부러져 경보 센서가 빌지 더 깊은 곳으로 떨어지게 되었음을 알아냈다. 그는 경보 센서를 다시 고정하고 장치가 올바르게 작동하는지 점검하였다. 처음 두 차례 조업 항해는 성공적이었다고 보고되었다. 선박이나 기관에는 큰 문제가 없었으며 선원들은 어획량과 선박 운영비에 만족하였다.
3.3.3 마지막 항해
Chloe T호는 8월 30일 목요일에 브릭섬에서 출항하였다. 출항 직후 선박의 자동조타장치에 문제가 확인되었다. Chloe T호는 브릭섬 항으로 되돌아왔고 육상 기술팀이 문제를 바로잡았다. 선박은 곧 조업 어장으로의 3시간 항해를 위해 출항하였다. 기관사/갑판원은 오후/저녁 당직 중 1900-2000시의 1시간을 기관실에서 보내는 일과를 만들었다. 그는 이 시간에 연료 일일 탱크를 다시 채우고 유량을 보충하며 기관의 일반 점검을 하였다. 또한 기관실 빌지에 고인 물을 배출하였다. 소량의 물이 고여 있어 선박의 빌지 배수 계통으로 선외에 배출하였다고 보고되었다.
3.3.4 조업
Chloe T호의 선원들은 8월 31일 금요일 내내 조업하였다. 기관사/갑판원은 이른 저녁에 일상 점검을 하였다. 기관은 정상적으로 가동되고 있었고 빌지 수위에 뚜렷한 증가는 없었다. Chloe T호가 주로 게를 잡기 위해 사용되는 것은 아니었지만 일부가 그물에 잡혀 선박 선수 끝의 웨일백(whaleback) 아래 탱크에 보관되었다. 갑판 세척 매니폴드에서 나온 호스를 탱크에 넣어 신선한 해수를 공급하여 게를 좋은 상태로 유지하였다. 갑판 세척 계통은 기관실의 일반 용도 펌프로 공급되었다.
3.3.5 경보
9월 1일 토요일 1400시에 선장은 당직을 항해사에게 인계하고 쉬러 아래로 내려갔다. 잠들 수 없었던 선장은 1530-1535시경 조타실로 돌아왔다. 항해사는 계속 당직을 섰고 두 사람은 이야기를 나누었다. 약 10분 뒤인 1545시경 화재 감지 시스템의 경보가 작동하여 기관실에 연기가 있음을 나타냈다. 경보는 Chloe T호 전체에서 울렸고 기관사/갑판원은 식당에서 조타실로 와 무슨 일인지 물었다. 오경보일 가능성이 낮다고 판단한 기관사/갑판원은 조사하러 기관실로 갔다. 기관사/갑판원은 기관실에 상당한 양의 증기가 차 있음을 발견하였다. 빌지에 고인 침수된 물이 주기관 플라이휠에 의해 퍼 올려져 구역 안에 흩뿌려지고 있었다. 이 물이 플라이휠 위의 터보차저 케이싱에 떨어져 증기로 변하고 있었다. 선원 중 누구도 기관실 빌지 경보가 작동하는 것을 보거나 듣지 못하였다.
3.3.6 비상 조치
기관사/갑판원은 기관실 우현 후부 끝의 주 출입문을 통해 기관실에 들어갔다(그림 9). 그는 펌프가 어창 빌지 웰에서 물을 빨아들이게 하는 빌지 계통의 밸브를 닫고, 펌프가 기관실 빌지에서 물을 빨아들이게 하는 밸브를 열었다. 그런 다음 기관실 선수 쪽 격벽에 고정된 기동 패널로 빌지 펌프를 가동하였다. 선장은 화재 경보 표시가 기관실만을 가리키고 있음을 확인한 뒤 항해사에게 어구를 끌어올리기 시작하라고 지시하였다. 이어 선장은 기관사/갑판원을 따라 기관실로 들어갔다. 당직 중이던 갑판원은 침상에서 자고 있던 나머지 갑판원을 깨웠고 두 사람은 조타실에 집합하였다.
기관사/갑판원은 침수의 가장 가능성 높은 원인이 해수 배관 중 하나의 파손이라고 의심하였고 문제를 찾으려고 주기관 좌현 쪽으로 돌아갔다. 침수 속도는 상당하였으며, 기관사/갑판원은 이것이 가장 큰 직경의 배관인 주기관 해수 냉각 계통의 파손으로 인한 것이라고 생각하였다. 그러나 물은 이미 너무 깊어 어디에서 침수되는지 알 수 없었다. 침수의 원인을 시사하는 뚜렷한 물줄기나 다른 교란은 없었다. 기관사/갑판원은 보조 기관 계통의 해수 흡입구를 제어하는 밸브들을 지나, 주기관 해수 냉각 흡입 밸브와 스트레이너가 있는 기관실 좌현 후부 모서리로 이동하였다. 작은 접근 구멍이 있었으나 밸브 손잡이와 스트레이너는 기관실 플로어 플레이트 아래에 있었다. 주변의 플로어 플레이트 중 다수가 나사로 고정되어 있었고, 기관사/갑판원은 배관과 밸브 손잡이에 더 잘 접근하기 위해 이를 들어 올리려 하였다.
빌지 및 일반 용도 펌프 기동기 박스 냉동 압축기 연료 차단 밸브 조타기 펌프 빌지 펌프 작업대 트롤 회수 펌프 우현 보조 발전기 위 갑판에서 들어오는 입구 주기관 해수 냉각 계통 해수 흡입 밸브 스트레이너 박스 기어박스 냉각기 주기관 냉각기 플라이휠 기어박스 제어 패널 주기관 터보차저 주기관 냉각기 일일 연료 탱크 주기관 시동 공기 탱크 빌지 경보 센서 윤활유 윤활유 펌프 좌현 보조 발전기 보조 기관 해수 냉각 및 빌지 펌프 프라이밍 계통 유압 프라이밍 냉동 선수창(Forepeak) 어창 1 어창 2 기관실 빌지 흡입 밸브 상자 저장 탱크 선외 배출 밸브
그림 9: Chloe T호의 기관실 배치 - 선원 기억에 기초한 개략도원본 PDF 42쪽
수위는 계속 빠르게 올라 곧 데크 플레이트 높이에 이르렀다. 기관실 후부 위에 있는 선원 거주구역의 배치로 인해 주기관 해수 냉각 흡입 밸브 구역의 공간이 줄어들어 있었다(그림 10). 따라서 기관사/갑판원이 밸브에 닿으려면 침수된 물이 주위로 차오르는 상태에서 이 낮은 공간으로 기어 들어가야 하였다. 잠재적으로 위험한 이 구역에 머물지 않기로 결정한 기관사/갑판원은 주기관 해수 냉각 흡입 밸브에 닿으려는 시도를 포기하고 기관실 주 구역으로 물러났다.
3.3.7 악화
주기관 플라이휠에서 한동안 물이 튀고 있었고, 이 물보라와 뜨거운 기계와의 접촉으로 생긴 증기가 합쳐져 가동 중이던 (좌현) 발전기가 정지하였다. Chloe T호는 주 전원을 상실하였고 빌지 펌프와 일반 용도 펌프가 정지하였다. 기관사/갑판원은 기관실 우현 쪽으로 다시 이동하여 우현 발전기를 가동하였다. 전원이 복구되자 그는 빌지 펌프를 다시 가동하였다. 선장은 상황이 악화되고 있음을 보고 기관실을 나와 해안경비대에 VHF 무선 호출을 하기 위해 조타실로 돌아갔다. 거의 같은 시각에 어구가 해저에서 끌어올려지기 시작하였고 그 전체 무게가 선박의 양망 보(lifting beam)에 실렸다. Chloe T호는 서서히 횡요하기 시작하였고 선원들에게는 선박의 복원성 여유가 크게 줄어들었음이 분명하였다. 선장은 항해사에게 어구를 해저로 다시 내리라고 지시하였고, 항해사는 예인 와이어의 끝이 윈치 드럼에서 풀려나갈 때까지 윈치를 풀어 주었다.
1618시에 브릭섬 해상구조조정본부(MRCC)의 해안경비대 관제관들은 Chloe T호 선장이 선박이 '기관실에 물이 차고 있다'고 보고하는 VHF 호출을 한 것을 기록하였다. 2분 뒤 선박이 동력을 상실하였고 기관실 수위가 프로펠러 축 위로 올라왔다는 내용으로 일지가 갱신되었다. 선장은 또한 선원들이 구명조끼를 착용하였고 Chloe T호의 구명뗏목을 준비하고 있다고 보고하였다. 1622시에 해안경비대는 "Mayday" 메시지가 방송되었음을 기록하였다.
3.3.8 퇴선
기관실의 수위는 계속 올라갔고 우현 발전기는 물보라와 증기의 유입으로 정지하였다. 어구가 풀려나갔으므로 주기관이 구동하는 윈치에 동력을 공급할 필요가 더 이상 없었다. 기관사/갑판원은 주기관을 정지시키고 좌현 발전기를 다시 가동하였다. 그런 다음 빌지 펌프를 다시 가동하였다. 기관사/갑판원은 선장 및 선원들과 상황을 논의하기 위해 상갑판으로 올라왔다. 동시에 그는 빌지 펌프 배출구에서 물이 선외로 배출되고 있음을 확인할 수 있었다. 기관사/갑판원은 기관실로 돌아갔다. 이때에는 물이 허리 깊이까지 찼으며 10분 동안 약 6인치 올라온 것으로 보고되었다. 침수 원인에 대한 징후는 여전히 없었다. Chloe T호에 설치된 비상용 수동 빌지 펌프는 선원들이 큰 도움이 되지 않는다고 생각하였고, MCA9가 권고한 휴대용 독립 동력 구난 펌프는 9 MCA는 상선 고시(MSN) 1770F '전장(LOA) 15미터부터 등록 길이(RL) 24미터 미만 어선의 건조 및 사용을 위한 어선 안전작업 실무규약'과 해사지침 고시(MGN) 165(어선) '침수의 위험' 모두에서, 독립 동력 구난 펌프를 어선에 비치하도록 권고한다.
기관실 거주구역 그림 11: Chloe T호 — 일반 배치도 아직 구입되지 않은 상태였다. 마찬가지로 기관사/갑판원은 일반 용도 펌프가 기관실 빌지에서 흡입하도록 할 수 있는지, 그리고 그 방법이 무엇인지 아직 확인하지 못하였다. 그는 주기관 해수 냉각 펌프가 빌지에서 흡입할 수 있는지 알지 못하였다. 선장은 자신이나 선원들이 선박을 구하기 위해 할 수 있는 일이 거의 없다고 결론지었다. 그는 항해사와 나머지 갑판원들에게 선미 너머로 6인승 구명뗏목 두 개를 진수하라고 지시하였다. 둘 다 올바르게 팽창하였고 Chloe T호 좌현 풍하 쪽에 묶였다. 1634시에 해안경비대 관제관들은 선장이 구명뗏목이 팽창하였고 선원들이 Chloe T호 선미에 집합하였다고 보고한 것을 기록하였다. 기관실 문과 상갑판의 문 대부분은 닫혀 있었다. 항해사와 갑판원 한 명이 두 구명뗏목 중 첫 번째에 탔다. 기관사와 다른 갑판원이 두 번째 구명뗏목에 탔다. 마지막으로 선장이 첫 번째 구명뗏목에 탔다. 사고 전에 당직을 서고 있던 갑판원과 기관사/갑판원은 둘 다 조업 중에 일상적으로 착용하던 개인 부양장비를 입고 있었다. 나머지 선원은 고정 부력식 퇴선용 구명조끼를 입고 있었다. 선내에 방수복은 없었다. 선박의 EPIRB는 한 구명뗏목에, 휴대용 VHF 무선기는 다른 구명뗏목에 실려 있었다. 선원들은 계류줄을 끊고 구명뗏목들을 서로 묶은 뒤 Chloe T호에서 떠내려가게 하였다.
3.3.9 구조
Maersk Patras호, 브르타뉴 페리 Armourique호, M/V Mair호(트리니티 하우스(Trinity House) 용선), Dart Angler호, 어선 Amber J호와 Lady Maureen호를 비롯한 여러 선박이 "Mayday" 방송에 응답하였다. 수색구조 헬리콥터 R193이 현장에 도착하였고 1721시에는 Chloe T호 선원들을 구명뗏목에서 윈치로 끌어올리고 있다고 보고되었다. 솔컴(Salcombe) 영국 왕립구명정협회(RNLI) 전천후 구명정이 1726시에 Chloe T호 위치에 도착하였다. Langdon and Philip가 운영하는 또 다른 선박인 Lady Maureen호의 선장이 Chloe T호에 승선하여 구난 펌프를 설치하려고 시도하겠다고 자원하였다. 선박이 갑자기 전복될 경우에 대비하여 승선하지 말라는 조언을 받았고, 선박을 구난하려는 더 이상의 시도는 이루어지지 않았다. Chloe T호는 2226시에 침몰하였다(그림 11-14).
그림 12: Chloe T호(1855시에 촬영한 사진) 그림 11: Chloe T호(1757시에 촬영한 사진)원본 PDF 46쪽그림 13: Chloe T호(2013시에 촬영한 사진)원본 PDF 47쪽
3.4 선원과 주요 인원
3.4.1 선원
Chloe T호 선원 다섯 명은 모두 영국 국적이었으며 각자 Seafish의 필수 훈련 과정 네 가지를 이수하였다. Chloe T호의 선장은 39세였고 2000년부터 2급 어선 자격증명10을 보유하고 있었다. 선장은 Langdon and Philip에서 약 1년간 일하였으며 수리 중으로 운항하지 않던 다른 선박의 정규 선장이었다. 그는 선박의 정규 선장이 휴가를 가는 동안 약 1주일간 Chloe T호의 선장을 맡기로 되어 있었다. 정규 선장이 그에게 Chloe T호의 조업 방식을 보여 주었으나, 선장은 빌지 경보나 배수 배치의 세부 사항을 아직 살펴보지 못하였다. 선장은 0800-1400시와 2000-0200시에 조타실 당직을 섰다.
항해사는 30세였으며 평생 어업에 종사해 왔다. 그는 2급 어선 자격증명을 취득하기 위한 학업을 하는 중이었다. 항해사는 보통 Langdon and Philip의 다른 선박에서 갑판원으로 근무하였다. 그 선박 역시 수리 중이었고 그는 병가 중인 정규 항해사를 대신하고 있었다.
10 갑판 사관 해기 자격증명(어선) 2급(Deck Officer Certificate of Competency (Fishing Vessel) Class 2)
그림 14: Chloe T호(2020시에 촬영한 사진)원본 PDF 48쪽
항해사는 선박이 조업 어장으로 항해하는 동안 Chloe T호의 기관실을 딱 한 번 방문하였다. 그는 0200-0800시와 1400-2000시에 조타실 당직을 섰다.
기관사/갑판원은 47세였다. 그는 공식적인 기관 자격은 없었으나 지난 30년간 어선에서 바다 일을 해 왔고 그중 25년은 기관사로 일하였다. 또한 어업으로 돌아가기로 결정하기 전에 3년간 육상에서 자영업을 하며 보낸 적이 있었다. 그는 Langdon and Philip가 Chloe T호를 매입한 때부터 승선하고 있었다. 또한 매매가 완료되기 전 주말에 이전 선주의 선원들과 함께 선박의 기관과 계통에 대해 배우며 시간을 보냈다. 기관사/갑판원은 0400-1200시와 1600-0000시에 당직을 섰다. Chloe T호의 그물은 2시간마다 끌어올려졌으며, 기관사/갑판원은 매번 그물을 올린 뒤 기관실을 점검하는 일과를 갖고 있었다. 또한 매일 1900-2000시경 기관실에서 시간을 보내며 기관실을 더 상세히 점검하고, 일일 연료 탱크를 다시 채우고, 윤활유를 보충하고, 빌지의 물을 비웠다. 다른 갑판원 두 명은 모두 경험 많은 어부였으며 8시간 근무 후 4시간 휴식의 당직을 섰다. 두 사람 모두 선박의 주기관 운용에는 관여하지 않았다.
3.4.2 기타 주요 인원
Langdon and Philip는 다른 어선 여섯 척으로 구성된 선단을 운영하였다. 이 회사는 선박이 접안해 있을 때 선박을 지원하고 정비하기 위해 육상 기술 직원 세 명을 고용하고 있었다.
3.5 기관 배치
3.5.1 주기관
주기관은 역전 기어박스를 통해 고정피치 프로펠러를 구동하는 Stork 6FHD240이었다. 기관의 터보차저는 기관 후부 끝의 플라이휠 위에 위치하였다. 기관 선수 쪽 끝의 동력 인출 장치(power-take-off)는 각각 주 예인 윈치와 조타기에 동력을 공급하는 유압 펌프를 구동하였다. 기관은 압축 공기로 시동하도록 배치되어 있었다. 주기관 냉각은 개방 회로 해수 계통으로 열을 전달하는 열교환기를 거치는 폐쇄 회로 청수 계통으로 이루어졌다. 청수 계통과 해수 계통의 펌프는 모두 기관에서 기계적으로 구동되었다.
주기관 냉각 해수 흡입구는 기관실 좌현 후부 끝에 위치한 선체 관통 부속품이었다. MCA의 CM 파일에 보관된 선박의 세부 사항 기록(Record of Particulars)은 주기관 해수 냉각 배관의 직경이 85mm이고 해수 콕이 스크루다운식 역지형임을 나타냈다. 해수 콕 뒤에는 스트럼 박스(strum box) 스트레이너가 설치되어 있었다. 청소를 위해 스트레이너를 격리하는 추가 밸브는 없었다. Chloe T호의 해수 배관에 사용된 재료의 종류는 MCA의 기록에 기록되어 있지 않았다. 밸브에 사용된 재료는 NF로 확인되었는데, 이는 비철(non-ferrous)을 의미하는 것으로 추정되며 따라서 아마도 구리-니켈 합금이었을 것이다.
3.5.2 발전기
디젤 기관 구동 발전기 두 대가 주기관 양쪽에 각각 하나씩 설치되어 있었다. 발전기는 킬 냉각(keel-cooled)식이었다. 폐쇄 회로 계통의 청수가 기관 블록을 거쳐 선체 바깥쪽에 장착된 밀폐 열교환기로 펌프로 보내졌고 그곳에서 주위의 해수로 냉각되었다. 선박의 원래 직류(DC) 계통은 1997년에 415V 교류(AC) 계통으로 교체되었다.
3.5.3 빌지 배수
CM 파일에 포함된 선박의 세부 사항 기록에는 빌지 펌프의 종류나 용량에 관한 세부 정보가 없었다. 그러나 2002년 UKFVC 갱신을 위한 검사와 관련된 다른 서류에 첨부된, 당시 선주의 날짜 없는 정비 보고서는 3인치 전동 Stork 펌프가 두 대 있다고 기록하였다. 이 중 하나는 케이싱 마모로 인해 2002년의 계획된 수리 때 교체될 예정이었다. 배관은 직경 85mm의 연강으로 기록되어 있었으며, 이는 펌프의 3인치 흡입 및 배출 연결부와 (동일하지는 않지만) 일치한다. 이러한 종류의 펌프는 분당 약 1000리터, 즉 시간당 60톤의 물을 배출할 수 있는 것으로 추정되었다. 펌프 프라이밍을 위해 해수 흡입구가 제공되었다. 빌지 흡입 밸브 상자는 기관실 선수 쪽 우현에 위치하였다. 빌지 흡입은 선수창, 어창 앞쪽 창고, 기관실에서 할 수 있었다. 선외 배출은 선박 좌현의 역지 밸브를 거쳐 수선 위에 있었다. 비상 빌지 펌프로 수동 펌프도 설치되어 있었다. 이것은 사고 중에 사용되지 않았다.
Langdon and Philip가 운영하는 다른 선박에는 MCA의 권고에 따라 비상 구난 펌프로 사용할 휴대용 가솔린 펌프가 비치되어 있었다. Chloe T호는 매각될 때 이러한 펌프를 가지고 있지 않았고 새 선주들은 아직 이를 구입하지 않은 상태였다.
3.5.4 갑판 세척
직경 85mm 배관에 연결된 두 번째 전동 '3인치' Stork 펌프가 일반 용도 펌프로 제공되었다. 이것은 갑판 세척 계통으로 구성되어 있었다. 주 작업 갑판의 매니폴드가 물의 주 흐름을 Chloe T호 선수 끝의 게 탱크로 돌렸다. 물은 탱크에서 갑판으로 넘쳐 배수구를 통해 선외로 나갔다. 이 펌프는 어획물이 물고기가 쓸려 나가는 것을 막기 위해 갑판에 양륙되는 동안에만 꺼졌다. 일반 용도 펌프를 빌지 펌프로 작동하도록 재구성할 수 있었을 가능성이 높았으나, 사고 당시 Chloe T호에 승선한 선원 중 누구도 이것이 가능한지, 가능하다면 어떻게 하는지 확인하지 못하였다.
Chloe T호의 선원들은 어창과 기관실 모두에 빌지 경보 센서가 있음을 확인해 줄 수 있었다. 경보 패널은 조타실에 있었고 센서가 작동하면 음향 경보를 울렸다. 일련의 표시등이 어느 경보 센서가 작동하였는지를 나타냈다. 패널에는 또한 시험 기능이 있었는데, 이것이 모든 빌지 경보가 올바르게 작동하였음을 보여 주었다고 보고되었다. 어창 경보 센서는 처음에 장착부에서 떨어져 빌지로 떨어지는 바람에 여러 차례 조기 경보를 발생시켰다. 이는 기관사/갑판원이 수리하였고, 그 후 경보는 올바르게 작동하였다.
기관사/갑판원은 기관실에서 빌지 경보 센서 하나를 발견하였다. 이것은 주기관 좌현의 플라이휠 가까이에 있었다. 처음에는 작동하지 않았다고 보고되었으나 청소한 후에는 올바르게 작동하였다. 기관사/갑판원은 기관실에 다른 보조 또는 고수위 빌지 경보 센서가 설치되어 있는지 알지 못하였다.
3.6 정비 및 검사 이력
Langdon and Philip는 선박을 소유한 지 얼마 되지 않았으므로 법정 증서 외에는 Chloe T호의 검사나 정비 이력을 가지고 있지 않았다. 선박 매매와 함께 인계된 문서는 매우 적었다.
3.6.1 공식 기록
선박의 검사 및 정비 이력을 가늠하기 위해 MCA가 보관하고 있던 Chloe T호의 자문 해사(CM) 파일을 검토하였다. CM 파일은 법정 증서, 주로 영국 어선 증서(UKFVC)의 발급을 뒷받침하는 문서 증거를 제공하기 위해 보관된다. CM 파일은 선박의 완전한 정비 이력을 나타내도록 요구되거나 의도된 것이 아니었다. 각 선박마다 특정 주제별로 여러 개의 별도 파일이 작성될 수 있다. Chloe T호의 파일에는 건조(접미사 01) 및 복원성(접미사 04)과 관련된 CM 파일이 있었다. 선박의 기관(접미사 02)과 관련된 파일이 작성된 적이 있다는 기록은 없었다.
3.6.2 선박의 초기 이력
Chloe T호는 1989년에 영국 어선 등록부에 올라올 때 처음 검사를 받았다. 1994년에는 선박의 복원성 특성을 개선하고 1975년 어선(안전 규정) 규칙(The Fishing Vessels (Safety Provisions) Rules 1975)(이하 1975년 규칙)의 요건을 충족하도록 선미에 쉘터 갑판(shelter deck)이 추가되었다. 선박은 1997/98년에 주기관을 오버홀하고 해수 계통 배관의 상당 부분을 교체하는 대규모 수리를 받았다. 선박은 2000년에 소유자가 바뀌었고, 해수 계통에 대한 다음 작업 기록은 2002년에 나타나는데, 그때 모든 해수 밸브를 떼어내 오버홀하고 다시 설치하였다고 기록되었다. 해수 배관을 점검하였다는 구체적인 언급은 없었으나, 밸브를 떼어낼 때 적어도 배관의 일부는 보았을 가능성이 높다. 그 무렵 기관실 정비에 관하여 선주가 MCA에 한 보고는 빌지 펌프가 매년 정비되었다고 기재하였다.
3.6.3 UKFVC 갱신을 위한 검사 - 2002년
2002년 UKFVC 갱신을 위한 검사는 2002년 3월부터 7월까지 이루어졌다. MCA의 기록은 선체 검사(초음파 두께 계측 포함)와 경하 배수량 점검이 완료되었음을 보여 주었다. 세부 사항 기록(MSF 1301)을 검토한 결과 다음이 확인되었다.
›MSF 1301의 지침이 요구하는 일반 배치도, 평면도 및 측면도의 스케치가 작성되지 않았다.
›빌지 펌프에 관한 항목은 일부만 작성되어 있었다. 펌프가 위치한 구획이나 펌프의 용량에 대한 기록이 없었다. '동력원과 선내 위치' 칸에는 'Audible and visible in W’house from E.R.'이라고 적혀 있었다.
›MSF 1301의 지침이 요구하는 빌지 펌프 시험이 실시되었다는 기록이 없었다.
›1975년 규칙 제37(1)(b)(7)절의 면제가 부여되었다. 이 규칙이 적용되는 길이 12미터 이상 24.4미터 미만의 모든 선박은 다음을 갖추어야 한다.
o (1)(b) 빌지 펌프 두 대 이상.
›(i) 선박의 길이가 20미터 이상 24.4미터 미만인 경우 총 용량이 분당 455리터 이상일 것. 그러한 펌프 중 적어도 하나는 용량이 분당 230리터 이상인 동력 펌프여야 한다. 동력 펌프가 두 대 설치되는 경우 각 펌프는 독립적으로 구동되어야 한다.
o (3) 그러한 선박에서는 충분한 용량의 일반 용도 펌프를 독립 빌지 펌프로 사용할 수 있다.
o (7) 그러한 모든 선박에서는
›(a) 선박의 길이가 15미터 이상 24.4미터 미만인 경우 빌지 분기 흡입관은 안지름이 50밀리미터 이상이어야 한다.
UKFVC는 2002년 11월 8일에 발급되었으며 2006년 2월 24일까지 유효하였다. 이전 UKFVC는 8개월 넘게 전인 2002년 2월 24일에 만료되었다. 이 기간에 임시 증서나 연장이 부여되었다는 증거는 없었다.
3.6.4 UKFVC 갱신을 위한 검사 - 2006년
2006년 2월 24일에 만료 예정이던 UKFVC 갱신을 위한 검사는 2005년 11월에 시작되었다. 갱신 검사(2005년 11월 25일 실시)에는 다음과 같은 결함이 포함되어 있었다.
›기어박스 냉각관을 교체하고, 협의한 대로 주기관 흡입 스트레이너를 해수 펌프에 연결할 것
›기관실에 두 번째 독립 빌지 경보를 설치할 것
›기관실(E.R.)과 어창(F.R.)의 빌지 경보를 시험하여 입증할 것
›기관실 내 해수 코크(sea-cock)의 위치를 표시할 것 [sic]
Chloe T호의 모항 인근 MCA 해사사무소의 검사관은 2006년 2월 14일 선주에게 서신을 보내, UKFVC가 2월 24일 만료되며 선체 검사를 위해 선박을 상가(上架)해야 한다는 점을 상기시켰다. 선주는 2월 16일 답신을 보내, 지역 슬립(slip)을 사용할 수 있게 되는 불특정한 날짜까지 선체 검사를 미뤄 달라고 요청하였다. 2006년 2월 22일부터 2007년 2월 1일까지의 기간을 포괄하기 위해 단기 증서 6장이 발급되었다. 이 증서들은 현지에서 보관되었으며 선박의 CM 파일이나 SIAS에는 포함되지 않았다. 「어선 선체 상태 보고서(MSF 1328)」에는 2006년 7월 10일 초음파 선체 검사가 실시되었다고 기재되어 있었다. 2007년 2월 1일 정규 기간의 UKFVC가 발급되었으며 유효기간은 2011년 2월 24일까지였다. 증서와 첨부 문서에는 다음과 같이 기록되어 있었다.
›1975년 규칙 37(1)(b)(7)조에 대한 면제는 계속되었다. 면제 62는 삭제되었다. 선박에 화재 탐지 장치가 설치되었기 때문이었다.
›어창 빌지 웰은 청소하고 스크리드(screed)로 라이닝하였다(침식으로 얇아진 것이 확인되었기 때문이다).
›모든 시코크와 선외 배출 밸브를 떼어 내어 청소 및 점검한 뒤 선박에 되돌려 놓았다. 모든 외부 격자망을 떼어 내어 청소하였다.
›2007년 1월 30일자 CM 파일 문서 점검표(어선) MSF 1327에는 기관 정비 검사 보고서를 확인하였다는 내용이 포함되어 있었다.
명세 기록(양식 MSF 1301)은 양식에 명시된 요건에 따라 작성되지 않았다.
›선박 사진이 첨부되지 않았다.
›스케치(일반 배치도, 평면도 및 측면도)가 없었다.
›빌지 펌프 항목은 일부만 작성되었다. 펌프가 설치된 구획이나 펌프 용량에 대한 기록이 없었다. '동력원과 선내 위치' 열에는 '기관실(E.R.)에서 조타실(W'house)에 청각 및 시각 경보'라고 기재되어 있었다. 빌지 펌프는 2006년 9월에 시험한 것으로 기록되어 있었다.
2007년 2월 1일자 동봉 서신에는, 선주가 연례 자체 증명 점검을 완료하고 2008년 2월부터 2009년 2월 사이에 중간 검사가 실시되는 경우에만 UKFVC가 계속 유효하다고 기재되어 있었다.
3.6.5 2007년부터 2011년 사이의 검사
MCA의 SIAS 데이터베이스(부록 F)에는 Chloe T호에 대해 2007년 11월 8일과 2008년 5월 28일에 표적 검사가 실시되었다고 기록되어 있었다. 표적의 성격은 확인되지 않았으나 결함이 기록되었다. (두 검사 모두의) 각 결함은 SIAS에 '검사와 관련됨 - I'로 기재되어 있었다. 연례 자체 증명 점검이나 중간 검사가 실시되었음을 확인해 주는 구체적인 기록은 SIAS에도 CM 파일에도 없었다. CM 파일에 보관된 UKFVC 사본에는 검사가 실시되었다는 내용이 갱신되어 있지 않았다. 마찬가지로, 선주가 연례 자체 증명 신고를 완료하였다는 기록도 없었다.
2010년 중 Chloe T호에 대해 실시된 정비를 보고하는 문서 사본은 MCA의 비공식 현지 '작업' 파일에서 입수하였다. 이 문서에는 서명이 없었으나 선주를 대신하여 제공된 것으로 보였다. 정비 목록에는 '좌현 및 우현 빌지·일반 용도 펌프'를 분해 점검(overhaul)하였고 '여러' 배관을 필요에 따라 교체하였다는 기재가 포함되어 있었다.
3.6.6 UkFVC 갱신을 위한 검사 - 2011년
2011년 UKFVC 갱신을 위한 검사는 2011년 1월 19일에 시작되었다. MCA의 현지 검사관은 여러 결함을 확인하였으며, 그중 이 사고와 가장 관련이 깊은 것은 '모든 기관 경보를 시험하여 입증할 것'이었다. 그 밖의 검사 결함으로 보아, 검사관은 비상 훈련, 선원 자격증명 및 위험성 평가를 확인하는 데 특히 주의를 기울였던 것으로 나타났다. 검사관은 각 결함이 시정되었을 때 이를 표시하고 날짜를 기입하였다. 아울러 검사관은 모든 결함이 2011년 4월 26일까지 시정되었다고 검사 보고서에 서명하였다.
선체 상태 검사는 선박을 상가한 상태로 2011년 2월 21일에 실시되었다. 선체는 5년 전의 이전 검사 이후 크게 악화되지 않은 것으로 확인되었다. 해수 흡입구(sea chest), 빌지 흡입 웰 및 오수관은 모두 양호한 상태로 확인되었다. 경하 상태 검사는 2011년 2월 24일에 실시되었고, 그 결과는 이전의 점검 결과와 잘 부합하는 것으로 확인되어 Chloe T호의 복원성 자료를 더 검토할 필요는 없었다. UKFVC는 2011년 2월 24일 만료되었다. 2011년 2월 28일부터 2011년 8월 1일까지의 기간을 포괄하기 위해 단기 증서 3장이 발급되었다.
'어선(안전 규정) 규칙 1975 - 다음 규칙의 적용으로부터 면제 필요: 강철 선체 선박: 길이 24.4m 미만 Reg.'라는 제목의 비공식 양식에는 1975년 규칙의 여러 부분에 대한 다수의 참조가 열거되어 있었다. 이 참조 대부분(빌지 배수와 관련된 37(1)(b)(7)조 포함)에는 강조 표시가 되어 있었다. 이 양식은 '선주 서명'이라고 표시된 곳에 서명되어 있었고 날짜는 2011년 3월 18일이었다.
2011년 2월 25일자 전기 검사 보고서에는 Chloe T호의 전기 계통이 모두 양호한 상태라고 기재되어 있었다. 지락(earth fault)은 발견되지 않았고, 케이블은 이중 절연이며 품질이 양호한 것으로 확인되었다. 또한 선박의 배전반에는 조작자가 지락을 쉽게 점검할 수 있도록 계기가 내장되어 있다고 보고되었다.
MCA 양식 'CM 파일 문서 점검표(어선) MSF 1327'에는 '정비 보고서 - 기관'을 확인하였다고 표시되어 있었다. 그러나 이 점검표 양식에는 서명도 날짜도 없었다. 명세 기록(MSF 1301)은 2011년 7월 18일의 최종 검사일을 기준으로 갱신되었다(부록 G). 이 기록은 양식에 명시된 요건에 따라 작성되지 않았다.
›선박 사진이 첨부되지 않았다.
›스케치(일반 배치도, 평면도 및 측면도)가 없었다.
›빌지 펌프 항목은 일부만 작성되었다. 펌프가 설치된 구획이나 펌프 용량에 대한 기록이 없었다. '동력원과 선내 위치' 열에는 '기관실(E.R.)에서 조타실(W'house)에 청각 및 시각 경보'라고 기재되어 있었다. 빌지 펌프는 2011년 3월에 시험한 것으로 기록되어 있었다.
명세 기록에는 기관실에 '보조' 빌지 경보가 설치되어 있으며, 이 장치는 2011년 3월 MCA 검사관의 시험을 거쳐 만족스러운 것으로 확인되었다고 기재되어 있었다. 2011년 7월 21일 정규 기간의 UKFVC가 발급되었으며 유효기간은 2016년 2월 26일까지였다. 빌지 배수에 관한 1975년 규칙(37(1)(b)(7)조)의 면제가 허용되었다. UKFVC에 첨부된 동봉 서신에는 연례 자체 증명을 실시해야 하며 2013년 2월부터 2014년 2월 사이에 중간 검사를 반드시 실시해야 한다고 선주에게 상기시키는 내용이 있었다.
3.6.7 기타 검사 및 점검
선박 소유자를 대신하여 2011년 9월 30일 Chloe T호에 대한 가치 평가 검사가 실시되었다. 기계 목록에는 빌지 펌프와 일반 용도 펌프가 확인되어 있었으나, 해수 흡입 밸브나 해수 배관의 상태 또는 연한과 관련된 논평은 없었다. 이 검사는 기관실이 '최근의 효과적인 정비 흔적이 있는 매우 양호한 상태로 보였다. 주기관, 보조기관 및 부속 기계는 완전히 작동 가능하고 정비가 잘 된 상태로 보였다.'라고 결론지었다.
MCA 검사관들은 Chloe T호에서 두 차례 추가로 표적 검사를 실시하였다. 첫 번째는 2012년 2월 2일에 실시되었으며 새 트롤 윈치의 설치와 관련된 것이었다. 두 번째는 선박에 선박자동식별장치(AIS)를 설치하도록 요구하는 것이었다.
4절 분석
4.1 목적
분석의 목적은 사고의 기여 원인과 경위를 규명하여, 앞으로 유사한 사고가 발생하지 않도록 권고를 하기 위한 근거로 삼는 것이다.
4.2 기관실 침수
선원들이 기관실로 물이 들어오고 있음을 알았을 때에는 이미 수위가 너무 높아 어디에서 물이 들어오는지 볼 수 없었다. 수위는 계속 상승하였고 침수의 원인을 확인하는 것은 끝내 불가능하였다.
Chloe T호가 금전적 이유로 고의로 침수되었을 가능성이 검토되었으나, 다음과 같은 이유로 배제되었다.
›선박은 성공적이고 수익성 있게 조업하고 있었던 것으로 보고되었다.
›다음 갱신 검사 시기까지 상당한 기간이 남아 있었다.
›추가 공구, 예비품 및 어구가 구입되어 선박에 실려 있었다.
›선박은 조업 항해 도중이었으며 이미 값진 어획물이 선상에 있었다.
4.2.1 침수 가능 원인
Chloe T호의 기관실로 물이 들어올 수 있었던 주된 경로는 두 가지였다. 하나는 선체 외판의 파손이고, 다른 하나는 해수 계통 중 하나의 고장이다.
기관사 겸 갑판원이 처음 기관실에 들어갔을 때 수위가 프로펠러 축 아래에 있었고 이 부근에서 물이 스며든 흔적이 보이지 않았으므로, 프로펠러 축 실(seal)을 통한 침수는 배제할 수 있다. 빌지 배수 계통을 통한 역류(back-flooding) 또한 배제할 수 있다. 밸브가 어창에서 배수하도록 열려 있는 상태였기 때문이다. 기관사 겸 갑판원은 경보를 듣고 기관실에 들어가자마자 밸브를 재구성하였다. 따라서 역류가 있었다면 기관실이 아니라 어창이 침수되었을 것이다. 마찬가지로 일반 용도 펌프 배출(갑판 세척) 계통의 고장도 배제할 수 있다. 이 계통은 Chloe T호 선수 부근 갑판 위의 게 탱크로 물을 퍼 올리도록 구성되어 있었다. 디젤 발전기가 트립된 뒤 일반 용도 펌프를 다시 시동하지 않았는데도 기관실은 계속 침수되었다.
4.2.2 선체 외판 파손
Chloe T호가 물속의 어떤 물체와 충돌하였다거나, 어구를 취급하는 동안 선체 외판이 손상되었다고 볼 만한 증거는 없었다.
가장 최근의 두 차례 선체 검사(2007년과 2011년)에서는 선체 외판의 두께가 허용 가능한 수준이라고 기록되었다. 더 중요한 것은 두 검사 결과의 차이가 거의 없었다는 점으로, 이는 진행 중인 부식이 많지 않았음을 나타낸다. 마지막 선체 검사 이후 사고까지 19개월 동안 이러한 안정된 상태가 계속되었다는 보장은 없지만, 부식 속도가 그토록 급격히 증가하려면 중대한 변화가 있어야 하며 아마도 그것은 눈에 띄었을 것이다.
선체 외판 부식 속도가 크게 증가하는 한 가지 원인은 Chloe T호 전기 계통의 결함으로 인한 전해 작용일 수 있다. 전형적으로 전기 절연 파괴나 기타 누전 결함의 결과로 선체 외판의 일부 부위가 양극이 되어 빠르게 부식될 수 있다. 그러나 가장 최근의 전기 검사 보고서는 Chloe T호의 전기 계통이 높은 수준으로 설치되었고 양호한 상태로 유지되어 있다고 결론지었다. 따라서 이 잠재 원인은 가능성이 낮은 것으로 본다.
선체 외판 파손의 또 다른 원인은 국부 침식으로, 이는 보통 빌지 흡입 지점 부근에서 수년에 걸쳐 발생한다. 이 문제는 2007년 선체 검사에서 Chloe T호의 어창 빌지 웰에서 발견된 바 있다. 빌지 웰은 수리되었고 더 이상의 열화는 기록되지 않았다. 기관실 빌지 흡입구 부근 선체 외판의 상태는 가장 최근의 두 선체 검사 어디에도 구체적으로 기록되어 있지 않았다. 그러나 선체 외판의 초음파 두께 측정값에서는 우려할 만한 점이 나타나지 않았다.
4.2.3 해수 계통 고장
가장 최근의 검사 보고서에는 모두 선체 흡입 및 배출 밸브를 떼어 내어 분해 점검하고 다시 장착하였다고 기록되어 있었다. 따라서 이 밸브들이 사고 당시 허용 가능한 상태였을 것이라고 기대하는 것이 합리적이다. 해수 박스(sea box)의 외판도 상당히 양호한 상태였다.
해수 계통은 주기관 냉각, 냉동 및 유압 냉각용 흡입·배출 배관과 일반 용도 배수 계통으로 구성되어 있었다. 선외 배출관에는 모두 역지 밸브가 설치된 것으로 기록되어 있었다. 작업 메모나 결함 기록에는 일부 구간의 배관을 때때로 교체하였다는 언급이 있었다. 그러나 해수 계통의 배치에 대한 기록은 없었고, 더 중요하게는 정확히 어느 구간의 배관이 교체되었는지에 대한 기록도 없었다. Chloe T호와 같은 형태와 선령의 선박에서는 모든 구간의 배관에 접근하기가 악명 높을 만큼 어렵다. 이러한 계통은 현대적 기준으로 볼 때 광범위하고 복잡하며, 상당수가 빌지 깊숙이 낮은 곳에 있어 흔히 주요 기기에 가로막혀 있다. 따라서 CM 파일의 기록이 흔히 배관을 '필요에 따라' 교체한다고 언급한 것은 놀라운 일이 아니다. 이러한 모든 요인은 해수 계통 배관을 점검하거나 교체하는 체계적인 계획이 없었음을 강하게 시사한다.
어떤 형태의 발견되지 않은 부식으로 인한 배관 파손은 기관실 침수의 흔한 원인이며, Chloe T호의 구조와 이력으로 볼 때 이 선박은 이 문제에 특히 취약했을 것으로 보인다. 따라서 침수의 가장 가능성 높은 원인은 해수 계통 배관 일부의 파손인 것으로 본다.
4.2.4 침수 속도
기관사 겸 갑판원이 기관실에 들어갔을 때에는 이미 충분한 양의 물이 들어와 있어 물이 어디에서 들어왔는지 볼 수 없었다. 그는 이어서 빌지 펌프를 가동하였는데, 이 펌프의 용량은 60톤/시간으로 추정되었다. 수위는 바닥판 위로 계속 상승하였으며, 나중에 '10분에 6인치' 상승한 것으로 추정되었다. 이 단계에서 기관실 측면(선체 외판과 격벽으로 이루어진)은 대체로 수직이었을 것이다. 위에서 내려다보면 수면은 대략 정사각형으로 보였을 것이며 각 변의 길이는 약 6.5m였을 것이다. 계산을 단순화하기 위해 주기관과 기타 기계가 차지하는 부피를 무시하면11 침수 속도는 39톤/시간으로 추정할 수 있다. 펌프가 최대 용량으로 작동하고 있었다고 가정하면 총 침수 속도는 39톤/시간에 60톤/시간을 더한 값이었을 것이다. 이 추정의 명백한 한계를 감안하여 총 침수 속도는 약 100톤/시간으로 근사할 수 있다.
Chloe T호의 흘수는 2.8m였던 것으로 보고되었다. 해수 계통은 선체 외판 가까이에 있었을 것이므로 수선 아래 약 2.7m에 있었다고 가정하였다. 오리피스를 통한 정상류에 대한 베르누이 이론을 사용하면, 수선 아래 2.7m에 있는 지름 약 88mm(3½인치)의 구멍이 약 100톤/시간의 침수 속도를 일으킬 것임을 알 수 있다(부록 H). 주기관 해수 냉각 펌프의 배출 측 배관이 파손되어도 비슷한 침수 속도가 발생할 수 있었을 것이다. 이 경우 해수 냉각 펌프가 물을 밀어내므로 더 작은 구멍에서도 같은 침수 속도가 나올 수 있다.
4.2.5 가장 가능성 높은 원인
앞 절의 추정은 침수 속도가 상당한 크기의 구멍으로만 발생할 수 있었음을 시사하며, 이는 중대한 파손으로 인한 것이었을 것이다. 앞서 논의한 바와 같이, 이러한 중대한 파손의 가장 가능성 높은 원인은 부식으로 인한 해수 계통 일부의 파손이었다. 필요했을 구멍의 크기를 감안하면, 파손은 주기관 냉각수 계통의 일부에서 발생했을 가능성이 높다. 침수는 주기관이 정지된 뒤에도 거의 같은 속도로 계속되었다. 따라서 구멍은 해수 냉각 펌프의 흡입 측 배관에 있었고, 침수는 펌프 배출의 추가 효과 없이 정적인 해수 압력만으로 일어났을 가능성이 더 높다.
4.3 침수 경보
4.3.1 일반 원칙
침수는 물이 새어 들어오는 속도보다 빠르게 물을 퍼내야만 통제할 수 있다. 이는 펌프를 추가하거나, 침수 원인을 찾아 침수 속도를 억제함으로써 할 수 있다. 당연하게 들리지만 실제로는 선내의 모든 펌프를 사용하더라도 어느 선박이나 배수할 수 있는 최대 속도가 있다. 그러면 침수는 원인을 찾아낼 수 있을 때에만 막을 수 있다. 이는 침수 깊이가 수십 센티미터를 넘으면 극히 어렵다. 따라서 침수가 시작되는 즉시 선원들에게 경보가 전달되는 것이 필수적이며, 신뢰할 수 있고 올바른 위치에 설치된 빌지 경보가 필수적이다.
4.3.2 Chloe T호의 빌지 경보
Chloe T호에는 주기관 플라이휠 가까이에 빌지 경보 센서가 하나 설치되어 있었다. 빌지 경보 센서는 더러웠고 기관사 겸 갑판원이 발견했을 때 작동하지 않았다. 그가 센서를 청소하자 다시 작동하였다. 그러나 센서가 계속 깨끗하게 유지되거나 계속 작동한다는 보장은 없었다. 센서는 기관 오일이 다시 묻어 작동하지 못하게 되기 쉬웠을 것이며, 크랭크축 오일 실에서 새는 오일은 곧 플라이휠로 흘러갔을 것이다. 2011년 7월의 MSF 1301 양식에는 Chloe T호에 보조 빌지 경보 센서가 설치되어 있다고 기록되어 있다. 그러나 선원들은 이 센서가 어디에 있는지, 또는 올바르게 작동하는지 알지 못하였다. 주기관 플라이휠 가까이의 빌지 경보는 마지막 항해 시작 시에 시험되지 않았고 사고 중에도 작동하지 않았으므로, 이것이 신뢰할 수 있게 작동했다고 믿기는 어렵다.
4.3.3 보조 빌지 경보
빌지 경보 센서는 가혹한 환경에서 작동할 수 있어야 한다. 그러나 센서가 견딜 수 있는 데에는 한계가 있으며, 센서는 주기적으로 점검하고 교체해야 한다. 이 주기는 빌지가 일상적으로 젖어 있거나 기름기가 있는 선박에서는 짧아지는데, Chloe T호는 사용 기간 동안 이 두 가지 문제를 모두 겪었을 것이다. 빌지 경보 센서를 마지막으로 교체한 시기에 대한 기록은 없었고, 센서는 언제든 고장 났을 수 있었다.
4.4 비상 대응
4.4.1 침수에 대한 대응
선장, 항해사 및 기관사 겸 갑판원은 연기 경보에 신속히 대응하였다. 그들은 경보에 대한 뚜렷한 설명이 없음을 알고 확인하러 갔다. 다른 선원들에게도 경보가 전달되어 집합하였다. 침수는 명백하였고 기관사 겸 갑판원은 즉시 빌지 펌프를 가동하고 기관실에서 물을 퍼 올리도록 밸브를 구성하였다. 그와 이후에는 선장이 기관실을 수색하여 침수 원인을 찾으려 하였다. 침수 원인이 가려져 있어 물이 들어오는 속도를 줄이기 위해 즉시 취할 수 있는 조치는 없었다.
기관사 겸 갑판원은 해수 계통 배관이 원인일 수 있다고 현명하게 결론짓고 주기관 해수 흡입 밸브를 잠그려 하였다. 이 밸브는 불어나는 침수 수위 때문에 접근하기가 쉽지 않았다. 밸브를 찾아 조작하는 것은 기관사 겸 갑판원을 극도로 위험한 상황에 빠뜨렸을 것이며, 그는 그 위험을 무릅쓰지 않기로 현명하게 결정하였다. 그러나 기관사 겸 갑판원이 직면한 상황은 충분히 예견할 수 있었고 피할 수 있었다. MCA와 다른 기관들은 오랜 기간 지침을 발간해 왔는데, 이 지침은 밸브가 침수된 물에 잠겨 달리 접근할 수 없게 된 뒤에도 이를 닫을 수 있는 어떤 수단이 있어야 한다고 권고한다.
주기관 해수 흡입 밸브에 접근할 수 없었더라도 다른 선택지가 있었다. 일반 용도 펌프를 기관실에서 퍼 올리도록 재구성할 수 있었을 것이나, 당시 선상에 있던 선원 중 누구도 알지 못하였다
11 기계가 차지하는 기관실 부피는 기관실 전체 부피에 비해 상대적으로 작은 비율일 것이다.
이를 어떻게 하는지를. 이 펌프는 빌지 펌프와 동일하였으며, 두 펌프 모두 60톤/시간을 퍼 올릴 수 있었다고 가정하면 두 펌프를 함께 사용하여 침수를 억제할 수 있었을 가능성이 있다12. 다른 해수 계통의 흡입 밸브는 접근하기가 더 쉬웠고 잠글 수 있었을 것이다. 이것이 침수 속도에 영향을 주지 못했더라도, 나중에 선박을 인양할 가능성을 높이는 데 도움이 되었을 수 있다.
그물을 끌어 올린 것은 어선에서 일어나는 어떤 비상 상황에도 이해할 만한 반응이지만, Chloe T호의 복원성 여유를 불필요하게 더욱 줄였다. 선원들은 이를 재빨리 알아차렸고 윈치에서 예망줄을 풀어 내보냄으로써 문제를 해결하였다.
4.4.2 퇴선
선장은 매우 신속하게 해안경비대에 침수 사실을 알렸고, 침수를 통제할 수 없음을 깨닫자마자 'Mayday' 메시지를 방송하였다. 여러 선박이 'Mayday'에 응답하여 지원을 제공하기 위해 대기하였다. 선장은 침수를 통제하기 위해 더 할 수 있는 일이 거의 없고 Chloe T호의 복원성 여유가 줄어들고 있음을 확인하자마자 선원들에게 선박을 포기하고 퇴선하도록 결정하였다. 선원들은 이미 구명뗏목을 준비하라는 지시를 받았고, 구명뗏목은 팽창되어 선박의 바람 아래쪽에 고정되어 있었다. 모든 선원은 구명조끼를 착용하고 있었는데, 갑판에서 작업할 때 일상적으로 착용하던 개인 부양장비(PFD)이거나 퇴선용 구명조끼였다. 각 선원은 물에 들어가지 않고 구명뗏목에 탈 수 있었다. 휴대용 VHF 무선기는 한 구명뗏목에, EPIRB는 다른 구명뗏목에 실었다. 이는 이후 구명뗏목들이 서로 떨어지더라도 각각 장거리에서 주의를 끌 수단이 있었음을 의미하였다.
선원 진술과 MCA 검사관의 기록 모두에서, Chloe T호에서 비상 훈련이 실시되었다는 증거가 있었다. 이는 매우 칭찬할 만한 일이었으며 비상 상황에서 선원들의 대응에 틀림없이 도움이 되었다. 선장이 Chloe T호를 포기하고 퇴선하기로 일찍 결정하고 선원들이 숙고하여 대응한 덕분에, 선원들과 잠재적 구조자들에 대한 위험이 최소화되었다.
4.5 선주와 선원의 역할
4.5.1책임
15-24m 규약(15-24m Code)은 선박을 검사와 중간 검사에 제시하는 것이 선주의 책임임을 분명히 하고 있다. 선주(또는 선주가 위임한 대리인)는 또한 선박이 여전히 규약의 요건을 충족하고 있음을 확인하는 연례 자체 신고를 완료할 책임이 있다. 이러한 의무 외에도 선주와 선장에게는 선박이 감항성을 갖추고 안전하게 운항될 수 있도록 보장할 더 실무적인 책임이 있다.
12 침수 속도는 약 100톤/시간으로 추정되었다. 빌지 펌프와 일반 용도 펌프가 각각 용량 60톤/시간인 3인치 스토크(Stork) 펌프였다면, 잠재적 최대 배수 속도는 120톤/시간이었다.
4.5.2 구입과 숙지
Langdon and Philip의 선주와 그 직원들은 어선을 운항하고 정비한 경험이 매우 많았다. 그들은 보험이나 기타 재정적 이유로 인해 정식 구입 전 검사를 받아야 할 의무가 없었다. 그들은 Chloe T호가 비교적 최근에 법정 갱신 검사를 마쳤다는 점에 안심하였고, 스스로 Chloe T호의 상태를 평가할 만큼 충분히 자신감을 느꼈다. 해수 배관 중 부식되어 갑자기 파손될 수 있는 것이 없음을 확신하려면 매우 상세한 검사를 실시해야 했을 것이다.
기관사 겸 갑판원은 이전 운영자들로부터 Chloe T호에 대해 배우는 데 자신의 시간을 상당히 많이 들였다. 이는 칭찬할 만하였으나 불행히도 핵심적인 특징들이 누락되었다. 여기에는 다음이 포함된다. 보조 빌지 경보의 존재 여부, 주기관 플라이휠 가까이에 설치된 빌지 경보 센서의 신뢰성 확인, 그리고 비상시 기관실 빌지를 퍼 내는 데 사용할 수 있는 다른 방법의 확인이다. 이러한 쟁점들은 각각 사고에서 결정적이었으나 Chloe T호의 정상 운항에는 필요하지 않았다. 이는 우선순위가 더 낮다고 여겨졌을 가능성이 높다. 선박의 기본 운용을 숙달한 뒤에 알아 두면 유용한 사항으로 여겨졌을 것이다.
4.5.3 운용
기관실의 빌지 경보 센서가 작동하는 것으로 마지막으로 확인된 것은 사고 일주일도 더 전이었다. 센서가 다시 오염되어 사고 중에 작동하지 않았을 가능성이 상당히 높았다. 빌지 경보 센서는 정기적으로 점검해야 한다. 확실히 매 조업 항해를 시작하기 전에, 그리고 이상적으로는 해상에서 매일 점검해야 한다. 기관사 겸 갑판원은 가동 중인 기계를 점검하는 좋은 작업 루틴을 갖고 있었다. 그러나 이는 Chloe T호의 정상 운항에 초점이 맞춰져 있었다. 경보를 점검하거나 비상 상황에 대처하기 위해 계통을 재구성하는 방법을 더 알아 두는 데에는 훨씬 적은 관심이 기울여졌다.
4.6 법정 검사 제도의 실효성
MCA는 어선에 대한 법정 검사와 점검의 범위와 수행에 관한 상세한 요건을 발간한다. 이러한 요건은 Chloe T호에서 여러 분야에서 충족되지 않았다.
4.6.1 검사와 점검의 일정
이 사고와 가장 관련이 깊었으므로 2002년, 2006년 및 2011년 Chloe T호의 UKFVC 갱신을 위한 검사 기록을 살펴보았다. 각 경우에 절차에 지연이 있었는데, 2002년에는 8개월, 2006년 2월부터 2007년 2월까지, 그리고 2011년 2월부터 8월까지였으며, 그 결과 선박은 단기 증서를 발급받았다. 이는 예외적인 상황에서 최대 2개월까지 연장을 허용할 수 있다고 명시한 15-24m 규약의 요건에 반하는 것이었다. 2002년과 2006년의 갱신 검사 사이, 그리고 2006년과 2011년 사이에 어떤 중간 점검이 실시되었음을 보여 주는 기록은 없었다. SIAS 기록에는 중간 점검이 예상되는 시기 즈음인 2007년과 2008년에 점검이 실시되었다고 나타나 있었다. 그러나 이 둘 모두 '표적' 점검으로 기록되어 있었고, 이것이 중간 점검의 요건을 충족했는지는 기록으로 판단할 수 없다. 따라서 선박이 요구되는 대로 중간 점검을 받지 않았을 가능성이 있으며, MSIS 27의 기재에 따르면 UKFVC는 2009년 2월부터 2011년 4월까지 무효였다. 그러나 Chloe T호는 사고 당시에는 유효한 UKFVC를 갖고 있었다. MCA의 기록이 시사하듯 중간 검사가 실시되지 않았다면, Chloe T호는 2005년 2월부터 2006년 2월까지 약 12개월 동안, 그리고 2009년 2월부터 2011년 2월까지 2년 동안 유효한 UKFVC 없이 운항한 것이 된다. 규정에 반할 뿐 아니라, Chloe T호가 MCA 문서에서 요구된다고 명시한 수준의 검사와 점검을 장기간에 걸쳐 받았을 가능성은 낮다. 15-24m 규약이 선박을 검사에 제시하는 것은 선주의 책임임을 분명히 하고 있지만, MCA가 MSIS 27에 명시된 대로 선박을 억류하는 조치를 취하였다는 증거는 없었다. 따라서 MCA의 검사관들이 Chloe T호의 검사와 점검이 기한을 넘긴 사실을 알지 못했거나, 그러한 상황을 묵인할 용의가 있었다고 결론지을 수밖에 없다.
4.6.2 검사의 범위와 기준 준수
MCA는 어선의 검사와 점검에 대해 광범위한 범위를 정해 놓았다. 그 기준은 더 큰 상선에서 실시하는 것과 대체로 동등하다. 그러나 전체 범위가 적용되었음을 보여 주는 증거는 불충분하였다. 이 사고와 가장 관련이 깊은 것은 해수 계통에 대한 요건이었다. 여기에는 다섯 가지 서로 다른 MCA 문서에 다음에 대한 요건과 지침이 포함되어 있었다.
›해수 계통 배관의 체계적인 점검.
›해수 흡입 및 배출 밸브를 기관실 바닥판 위의 위치에서 조작할 수 있도록 보장.
해수 밸브의 조작과 해수 계통 배관의 점검에 관한 요건을 충족하는 것은 잠재적으로 어려울 수 있었다.
해수 밸브
Chloe T호의 해수 흡입 및 배출 밸브는 모두가 기관실 바닥판 위에서 쉽게 조작할 수 있는 것은 아니었다. 기관사 겸 갑판원은 주기관 냉각 해수 흡입 밸브가 불어나는 침수 속에 잠겨 있어 닫을 수 없었고, 접근성을 높이기 위해 바닥판을 떼어 내기 시작하였다. 이때 침수 수위는 바닥판 높이쯤이었으므로, 이 밸브는 15-24m 규약, MSIS 23, MSIS 27, MSF 5550 또는 MGN 165에 명시된 대로 접근 가능하지 않았다고 결론지을 수 있다. 정확한 이유는 판단할 수 없었다. 이 문제가 면제로 처리되었다는 증거는 없었고, Chloe T호는 1989년과 사고 사이에 여러 MCA 직원에게서 검사와 점검을 받았다. 따라서 이 요건이 단순히 간과되었을 가능성은 낮다.
주기관 냉각 해수 밸브를 더 접근하기 쉬운 위치로 옮기는 것은 상당한 작업이었을 것이다. 최소한 새로운 길이의 배관이 필요했을 것이며, 아마도 공기 빼기와 마중물 주입을 포함하여 물의 흐름이 방해받지 않도록 하는 배치가 필요했을 것이다. 이 모든 것을 기존 기계들 사이에 설치하는 것은 기술적으로 어렵고 비용도 많이 들었을 가능성이 매우 높다. MCA가 권고한 대안은 해수 흡입 밸브에 원격 조작 장치를 설치하는 것이었을 수 있다. 가장 단순한 형태로는 보조 밸브 핸들에 연결된 연장 스핀들(아마도 1미터 길이)일 수 있다. 그러나 연장 스핀들도 설치하기 어려울 수 있다. 기관사 겸 갑판원은 해수 흡입 밸브에 닿으려면 기관실 구석으로 기어 들어가야 했을 것이며, 기관실의 이 부분은 위쪽 거주구역 때문에 높이가 제한되어 있었다고 설명하였다. 이런 곳에서는 연장 스핀들이 이상적이지 않을 수 있음을 쉽게 상상할 수 있다.
Chloe T호의 운영자 중 누구도 해수 흡입 밸브를 더 접근하기 쉽게 만들기로 선택하지 않았고, 검사관들로부터 그렇게 하도록 요구받은 적도 없었음이 분명하였다. 반대되는 증거가 없는 상황에서, 이에 대한 가장 명백한 이유는 그 요건이 달성하기에 너무 어렵다고 여겨졌고 개조의 필요성이 충분히 강하게 제기되지 않았기 때문이라고 결론지을 수밖에 없다.
해수 배관
Chloe T호와 같은 구조 방식의 선박 빌지에서 배관 구간을 떼어 내는 것은 쉬운 일이 아니며, 불가피한 이유가 있거나 알려진 문제를 처리하기 위해서만 이루어질 것이다. 배관을 제자리에서 검사하는 것도 마찬가지로 어렵고 배관의 상태에 대해 매우 제한된 정보만 제공할 것이다. '망치 타격 시험의 폭넓은 활용' 권고는 의문스럽다. 오래된 선박에서는 이를 선박이 물에 떠 있는 동안 실시할 경우 검사관이 배관을 뚫어 통제할 수 없는 침수로 이어질 현실적인 가능성이 있다. 해수 계통을 압력 시험하라는 조언은 이론상으로는 타당하지만 실제로 이행하기는 극히 어렵다. 시험을 실시할 적절한 장비와 부속품을 공급해야 한다는 점 외에도, 권고된 3 bar의 압력을 안전하게 가하는 데 중대한 문제가 있다. 장비, 특히 노후한 열교환기가 손상될 위험이나 부속품이 압력에 이탈할 위험이 있다(3 bar의 압력은 수심 30m에서 해수가 가하는 압력, 즉 Chloe T호 흘수의 10배에 해당하는 압력과 대략 같다). 그러나 가장 가능성 높은 결과는 압력이 유지되지 않는 것이며, 그러면 검사관은 누설이 계통에서 나는 것인지, 시험 장비에서 나는 것인지, 둘 다인지 판단해야 하는 과제에 직면한다. 검사관이 어느 한 선박에서 한 계통만 보는 데 모든 시간을 쓸 수는 없다. 어선 선주가 (더 큰 선박에 대해 선급이 보관하는 것과 같은) 체계적인 배관 점검 계획을 갖고 있을 가능성은 낮아 보인다. 확실히 Chloe T호에 그러한 계획이 있었다는 증거는 없었다. 결과적으로 검사관은 숙고된 결정을 내릴 충분한 시간이나 정보 없이 판단을 내려야 하는, 달갑지 않은 처지에 놓인다.
4.6.3 기록 보관
MCA의 기록 보관 체계는 사실상 세 가지 체계, 즉 공식 CM 파일, SIAS 데이터베이스, 그리고 현지의 종이 및 컴퓨터 기록에 걸쳐 분산되어 있다. 어느 체계도 단독으로는 모든 요건을 충족하지 못하며, 각 체계 사이의 연계 품질은 전적으로 개별 직원에게 달려 있다. 이 체계는 오류, 누락 및 실수에 극히 취약하다. 이는 이번 조사 과정에서 검토한 모든 서류에서 분명하였다. 검사 양식이 완전히 작성되지 않은 사례가 여러 건 있었는데, 사진이나 도면이 없었고, 장비에 대한 설명이 불완전하였으며, 시험 결과가 기록되지 않았다. 그러나 가장 우려되는 것은 선박 기관에 대한 CM 파일이 한 번도 작성된 적이 없다는 점이었다. 기관 검사 결과를 기록할 파일이 없는 것은 MSIS 27 등에 기술된 기관 검사의 범위와 양립할 수 없다. 그 결과 Chloe T호에 설치된 기계, 그 운용과 상태에 대한 MCA의 기록은 불완전하다. 이는 현지 작업 파일과 선주의 비공식 메모로 부분적으로 보완되었으나, MCA와 선주는 선박의 상태를 감시할 중요한 기회를 스스로 포기한 셈이었다. 따라서 중대한 고장이 발생할 가능성이 훨씬 더 컸다.
SIAS에 기록된 2007년과 2008년 Chloe T호에 대한 표적 점검을 UKFVC를 유효하게 하는 데 요구되는 중간 점검으로 간주할 수 있었을 가능성은 있다. 그러나 이것이 구체적으로 기록되어 있지 않은 이상, 그 점검의 지위, 그리고 따라서 UKFVC의 유효성에 대해서는 항상 약간의 의문이 남을 것이다.
4.6.4 면제
Chloe T호는 빌지 배수 계통의 성능에 관한 1975년 규칙에 대해 면제를 허용받았다. 이 면제는 선주와 검사관이 미리 준비된 '표준' 면제 목록에서 원하는 면제를 강조 표시하는 것만으로 갱신 검사 때마다 연장되었다. 이는 (화재 탐지 장치의 설치를 제외하면) 검사 때마다 거의 같았다. 이번 조사의 일환으로 빌지 배수에 주어진 면제의 타당성을 검토했을 때, CM 파일에는 면제가 유효한지 여부를 판단하기에 충분한 정보가 없었다. CM 파일의 정보를 (구입 검사를 포함한) 다른 출처와 결합했을 때, Chloe T호의 빌지 배수 계통은 1975년 규칙의 요건을 초과했을 가능성이 높은 것으로 보였다. 면제가 필요하지 않았는데도 안전에 결정적인 계통에 대해 10년 넘게 아무런 이의 없이 면제가 주어졌을 가능성이 상당히 있다.
4.6.5 요약
Chloe T호는 적용되는 요건이나 지침에 따라 검사받지 않았다. 그 결과 선박의 UKFVC가 때때로 무효였을 가능성이 높으며, 안전에 결정적인 계통의 상태가 확인되어야 했던 대로 확인되지 않았다. 밸브 핸들에 접근할 수 있어야 한다는 요건은 집행되지 않았고 MCA의 기록은 자체 지침에 따라 작성되지 않았다.
검사 과정의 결함이 배관 파손에 얼마나 기여하였는지는 알 수 없다. MSIS 23은 배관이 만족스러운 상태임을 입증하는 것이 선주의 책임이라고 강조하며, MSIS 27은 선주가 MCA 검사관과 기관 계통 검사를 위한 5년 주기를 합의해야 한다고 명시한다.
그러나 주기관 해수 냉각 흡입 밸브를 닫을 수 있는 접근 가능한 핸들이 있었다면 이 사고의 결과에 상당한 차이를 가져왔을 수 있다. MCA 검사관들은 극히 어려운 과업에 직면해 있다. 그들에게는 매우 넓은 범위의 업무가 주어지며, 지침은 부분적으로 신뢰하기 어렵다. 검사와 점검 결과를 기록하는 체계는 비효율적이고 오류에 취약하다. 기록에는 이전 규칙의 면제를 계속 적용해야 하는지, 또는 선박의 상태가 체계적으로 점검되고 있었는지 판단하기에 충분한 세부 내용이 없었다. 문서에 실수가 있었음은 불가피하며, 선박의 일부가 의도한 만큼 상세하게 또는 자주 검사되지 않았을 가능성이 매우 높다.
5절 Audacious호/Chloe T호 유사 사고
5.1 어선 Vellee호의 침수와 침몰, 2011년 8월 6일
길이 19.8m의 트롤선 Vellee호는 항해 중 기관실이 침수되어 침몰하였다. MAIB 조사 보고서 No 1/2012는 선원들이 기관실에서 기어박스 높이 위로 침수된 물을 발견하였으나 해수 흡입 밸브가 물에 잠겨 있어 접근할 수 없었다고 밝혔다. 보고서는 물이 들어온 원인이 진행된 전해 부식으로 인한 해수 배관 또는 관련 부속품의 치명적인 파손이었을 가능성이 높다고 결론지었다.
5.2 영국 어선 안전 분석 1992 - 2006
2008년 11월 MAIB는 1992-2006년 기간의 영국 어선 사고, 손실, 사망 및 부상의 추세를 분석한 어업 안전 연구를 발간하였다. 이 연구는 15m-24m 구분에서 85척이 침수/침몰로 손실되었음을 밝혔다. 점진적 침수와 주기관 냉각 계통의 고장이 MAIB 데이터베이스에 침수 사고의 가장 흔한 원인으로 기록되어 있었다.
6절 논의
6.1 침수
Audacious호와 Chloe T호의 침수의 정확한 이유는 알려져 있지 않다. 그러나 사고 경위와 각 선박의 이력을 분석하면 두 침수 모두 발견되지 않은 부식으로 인해 해수 냉각 계통 배관이 파손되어 일어났음이 강하게 시사된다. 해수 배관의 부식 속도와 정도는 여러 가지 서로 다른 방법으로 영향을 줄 수 있으나, 어느 정도의 부식은 불가피하다.
6.2 예방
6.2.1 배관 열화
이러한 고장을 예방하는 유일한 방법은 해수 배관의 상태를 점검하는 체계적인 제도를 갖추고 배관이 파손되기 전에 교체하는 것이다. 배관은 보통 상당히 일정한 속도로 열화할 것으로 예상해야 하지만, (지락, 갈바닉 절연 누락 또는 소실된 아노드로 인한) 전위의 변화와 기타 금속학적 요인(오염되거나 정체된 물에 선박을 계류해 두는 것 등)이 극적인 변화를 일으킬 수 있다. 유속이 가장 높은 배관의 특정 구간도 다른 구간보다 부식 손상에 더 취약하다. 이러한 요인의 영향을 정확히 예측하는 것은 현실적이지 않으며, 정기적인 점검이 필수적이다.
6.2.2 검사와 점검
Audacious호와 Chloe T호 모두에서 일부 배관을 때때로 점검하고 교체하였다는 증거가 있었다. 그러나 이 사고들은 그것이 충분하지 않았음을 보여 준다. 어선의 검사와 점검에 대한 법정 요건은 광범위하다. 선박 소유자 또한 정비를 관리하고 검사를 준비할 상당한 책임이 있다. 이 보고서에서 앞서 설명한 모든 요건이 충족되었다면 이 두 사고가 모두 일어날 수 있었을지는 상상하기 어렵다. 따라서 Audacious호와 Chloe T호의 정비, 검사 및 점검상의 결함으로 인해 해수 계통의 열화가 발견되지 않은 채 진행되었다고 결론지을 수밖에 없다.
이 결론을 뒷받침하는 증거가 두 선박 모두에 있었다. 두 경우 모두에서 중간 점검의 누락과 갱신 검사 절차의 지연이 확인되었으며, 어느 선박도 MCA가 검사관에게 내린 지침에서 의도한 수준의 감독을 받았을 가능성은 낮다. 어느 선박에도 요구되는 정비 계획이 없었고, MCA 검사관과 합의한 체계적인 배관 점검 또는 교체 프로그램이 있었다는 증거도 없었다. 이런 종류의 정보를 담을 파일(기관용 CM 파일 계열)은 한 번도 작성된 적이 없었다. 검사 과정의 결함이 배관 파손에 얼마나 기여하였는지는 알 수 없다. MSIS 23은 배관이 만족스러운 상태임을 입증하는 것이 선주의 책임이라고 강조하며, MSIS 27은 선주가 MCA 검사관과 기관 계통 검사를 위한 5년 주기를 합의해야 한다고 명시한다. Audacious호의 경우에도 Chloe T호의 경우에도 이것이 이행되었다는 증거는 없었다.
또한 검사 요건이 엄격하고 효과적으로 적용될 수 있다는 것도 극히 가능성이 낮다. 망치 타격 시험과 압력 시험은 모두 어느 정도의 위험을 수반하였고, 어느 쪽도 전적으로 결정적인 시험 방법이 될 가능성은 낮았다. 특히 Chloe T호와 같은 선령과 형태의 선박에서 모든 배관을 이런 방식으로 충분히 시험할 수 있다는 것은 도저히 신뢰할 수 없다. 끝으로 정비와 검사 기록은 불완전하였다. 이로 인해 어느 배관이 언제 어떤 방법으로 점검되었는지 누구도 알 수 없었다. 기록에는 중요한 장비가 어디에 있는지, 또는 규칙의 면제를 계속 적용해야 하는지가 나타나 있지 않았다. 이러한 모든 요인을 감안하면 Audacious호와 Chloe T호의 해수 배관이 그토록 갑자기 파손될 수 있었다는 것은 놀라운 일이 아니다. 배관 계통의 모든 부분을 체계적으로 점검하고 그 상태를 기록하지 않는 한, 발견되지 않은 부식으로 인한 파손의 위험은 항상 존재할 것이다.
6.3 탐지
6.3.1 조기 경보
두 경우 모두 선원들은 빌지 경보가 아닌 다른 수단으로 기관실 침수를 알게 되었다. Audacious호에서는 CPP 계통의 예상치 못한 거동이, Chloe T호에서는 화재 경보가 그것이었다. 결과는 두 사고에서 같았다. 선원들이 문제를 알았을 때에는 이미 조치를 취하기에 너무 늦었다. 빌지 경보는 선원들에게 침수에 대한 충분한 경고를 주었어야 하였으나, 신호가 들리지 않았거나 경보가 가장 필요한 때 작동하지 않았기 때문에 실패하였다.
6.3.2 작업 관행
Audacious호의 당직자는 사고 당시 조타실에 있었어야 하였고 경보에 즉시 대응할 수 있었어야 한다. MAIB는 당직자가 자리에 없었던 사례를 많이 조사하였으며, 이는 어선과 소형 상선 사고에서 일관되게 나타나는 요인이다. 그러나 빌지 경보는 선박이 안벽에 접안해 있을 때, 아마도 선원들이 선내에서 자고 있는 동안에도 울릴 수 있다. 이러한 가능성은 비상 경보가 선박 전체에서 들려야 하며, 잠든 선원이 문제를 찾아 큰 비상 상황으로 발전하기 전에 대응할 수 있을 만큼 충분한 시간 안에 그를 깨울 수 있어야 한다는 요건을 강하게 뒷받침한다13. Chloe T호 기관실의 빌지 경보 센서 중 하나는 고장 난 상태였으나 사고 전에는 올바르게 작동하고 있었던 것으로 생각되었다. 그러나 이 센서는 계속 신뢰할 수 있게 작동한다고 크게 확신할 만큼 정기적으로 시험되지 않았다. 대부분의 경보 장치는 어느 시점에 고장 날 가능성이 있으며, 신뢰와 숙련을 얻는 유일한 방법은 경보를 정기적으로 시험하는 것이다. 이는 출항 전, 그리고 해상에서는 매일 시험해야 함을 의미한다.
13 MCA는 이전에 MAIB의 권고를 수용한 바 있다. 그 권고는 '길이 24m 초과 총톤수 500톤 미만의 모든 선박에 대해, 침수되면 선박의 부력과 복원성을 위협할 수 있는 기관실과 기타 주요 구획에 빌지 경보를 설치하도록 의무화하는 요건을 도입할 것. 이러한 경보와 기타 모든 비상 경보는 중앙 제어 장소에 사람이 없을 때 모든 거주 공간에서 울려야 한다. 선박의 정상 운용 모드에서 작동하는 것 외에도, 경보는 주 전원이 차단된 때에도 작동할 수 있어야 하며 잠든 선원이 적절히 대응할 수 있도록 충분한 시간 안에 그를 깨울 수 있어야 한다.'는 것이었으며, 2008년 11월 2일 헤이셤 항(Port of Heysham)에서 그래브 호퍼 준설선 Abigail H호가 침수·침몰한 사고에 뒤따른 것이다. 보고서 No 15/2009.
Audacious호와 Chloe T호의 선원들은 모두 기관실과 가동 중인 기계를 점검하는 정기적인 루틴을 갖고 있었다. 이는 좋은 관행이고 누설을 초기에 발견하는 데 도움이 될 수 있지만, 문제가 발생하는 바로 그때 기관 구역에 사람이 있다는 보장은 없다. 효율적인 경보 장치는 필수적이다.
6.4 비상 대응
6.4.1 침수에 대한 즉각적 대응
두 선박의 선원들은 모두 주기관 해수 냉각 흡입 밸브를 닫으려 해야 한다는 것을 알고 있었다. 기관실의 배치 때문에 밸브 핸들이 빠르게 물에 잠겨 어느 쪽도 그렇게 하지 못하였다. 침수 비상 시 밸브 핸들을 연장하거나 달리 원격으로 닫을 수 있어야 한다고 권고하는 지침이 오랜 기간에 걸쳐 충분히 발간되어 있다. 그러나 이는 자발적으로도, 법정 요건의 집행을 통해서도 이루어지지 않았다. 이 한 가지 쟁점 때문에 침수가 두 선박의 손실로 이어졌을 가능성이 상당히 높다. 기관실이 침수되기 시작할 때 닫을 수 있도록 해수 흡입 밸브에는 접근할 수 있어야 한다.
6.4.2 배수
고정식 펌프는 침수 속도를 감당하지 못하였다. 강력하고 독립적으로 동력을 공급받는 구난 펌프가 있었다면 선원들에게 대응할 시간을 더 주거나 침수를 억제하기까지 했을 수 있다. 그러나 MAIB가 실시한 다른 조사들14은 그러한 펌프를 사용하여 의도치 않게 치명적인 결과가 발생한 사례를 보여 주었다. 어선의 구난 펌프는 흔히 가솔린 기관으로 구동되며, 밀폐된 공간에서 사용하면 배기가스가 일산화탄소 중독을 일으킬 수 있다. Audacious호나 Chloe T호에서 유사한 펌프를 사용했다면 이를 기관실(또는 그 위의 거주구역)에 설치하였을 것이고 그 배기가스가 또 다른 비극을 초래했을 수 있음을 쉽게 상상할 수 있다.
6.4.3 복원성
Audacious호와 Chloe T호의 복원성 여유는 침수로 인해 빠르게 줄어들었다. 두 경우 모두 물이 기관실의 폭 전체에 걸쳐 유입되면서 자유표면 모멘트가 증가한 영향 때문이었다. 그물을 끌어 올리면서 복원성 여유는 더욱 잠식되었다. 다행히 선장이 이를 재빨리 알아차렸고 추가 문제를 막기 위해 그물을 풀어 내보냈다. 복원성의 저하는 침수가 발견된 직후 매우 빠르게 일어났고 선원들에게 더 큰 압박을 가하였다. 복원성 자료집을 비치해야 한다는 요건에도 불구하고, 선상의 누구라도 기관실이 침수되었을 때 선박이 똑바로 서 있거나 떠 있을 수 있는지 알았을 가능성은 낮다. Chloe T호는 선원들이 퇴선한 뒤에도 몇 시간 동안 떠 있었고, Audacious호도 선박의 수밀문을 닫았다면 더 오래 떠 있을 수 있었을 가능성이 있다. 선장들은 비상시 퇴선에 관해 최선의 결정을 내리는 데 도움이 되도록, 대규모 침수가 자기 선박에 미치는 영향을 이해해야 한다.
14 예: 2011년 8월 25일 애버딘(Aberdeen) 북북동 126해리에서 어선 Starlight Rays호의 선원이 사망한 사고에 대한 MAIB 조사 보고서. 보고서 No 15/2012.
6.4.4 퇴선
Chloe T호의 선원들은 (해상 생존 훈련을 포함한) 의무 훈련을 이수하였고, 정기적으로 비상 훈련을 실시하였으며, 침착하고 효율적으로 선박을 퇴선하였다. 그들은 자신들에 대한 위험을 최소화하였고, 무선기와 EPIRB를 잘 활용함으로써 응급 구조기관과 다른 선원들이 가능한 한 쉽게 자신들을 도울 수 있도록 하였다. Audacious호의 선원들은 준비가 덜 되어 있었다. EPIRB는 구명뗏목으로 가져갔지만, 선원들은 개인 소지품을 챙기러 선실로 돌아가고 값비싼 트롤 센서를 모으느라 불필요한 위험에 스스로를 노출시켰다. 구명조끼와 방수복은 무시되었고 구명뗏목 하나는 제대로 고정되지 않아 유실되었다. 이러한 문제 중 어느 것도 선원들의 안전한 구조에 영향을 주지 않은 것은 다행이었다. 겪은 문제들은 모든 선원이 적절한 훈련을 이수하고 비상시 올바르게 대응하는 데 도움이 되도록 정기적인 훈련을 실시하는 것이 중요함을 강조한다.
7절 안전 쟁점
7.1 침수의 원인
1. Audacious호와 Chloe T호에서 침수의 정확한 원인을 판단하는 것은 불가능하였으나, 두 경우 모두 가장 가능성 높은 이유는 주기관 해수 냉각 배관의 파손이라고 결론지었다. [2.4.1 Audacious, 4.2 Chloe T]
2. 해수 배관의 부식 손상 속도를 예측하는 것은 현실적이지 않으며, 정기적인 점검이 필수적이다. [6.2.1]
3. Audacious호와 Chloe T호의 정비, 검사 및 점검상의 결함으로 인해 해수 계통의 열화가 발견되지 않은 채 진행되었다고 결론지을 수밖에 없다. [6.2.2]
7.2 해수 배관의 상태 평가
1. Audacious호도 Chloe T호도 요구되는 정비 계획이나 체계적인 배관 점검 및 교체 프로그램이 있었다는 증거가 없었다. [6.2.2]
7.3 침수 탐지
1. 두 경우 모두 선원들은 빌지 경보가 아닌 다른 수단으로 기관실 침수를 알게 되었다. 빌지 경보는 선원들에게 침수에 대한 충분한 경고를 주었어야 하였으나, 신호가 들리지 않았거나 경보가 가장 필요한 때 작동하지 않았기 때문에 실패하였다. [6.3.1]
2. 비상시 경보가 작동할 것이라는 확신을 보장할 수 있도록, 빌지 경보는 출항 전, 그리고 이상적으로는 해상에서 매일 시험해야 한다. 경보가 선박 전체에서 들리고, 잠든 선원이 적절히 대응할 수 있도록 충분한 시간 안에 그를 깨울 수 있어야 한다는 주장에는 강력한 근거가 있다. [6.3.2]
7.4 침수 비상에의 대응
1. 수밀문은 침수가 발생했을 때 선박의 생존성을 높이기 위해 설치된다. Audacious호의 수밀문은 일상적으로 닫혀 있지 않았기 때문에 상황에 거의 도움이 되지 않았다. [2.4.4 Audacious]
2. 선상의 누구도 방법을 알지 못하였기 때문에 일반 용도 펌프는 Chloe T호 기관실의 물을 퍼 올리는 데 도움이 되도록 재구성되지 않았다. 빌지 펌프와 일반 용도 펌프를 함께 사용했다면 침수를 억제할 수 있었을 가능성이 있다. [4.4.1 Chloe T]
3. Audacious호와 Chloe T호의 선원들은 모두 침수 속도를 줄이기 위해 해수 흡입 밸브를 닫으려 해야 한다는 것을 알고 있었다. 기관실의 배치 때문에 밸브 핸들이 빠르게 물에 잠겨 어느 쪽도 그렇게 하지 못하였다. 기관실이 침수되기 시작할 때 닫을 수 있도록 해수 흡입 밸브에는 접근할 수 있어야 한다. [6.4.1]
4. 두 선박의 고정식 펌프는 침수 속도를 감당하지 못하였다. 독립적으로 동력을 공급받는 구난 펌프가 도움이 되었을 수 있다. 그러나 가솔린 또는 디젤 기관으로 구동되는 구난 펌프는 배기가스로 인한 일산화탄소 중독을 피하기 위해 극도로 주의해서 사용해야 한다. [6.4.2]
5. 어선 선장은 비상시 퇴선에 관해 최선의 결정을 내리는 데 도움이 되도록, 대규모 침수가 자기 선박에 미치는 영향을 이해해야 한다. [6.4.3]
6. Audacious호 선원 대다수는 안전 인식 훈련을 이수하지 않았다. 그들이 물에 들어가지 않고 구명뗏목에 타서 구조될 수 있었던 것은 다행이었으며, 상황이 달랐다면 구명조끼와 생존복 없이 그들의 생존 가능성은 크게 낮아졌을 수 있다. [2.5]
7. Audacious호와 Chloe T호가 퇴선된 방식의 차이는 모든 선원이 적절한 훈련을 이수하고 비상시 올바르게 대응하는 데 도움이 되도록 정기적인 훈련을 실시하는 것이 중요함을 강조한다. [6.4.4]
7.5 법정 검사와 점검의 실효성
1. 15-24m 규약은 선박을 검사와 중간 검사에 제시하는 것이 선주의 책임임을 분명히 하고 있다. 선주와 선장에게는 또한 선박이 감항성을 갖추고 안전하게 운항될 수 있도록 보장할 더 실무적인 책임이 있다. [2.6, 4.5.1]
2. 두 경우 모두에서 중간 점검의 누락과 갱신 검사 절차의 지연이 확인되었으며, 어느 선박도 MCA가 검사관에게 내린 지침에서 의도한 수준의 감독을 받았을 가능성은 낮다. [6.2.2]
3. 법정 검사 요건의 범위가 엄격하고 효과적으로 적용될 수 있다는 것은 극히 가능성이 낮다. [6.2.2]
4. 검사와 점검 기록은 불완전하여 어느 배관이 언제 어떤 방법으로 점검되었는지를 누구도 일상적으로 알 수 없게 하였다. [6.2.2]
5. 기록은 불완전하였고 중요한 장비가 어디에 있는지, 또는 규칙의 면제를 계속 적용해야 하는지가 나타나 있지 않았다. [6.2.2]
6. 배관 계통의 모든 부분을 체계적으로 점검하고 그 상태를 기록하지 않는 한, 발견되지 않은 부식으로 인한 파손의 위험은 항상 존재할 것이다. [6.2.2]
8절 조치 사항
8.1 다른 기관의 조치 사항
MCA는 다음을 하였다.
›2013년 3월 22일자로 '검사관 자문 고시(Surveyor Advice Note, SAN) 29', 제목 "선박 기관 냉각 및 해수 배관 계통 검사"를 발행하여 어선 배관 검사에 관해 검사관이 이용할 수 있는 조언을 갱신하였다.
Langdon and Philip는 다음을 하였다.
›자사의 다른 선박 선원들에게 출항 전과 해상에서 매일 모든 빌지 경보를 시험하도록 요구하였다.
›자사의 다른 선박들은 Chloe T호보다 해수 계통이 훨씬 단순하며 해수 계통 고장 시 흡입 밸브에 더 쉽게 접근할 수 있음을 확인하였다.
9절 권고 영국 해사연안경비청에 다음을 권고한다.
2013/249 다음을 보장하도록 어선에 대한 검사와 점검의 수행을 재검토할 것.
›범위가 신뢰할 만하며 실제로 달성할 수 있을 것.
›전체 범위가 일상적으로 적용될 것.
›기록이 정확하고 완전할 것.
2013/250 어선에 대한 검사와 점검의 일정을 관리하는 견고한 체계를 시행할 것. 이러한 체계는 검사나 점검 기한이 지난 선박을 쉽게 식별할 수 있어야 한다.
Deveron Fishing Company(Audacious호의 선주)에 다음을 권고한다.
2013/251 다음을 보장함으로써 자사가 운영하는 다른 모든 어선의 안전을 개선할 것.
›중간 점검을 실시할 것.
›선원이 의무 훈련을 이수하였을 것.
›조타실에서 지속적으로 당직을 유지할 것.
스코틀랜드 어민연맹(Scottish Fishermen's Federation), 전국어민단체연맹(National Federation of Fishermen's Organisations) 및 북아일랜드 수산생산자기구(Northern Ireland Fish Producers Organisation Limited)에 다음을 권고한다.
2013/252 이 사고들에서 얻은 교훈을 회원들에게 널리 알릴 것. 어선 운영자가 해수 배관을 철저히 점검하여 부식/침식을 초기에 확인해야 할 필요성에 특히 중점을 두어야 한다.
Card 1 Nautical Charts and Publications Up to date Signalling Lamp 1
Book (or Roll Test report) On board Safety Harnesses 2 Medical Stores and Kit to current
schedule On board Waterproof Torch Note; Existing vessels may still comply with the requirements of the
Vessels (Safety Provisions) Rules 1975 as amended
SURVEY / INSPECTION Hull YNN/A , condition of vessel or Lightship Check carried out Hull condition, external, internal and arrangements Decks, Bulkheads, frames condition
Lifeboats, Rescue Boats condition of boats Equipment in boats to scale required and in date Embarkation arrangements and appliances for each survival craft including relevant tests and overboard lights
Each inflatable , the and float-free arrangements. Note; reduced strength HRU used for smaller liferafts
Lifebuoys, self-igniting lights, self-activating smoke signals and buoyant lines, correctly marked /s, main, Hydrants, hoses and nozzles, Each , operated separately - jet of water produced at any part of the ship whilst required pressure is maintained in fire main
Emergency instructions available for each person on board. Copies of suitably up-dated posted in conspicuous places and in a language understood by all persons on board and posters or signs in the vicinity of survival craft and their stations
Safety of operation of , winches, wires, blocks, nets, lines etc. ( & Regs) Ease of access to safety equipment doors, condition Hatches and Skylights Scuttles and Flush Scuttles Ventilators Air Pipes Freeing Ports Ladder/Boarding arrangements Gas Cylinders, storage, safety precautions
SURVEY / INSPECTION Wheelhouse/ Y N N/A Windows, condition, clear view? Doors, condition have received appropriate onboard training Instructions for on-board maintenance of are on board. Inspect any immersion suits, thermal protective aids etc.
,
rate of revolution indicator, variable
and operational mode indicator.
,
,
,
.
sea
cocks and their ease of operation (above floor plates)
부록 B 웰(well)형 기관 설계의 단면도 (Audacious호)
부록 C 2008년 12월 발급 UKFVC (Audacious호)
부록 D MCA 만재흘수선 검사 보고서 2011년 7월 (Audacious호)
부록 E 길이 15~24미터 어선 검사/점검 비망록(Aide-Mémoire) (MCA)
Rev 1 2007년 9월요구되는 점검 항목
구명조끼, 등화 포함 인당 1개 + 예비 2개
구명뗏목 - 해역 A1용, 1척만 탑재할 수 있는 경우 구명뗏목 - 해역 A1 및 A2용 및 모든 빔 트롤선 구명부환, 등화 및 연기 신호가 있는 것 1개, 18 m 부양 줄이 있는 것 1개
구조적 방화 설비가 제공되지 않은 경우 조리실용 고정식 소화 장치 동력 구동 소방 펌프 및 호스 - 압력 2 kg/m에서 15 m /hr
거주구역에 적합한 소화기 3
기름 화재에 적합한 소화기 2
소화기 용량 물 - 9 리터, 포말 - 9 리터, CO2 - 3 kg, 분말 - 4.5 kg, 다목적 - 9 리터 액체 소화기에 상당
방화 담요 1LPG 불꽃 소실 장치 및 저압 차단 밸브LPG 가스 탐지 및 경보 장치 1빌지 펌프 2빌지 경보, 어창 및 기관 구역 2항해등 및 음향 신호 적합VHF 무선기 휴대용 1위성 EPIRB 1나침반 및 자차표 1항해 해도 및 간행물 최신본신호등 1복원성 자료집(또는 횡요 시험 보고서) 선상 비치
안전 하네스 2
현행 MSN 일정표에 따른 의료품 및 키트 선상 비치
방수 손전등 비고: 기존 선박은 개정된 어선(안전 규정) 규칙 1975의 요건을 계속 충족할 수 있다.
검사 / 점검
선체 예 아니오 해당 없음 복원성, 선박 상태 경사 시험 또는 경하 상태 점검 실시 선체 상태, 외부, 내부 계류 및 묘박 설비 갑판, 격벽, 늑골 상태
갑판
구명정, 구조정 - 보트의 상태 요구되는 규모의 정 내 장비로서 유효기간 이내일 것 각 생존정의 승선 설비와 진수 장치(관련 시험 및 선외 등화 포함)
각 팽창식 구명뗏목, 수압이탈장치 및 자유 부양 장치. 비고: 소형 구명뗏목에는 강도를 낮춘 HRU를 사용 구명부환, 자기 점화등, 자동 작동 연기 신호 및 부양 줄이 올바르게 표시되어 있을 것
소방 펌프, 소방 주관, 소화전, 호스 및 노즐, 각 펌프를 별도로 가동 - 소방 주관에서 요구 압력이 유지되는 동안 선박의 어느 곳에서도 물줄기가 나올 것
선상의 모든 사람이 이용할 수 있는 비상 지침. 적절하게 갱신된 비상 배치표 사본이 눈에 잘 띄는 장소에 게시되어 있고 선상의 모든 사람이 이해하는 언어로 되어 있을 것, 그리고 생존정과 그 진수 장소 부근에 포스터 또는 표지가 있을 것
휴대식 및 비휴대식 소화기 - 올바른 종류, 상태, 적절한 정비, 위치 어구, 윈치, 와이어, 블록, 그물, 줄 등의 운용 안전(LOLER 및 PUWER 규칙)
안전 장비로의 접근 용이성수밀문, 상태해치 및 천창현창 및 평면 현창통풍구공기관방수구도선사용 사다리/승선 설비
가스 실린더, 보관, 안전 예방 조치
검사 / 점검 조타실/선실 예 아니오 해당 없음 창문, 상태, 시야 확보 여부 문, 상태 선원이 적절한 선상 훈련을 받았을 것 구명설비의 선상 정비 지침이 선상에 있을 것. 방수복, 보온 보호구 등을 점검할 것.
구명조끼(호루라기, 재귀반사 재료 및 등화 포함) 선주와 선원이 작동하는 구명조끼를 항상 착용하도록 권장할 것(상시 착용 부력 장비)
자기 나침반의 잔여 자차표 또는 곡선이 제공되어 있을 것
모든 항해 장비의 운용 및 해당되는 경우 정비 매뉴얼이 제공되어 있을 것
예정 항해에 필요한 해도와 항해 간행물이 비치되고 갱신되어 있을 것
양방향 VHF 무선전화 장치의 작동
EPIRB의 작동 - 연례 시험 증명서가 제공되어 있을 것
항해등, 형상물 및 음향 신호 장비
낙하산 신호탄이 유효기간을 넘지 않았을 것
수동 신호탄이 유효기간을 넘지 않았을 것
연기 신호가 유효기간을 넘지 않았을 것
줄 발사 로켓과 격발기가 유효기간을 넘지 않았을 것
설치된 경우 화재 탐지 및 경보 장치의 점검 및 시험 해당되는 경우 자기 나침반, 자이로 컴퍼스, 레이더 설비, 자동레이더플로팅장치, 음향측심기, 속력 및 거리 지시기, 타각 지시기, 프로펠러 회전수 지시기, 가변피치 프로펠러의 피치 및 운전 모드 지시기. 선박자동식별장치, 항해자료기록장치, ECDIS, GPS.
해당되는 경우 조리실용 고정식 소화 장치와 그 작동 수단이 명확히 표시되어 있을 것
조리실의 방화 담요
쓰레기 처리 설비LPG 가스 탐지 및 경보 장치, 상태 및 시험작업장 갑판톤수밸브
Rev 1 2007년 9월
검사 / 점검 일반 예 아니오 해당 없음 안전 표지 SOLAS 1 포스터 안전 벨트/하네스 비상 배치표 - 선원 5명 초과 기관 구역 주기관 및 보조기관, 상태, 방호 장치, 배기, 고온 표면 노출 없음, 연료관
원격 전기 정지 장치
연료유, 윤활유 및 기타 인화성 기름에 대한 설비. 연료유, 윤활유 및 기타 인화성 기름이 들어 있는 탱크의 원격 급폐쇄 밸브 수단의 작동
빌지 배수 - 빌지 펌프와 빌지 경보의 시험
빌지, 상태, 기름이 선외로 배출되지 않을 것. 유성 폐수 처리 설비 기관용 고정식 소화 장치: CO2/FM 200 등의 용량이 점검되었을 것. 분배 배관이 막히지 않음이 입증되었을 것
압축 공기 계통
배관, 고정 클립, 선체 관통 부속품(skin fitting), 시코크 및 그 조작 용이성(바닥판 위에서)의 상태
전기 계통 - 발전기, 전동기 등
전기 케이블 - 상태, 단단히 고정, 전기적으로 안전 축전지, 상태(비상용 및 무선용)
비상 탈출로, 장애물 없음, 명확히 표시격벽, 늑골, 상태방화문, 플랩 등의 상태조타 장치, 상태, 작동 시험계획 정비 기록 - MT 4 설문 참조
화재 위험 및 위해 요소
선외 검사(중간/갱신) 예 아니오 해당 없음
선체 상태 강 - 초음파 시험 및 보고서
빌지 킬
해수 박스(sea chest)
희생 양극
목재 - 판재, 못, 코킹 등의 상태 알루미늄 - 상태 GRP - 상태, 젤코트, 손상, 삼투 등 선미 장치 상태 보고서 간극 윤활 프로펠러 코트 노즐
조타 장치 상태 방향타 방향타 축 간극해수 흡입구 및 배출 밸브/코크의 상태흘수 표시 - 상태/정확도
닻 및 닻줄 상태
검사 완료 예 아니오 해당 없음
검사/점검을 완료하기 전에 의문이 있으면 어선 수석 검사관 또는 현지 해사사무소에 연락하여 조언을 구할 것
UKFVC 발급 또는 이서; 점검 보고서를 선주/선장에게 교부 장비 기록(점검표)을 선주/선장에게 교부
문서 번호
MSF 5550 길이 15~24미터 어선 검사/점검 비망록(Aide-Memoire) (15 - 24 m 안전작업 실무규약 기준)
선박 이름 날짜 개정
16/09/09
증서 및 기록 예 아니오 해당 없음 영국 어선 증서의 유효성(중간 검사를 실시하였는가?) 자체 증명 양식 선주가 매년 서명 적절한 간격으로 무선 검사 실시
Discuss use of lifelines/harnesses/belts
Annex F record (Chloe T)
UKOT lnspections!Sul"teys @MIIti?hi GJOUP 10 . Official !lumber Inspection TYIM' IWalC:h llw 30199 30088 ANGEL EMIEL 810739 01112/1937 hl conjunctcon wrth a SUM!)' 30199 300.$8 ANGEL EMlEL 81 0739 11i 01 f 1 ~S8 tn COfljunclion 111-il.h a sut\'ey ( Viewlnspecbon [ 30199 30088 ANGELEM:EL 8107.39 2710311998 In ccnjunction with a survey I Viewlns(){iction f -11883 30088 CHLOE I 810739 01106/2000 Coru:entraced ( View lnsp.e ction I 41883 30088 CHLOE i 810739 24111~01 Tatg~ [ V11?wlnspeclion I .11883 3ooaa CHLOE T 810739 19103/20i>2 In conjunction 'IIIith a suwey [ Viewlnspection I 63534 30088 CHLOET 610739 25f11i2005 In conjunction \Wth a SllMly ( Viewlnspe.clion ) 63534 30088 CHLOE I 810739 08111/2007 Targ~tad ( VJe\VIMpeC1ion J 6353A 30088 CHLOE. T 810739 2a!OS/200S Targeted [ Viewlnspetlxon I 6353~ 30088 CHLOET 810739 19i01/2011 In coojunellon \'lith a suro"ey ( Viewlnspecoon I 8353~ 301188 CHLOET 810739 0210212012 Targeted ( Vi&wlnspeclion ) 63534 30088 CHLOE T 810739 07JOcJ2012 Targ~ted I Vie\vlnspecbcn }~lAS Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1 186 UK & DT Inspection/Survey Details NextiD Group ID 30088 Official Number 810739 Sign MLVY3 Ship Type F1 - - Flag 670 - UNITED KINGDOM Class. Society 0- NONE OWner Year of Build 1968 Kw 455 Length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 07/06/2012 Detained? N UK Class Code X Dead Weight 000136 Input Date 11/06/2012 Release Date Country UNITED KINGDOM Place NeWlyn Inspection Targeteci Inspected at N Type Sea? MACRIS Codes Comments -PLYMOUTH MARINE OFFICE Ship Actions Inspection has no ship actions Survey Details Inspection has no surveys Survey Details Inspection has no ILO SurveyCertificate Details \ •. ·~ / .. • Last i ' '·. '+'•. ·~· ·· .. · I· Date of ; Expiry Surv Certificate Issued by · lssua Date Date FVC 21/07/2011 24/02/2016 Deficiency Details • Su'rveyor's Description . . 0 Class A to be fitted within 2 weeks Regulation Ref Last Last Survey Suniey Country Place 00 000 Relates to survey? Last Survey Issue Authority NONE • 16~lAS Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1 186 UK & DT Inspection/Survey Details Next ID Group ID 30088 Official Number 810739 Sign MLW3 Ship Type F1 - - Flag 670- UNITED KINGDOM Class. Society 0 • NONE OWner Year of Build 1968 Kw 455 length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 02/02/2012 Detained? N UK Class Code X 0001 36 Input Date 23/02/201 2 Release Date Country NETHERLANDS Place DEN HELDER Inspection Targeted Type MACRIS Codes Inspected at N Sea? Comments F~SO Newlyn • 15-24m FV target Ship Actions Inspection has no ship actions Survey Details Inspection has no surveys Survey Details Inspection has no ILO SurveyCertificate Details Date of Certificate Issued by Issue Expiry Date FVC UNITED KINGDOM 21/03/2011 24/02/2016 Deficiency Details • 's Description 1330 OLD winch and casing to be cleared from vessel 988 under winch to be verified as sound 1330 New winch and casing to be fitted weights of new installation to be provided 930 to verify any potential changes to vessels 1150 recommend knuckles on gantry renewed Last· Surv Date ·o;- Last Last·. Survey survey Country Place 00 000 Last Survey Issue Authority NONE~lAS UK & DT Inspection/Survey Details Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1186 Next ID Ship Type F1 - - Flag 670 - UNITED KINGDOM Class. Society 0 - NONE Group ID 30088 Official Number 810739 Sign MLVY3 Owner Year of Build 1968 Kw 455 Length(m) 23.55 UK Class Code X Dead Weight 000136 ----- ----- -------------------------------- -----------------Inspection Details Marine Office Plymouth Inspection Date 19/01/2011 Detained? N Country UNITED KINGDOM Place Newlyn Inspection In conjunction With a Type survey MACRIS Codes Input Date 23/02/2011 Release Date Inspected at N Sea? Comments Plymouth MArine Office Ship Actions Inspection has no ship actions Survey Details Survey Type Survey Description , · . FVC(R) () Survey Details Inspection has no ILO SurveyCertificate Details Date of Certificate Issued by Issue Expiry Date FVC UNITED KINGDOM 01/02/2007 24/02/2011 Deficiency Details • 's Description 1288 Freeing Ports to /renew (4) 983 Repair as necessary 983 Repairs to top rail of bulkwark required 1240 Ensure all dogs free 1270 Ensure all door dogs free 743 All flaps and vents to be in good working order 988 Renew in net store 988 De- scale and coat tank in net store 741 Fuel shutoffs to prove 950 Electrical condition report I megga test to provide 1060 Prove all alarms 983 Vessel to be slipped within one month for and any remedial repairs 930 Light-ship check_ to carried out to verify vessel 1541 to be swung and card displayed 399 to be exercised at emergency drfll and 1560 New local chart required showing revised s 99 1570 2011 Almanac required s 99 915 Winch stops to mark s 99 660 locker to mark s 99
›- ~lAS UK & DT Inspection/Survey Details Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1186 Next ID Ship Type F1 - - Flag 670 - UNITED KINGDOM Class. Society 0 - NONE Group ID 30088 Official Number 810739 Sign MLVY3 Owner Year of Build 1968 Kw455 Length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 28/05/2008 Detained? N UK Class Code X Dead Weight 000136 Input Date 03/06/2008 Release Date Country UNITED KINGDOM Place Newlyn Inspection Tar eted Type g MACRIS Codes Inspected at N Sea? Comments - Plymouth MO Ship Actions Inspection has no ship actions - ------------------------------ Survey Details Inspection has no surveys Survey Details Inspection has no ILO Survey
Certificate Details ... , ,. . ',: f · · ' Date of ·, Expiry Certificate Issued by Issue . . · Date FVC UNITED KINGDOM 01/02/2007 24/0212011 Deficiency Details • 660 's Description Constant due for service Emergency exit /escape from - renew seal Dogs - doors .to - free up Last Surv Date L~~/· :.·:~. Survey Country Last Survey Place Relates to survey? Last Survey Issue Authority NONE~lAS UK & DT Inspection/Survey Details Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1186 NextiD Ship Type F1 - - Flag 670 - UNITED KINGDOM Class. Society 0- NONE Group ID 30088 Official Number 810739 Sign MLVY3 Owner Year of Build 1968 Kw 455 Length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 08/11/2007 ' Detained? N UK Class Code X 000136 Input Date 04/1212007 Release Date Country UNITED KINGDOM Place Newlyn Inspection Tar eted Type g MACRIS Codes Inspected at N Sea? Comments - FVSo Newlyn Ship Actions Inspection has no ship actions Survey Details Inspection has no surveys Survey Details Inspection has no ILO SurveyCertificate Details FVC UNITED KINGDOM 01/0212007 24102/2011 00 000 NONE Deficiency Details tfmJ 's Description 1410 Renew o Ring seal 690 renew /replace line throwers 699 Renew markers 1671 Renew 983 Renew anodes as necessary Regulation Rof Relatos to survey? f$Jt.],t)
~lAS UK & DT Inspection/Survey Details Ship Details Ship ID 63534 Ship Name CHLOE T Number 0000000 FV Number PZ1186 NextiD Ship Type F1 - - Flag 670 - UNITED KINGDOM Class. Society 0 - NONE Group ID 30088 Official Number 810739 Sign MLVY3 Owner Year of Build 1968 Kw 455 Length(m) 23.55 Inspection Details Marine Office Plymouth Inspection Date 25/11/2005 Detained? N Country UNITED KINGDOM Place Newlyn Inspection In conjunction with a Type survey MACRI$ Codes Comments Ship Actions UK Class Code X Dead Weight 000136 Input Date 30/11/2005 Release Date Inspected at N Sea? Inspection has no ship actions Survey Details Survey Type Survey Description · . . FVA(A) Category A Survey - Fishing Vessel (ANNUAL) Survey Details Inspection has no ILO SurveyCertificate Details Date of Certificate ISSlled by Issue Expiry Date Last Last Last · · Surv Survey Survey Date Country Place FVC UNITED Kl NGDOM 08/11/2002 24/02/2006 00 000 Deficiency Details • .· - . . ' . 's Description· . ·. ·, , . · , ' I • • •' ~ ' • .. ' ' • • 1560 up to date charts to provide 1570 2006 nautical almanac required 660 Ufejacket lights to renew 2099 Sol as 1 emergency signals chart to display 690 Line throwers 2 ro re furbish 1671 to renew 715 to service and cetify 1541 to swing and cerd to display 1620 Radio survey to conduct 371 Medical kit to service and certify 637 Provide man over board retrieval system 660 Mark locker 999 box coooling pipe renew as discussed 520 VArious lights to secure /shade 945 Test all emergency lighting 1099 Fit 2nd independent alarm in engine room 1099 prove Engine room and bilge alarms 741 Mark and Test all fuel shutoffs 1260 toilet scuttle dead light to free 1270 All door dogs to free up 1270 re rubber doors as necessary 999 Open up chain locker for inspection 986 stanchions to fair as necessary 930 Conduct lightship check to verify vessel 983 Carry out hul survey and remedy faults Regulation Ref Relates to survey? s s s s s s s s s s s s s s s s s s s s s s s s s Last Survey Issue Authority NONE • 99as required 1286 Mark location of sea cocks in s 99 room ,155.0 Pr9ve, navfgation lights a'nd liorn s 17 1551 Sight aldi lamp s 99 936 Sight e~etgen~ ste~ring ·· s 10 190 official entries to be maintained s 99 940 Fuel tank to be inspected internally s 99 when opened up
등록 증서의 유효성 비고: 소유권 변경 및/또는 길이, 기관 변경 등 선박 개조가 있는 경우 등록 증서를 갱신/수정해야 한다
선원 훈련 증명서의 유효성 기본 안전 인식 해상 생존 소화 응급 처치 소방 설비, 구명뗏목 등에 대한 정비 증명서의 유효성 위험성 평가 사본이 선상에 있거나 위험성 평가 폴더에서 확인할 수 있을 것 비고: 소유권 변경 또는 조업 방식 변경 시 수정된/새로운 위험성 평가가 필요하다
새로 설치된 장비가 현행 규칙에 부합하고 목적에 적합한지 등. 지난 검사 이후 고정식 소화 장치나 휴대식 소화기를 작동시켜야 했던 화재가 선상에서 발생한 적이 있는가;
안전 훈련이 실시되고 기록되었을 것 집중 캠페인 또는 점검에 대한 요건이 있었다면 확인되었을 것 - 별도 지침 참조 구명줄/하네스/벨트의 사용에 관해 논의할 것
부록 F SIAS 기록 (Chloe T호)
UKOT lnspections!Sul"teys @MIIti?hi GJOUP 10 . 공식 !lumber 점검 TYIM' IWalC:h llw 30199 30088 ANGEL EMIEL 810739 01112/1937 hl conjunctcon wrth a SUM!)' 30199 300.$8 ANGEL EMlEL 81 0739 11i 01 f 1 ~S8 tn COfljunclion 111-il.h a sut\'ey ( 점검 보기 [ 30199 30088 ANGELEM:EL 8107.39 2710311998 In ccnjunction with a survey I Viewlns(){iction f -11883 30088 CHLOE I 810739 01106/2000 Coru:entraced ( View lnsp.e ction I 41883 30088 CHLOE i 810739 24111~01 Tatg~ [ V11?wlnspeclion I .11883 3ooaa CHLOE T 810739 19103/20i>2 In conjunction 'IIIith a suwey [ Viewlnspection I 63534 30088 CHLOET 610739 25f11i2005 In conjunction \Wth a SllMly ( Viewlnspe.clion ) 63534 30088 CHLOE I 810739 08111/2007 Targ~tad ( VJe\VIMpeC1ion J 6353A 30088 CHLOE. T 810739 2a!OS/200S Targeted [ Viewlnspetlxon I 6353~ 30088 CHLOET 810739 19i01/2011 In coojunellon \'lith a suro"ey ( Viewlnspecoon I 8353~ 301188 CHLOET 810739 0210212012 Targeted ( Vi&wlnspeclion ) 63534 30088 CHLOE T 810739 07JOcJ2012 Targ~ted I Vie\vlnspecbcn } ~lAS 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1 186 UK & DT 점검/검사 세부 정보 NextiD 그룹 ID 30088 공식 번호 810739 호출부호 MLVY3 선종 F1 - 어선 - 강철 선적국 670 - 영국 선급 0 - 없음 OWner 건조 연도 1968 Kw 455 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 07/06/2012 억류 여부 N UK 분류 코드 X 재화중량 총톤수 000136 입력일 11/06/2012 해제일 국가 영국 장소 뉴린(NeWlyn) 점검 표적 점검 해상 점검 여부 N 유형 MACRIS 코드 비고 -PLYMOUTH MARINE OFFICE 선박 조치 점검에 따른 선박 조치 없음 검사 세부 정보 점검에 검사 없음 ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 \ •. ·~ / .. • 마지막 i ' '·. '+'•. ·~· ·· .. · I· 발급일 만료일 검사 증서 발급 기관 발급일 FVC 영국 해사연안경비청 21/07/2011 24/02/2016 결함 세부 정보 • 검사관 설명 . . 0 Class A AIS는 2주 이내에 설치할 것 규정 참조 마지막 마지막 검사 검사 국가 장소 00 000 검사와 관련됨? 마지막 검사 발급 기관 없음 • 16 ~lAS 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1 186 UK & DT 점검/검사 세부 정보 Next ID 그룹 ID 30088 공식 번호 810739 호출부호 MLW3 선종 F1 - 어선 - 강철 선적국 670- 영국 선급 0 • 없음 OWner 건조 연도 1968 Kw 455 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 02/02/2012 억류 여부 N UK 분류 코드 X 재화중량 총톤수 0001 36 입력일 23/02/201 2 해제일 국가 네덜란드 장소 덴헬더르(DEN HELDER) 점검 표적 유형 MACRIS 코드 해상 점검 여부 N 비고 F~SO Newlyn • 15-24m 어선 표적 선박 조치 점검에 따른 선박 조치 없음 검사 세부 정보 점검에 검사 없음 ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 증서 발급일 발급 기관 만료일 FVC 영국 21/03/2011 24/02/2016 결함 세부 정보 • 검사관 설명 1330 기존 윈치와 케이싱을 선박에서 제거할 것 988 윈치 아래 갑판이 견고한지 확인할 것 1330 새 윈치와 케이싱을 설치할 것, 새 설치물의 중량을 제공할 것 930 선박 복원성에 잠재적 변화가 있는지 확인하기 위함 1150 갠트리의 데릭 너클을 교체할 것을 권고 마지막· 검사 일자 ·o;- 마지막 마지막·. 검사 검사 국가 장소 00 000 마지막 검사 발급 기관 없음
~lAS UK & DT 점검/검사 세부 정보 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1186 Next ID 선종 F1 - 어선 - 강철 선적국 670 - 영국 선급 0 - 없음 그룹 ID 30088 공식 번호 810739 호출부호 MLVY3 Owner 건조 연도 1968 Kw 455 길이(m) 23.55 UK 분류 코드 X 재화중량 총톤수 000136 ----- ----- -------------------------------- -----------------점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 19/01/2011 억류 여부 N 국가 영국 장소 뉴린(Newlyn) 점검 검사와 병행 유형 MACRIS 코드 입력일 23/02/2011 해제일 해상 점검 여부 N 비고 Plymouth MArine Office 선박 조치 점검에 따른 선박 조치 없음 검사 세부 정보 검사 유형 검사 설명 , · . FVC(R) 영국 어선 증서(갱신) ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 증서 발급일 발급 기관 만료일 FVC 영국 01/02/2007 24/02/2011 결함 세부 정보 • 검사관 설명 1288 방수구(4개)를 분해 점검/교체할 것 983 필요한 대로 불워크를 수리할 것 983 불워크 상부 레일 수리 필요 1240 모든 해치 도그가 자유롭게 움직이도록 할 것 1270 모든 문 도그가 자유롭게 움직이도록 할 것 743 모든 방화 플랩과 통풍구가 양호한 작동 상태일 것 988 그물 창고의 목재 갑판을 교체할 것 988 그물 창고의 탱크의 녹을 제거하고 도장할 것 741 연료 차단 장치를 시험하여 입증할 것 950 전기 상태 보고서 / 절연 저항(megga) 시험을 제공할 것 1060 모든 기관 경보를 시험하여 입증할 것 983 선박은 선체 검사와 필요한 보수 수리를 위해 1개월 이내에 상가(上架)할 것 930 선박 복원성을 확인하기 위해 경하 상태 점검을 실시할 것 1541 나침반을 스윙(swing)하고 자차표를 게시할 것 399 선원은 비상 훈련과 묘박 훈련을 받을 것 - MCA가 입회할 것 252 선원 자격을 확인할 것 699 구명설비의 정비 일자와 증명서를 제공할 것 371 응급처치 키트 증명서 사본을 제공할 것 199 등록 증서 사본을 제공할 것 999 위험성 평가를 확인할 것 1270 문과 해치 실(seal)을 필요에 따라 교체할 것 1275 연돌 갑판의 회전식 통풍구를 교체할 것 1240 부식된 탈출 해치 코밍을 수리할 것 945 탈출 트렁크의 비상등을 수리할 것 915 탈출 해치를 표시할 것 915 배터리 부근에 금연 표지 필요 연돌 마지막 마지막 :·-. 마지막 검사 검사 일자 국가 ... 장소 00 000 s s s s s s s s s s s s s s s s s s s s s s s s s s 마지막 검사 발급 기관 없음
연돌 1560 개정된 TSS를 보여 주는 새 현지 해도 필요 s 99 1570 2011년 연감(Almanac) 필요 s 99 915 윈치 정지 장치를 표시할 것 s 99 660 구명조끼 보관함을 표시할 것 s 99
›- ~lAS UK & DT 점검/검사 세부 정보 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1186 Next ID 선종 F1 - 어선 - 강철 선적국 670 - 영국 선급 0 - 없음 그룹 ID 30088 공식 번호 810739 호출부호 MLVY3 Owner 건조 연도 1968 Kw455 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 28/05/2008 억류 여부 N UK 분류 코드 X 재화중량 총톤수 000136 입력일 03/06/2008 해제일 국가 영국 장소 뉴린(Newlyn) 점검 Tar eted 유형 g MACRIS 코드 해상 점검 여부 N 비고 - Plymouth MO 선박 조치 점검에 따른 선박 조치 없음 - ------------------------------ 검사 세부 정보 점검에 검사 없음 ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 ... , ,. . ',: f · · ' 발급일 ·, 만료일 증서 발급 기관 . . · 일자 FVC 영국 01/02/2007 24/0212011 결함 세부 정보 • 660 검사관 설명 상시 착용 구명조끼 정비 시기 도래 거주구역의 비상구/탈출구 - 해치 실(seal) 교체 도그 - 쉘터 갑판 문 - 자유롭게 할 것 마지막 검사 일자 L~~/· :.·:~. 검사 국가 마지막 검사 장소 검사와 관련됨? 마지막 검사 발급 기관 없음
~lAS UK & DT 점검/검사 세부 정보 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1186 NextiD 선종 F1 - 어선 - 강철 선적국 670 - 영국 선급 0- 없음 그룹 ID 30088 공식 번호 810739 호출부호 MLVY3 Owner 건조 연도 1968 Kw 455 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 08/11/2007 ' 억류 여부 N UK 분류 코드 X 재화중량 총톤수 000136 입력일 04/1212007 해제일 국가 영국 장소 뉴린(Newlyn) 점검 Tar eted 유형 g MACRIS 코드 해상 점검 여부 N 비고 - FVSo Newlyn 선박 조치 점검에 따른 선박 조치 없음 검사 세부 정보 점검에 검사 없음 ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 FVC 영국 01/0212007 24102/2011 00 000 없음 결함 세부 정보 tfmJ 검사관 설명 1410 o링 선미 실(stern seal)을 교체할 것 690 줄 발사 장치를 교체할 것 699 사람이 물에 빠짐 표지를 교체할 것 1671 EPIRB HRU를 교체할 것 983 필요에 따라 아노드를 교체할 것 규정 참조 검사와 관련됨? f$Jt.],t)
~lAS UK & DT 점검/검사 세부 정보 선박 세부 정보 선박 ID 63534 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1186 NextiD 선종 F1 - 어선 - 강철 선적국 670 - 영국 선급 0 - 없음 그룹 ID 30088 공식 번호 810739 호출부호 MLVY3 Owner 건조 연도 1968 Kw 455 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 25/11/2005 억류 여부 N 국가 영국 장소 뉴린(Newlyn) 점검 검사와 병행 유형 MACRI$ 코드 비고 선박 조치 UK 분류 코드 X 재화중량 총톤수 000136 입력일 30/11/2005 해제일 해상 점검 여부 N 점검에 따른 선박 조치 없음 검사 세부 정보 검사 유형 검사 설명 · . . FVA(A) 갑 구분(Category A) 검사 - 어선(연례) ILO 검사 세부 정보 점검에 ILO 검사 없음
증서 세부 정보 증서 발급일 발급 기관 만료일 마지막 마지막 마지막 · · 검사 검사 검사 일자 국가 장소 FVC 영국 08/11/2002 24/02/2006 00 000 결함 세부 정보 • .· - . . ' . 검사관 설명· . ·. ·, , . · , ' I • • •' ~ ' • .. ' ' • • 1560 최신 해도를 제공할 것 1570 2006년 항해 연감 필요 660 구명조끼 등화를 교체할 것 2099 SOLAS 1 비상 신호 도표를 게시할 것 690 줄 발사 장치 2개를 재정비할 것 1671 EPIRB HRU를 교체할 것 715 화재 탐지 장치를 정비하고 증명할 것 1541 나침반을 스윙하고 자차표를 게시할 것 1620 무선 검사를 실시할 것 371 의료 키트를 정비하고 증명할 것 637 사람이 물에 빠졌을 때의 구조 장치를 구비할 것 660 구명조끼 보관함을 표시할 것 999 기어박스 냉각관을 협의한 대로 교체할 것 520 기관실의 각종 등을 고정/가릴 것 945 모든 비상 조명을 시험할 것 1099 기관실에 두 번째 독립 빌지 경보를 설치할 것 1099 기관실과 어창의 빌지 경보를 시험하여 입증할 것 741 모든 연료 차단 장치를 표시하고 시험할 것 1260 화장실 현창 데드라이트를 자유롭게 할 것 1270 모든 문 도그를 자유롭게 할 것 1270 필요에 따라 문 고무 패킹을 교체할 것 999 닻줄 창고를 열어 점검할 것 986 불워크 스탠션을 필요에 따라 바로잡을 것 930 선박 복원성을 확인하기 위해 경하 상태 점검을 실시할 것 983 선체 검사를 실시하고 결함을 시정할 것 규정 참조 검사와 관련됨? s s s s s s s s s s s s s s s s s s s s s s s s s 마지막 검사 발급 기관 없음 • 99 필요에 따라 1286 기관실 내 시코크 위치를 표시할 것 s 99 ,155.0 항해등과 경적을 시험하여 입증할 것 s 17 1551 앵커 등 확인 s 99 936 비상 조타를 확인할 것 s 10 190 공식 항해일지 기재를 유지할 것 s 99 940 연료 탱크를 열었을 때 내부를 점검할 것 s 99
650 Two lifebuoys to refurbish 660 Ufejacket light batteries to renew 699 Dispose of old linethrower rockets 699 Investigate stowage of lifeja9kets in more accessible space 745 All vents on
to
overhaul
745 Test all fuel trips 799 Record of
servicing to provide 910 Dogs on doors from accomodation to
deck
to free 910 E/Room door self closure to repair 915 Mark '
crew
escape keep clear' on upper
915 Mark
chest in ER 930 Light ship check to conduct to verify vessels
936
to demonstrate 945 24v emer:gency lighting to test 945 Emergency light in
cabin
escape trunking to restore 950 Electrical co.ndition report to provide 950 Cooker shut offs to mark 999
to conduct In accordance with current practice & legislation 999 One bolt
E/Room ladder missing - replace Relates to survey? s s s s s s s s s s s s s s s s s s s s s s s s NONE NONE
999 Risk assessmentto sight ·. s 99 999 Form SF44 - condition of to s 99 complete and retum ASAP ~260 Dog deadlight.s to be fr.¢~d a$ necessary s 99 1499 maintenance report to s 99 provide 1541 to be swung and card s 99 displayed 1570 Nautical Almanac to sight s 99 1699 Radio survey to conduct s 99 1940 Sign re. oil pollution to be displayed in ER s 99 2099 SO LAS I Notice to display s 99
Annex G Record of of a (Chloe T )
Annex H Equation for calculating rate of rate calculations 1 Area of (m²) = Flooding rate (Kg/s) C x 2P Where: C D D = Coefficient of drag (taken as 0.62 for a hole in a flat plate) = density, 1025 kg/m³ for seawater P = pressure at given depth = gh where = density g = gravity (9.81 m/s²) h = depth below the (m) 2 Flooding rate (Kg/s) = Flooding rate (m³/hr) x 3600 3 Diameter of hole (mm) = 2 Area (m²) π x 1000
~lAS UK & DT 점검/검사 세부 정보 선박 세부 정보 선박 ID 41 883 Next ID 63534 그룹 ID 30088 선박 이름 CHLOE T IMO 번호 0000000 어선 번호 PZ1186 선종 F1 - 어선 - 강철 선적국 670- 영국 선급 0 - 없음 공식 번호 810739 호출부호 MLVY3 OWner 건조 연도 1968 Kw 313 길이(m) 23.55 점검 세부 정보 해사사무소 플리머스(Plymouth) 점검일 19/03/2002 억류 여부 N 국가 영국 장소 뉴린(Newlyn) 점검 검사와 병행 유형 MACRIS 코드 비고 선박 조치 UK 분류 코드 X 재화중량 총톤수 000136 입력일 28/03/2002 해제일 해상 점검 여부 N 점검에 따른 선박 조치 없음 검사 세부 정보 검사 유형 FVA(F!) 갑 구분(Category A) 검사 - 어선(PART) fLO 검사 세부 정보 점검에 fLO 검사 없음
증서 세부 정보 FVC UN I TED 09/04/1998 24/0212002 KINGDOM UKE 영국 01/06/2000 24/02/2002 결함 세부 정보 • 검사관 설명 299 선원 자격 기록을 제출할 것(양식 제공됨) 350 선실 등 1개를 가릴 것 371 응급처치 키트를 재증명할 것 520 그물 창고의 등 1개를 수리할 것 599 윈치 하우스 역지 밸브를 분해 점검할 것 650 구명부환 2개를 재정비할 것 660 구명조끼 등화 배터리를 교체할 것 699 오래된 줄 발사 로켓을 폐기할 것 699 구명조끼를 더 접근하기 쉬운 공간에 보관하는 방안을 검토할 것 745 연돌 갑판의 모든 통풍구를 분해 점검할 것 745 모든 연료 트립(fuel trip)을 시험할 것 799 소화기 정비 기록을 제출할 것 910 거주구역에서 쉘터 갑판으로 통하는 문의 도그를 자유롭게 할 것 910 기관실 문 자동 폐쇄 장치를 수리할 것 915 상부 해치에 '선원 탈출구 - 접근 금지'를 표시할 것 915 기관실의 밸브 박스를 표시할 것 930 선박 복원성을 확인하기 위해 경하 상태 점검을 실시할 것 936 비상 조타를 시연할 것 945 24v 비상 조명을 시험할 것 945 선실 탈출 트렁크의 비상등을 복구할 것 950 전기 상태 보고서를 제출할 것 950 조리기 차단 장치를 표시할 것 999 현행 관행 및 법령에 따라 선체 검사를 실시할 것 999 기관실 사다리를 고정하는 볼트 1개가 없음 - 교체할 것 검사와 관련됨? s s s s s s s s s s s s s s s s s s s s s s s s 없음 없음
999 위험성 평가를 확인할 것 · . s 99 999 양식 SF44 - 선수 장치 상태를 작성하여 가능한 한 빨리 반송할 것 s 99 ~260 데드라이트 도그를 필요에 따라 자유롭게 할 것 s 99 1499 주기관 정비 보고서를 제출할 것 s 99 1541 나침반을 스윙하고 자차표를 게시할 것 s 99 1570 항해 연감을 확인할 것 s 99 1699 무선 검사를 실시할 것 s 99 1940 기관실에 유류 오염 관련 표지를 게시할 것 s 99 2099 SOLAS I 고시를 게시할 것 s 99 부록 G 어선 명세 기록 (Chloe T호)
부록 H 침수 속도 계산식
침수 속도 계산 1 구멍의 면적 (m²) = 침수 속도 (Kg/s) C x 2P 여기서: C D D = 항력 계수(평판의 구멍에 대해 0.62로 취함) = 밀도, 해수의 경우 1025 kg/m³ P = 주어진 깊이에서의 압력 = gh 여기서 = 밀도 g = 중력 가속도 (9.81 m/s²) h = 수선 아래 깊이 (m) 2 침수 속도 (Kg/s) = 침수 속도 (m³/hr) x 3600 3 구멍의 지름 (mm) = 2 면적 (m²) π x 1000
- to be yvitnessed by
252
Crew
qualifications to be verified 699 Provide servicing dates and certificates for
371 Provide copy of first aid kit certificate 199 Provide copy of
999
to be sighted 1270 Door and
hatch
seals to be renewed as required 1275 Roatary vent on
deck
to renew 1240 Corroded escape
to repair 945 Emergency light in escape trunking to repair 915 Mark escape
hatch
915 No smoking sign requirednear batteries in ·1 • ' Last Last :·-. Last Surv Survey . Survey Date Country ... Place 00 000 s s s s s s s s s s s s s s s s s s s s s s s s s s Last Survey Issue Authority NONE